INTRODUCTION: Adhering to test administration and standardized instructions is important for attainment of accurate and reliable results in performance-based tests.
PURPOSE OF THE STUDY: To determine test-retest and interrater reliability of standardized translated instruction (St-TI) and spontaneously translated instruction (Sp-TI) of a hand function test.
METHODS: Four raters and seventy-two subjects were divided into 2 groups: St-TI group, direct administration of the Hong Kong Chinese version of the Jebsen Hand Function Test to subjects by raters; and Sp-TI group, spontaneously translating the Jebsen-Taylor Hand Function Test from English into Chinese by raters. Test-retest and interrater reliability were calculated based on instruction time by the rater and performance time by the subject.
RESULTS: Test-retest and interrater reliability of instruction time by rater for St-TI has intraclass correlation coefficient of 0.35 to 0.70 and 0.24 to 0.55, respectively, whereas that for Sp-TI was -0.50 to 0.18 and -0.09 to 0.51, respectively. Test-retest and interrater reliability of performance time by subject for St-TI was 0.56 to 0.84 and 0.33 to 0.78, respectively, whereas that for Sp-TI was 0.54 to 0.87 and 0.35 to 0.77, respectively. Sp-TI had two test-retest minimal detectable change percent values that fell within the acceptable range (subtest 3 = 21.9% and subtest 6 = 25.7%).
CONCLUSION: Instruction time by rater for Jebsen-Taylor Hand Function Test subtests had generally poor to moderate test-retest and interrater reliability for both St-TI and Sp-TI. Performance time by subject generally had moderate to good reliability, except for St-TI with poor to good interrater reliability.
PURPOSE: To identify types of orthoses (including relative motion), effectiveness, and outcome measurements used to non-surgically manage adult and pediatric trigger finger.
STUDY DESIGN: Systematic review.
METHODS: The study was undertaken according to The Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 Statement and registered with the International Prospective Register of Systematic Reviews Registry, number CRD42022322515. Two independent authors electronically and manually searched, and screened 4 databases; selected articles following pre-set eligibility criteria; assessed the quality of the evidence using the Structured Effectiveness for Quality Evaluation of Study; and extracted the data.
RESULTS: Of the 11 articles included, 2 involved pediatric trigger finger and 9 adult trigger finger. Orthoses for pediatric trigger finger positioned finger(s), hand, and/or wrist of children in neutral extension. In adults, a single joint was immobilized by the orthosis, blocking either the metacarpophalangeal joint or the proximal or distal interphalangeal joint. All studies reported positive results with statistically significant improvements and medium to large effect size to almost every outcome measure, including the Number of Triggering Events in Ten Active Fist 1.37, Frequency of Triggering from 2.07 to 2.54, Quick Disabilities of the Arm, Shoulder and Hand Outcome Measure from 0.46 to 1.88, Visual Analogue Pain Scale from 0.92 to 2.00, and Numeric Rating Pain Scale from 0.49 to 1.31. Severity tools and patient-rated outcome measures were used with the validity and reliability of some unknown.
CONCLUSIONS: Orthoses are effective for non-surgical management of pediatric and adult trigger finger using various orthotic options. Although used in practice, evidence for the use of relative motion orthosis is absent. High-quality studies based on sound research questions and design using reliable and valid outcome measures are needed.
Methods: This cross-sectional study recruited occupational therapy bachelor's degree graduates using an online survey. The Work Extrinsic and Intrinsic Motivation Scale (WEIMS) was used to measure level of work motivation.
Results: Responses from 82 (60.3%) graduates (male: 26.8%; female: 73.2%) were analysed. Sixty-two (75.6%) graduates worked locally and 20 (24.4%) worked in foreign countries. The average Work Self-Determination Index (W-SDI) score for WEIMS is +11.38 with 78 (95.1%) of graduates demonstrated a self-determined motivational profile and 4 (4.9%) demonstrated a nonself-determined profile. Graduates in the private sector (13.10 ± 6.47) show significantly higher W-SDI score compared to those in the public sector (9.40 ± 6.06), p = 0.01. W-SDI scores appeared higher among clinician (11.67 ± 6.40), case manager (13.33), and others (14.90 ± 8.23); and those with work experience of 5-6 years (13.11 ± 6.90) and less than one year (12.65 ± 7.12). Male (10.29 ± 6.86) and female (11.79 ± 6.39) graduates shared equally high score. There is no significant difference in W-SDI score based on job position, length of work experience, and gender.
Conclusion: Occupational therapy graduates have high work motivation as evident by their self-determined profile. Only work sector imposes difference in work motivation among these graduates. Copyright © 2017, Hong Kong Occupational Therapy Association. Published by Elsevier (Singapore) Pte Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
METHODS: This study involved: (1) four English teachers (translators) for forward and backward translation procedures; (2) 10 experts in the field of occupational therapy (expert reviewers) for content validity testing; and (3) 60 undergraduate students (participants) for test-retest reliability testing.
RESULTS: PPT-M had excellent content validity with Item-Content Validity Index = 0.9-1.0, Scale-Content Validity Index/Average = 0.93-0.95, and a slightly lower Scale-Content Validity Index/Universal Agreement = 0.25-0.75. Test-retest reliability for 3-trial administration (n = 30; Intraclass Correlation Coefficients, ICCs = 0.76-0.85; good) was higher compared to 1-trial administration (n = 30; ICCs = 0.34-0.46; poor) for all subtests. Both trial administrations were mostly affected by systematic errors, especially practice effect as the retests gave higher scores. Random errors mostly affected Subtest 3 of 1-trial administration, evident by its Minimal Detectable Change Percent values = 30.84% that fell beyond the acceptable range.
CONCLUSION: PPT-M has the potential to be a valuable instrument for measuring hand dexterity among Malay speaking individuals especially when the 3-trial administration is used.
METHODS: An online English-language survey was distributed to 90 occupational therapists and physiotherapists including MSHT members and non-members. Participation required management of at least one extensor tendon repair in the preceding year. Five approaches were surveyed: immobilisation, early passive motion (EPM) with dynamic splinting, and early active motion (EAM) delivered by resting hand (RH), palmar resting interphalangeal joints free (PR), and relative motion extension (RME) splints.
RESULTS: Thirty-seven of the 53 therapists (68%) who commenced the survey completed it. The most used approach was dynamic/EPM (28%), followed by RH/immobilisation (22%) and RH/EAM (22%). A preference for RME/EAM was identified with implementation barriers being surgeon preference and hand therapist confidence.
DISCUSSION: Approach selection for Malaysian therapists differed from the combined IFSHT and Asia-Pacific respondents, with the former using dynamic/EPM and RH/immobilisation compared to IFSHT respondents who predominately used RME/EAM and PR/EAM. This survey provides valuable insights into Malaysian hand therapists' practices. If implementation barriers and therapist confidence are addressed, Malaysian practice patterns may change to better align with current evidence.
DESIGN: A randomized controlled trial.
SETTING: Occupational therapy unit of a public hospital.
SUBJECTS: A total of 46 adults with stroke.
INTERVENTION: After random assignment, for six weeks, both intervention group and control group received a 2 hour/week conventional occupational therapy program, with the intervention group receiving an extra 6 hour/day pressure garment application (long glove).
MAIN MEASURES: Modified Modified Ashworth Scale, Disabilities of Arm, Shoulder and Hand Outcome Measure, and Jebsen-Taylor Hand Function Test. Eligibility measures: Mini Mental State Examination and Modified Modified Ashworth Scale. Assessments were performed at baseline and six weeks postintervention.
RESULTS: There were 21 participants with the mean age of 51.19 (8.28) years in the intervention group and 22 participants with the mean (SD) age of 52.82 (8.71) years in the control group. The intervention group had median (interquartile range (IQR)) post-stroke duration of 1 (1) month, while for the control group, they were 2 (2) months. There was no difference in spasticity, and both perceived and actual arm functions between the groups at six weeks after baseline.
CONCLUSION: Wearing a pressure garment on the arm for 6 hours daily had no effect in controlling spasticity or on improving arm function in the early stages after stroke.
METHODS: Published literature was systematically searched according to PRISMA guidelines using specific key terms. Initial search identified 785 studies; however only seven met the inclusion criteria and were assessed for final review. Studies were methodologically appraised using the McMaster Critical Review Form-Quantitative Studies.
RESULTS: The review found no randomised control trial study design pertaining to the reviewed area. However, it can be seen that occupational therapy interventions for writing skills in 4-6 year old children managed to increase the targeted skills. The results were similar across samples with or without disabilities. An effective integration of occupational therapy interventions into educational curriculum was found to save both time and cost.
CONCLUSION: The long-term benefit from these interventions and the effects of these interventions on a broader spectrum of fine motor abilities need to be explored further with stronger research designs. However, the lack of studies adopting high level study designs, i.e., RCT designs means, results need to be approached with caution by occupational therapists when implementing handwriting skills intervention in practice.
METHODS: This study was divided into three phases: (1) translation and linguistic validity involving both forward and backward translations; (2) establishment of face validity and content validity; and (3) establishment of reliability involving inter-rater, test-retest and internal consistency analyses. Data used for these analyses were obtained by interviewing 65 elderly respondents.
RESULTS: Percentages of Content Validity Index for 4 criteria were from 88.89 to 100.0. The Cronbach α coefficient for internal consistency was 0.838. Intra-class Correlation Coefficient of inter-rater reliability and test-retest reliability was 0.957 and 0.950 respectively.
CONCLUSIONS: The result shows that the Lawton Instrumental Activities of Daily Living Scale - Malay Version has excellent reliability and validity for use with the Malay speaking elderly people in Malaysia. This scale could be used by professionals to assess functional ability of elderly who live independently in community.