METHODS: A questionnaire survey was conducted at an autism center among autistic children and their parents. This study included autistic children aged between 6 and 16 (45 males, 42 females, mean age 8.7 years, standard deviation 2.3). Eighty-seven participants were involved in the survey to determine the sensory perceptions, intolerance, preferences, and sensitivities of children with an autism spectrum disorder toward colors and lighting. The margin of error at the statistical analysis's 95% confidence level is ± 0.481.
RESULTS: As per this case report, the children have various color preferences and respond differently to different shades. Different hues have varying effects on autistic children, with many neutral tones and mellow shades proven to be autistic-friendly with their calming and soothing effect, while bright, bold, and intense colors are refreshing and stimulating. The stimulus of bright-lighting causes behavioral changes in autistic children prone to light sensitivity.
CONCLUSION: The insights gained from this interaction with parents and caretakers of autistic children could be helpful for designers to incorporate specific autistic-friendly design elements that make productive interior spaces. A complete understanding of the effect of factors like color and lighting on the learning ability and engagement of autistic children in an indoor environment is essential for designers and clinicians. The main findings of this study could be helpful for a designer and clinicians to address designing an autism-friendly built environment with a color palette and lighting scheme conducive to their wellbeing and to maximize their cognitive functioning.
METHODS: This study proposed an end-to-end air quality predictive model for smart city applications, utilizing four machine learning techniques and two deep learning techniques. These include Ada Boost, SVR, RF, KNN, MLP regressor and LSTM. The study was conducted in four different urban cities in Selangor, Malaysia, including Petaling Jaya, Banting, Klang, and Shah Alam. The model considered the air quality data of various pollution markers such as PM2.5, PM10, O3, and CO. Additionally, meteorological data including wind speed and wind direction were also considered, and their interactions with the pollutant markers were quantified. The study aimed to determine the correlation variance of the dependent variable in predicting air pollution and proposed a feature optimization process to reduce dimensionality and remove irrelevant features to enhance the prediction of PM2.5, improving the existing LSTM model. The study estimates the concentration of pollutants in the air based on training and highlights the contribution of feature optimization in air quality predictions through feature dimension reductions.
RESULTS: In this section, the results of predicting the concentration of pollutants (PM2.5, PM10, O3, and CO) in the air are presented in R2 and RMSE. In predicting the PM10 and PM2.5concentration, LSTM performed the best overall high R2values in the four study areas with the R2 values of 0.998, 0.995, 0.918, and 0.993 in Banting, Petaling, Klang and Shah Alam stations, respectively. The study indicated that among the studied pollution markers, PM2.5,PM10, NO2, wind speed and humidity are the most important elements to monitor. By reducing the number of features used in the model the proposed feature optimization process can make the model more interpretable and provide insights into the most critical factor affecting air quality. Findings from this study can aid policymakers in understanding the underlying causes of air pollution and develop more effective smart strategies for reducing pollution levels.
METHODS: We proposed a new feature extraction method by replacing fully-connected layer with global average pooling (GAP) layer. A comparative analysis was conducted to compare the efficacy of 16 different convolutional neural network (CNN) feature extractors and three machine learning classifiers.
RESULTS: Experimental results revealed the potential of CNN feature extractors in conducting multitask diagnosis. Optimal model consisted of VGG16-GAP feature extractor and KNN classifier. This model not only outperformed the other tested models, it also outperformed the state-of-art methods with higher balanced accuracy, higher Cohen's kappa, higher F1, and lower mean squared error (MSE) in seven OA features prediction.
CONCLUSIONS: The proposed model demonstrates pain prediction on plain radiographs, as well as eight OA-related bony features. Future work should focus on exploring additional potential radiological manifestations of OA and their relation to therapeutic interventions.
METHODS: Five APT quantification methods, including asymmetry analysis and its variants as well as two Lorentzian model-based methods, were applied to data acquired from six rats that underwent middle cerebral artery occlusion scanned at 9.4T. Diffusion and perfusion-weighted images, and water relaxation time maps were also acquired to study the relationship of these conventional imaging modalities with the different APT quantification methods.
RESULTS: The APT ischemic area estimates had varying sizes (Jaccard index: 0.544 ≤ J ≤ 0.971) and had varying correlations in their distributions (Pearson correlation coefficient: 0.104 ≤ r ≤ 0.995), revealing discrepancies in the quantified ischemic areas. The Lorentzian methods produced the highest contrast-to-noise ratios (CNRs; 1.427 ≤ CNR ≤ 2.002), but generated APT ischemic areas that were comparable in size to the cerebral blood flow (CBF) deficit areas; asymmetry analysis and its variants produced APT ischemic areas that were smaller than the CBF deficit areas but larger than the apparent diffusion coefficient deficit areas, though having lower CNRs (0.561 ≤ CNR ≤ 1.083).
CONCLUSION: There is a need to further investigate the accuracy and correlation of each quantification method with the pathophysiology using a larger scale multi-imaging modality and multi-time-point clinical study. Future studies should include the magnetization transfer ratio asymmetry results alongside the findings of the study to facilitate the comparison of results between different centers and also the published literature.
METHODS: In this work, we developed deep convolutional neural network (CNN) based heterogeneous ensemble models for automated analysis of renal histopathological images without detailed annotations. The proposed method would first segment the histopathological tissue into patches with different magnification factors, then classify the generated patches into normal and tumor tissues using the pre-trained CNNs and lastly perform the deep ensemble learning to determine the final classification. The heterogeneous ensemble models consisted of CNN models from five deep learning architectures, namely VGG, ResNet, DenseNet, MobileNet, and EfficientNet. These CNN models were fine-tuned and used as base learners, they exhibited different performances and had great diversity in histopathological image analysis. The CNN models with superior classification accuracy (Acc) were then selected to undergo ensemble learning for the final classification. The performance of the investigated ensemble approaches was evaluated against the state-of-the-art literature.
RESULTS: The performance evaluation demonstrated the superiority of the proposed best performing ensembled model: five-CNN based weighted averaging model, with an Acc (99%), specificity (Sp) (98%), F1-score (F1) (99%) and area under the receiver operating characteristic (ROC) curve (98%) but slightly inferior recall (Re) (99%) compared to the literature.
CONCLUSIONS: The outstanding robustness of the developed ensemble model with a superiorly high-performance scores in the evaluated metrics suggested its reliability as a diagnosis system for assisting the pathologists in analyzing the renal histopathological tissues. It is expected that the proposed ensemble deep CNN models can greatly improve the early detection of renal cancer by making the diagnosis process more efficient, and less misdetection and misdiagnosis; subsequently, leading to higher patients' survival rate.
METHODS: Diffusion-weighted imaging, perfusion-weighted imaging, and chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) data were acquired from five rats that underwent scans at 9.4 T after middle cerebral artery occlusion.
RESULTS: The apparent diffusion coefficient (ADC), cerebral blood flow (CBF), and apparent exchange-dependent relaxations (AREX) at 3.5 ppm and NOE(-1.6 ppm) were quantified. AREX(3.5 ppm) and NOE(-1.6 ppm) were found to be hypointense and exhibited different signal patterns within the ischemic tissue. The NOE(-1.6 ppm) deficit areas were equal to or larger than the ADC deficit areas, but smaller than the AREX(3.5 ppm) deficit areas. This suggested that NOE(-1.6 ppm) might further delineate the acidotic tissue estimated using AREX(3.5 ppm). Since NOE(-1.6 ppm) is closely related to membrane phospholipids, NOE(-1.6 ppm) potentially highlighted at-risk tissue affected by lipid peroxidation and membrane damage. Altogether, the ADC/NOE(-1.6 ppm)/AREX(3.5 ppm)/CBF mismatches revealed four zones of increasing sizes within the ischemic tissue, potentially reflecting different pathophysiological information.
CONCLUSIONS: Using CEST coupled with ADC and CBF, the ischemic tissue may thus potentially be separated into four zones to better understand the pathophysiology after stroke and improve ischemic tissue fate definition. Further verification of the potential utility of NOE(-1.6 ppm) may therefore lead to a more precise diagnosis.
AIMS: A variation of anisotropic diffusion is proposed that can reduce speckle noise without compromising the image quality of the edges and other important details.
METHODS: For this technique, four gradient thresholds were adopted instead of one. A new diffusivity function that preserves the edge of the resultant image is also proposed. To automatically terminate the iterative procedures, the Mean Absolute Error as its stopping criterion was implemented.
RESULTS: Numerical results obtained by simulations unanimously indicate that the proposed method outperforms conventional speckle reduction techniques. Nevertheless, this preliminary study has been conducted based on a small number of asymptomatic subjects.
CONCLUSION: Future work must investigate the feasibility of this method in a large cohort and its clinical validity through testing subjects with a symptomatic cartilage injury.