Displaying all 5 publications

Abstract:
Sort:
  1. Chua PY, Day AC, Lai KL, Hall N, Tan LL, Khan K, et al.
    Br J Ophthalmol, 2018 Apr;102(4):539-543.
    PMID: 28794074 DOI: 10.1136/bjophthalmol-2017-310725
    PURPOSE: To estimate the incidence, and describe the clinical features and short-term clinical outcomes of acute angle closure (AAC).

    METHODS: Patients with newly diagnosed AAC were identified prospectively over a 12-month period (November 2011 to October 2012) by active surveillance through the Scottish Ophthalmic Surveillance Unit reporting system. Data were collected at case identification and at 6 months follow-up.

    RESULTS: There were 114 cases (108 patients) reported, giving an annual incidence of 2.2 cases (95% CI 1.8 to 2.6) or 2 patients (95% CI 1.7 to 2.4) per 1 00 000 in the whole population in Scotland. Precipitating factors were identified in 40% of cases. Almost one in five cases was associated with topical dilating drops. Best-corrected visual acuity (BCVA) at presentation ranged from 6/6 to perception of light. The mean presenting intraocular pressure (IOP) was 52 mm Hg (SD 11). Almost 30% cases had a delayed presentation of 3 or more days. At 6 months follow-up, 75% had BCVA of 6/12 or better and 30% were found to have glaucoma at follow-up. Delayed presentation (≥3 days) was associated with higher rate of glaucoma at follow-up (22.6% vs 60.8%, p<0.001), worse VA (0.34 vs 0.74 LogMAR, p<0.0001) and need for more topical medication (0.52 vs 1.2, p=0.003) to control IOP.

    CONCLUSION: The incidence of AAC in Scotland is relatively low compared with the Far East countries, but in line with previous European data. Almost one in five cases were associated with pupil dilation for retinal examination.

  2. Burr JM, Cooper D, Ramsay CR, Che Hamzah J, Azuara-Blanco A
    Br J Ophthalmol, 2021 May 18.
    PMID: 34006510 DOI: 10.1136/bjophthalmol-2021-318901
    AIM: To estimate the minimally important difference (MID) in change in National Eye Institute Visual Function Questionnaire-25 (VFQ-25) composite score using methods aligned with patient perception.

    METHODS: Retrospective analysis of prospectively collected data from adults with primary angle closure or primary angle closure glaucoma enrolled in the Effectiveness, in Angle-closure Glaucoma, of Lens Extraction study. We included data from 335 participants with patient reported visual function (VFQ-25) and health status measured by the EQ-5D-3L over 36 months. We used the recommended anchor-based methods (receiver operating characteristic (ROC), predictive modelling and mean change) to determine the MID of the VFQ-25. EQ-5D-3L anchor change was defined as none (<0.065); minimal (0.065≤EQ-5D-3L change ≤0.075 points) and greater change (>0.075 points).

    RESULTS: Mean baseline VFQ-25 score was 87.6 (SD 11.8). Estimated MIDs in the change in VFQ-25 scores (95% CI) were 10.5 (1.9 to 19.2); 3.9 (-2.3 to 10.1); 5.8 (1.9 to 7.2) and 8.1 (1.7 to 14.8) for the 'within-patient', 'between-patient' change, ROC and predictive modelling anchor methods respectively. Excluding estimates from the methodologically weaker 'within-patient' method, the MID of a change in VFQ-25 composite score is 5.8 (median value).

    CONCLUSIONS: Estimates of the MID using multiple methods assist in the interpretation of the VFQ scores. In the context of early glaucoma related visual disability, a change score of around six points on the VFQ-25 is likely to be important to patients. Further confirmatory research is required. Studies comparing changes in patient-reported outcome measure scores with a global measure of patients' perceived change are required.

  3. Che Hamzah J, Daka Q, Azuara-Blanco A
    Eye (Lond), 2020 01;34(1):155-160.
    PMID: 31772381 DOI: 10.1038/s41433-019-0669-7
    Glaucoma services are overwhelmed and struggling to accommodate current demand. Reducing the need for hospital based services would improve our ability to see those most at risk of vision loss, which could both reduce demand and improve patient outcomes. Digital technologies that provide opportunities for home monitoring of glaucoma progression have potential to contribute to solve these challenges and, potentially, improve glaucoma care. This article will review the literatures of well-established technologies that support home monitoring for glaucoma, specifically home tonometry (with rebound tonometry) and perimetry with Moorfields Motion Displacement Test and Melbourne Rapid Field.
  4. Gopalakrishna G, Langendam M, Scholten R, Bossuyt P, Leeflang M, Noel-Storr A, et al.
    Diagn Progn Res, 2017;1:11.
    PMID: 31095132 DOI: 10.1186/s41512-017-0011-4
    [This corrects the article DOI: 10.1186/s41512-016-0001-y.].
  5. Day AC, Cooper D, Burr J, Foster PJ, Friedman DS, Gazzard G, et al.
    Br J Ophthalmol, 2018 12;102(12):1658-1662.
    PMID: 29453222 DOI: 10.1136/bjophthalmol-2017-311447
    BACKGROUND: To describe the surgical technique and refractive outcomes following clear lens extraction (CLE) in the Effectiveness, in Angle-closure Glaucoma, of Lens Extraction trial.

    METHODS: Review of prospectively collected data from a multicentre, randomised controlled trial comparing CLE and laser peripheral iridotomy. Eligible participants were ≥50 years old and newly diagnosed with (1) primary angle closure (PAC) with intraocular pressure above 30 mm Hg or (2) PAC glaucoma. We report the postoperative corrected distance visual acuity (CDVA) and refractive outcomes at 12 and 36 months postoperatively for those who underwent CLE.

    RESULTS: Of the 419 participants, 208 were randomised to CLE. Mean baseline CDVA was 77.9 (SD 12.4) letters and did not change significantly at 36 months when mean CDVA was 79.9 (SD 10.9) letters. Mean preoperative spherical equivalents were +1.7 (SD 2.3) and +0.08 (SD 0.95) diopters (D) at 36 months. Fifty-nine per cent and 85% eyes were within ±0.5D and ±1.0D of predicted refraction, respectively, at 36 months.

    CONCLUSIONS: Mean CDVA in patients undergoing CLE for angle-closure glaucoma appeared stable over the 3-year study period. Refractive error was significantly reduced with surgery but refractive predictability was suboptimal.

    TRIAL REGISTRATION NUMBER:

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links