Displaying publications 1 - 20 of 283 in total

Abstract:
Sort:
  1. Siar CH, Ng KH
    Br J Oral Maxillofac Surg, 1993 Jun;31(3):183-6.
    PMID: 7685634
    Four cases of either combined occurrence of ameloblastoma and odontogenic keratocyst or a rare keratinising variant of ameloblastoma are presented. The cardinal histomorphologic characteristics are simultaneous occurrence of ameloblastomatous epithelial islands with central keratinisation and multiple keratinising cysts. Immunohistochemically the tumour elements were keratin positive and occasionally S-100 protein and desmin positive. Major differential diagnosis of these neoplasms are discussed.
  2. Tsapaki V, Ibbott G, Krisanachinda A, Ng KH, Suh TS, Tabakov S, et al.
    Phys Med, 2017 Dec;44:196-198.
    PMID: 29221890 DOI: 10.1016/j.ejmp.2017.11.022
    As medical technology evolves and patient needs increase, the need for well-trained and highly professional medical physicists (MPs) becomes even more urgent. The roles and responsibilities of MPs in various departments within the hospital are diverse and demanding. It is obvious that training, continuing education and professional development of MPs have become essential. One of the ways for an MP to advance his or her knowledge is to participate in conferences and congresses. Last year, the 22nd International Conference of Medical Physics (ICMP 2016) took place in Bangkok, Thailand. The event attracted 584 delegates with most of the participants coming from Asia. It attracted also delegates from 42 countries. The largest delegations were from Thailand, Japan and South Korea. ICMP 2016 included 367 oral presentations and e-posters, most of these being in the fields of Radiation Therapy, Medical Imaging and Radiation Safety. All abstracts were published as an e-book of Abstracts in a supplement to the official IOMP Journal. Many companies had exhibition stands at ICMP2016, thus allowing the participants to see the latest developments in the medical physics-related industry. The conference included 42 mini-symposia, part of the first "IOMP School" activity, covering various topics of importance for the profession and this special issue follows from the success of the conference.
  3. Mun PS, Ting HN, Ong TA, Wong CM, Ng KH, Chong YB
    PLoS One, 2015;10(6):e0130011.
    PMID: 26066351 DOI: 10.1371/journal.pone.0130011
    This paper investigates the dielectric properties of urine in normal subjects and subjects with chronic kidney disease (CKD) at microwave frequency of between 0.2 GHz and 50 GHz. The measurements were conducted using an open-ended coaxial probe at room temperature (25°C), at 30°C and at human body temperature (37°C). There were statistically significant differences in the dielectric properties of the CKD subjects compared to those of the normal subjects. Statistically significant differences in dielectric properties were observed across the temperatures for normal subjects and CKD subjects. Pearson correlation test showed the significant correlation between proteinuria and dielectric properties. The experimental data closely matched the single-pole Debye model. The relaxation dispersion and relaxation time increased with the proteinuria level, while decreasing with the temperature. As for static conductivity, it increased with proteinuria level and temperature.
  4. Ng KH, Siar CH
    J Nihon Univ Sch Dent, 1997 Dec;39(4):171-5.
    PMID: 9476429
    This report reviews the clinicopathologic characteristics of 104 cases of odontomas diagnosed in the Division of Stomatology, Institute for Medical Research, Kuala Lumpur, over a 29-year period (1967-1995). The results showed no real predilection in terms of sex (M:F ratio, 1:1), race (45.2% Malays, 40.4% Chinese, 10.6% Indians and 3.8% other races) or site (maxilla:mandible ratio, 1: 1.04) distribution. The mean age at presentation was 24.8 years and the age range was 3-74 years. There were 102 intraosseous and 2 extraosseous odontomas. Swelling was the most common presenting complaint. The majority of cases (81.9%) were clinically diagnosed as odontomas. The treatment of choice was surgical enucleation. Compound (43.3%) and complex (35.5%) odontomas were the two most common histological types encountered. The present findings correlate favorably with reported studies from other geographic areas.
  5. Ng KH, Siar CH
    J Laryngol Otol, 1996 Aug;110(8):757-62.
    PMID: 8869610
    We reviewed the clinicopathological characteristics of 13 cases of calcifying epithelial odontogenic tumour (CEOT) (Pindborg tumour) diagnosed in the Division on Stomatology, Institute for Medical Research, Kuala Lumpur, over a 29-year period. There were eight female and five male patients. These consisted of eight (61.5 per cent) Malays, three (23.1 per cent) Chinese, one (7.7 per cent) Indian and one (7.7 per cent) Melanau. Their ages at presentation ranged from 19-61 years (mean age, 31.8 years). There were 12 central and one peripheral CEOT. Of these, 76.9 per cent of cases were located in the maxilla, the remaining in the mandible. The commonest clinical diagnosis was a dentigerous cyst (66.7 per cent). Enucleation was the main mode of treatment. Histologically, sheets and strands of polyhedral epithelial cells containing eosinophilic, homogeneous globules with Liesegang rings were observed. One case also showed extensive calcification and clear cell differentiation. Immunohistochemistry revealed a variable keratin staining of the CEOT epithelium, confirming its heterogeneity.
  6. Karim MKA, Sabarudin A, Muhammad NA, Ng KH
    Radiol Phys Technol, 2019 Dec;12(4):374-381.
    PMID: 31468370 DOI: 10.1007/s12194-019-00532-8
    This study aimed to evaluate effective dose and size-specific dose estimate (SSDE) of computed tomography angiography (CTA) examination using an anthropomorphic phantom. We included three CTA examination protocols to evaluate the intra- and extra-cranial arteries, pulmonary artery (CTPA), and abdominal vessels. Patient SSDEs were measured retrospectively to estimate patient dose, relative to the bodyweight of the patient and volume CT dose index (CTDIvol). Our findings revealed that the highest dose was absorbed by the left lobe of the thyroid gland during intra-/extra-cranial CTA and CTPA, that is, 14.11 ± 0.24 mGy and 16.20 ± 3.95 mGy, respectively. However, the highest absorbed dose in abdominal/pelvic CTA was the gonads (8.98 ± 0.30 mGy), while other radiosensitive organs in intra- and extra-cranial CTA, CTPA, and abdominal/pelvic CTA did not demonstrate significant differences between organs/structures with p value 0.88, 0.11, and 0.54, respectively. The estimated effective dose in intra-/extra-cranial CTA was lower in patients (0.80 ± 0.60 mSv) than in the phantom (0.83 mSv), but it was the opposite for CTPA, with the effective dose being higher in patients (7.54 ± 3.09 mSv) than in the phantom (6.68 mSv). Similar to the effective dose, only CTPA SSDEs were significantly higher in men than in women (19.74 ± 4.79 mGy versus 7.9 mGy). Effective dose and SSDE are clinically relevant parameters that can help estimate a more accurate patient dose based on a patient's size.
  7. Lam S, Bux S, Kumar G, Ng Kh, Hussain A
    Biomed Imaging Interv J, 2009 Jul;5(3):e13.
    PMID: 21611051 MyJurnal DOI: 10.2349/biij.5.3.e13
    To compare the image quality of the low-dose to the standard-dose protocol of MDCT scanning of the paranasal sinuses, based on subjective assessment and determine the radiation doses to the eyes and thyroid gland and dose reduction between these two protocols.
  8. Ng KH, Ho CK, Phon-Amnuaisuk S
    PLoS One, 2012;7(10):e47216.
    PMID: 23071763 DOI: 10.1371/journal.pone.0047216
    Clustering is a key step in the processing of Expressed Sequence Tags (ESTs). The primary goal of clustering is to put ESTs from the same transcript of a single gene into a unique cluster. Recent EST clustering algorithms mostly adopt the alignment-free distance measures, where they tend to yield acceptable clustering accuracies with reasonable computational time. Despite the fact that these clustering methods work satisfactorily on a majority of the EST datasets, they have a common weakness. They are prone to deliver unsatisfactory clustering results when dealing with ESTs from the genes derived from the same family. The root cause is the distance measures applied on them are not sensitive enough to separate these closely related genes.
  9. Azlan CA, Mohd Nasir NF, Saifizul AA, Faizul MS, Ng KH, Abdullah BJ
    Australas Phys Eng Sci Med, 2007 Dec;30(4):288-91.
    PMID: 18274069
    Percutaneous image-guided needle biopsy is typically performed in highly vascular organs or in tumours with rich macroscopic and microscopic blood supply. The main risks related to this procedure are haemorrhage and implantation of tumour cells in the needle tract after the biopsy needle is withdrawn. From numerous conducted studies, it was found that heating the needle tract using alternating current in radiofrequency (RF) range has a potential to minimize these effects. However, this solution requires the use of specially designed needles, which would make the procedure relatively expensive and complicated. Thus, we propose a simple solution by using readily available coaxial core biopsy needles connected to a radiofrequency ablation (RFA) generator. In order to do so, we have designed and developed an adapter to interface between these two devices. For evaluation purpose, we used a bovine liver as a sample tissue. The experimental procedure was done to study the effect of different parameter settings on the size of coagulation necrosis caused by the RF current heating on the subject. The delivery of the RF energy was varied by changing the values for delivered power, power delivery duration, and insertion depth. The results showed that the size of the coagulation necrosis is affected by all of the parameters tested. In general, the size of the region is enlarged with higher delivery of RF power, longer duration of power delivery, and shallower needle insertion and become relatively constant after a certain value. We also found that the solution proposed provides a low cost and practical way to minimizes unwanted post-biopsy effects.
  10. Ng AH, Ng KH, Dharmendra H, Perkins AC
    Appl Radiat Isot, 2009 Oct;67(10):1864-8.
    PMID: 19049851 DOI: 10.1016/j.apradiso.2008.10.010
    A simple sphere test phantom has been developed for routine performance testing of SPECT systems in situations where expensive commercial phantoms may not be available. The phantom was based on a design with six universal syringe hubs set in the frame to support a circular array of six glass blown spheres of different sizes. The frame was then placed into a water-filled CT abdomen phantom and scanned with a triple head camera system (Philips IRIX, USA). Comparison was made with a commercially available phantom (Deluxe Jaszczak phantom). Whereas the commercial phantom demonstrates cold spot resolution, an important advantage of the sphere test phantom was that hot spot resolution could be easily measured using almost half (370MBq) of the activity recommended for use in the commercial phantom. Results showed that the contrast increased non-linearly with sphere volume and radionuclide concentration. The phantom was found to be suitable as an inexpensive option for daily performance tests.
  11. Tan LK, Wong JH, Ng KH
    AJR Am J Roentgenol, 2006 Mar;186(3):898-901.
    PMID: 16498128
    The purpose of this article was to develop a low-cost method for high-quality remote capturing and recording of multimedia presentations.
  12. Zourmand A, Mirhassani SM, Ting HN, Bux SI, Ng KH, Bilgen M, et al.
    Biomed Eng Online, 2014;13:103.
    PMID: 25060583 DOI: 10.1186/1475-925X-13-103
    The phonetic properties of six Malay vowels are investigated using magnetic resonance imaging (MRI) to visualize the vocal tract in order to obtain dynamic articulatory parameters during speech production. To resolve image blurring due to the tongue movement during the scanning process, a method based on active contour extraction is used to track tongue contours. The proposed method efficiently tracks tongue contours despite the partial blurring of MRI images. Consequently, the articulatory parameters that are effectively measured as tongue movement is observed, and the specific shape of the tongue and its position for all six uttered Malay vowels are determined.Speech rehabilitation procedure demands some kind of visual perceivable prototype of speech articulation. To investigate the validity of the measured articulatory parameters based on acoustic theory of speech production, an acoustic analysis based on the uttered vowels by subjects has been performed. As the acoustic speech and articulatory parameters of uttered speech were examined, a correlation between formant frequencies and articulatory parameters was observed. The experiments reported a positive correlation between the constriction location of the tongue body and the first formant frequency, as well as a negative correlation between the constriction location of the tongue tip and the second formant frequency. The results demonstrate that the proposed method is an effective tool for the dynamic study of speech production.
  13. Woo MK, Ng KH
    J Med Internet Res, 2003 Jan-Mar;5(1):e3.
    PMID: 12746208
    Medical physics is a relatively small community but it spans great geographical distances, usually with a scarcity of experts whose expertise could greatly benefit students entering into the field. In addition there are many software systems for which an interactive education method would be most advantageous.
  14. Tan M, Mariapun S, Yip CH, Ng KH, Teo SH
    Phys Med Biol, 2019 01 31;64(3):035016.
    PMID: 30577031 DOI: 10.1088/1361-6560/aafabd
    Historically, breast cancer risk prediction models are based on mammographic density measures, which are dichotomous in nature and generally categorize each voxel or area of the breast parenchyma as 'dense' or 'not dense'. Using these conventional methods, the structural patterns or textural components of the breast tissue elements are not considered or ignored entirely. This study presents a novel method to predict breast cancer risk that combines new texture and mammographic density based image features. We performed a comprehensive study of the correlation of 944 new and conventional texture and mammographic density features with breast cancer risk on a cohort of Asian women. We studied 250 breast cancer cases and 250 controls matched at full-field digital mammography (FFDM) status for age, BMI and ethnicity. Stepwise regression analysis identified relevant features to be included in a linear discriminant analysis (LDA) classifier model, trained and tested using a leave-one-out based cross-validation method. The area under the receiver operating characteristic (AUC) and adjusted odds ratios (ORs) were used as the two performance assessment indices in our study. For the LDA trained classifier, the adjusted OR was 6.15 (95% confidence interval: 3.55-10.64) and for Volpara volumetric breast density, 1.10 (0.67-1.81). The AUC for the LDA trained classifier was 0.68 (0.64-0.73), compared to 0.52 (0.47-0.57) for Volpara volumetric breast density (p   
  15. Lim CK, Yew KM, Ng KH, Abdullah BJ
    Australas Phys Eng Sci Med, 2002 Sep;25(3):144-50.
    PMID: 12416592 DOI: 10.1007/BF03178776
    Development of computer-based medical inference systems is always confronted with some difficulties. In this paper, difficulties of designing an inference system for the diagnosis of arthritic diseases are described, including variations of disease manifestations under various situations and conditions. Furthermore, the need for a huge knowledge base would result in low efficiency of the inference system. We proposed a hierarchical model of the fuzzy inference system as a possible solution. With such a model, the diagnostic process is divided into two levels. The first level of the diagnosis reduces the scope of diagnosis to be processed by the second level. This will reduce the amount of input and mapping for the whole diagnostic process. Fuzzy relational theory is the core of this system and it is used in both levels to improve the accuracy.
  16. Ng KH, Lai SY, Jamaludin NFM, Mohamed AR
    J Hazard Mater, 2022 Feb 05;423(Pt A):127061.
    PMID: 34788939 DOI: 10.1016/j.jhazmat.2021.127061
    While sulphur dioxide (SO2) is known for its toxicity, numerous effective countermeasures were innovated to alleviate its hazards towards the environment. In particular, catalytic reduction is favoured for its potential in converting SO2 into harmless, yet marketable product, such as elemental sulphur. Therefore, current review summarises the critical findings in catalytic SO2 reduction, emphasising on both dry- and wet-based technology. As for the dry-based technology, knowledge related to SO2 reduction over metal-, rare earth- and carbon-based catalysts are summarised. Significantly, both the reduction mechanisms and important criteria for efficient SO2 reduction are elucidated too. Meanwhile, the wet-based SO2 reduction are typically conducted in reactive liquid medium, such as metal complexes, ionic liquids and organic solvents. Therefore, the applications of the aforesaid liquid mediums are discussed thoroughly in the similar manner to dry-technology. Additionally, the pros and cons of each type of catalyst are also presented to provide valuable insights to the pertinent researchers. Finally, some overlooked aspects in both dry- and wet-based SO2 reduction are identified, with potential solutions given too. With these insights, current review is anticipated to contribute towards practicality improvement of catalytic SO2 reduction, which in turn, protects the environment from SO2 pollution.
  17. Zhu CZ, Ting HN, Ng KH, Ong TA
    J Cancer, 2019;10(17):4038-4044.
    PMID: 31417648 DOI: 10.7150/jca.28989
    Background and purpose: Bladder cancer is the most common malignant tumour in the urinary system, with a high incidence and recurrence rate. While the incidence of bladder cancer has been rising in recent years, the prevalence of bladder carcinoma is showing an increasing tendency in the younger age group. There are several methods to detect bladder cancer, but different methods have varying degrees of accuracy which intrinsically depends on the method's sensitivity and specificity. Our aim was to comprehensively summarize the current detection methods for bladder cancer based on the available literature, and at the same time, to find the best combination of different effective methods which can produce a high degree of accuracy in detecting the presence of cancerous cells in the bladder. Materials and Methods: We used key word retrieval method for searching related references in English that had been indexed in PubMed and Medline. Results and Discussion: This paper discussed the different detection methods and their sensitivities/specificities as well as the advantages and disadvantages. We summarized the best identified cancer cell detection methods with higher sensitivity/specificity. Conclusion: The results of this review can positively help to identify accurate methods for detecting bladder cancer and highlight areas to be further improved for future research work.
  18. Jamal N, Ng KH, McLean D
    Br J Radiol, 2003 Apr;76(904):238-45.
    PMID: 12711643
    The primary objective of this study was to determine the mean glandular dose (MGD) during diagnostic mammography in Malaysia. The secondary objective was to evaluate some of the factors affecting MGD. A survey of standard MGD was performed, based upon quality control records for the period October 1999 to August 2001. This covered 30 mammography units from 9 manufacturers. MGD was also measured for a series of patients attending mammography examinations at three other mammography units. MGD per film was estimated from recorded radiographic factors, the compressed breast thickness (CBT) and X-ray unit calibration data. MGD per woman was calculated by summing the MGDs for all films, and averaging it over both breasts. 300 women drawn equally from three major ethnic groups, namely Malay, Chinese and Indian, took part in the study. The difference of MGD per woman between ethnic groups was tested for significance using non-parametric Kruskal-Wallis and median tests. The factors affecting MGD per woman were tested for significance using a multivariate analysis of variance. The MGD for the phantom was 1.23 mGy (range 0.22-2.39 mGy) while the mean patient based MGD per film was 1.54 mGy and 1.82 mGy for the craniocaudal and mediolateral oblique views, respectively. The mean MGD per woman was 3.37 mGy. It was also found that there is no significant difference in MGD per woman among the ethnic groups (p>0.05, Kruskal-Wallis test). However, on the multivariate test two factors, namely half value layer of the X-ray beam and (CBT), had a significant effect on MGD per woman (p<0.05). No significant relationships were seen between MGD per woman with respect to ethnicity, body mass index or age.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links