Displaying publications 1 - 20 of 33 in total

Abstract:
Sort:
  1. Lau YL, Ismail IB, Izati Binti Mustapa N, Lai MY, Tuan Soh TS, Hassan AH, et al.
    Am J Trop Med Hyg, 2020 Dec;103(6):2350-2352.
    PMID: 33098286 DOI: 10.4269/ajtmh.20-1079
    A simple and rapid reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the detection of SARS-CoV-2. The RT-LAMP assay was highly specific for SARS-CoV-2 and was able to detect one copy of transcribed SARS-CoV-2 RNA within 24 minutes. Assay validation performed using 50 positive and 32 negative clinical samples showed 100% sensitivity and specificity. The RT-LAMP would be valuable for clinical diagnosis and epidemiological surveillance of SARS-CoV-2 infection in resource-limited areas as it does not require the use of sophisticated and costly equipment.
  2. Lai MY, Ponnampalavanar SSS, Omar SFS, Lau YL
    Acta Trop, 2024 Mar;251:107120.
    PMID: 38199452 DOI: 10.1016/j.actatropica.2024.107120
    Combining the advantages of PCR and LAMP, we described a new technique, namely PCR-LAMP, for malaria diagnosis. The whole process of DNA amplification can be completed in 35 min. This hybrid amplification technique markedly improved the sensitivity of detection compared to the classic single PCR or LAMP assay alone. PCR-LAMP assay had a detection limit of 1 copy/µL for P. knowlesi and P. ovale, 0.1 copy/µL for P. vivax, P. falciparum and P. malariae, respectively. To facilitate the endpoint detection, xylenol orange was added. Positive samples were indicated in orange while negative reactions were violet. The inclusion of xylenol orange into the LAMP reaction mix significantly reduces the post-amplification workload. Without relying on the use of specific instruments, the color changes of the amplicons could be visualized directly through the naked eye. In conclusion, PCR-LAMP poses the potential to be developed as a new malaria molecular diagnosis tool.
  3. Mat Salleh NH, Rahman MFA, Samsusah S, De Silva JR, Ng DC, Ghozali AH, et al.
    Trans R Soc Trop Med Hyg, 2020 Sep 01;114(9):700-703.
    PMID: 32511702 DOI: 10.1093/trstmh/traa042
    Five children in Pos Lenjang, Pahang, Malaysia were PCR-positive for vivax malaria and were admitted to the hospital from 5 to 26 July 2019. One of the patients experienced three episodes of recurrence of vivax malaria. Microsatellite analysis showed that reinfection is unlikely. Drug resistance analysis indicated that Riamet (artemether-lumefantrine) is effective. Cytochrome P450 2D6 (CYP2D6) testing showed that this patient has defective CYP2D6 function. Primaquine failure to clear the Plasmodium vivax hypnozoites may be the cause of recurring infections in this patient. This report highlights the need for the development of liver-stage curative antimalarials that do not require metabolism by the CYP2D6 enzyme.
  4. Lau YL, Lai MY, Teoh BT, Abd-Jamil J, Johari J, Sam SS, et al.
    PLoS One, 2015;10(9):e0138694.
    PMID: 26384248 DOI: 10.1371/journal.pone.0138694
    Dengue is usually diagnosed by isolation of the virus, serology or molecular diagnostic methods. Several commercial kits for the diagnosis of dengue are existing, but concerns have arisen regarding to the affordability and performance characteristics of these kits. Hence, the loop-mediated isothermal amplification (LAMP) is potentially ideal to be used especially in resource limited environments. Serum was collected from healthy donors and patients diagnosed with dengue infection. RNA extracted from the serum samples were tested by reverse-transcription-LAMP assay developed based on 3'-NCR gene sequences for DENV 1-4. Results were interpreted by a turbidity meter in real time or visually at the end of the assay. Sensitivity and specificity of RT-LAMP results were calculated and compared to qRT-PCR and ELISA. RT-LAMP is highly sensitive with the detection limit of 10 RNA copies for all serotypes. Dengue virus RNA was detected in all positive samples using RT-LAMP and none of the negative samples within 30-45 minutes. With continuing efforts in the optimization of this assay, RT-LAMP may provide a simple and reliable test for detecting DENV in areas where dengue is prevalent.
  5. Lai MY, Tang SN, Lau YL
    Am J Trop Med Hyg, 2021 Jun 15;105(2):375-377.
    PMID: 34129521 DOI: 10.4269/ajtmh.21-0150
    Coronavirus disease 2019 (COVID-19), which is caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has been spreading rapidly all over the world. In the absence of effective treatments or a vaccine, there is an urgent need to develop a more rapid and simple detection technology of COVID-19. We describe a WarmStart colorimetric reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay for the detection of SARS-CoV-2. The detection limit for this assay was 1 copy/µL SARS-CoV-2. To test the clinical sensitivity and specificity of the assay, 37 positive and 20 negative samples were used. The WarmStart colorimetric RT-LAMP had 100% sensitivity and specificity. End products were detected by direct observation, thereby eliminating the need for post-amplification processing steps. WarmStart colorimetric RT-LAMP provides an opportunity to facilitate virus detection in resource-limited settings without a sophisticated diagnostic infrastructure.
  6. Lai MY, Bukhari FDM, Zulkefli NZ, Ismail I, Mustapa NI, Soh TST, et al.
    Int J Infect Dis, 2022 Jul;120:132-134.
    PMID: 35472524 DOI: 10.1016/j.ijid.2022.04.036
    OBJECTIVES: Preventing reverse transcription loop-mediated isothermal amplification (RT-LAMP) carryover contamination could be solved by adding deoxyuridine triphosphate (dUTP) and uracil-DNA glycosylase (UDG) into the reaction master mix.

    METHODS: RNA was extracted from nasopharyngeal swab samples by a simple RNA extraction method.

    RESULTS: Testing of 77 samples demonstrated 91.2% sensitivity (95% confidence interval [CI]: 78-98.2%) and 100% specificity (95% confidence interval: 92-100%) using UDG RT-LAMP.

    CONCLUSION: This colorimetric UDG RT-LAMP is a simple-to-use, fast, and easy-to-interpret method, which could serve as an alternative for diagnosis of SARS-CoV-2 infection, especially in remote hospitals and laboratories with under-equipped medical facilities.

  7. Lau YL, Lai MY, Anthony CN, Chang PY, Palaeya V, Fong MY, et al.
    Am J Trop Med Hyg, 2015 Jan;92(1):28-33.
    PMID: 25385862 DOI: 10.4269/ajtmh.14-0309
    In this study, three molecular assays (real-time multiplex polymerase chain reaction [PCR], merozoite surface antigen gene [MSP]-multiplex PCR, and the PlasmoNex Multiplex PCR Kit) have been developed for diagnosis of Plasmodium species. In total, 52 microscopy-positive and 20 malaria-negative samples were used in this study. We found that real-time multiplex PCR was the most sensitive for detecting P. falciparum and P. knowlesi. The MSP-multiplex PCR assay and the PlasmoNex Multiplex PCR Kit were equally sensitive for diagnosing P. knowlesi infection, whereas the PlasmoNex Multiplex PCR Kit and real-time multiplex PCR showed similar sensitivity for detecting P. vivax. The three molecular assays displayed 100% specificity for detecting malaria samples. We observed no significant differences between MSP-multiplex PCR and the PlasmoNex multiplex PCR kit (McNemar's test: P = 0.1489). However, significant differences were observed comparing real-time multiplex PCR with the PlasmoNex Multiplex PCR Kit (McNemar's test: P = 0.0044) or real-time multiplex PCR with MSP-multiplex PCR (McNemar's test: P = 0.0012).
  8. Lee WC, Cheong FW, Amir A, Lai MY, Tan JH, Phang WK, et al.
    Malar J, 2023 Oct 19;22(1):316.
    PMID: 37858164 DOI: 10.1186/s12936-023-04732-x
  9. Lai MY, Lau YL
    Acta Trop, 2020 May 15;208:105511.
    PMID: 32422380 DOI: 10.1016/j.actatropica.2020.105511
    In this study, recombinase polymerase amplification (RPA) combined with SYBR Green I was developed for the detection of Plasmodium knowlesi. Positive samples were indicated with a green color while negative samples were orange. To increase the efficiency of amplification, an interval mixing step of samples after 3 to 6 min incubation was recommended. Different sets of reaction volumes from 6.25 to 50 µL were tested and the results indicated no differences in detection. RPA's combination with SYBR Green I is fast and easy to perform, hence this method is suitable for use in resource-limited settings.
  10. Mallepaddi PC, Lai MY, Podha S, Ooi CH, Liew JW, Polavarapu R, et al.
    Am J Trop Med Hyg, 2018 09;99(3):704-708.
    PMID: 29943720 DOI: 10.4269/ajtmh.18-0177
    The present study aims to develop a method for rapid diagnosis of malaria using loop-mediated isothermal amplification (LAMP) combined with a lateral flow device (LFD). By adding the biotin-labeled and fluorescein amidite-labeled loop primers to the LAMP reaction solution, the end product can be visualized on a LFD. The entire procedure takes approximately 42 minutes to complete, LAMP assay exhibited high sensitivity, as the detection limit was 0.01 pg/μL for all five Plasmodium species. It was demonstrated that all Plasmodium knowlesi (N = 90) and Plasmodium vivax (N = 56) were positively amplified by LAMP-LFD assay, whereas healthy donor samples (N = 8) were negative. However, not all mixed infections were positive, and other infected nonmalaria samples were negative. Loop-mediated isothermal amplification-LFD represents a robust approach with potential suitability for use in resource-constrained laboratories. We believe that LAMP-LFD has a potential to be developed as point-of-care diagnostic tool in future.
  11. Lau YL, Ismail IB, Mustapa NIB, Lai MY, Tuan Soh TS, Haji Hassan A, et al.
    PLoS One, 2021;16(1):e0245164.
    PMID: 33406112 DOI: 10.1371/journal.pone.0245164
    Rapid diagnosis is an important intervention in managing the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) outbreak. Real time reverse transcription polymerase chain reaction (RT-qPCR) remains the primary means for diagnosing the new virus strain but it is time consuming and costly. Recombinase polymerase amplification (RPA) is an isothermal amplification assay that does not require a PCR machine. It is an affordable, rapid, and simple assay. In this study, we developed and optimized a sensitive reverse transcription (RT)-RPA assay for the rapid detection of SARS-CoV-2 using SYBR Green I and/or lateral flow (LF) strip. The analytical sensitivity and specificity of the RT-RPA assay were tested by using 10-fold serial diluted synthetic RNA and genomic RNA of similar viruses, respectively. Clinical sensitivity and specificity of the RT-RPA assay were carried out using 78 positive and 35 negative nasopharyngeal samples. The detection limit of both RPA and RT-qPCR assays was 7.659 and 5 copies/μL RNA, respectively with no cross reactivity with other viruses. The clinical sensitivity and specificity of RT-RPA were 98% and 100%, respectively. Our study showed that RT-RPA represents a viable alternative to RT-qPCR for the detection of SARS-CoV-2, especially in areas with limited infrastructure.
  12. Zen LPY, Lai MY, Lau YL
    Trop Biomed, 2020 Dec 01;37(4):1124-1128.
    PMID: 33612764 DOI: 10.47665/tb.37.4.1124
    The LAMP assay, amplifies the target DNA rapidly, with 10-fold greater sensitivity than conventional PCR. The greater sensitivity also comes with greater risks of contamination. To overcome this issue, the current project includes either uracil DNA glycosylase (UDG) or a mineral oil overlay in the LAMP assay. Our results indicated that UDG or a mineral oil overlay can effectively prevent carryover contamination in the LAMP assay for the detection of human malaria. By incorporating these preventative methods, contamination can be eliminated and LAMP can potentially be used in the field; and point of care diagnosis for human malaria.
  13. Lai MY, Ooi CH, Jaimin JJ, Lau YL
    Am J Trop Med Hyg, 2020 06;102(6):1370-1372.
    PMID: 32228783 DOI: 10.4269/ajtmh.20-0001
    The incidence of zoonotic malaria, Plasmodium knowlesi, infection is increasing and now is the major cause of malaria in Malaysia. Here, we describe a WarmStart colorimetric loop-mediated isothermal amplification (LAMP) assay for the detection of Plasmodium spp. The detection limit for this assay was 10 copies/µL for P knowlesi and Plasmodium ovale and 1 copy/µL for Plasmodium falciparum, Plasmodium vivax, and Plasmodium malariae. To test clinical sensitivity and specificity, 100 microscopy-positive and 20 malaria-negative samples were used. The WarmStart colorimetric LAMP was 98% sensitive and 100% specific. Amplification products were visible for direct observation, thereby eliminating the need for post-amplification processing steps. Therefore, WarmStart colorimetric LAMP is suitable for use in resource-limited settings.
  14. Wong KC, Lai MY, De Silva JR, Cheong FW, Fong MY, Lau YL
    Trop Biomed, 2021 Jun 01;38(2):143-148.
    PMID: 34172703 DOI: 10.47665/tb.38.2.051
    Normocyte binding protein Xa (NBPXa) has been implied to play a significant role in parasite invasion of human erythrocytes. Previous phylogenetic studies have reported the existence of three types of NBPXa for Plasmodium knowlesi (PkNBPXa). PkNBPXa region II (PkNBPXaII) of type 1, type 2 and type 3 were expressed on mammalian cell surface and interacted with human and macaque (Macaca fascicularis) erythrocytes. The binding activities of PkNBPXaII towards human and macaque erythrocytes were evaluated using erythrocyte-binding assay (EBA). Three parameters were evaluated to achieve the optimal protein expression of PkNBPXaII and erythrocyte binding activity in EBA: types of mammalian cells, post transfection time and erythrocyte incubation time. COS-7, HEK-293, and CHO-K1 cells showed successful expression of PkNBPXaII, despite the protein expression is weak compared to the positive control. COS-7 was used in EBA. All three types of PkNBPXaII showed rosette formation with macaque erythrocytes but not with human erythrocytes. Future studies to enhance the PkNBPXaII expression on surface of mammalian cells is indeed needed in order to elucidate the specific role of PkNBPXaII in erythrocytes invasion.
  15. Lai MY, Rafieqin N, Lee PYL, Amir Rawa MS, Dzul S, Yahaya N, et al.
    Trop Biomed, 2021 Sep 01;38(3):248-253.
    PMID: 34362867 DOI: 10.47665/tb.38.3.065
    Through the regional control programme, Malaysia has been successfully reducing the incidence of Plasmodium falciparum and Plasmodium vivax infections. However, the incidence of zoonotic malaria Plasmodium knowlesi infection is increasing and now has been the major cause of malaria in Malaysia especially Malaysian Borneo. The emergence of knowlesi infection has threatened the malaria elimination programme which the government aims to reduce the overall malaria infections by 2020. Unlike other benign human Plasmodium spp., P. knowlesi can cause fatal infections. The aim of this study was to determine the incidence and distribution of five human malaria parasites including P. knowlesi in Peninsular Malaysia and Malaysian Borneo. A total of 112 blood samples were collected from seven states and district hospitals in Peninsular Malaysia and Malaysian Borneo from year 2015 to 2016. The samples were examined by microscopy and further confirmed by nested PCR assay targeting 18S rRNA gene of Plasmodium spp. Following the nested PCR assays, a total of 54 (48.2%) samples were positive for P. knowlesi infections, 12 (10.7%) cases were positive for P. vivax infections, followed by 7 (6.3%) cases of P. falciparum and 4 (3.5%) cases of P. malariae. There were 3 cases (2.7%) of mixed infections (P. knowlesi/P. vivax). However, no cases were identified as P. ovale. A total of 32 (28.6%) cases were found as negative infections. LoopMediated Isothermal Amplification Assay (LAMP) was performed to confirm inconclusive results produced by microscopy and nested PCR. P. knowlesi showed the highest prevalence in Sarawak (n= 30), Sabah (n=13), Pulau Pinang (n=5) and Pahang (n=6). PCR and LAMP was not able to detect a large number of microscopy positive samples due to DNA degradation during storage and shipping. Among all the states involved in this study, the highest prevalence of P. knowlesi infection was found in Sabah and Sarawak.
  16. Lai MY, Abdul-Majid N, Lau YL
    Acta Parasitol, 2019 Sep;64(3):575-581.
    PMID: 31165984 DOI: 10.2478/s11686-019-00066-4
    Toxoplasma gondii is one of the most successful human pathogens. To eliminate the infection, identification of receptors or binding partners from humans is indeed urgent. T. gondii surface antigen is the ultimate component involved during the attachment of parasite into host cell. However, mechanism of invasion between SAG and host-cell membrane remains unclear. Yeast two-hybrid experiment was used to identify the binding partners from cDNA human library by using T. gondii SAG1 as bait. Mated yeast cells were plated on DDO/X plates to confirm only prey plasmid that expressing interacting protein was selected. We detected 39 clones interacted with SAG1 based on a series of the selection procedures. After colony PCR, only 29 clones were positive and subsequently sent for sequencing. The yeast plasmids for true positive clones were rescued by transformation into E. coli TOP 10F' cells. Twenty-two clones were further examined by small-scale Y2H experiment. The results indicated that a strong interaction existed between Homo sapiens lysine-rich coil-coiled and SAG1 protein, which could activate the expressions of the reporter genes in diploid yeast. Co-immunoprecipitation experiment result indicated the binding between this prey and SAG1 protein was significant (Mann-Whitney U test, Z = - 1.964, P = 0.05). H. sapiens lysine-rich coil-coiled protein was found to be interacted with SAG1. This prey protein may serve as the potential drug target in vaccination study.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links