MATERIALS AND METHODS: Seven cephalometric variables (facial angle, ANB, maxillary depth, U1/FH, FMA, IMPA, FMIA) were measured by a dentist in 60 Malay subjects (30 males and 30 females) with class I occlusion and balanced face. Two standard images were taken for each subject with conventional cephalometric radiography and MicroScribe-3DXL. All the images were traced and analysed. SPSS version 2.0 was used for statistical analysis with P-value was set at P<0.05.
RESULTS: The results revealed a significant statistic difference in four measurements (U1/FH, FMA, IMPA, FMIA) with P-value range (0.00 to 0.03). The difference in the measurements was considered clinically acceptable. The overall reliability of MicroScribe-3DXL was 92.7% and its validity was 91.8%.
CONCLUSION: The MicroScribe-3DXL is reliable and valid to most of the cephalometric variables with the advantages of saving time and cost. This is a promising device to assist in diverse areas in dental practice and research.
MATERIALS AND METHODS: Sixmaster dies were duplicated from the prepared maxillary first premolar tooth using nonprecious metal alloy (Wiron 99). Ten copings of 0.6 mm thickness were fabricated from each type of ceramic, for a total of thirty copings. Two master dies were used for each group, and each of them was used to lute five copings. All groups were cemented with resin luting cement Panavia F according to manufacturer's instructions and received a static load of 5 kg during cementation. After 24 hours of distilled water storage at 37 degrees C, the copings were vertically compressed using a universal testing machine at a crosshead speed of 1 mm/min.
RESULTS: The results of the present study showed the following mean loads at fracture: Turkom-Cera (2184 +/- 164 N), In-Ceram (2042 +/- 200 N), and Procera AllCeram (1954 +/- 211 N). ANOVA and Scheffe's post hoc test showed that the mean load at fracture of Turkom-Cera was significantly different from Procera AllCeram (p < 0.05). Scheffe's post hoc test showed no significant difference between the mean load at fracture of Turkom-Cera and In-Ceram or between the mean load at fracture of In-Ceram and Procera AllCeram.
CONCLUSION: Because Turkom-Cera demonstrated equal to or higher loads at fracture than currently accepted all-ceramic materials, it would seem to be acceptable for fabrication of anterior and posterior ceramic crowns.
MATERIALS AND METHODS: This was an interventional study involving 382 blood donors who were deferred for low hemoglobin. The donors were divided equally into two groups: a control group and the intervention group. The control group received standard management for low hemoglobin deferral, which includes a short counseling session and a 1-month course of oral iron therapy. The intervention group used a mobile application in addition to standard management. The primary endpoint was the number of blood donors who returned during the 7 months of follow-up. The secondary endpoints were the hemoglobin increment at the first visit after the donors' deferral.
RESULTS: The return rate was higher in the intervention group, with 81.2% of the donors returning in the 7 months of follow-up compared to 66% of the control group (p<0.001). Male and female donors had mean hemoglobin increments of 1.0 g/dL and 0.7 g/dL, respectively, in the intervention group, compared to decrements of 0.2 g/dL and 0.4 g/dL, respectively, in the control group (p<0.001). Multivariable analysis showed a significant association between intervention method, education level and donation status on donor return (p=0.015, p<0.001, and p<0.001, respectively).
DISCUSSION: Higher return rate and greater hemoglobin increase in the interventional group could be attributed to features in the mobile application. Repeat donors had the highest odds of returning to donate, followed by those with a tertiary level of education, and those given the mobile application. This study showed that a mobile application was effective in enhancing donor return and increasing hemoglobin level among deferred blood donors on their first return.
AIM: To evaluate the shear bond strength of Zinc phosphate cement Elite, glass ionomer cement Fuji I, resin-modified glass ionomer cement Fuji Plus and resin luting cement Panavia-F to Turkom-Cera all-ceramic material.
MATERIALS AND METHODS: Turkom-Cera was used to form discs 10mm in diameter and 3 mm in thickness (n = 40). The ceramic discs were wet ground, air - particle abraded with 50 - μm aluminium oxide particles and randomly divided into four groups (n = 10). The luting cement was bonded to Turkom-Cera discs as per manufacturer instructions. The shear bond strengths were determined using the universal testing machine at a crosshead speed of 0.5 mm/min. The data were analysed using the tests One Way ANOVA, the nonparametric Kruskal - Wallis test and Mann - Whitney Post hoc test.
RESULTS: The shear bond strength of the Elite, Fuji I, Fuji Plus and Panavia F groups were: 0.92 ± 0.42, 2.04 ± 0.78, 4.37 ± 1.18, and 16.42 ± 3.38 MPa, respectively. There was the statistically significant difference between the four luting cement tested (p < 0.05).
CONCLUSION: the phosphate-containing resin cement Panavia-F exhibited shear bond strength value significantly higher than all materials tested.
MATERIALS AND METHODS: Forty Turkom-Cera ceramic disks (10 mm × 3 mm) were prepared and randomly divided into four groups. The disks were wet ground to 1000-grit and subjected to four surface treatments: (1) No treatment (Control), (2) sandblasting, (3) silane application, and (4) sandblasting + silane. The four groups of 10 specimens each were bonded with Panavia-F resin cement according to manufacturer's recommendations. The SBS was determined using the universal testing machine (Instron) at 0.5 mm/min crosshead speed. Failure modes were recorded and a qualitative micromorphologic examination of different surface treatments was performed. The data were analyzed using the one-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests.
RESULTS: The SBS of the control, sandblasting, silane, and sandblasting + silane groups were: 10.8 ± 1.5, 16.4 ± 3.4, 16.2 ± 2.5, and 19.1 ± 2.4 MPa respectively. According to the Tukey HSD test, only the mean SBS of the control group was significantly different from the other three groups. There was no significant difference between sandblasting, silane, and sandblasting + silane groups.
CONCLUSION: In this study, the three surface treatments used improved the bond strength of resin cement to Turkom-Cera disks.
CLINICAL SIGNIFICANCE: The surface treatments used in this study appeared to be suitable methods for the cementation of glass infiltrated all-ceramic restorations.
MATERIALS AND METHODS: We retrospectively reviewed all postlingual and cross-over recipients of cochlear implants under the National Ministry of Heath CI Programme from 2009 to 2013. The outcomes measured were surgical complications and functional outcome. Surgical complications were divided into major and minor complications. Functional outcomes were measured using Categorical Auditory Performances (CAP) scale.
RESULTS: A total of 41 post-lingual and 15 cross-over patients were implanted between 2009 and 2013. The age of implantees ranged from 3.6 years to 63.2 years old. There were two major complications (3.6%), one is a case of electrode migration at three months post implantation, and six months post second implantation. Another was a case of device failure at about one-year post implantation. Both patients were reimplanted in the same ear. There was no minor complication. The CAP score for both groups (overall) showed significant improvement with 96.4% achieved CAP score of five and above at 24 months after implantation (p<0.001). The CAP score showed marked improvement at the first 6 months post implantation and continued to improve with time in both groups.
CONCLUSION: The Malaysian National Ministry of Health Cochlear implant (CI) Program between 2009-2013 has been a successful programme with good surgical and functional outcomes among the post lingual and cross-over patients.
METHODS: The norm-referenced method of standard setting was applied to the real scores of 40 final-year dental students on a multiple-choice question (MCQ), a short answer question (SAQ), and an objective structured clinical examination (OSCE). A panel of 10 judges set the standard using the modified-Angoff method for the same paper in one sitting. One judge set the passing score of 10 OSCE questions after 2 weeks. A comparison of the grades and pass/fail rates derived from the absolute standard, norm-referenced, and modified-Angoff methods was made. The intra-rater and inter-rater reliabilities of the modified-Angoff method were assessed.
RESULTS: The passing rate for the absolute standard was 100% (40/40), for the norm-referenced method it was 62.5% (25/40), and for the modified-Angoff method it was 80% (32/40). The modified-Angoff method had good inter-rater reliability of 0.876 and excellent test-retest reliability of 0.941.
CONCLUSION: There were significant differences in the outcomes of these three standard-setting methods, as shown by the difference in the proportion of candidates who passed and failed the assessment. The modified-Angoff method was found to have good reliability for use with a professional qualifying dental examination.
METHODS: A cross-sectional study was conducted among academic health professionals via web-based professional networks from August 2022 to February 2023. Validated tools were used, and descriptive and inferential statistics were applied.
RESULTS: 505 participants were included, predominantly female (63%), with a mean age of 38.15 ± 9.6 years. High burnout was reported by 10.9%, 13.7% experienced exhaustion, and 6.3% were disengaged. Resilience and thriving were moderate at 59.2 and 51.9%, respectively. Age correlated negatively with burnout (r = -0.131, p = 0.003) but positively with resilience (r = 0.178, p
METHODS: This retrospective study included 153 Muslim patients with MS. Data related to the disease course before Ramadan were obtained from patients' files, whereas data related to the disease activity during Ramadan, were collected from patients over the two months following Ramadan.
RESULTS: Patients with MS who experienced relapses, exacerbation of symptoms and development of new symptoms during Ramadan had a statistically significant longer disease duration compared to those who did not experience (P < 0.001, <0.001, 0.01 respectively). Also, patients who experienced relapses, exacerbation of symptoms and development of new symptoms during Ramadan had a statistically significant higher expanded disability status scale (EDSS) compared to those who did not experience (P <0.001, <0.001,0.01, respectively). The occurrence of relapses, exacerbation of symptoms and development of new symptoms during Ramadan, were significantly higher in patients who experienced relapses in the preceding year compared to those who did not (P= 0.002, 0.002, 0.01, respectively). Binary logistic regression revealed that each score elevation of EDSS increased the odds of relapse during Ramadan by 1.02 (P-value = 0.04). Also, each month's increase in disease duration increased the odds of relapse during Ramadan by 1.87 (P-value = 0.046).
CONCLUSION: High EDSS and long disease duration are independent predictors of relapse during Ramadan.