Displaying publications 1 - 20 of 154 in total

Abstract:
Sort:
  1. Mortaza N, Abu Osman NA, Mehdikhani N
    Eur J Phys Rehabil Med, 2014 Dec;50(6):677-91.
    PMID: 24831570
    Fall is a common and a major cause of injuries. It is important to find elderlies who are prone to falls. The majority of serious falls occur during walking among the older adults. Analyzing the spatio-temporal parameters of walking is an easy way of assessment in the clinical setting, but is it capable of distinguishing a faller from a non-faller elderly? Through a systematic review of the literature, the objective of this systematic review was to identify and summarize the differences in the spatio-temporal parameters of walking in elderly fallers and non-fallers and to find out if these parameters are capable of distinguishing a faller from a non-faller. All original research articles which compared any special or temporal walking parameters in faller and non-faller elderlies were systematically searched within the Scopus and Embase databases. Effect size analysis was also done to standardize findings and compare the gait parameters of fallers and non-fallers across the selected studies. The electronic search led to 5381 articles. After title and abstract screening 30 articles were chosen; further assessment of the full texts led to 17 eligible articles for inclusion in the review. It seems that temporal measurements are more sensitive to the detection of risk of fall in elderly people. The results of the 17 selected studies showed that fallers have a tendency toward a slower walking speed and cadence, longer stride time, and double support duration. Also, fallers showed shorter stride and step length, wider step width and more variability in spatio-temporal parameters of gait. According to the effect size analysis, step length, gait speed, stride length and stance time variability were respectively more capable of differentiating faller from non-faller elderlies. However, because of the difference of methodology and number of studies which investigated each parameter, these results are prone to imprecision. Spatio-temporal analysis of level walking is not sufficient and cannot act as a reliable predictor of falls in elderly individuals.
  2. Jusman Y, Ng SC, Abu Osman NA
    ScientificWorldJournal, 2014;2014:289817.
    PMID: 25610902 DOI: 10.1155/2014/289817
    This paper investigated the effects of critical-point drying (CPD) and hexamethyldisilazane (HMDS) sample preparation techniques for cervical cells on field emission scanning electron microscopy and energy dispersive X-ray (FE-SEM/EDX). We investigated the visualization of cervical cell image and elemental distribution on the cervical cell for two techniques of sample preparation. Using FE-SEM/EDX, the cervical cell images are captured and the cell element compositions are extracted for both sample preparation techniques. Cervical cell image quality, elemental composition, and processing time are considered for comparison of performances. Qualitatively, FE-SEM image based on HMDS preparation technique has better image quality than CPD technique in terms of degree of spread cell on the specimen and morphologic signs of cell deteriorations (i.e., existence of plate and pellet drying artifacts and membrane blebs). Quantitatively, with mapping and line scanning EDX analysis, carbon and oxygen element compositions in HMDS technique were higher than the CPD technique in terms of weight percentages. The HMDS technique has shorter processing time than the CPD technique. The results indicate that FE-SEM imaging, elemental composition, and processing time for sample preparation with the HMDS technique were better than CPD technique for cervical cell preparation technique for developing computer-aided screening system.
  3. Jusman Y, Ng SC, Abu Osman NA
    ScientificWorldJournal, 2014;2014:810368.
    PMID: 24955419 DOI: 10.1155/2014/810368
    Advent of medical image digitalization leads to image processing and computer-aided diagnosis systems in numerous clinical applications. These technologies could be used to automatically diagnose patient or serve as second opinion to pathologists. This paper briefly reviews cervical screening techniques, advantages, and disadvantages. The digital data of the screening techniques are used as data for the computer screening system as replaced in the expert analysis. Four stages of the computer system are enhancement, features extraction, feature selection, and classification reviewed in detail. The computer system based on cytology data and electromagnetic spectra data achieved better accuracy than other data.
  4. Mohd Safee MK, Abu Osman NA
    Occup Ther Int, 2021;2021:4357473.
    PMID: 34707468 DOI: 10.1155/2021/4357473
    Muscle fatigue is a decline in muscle maximum force during contraction and can influence the fall risk among people. This study is aimed at identifying the effect of fatigue on prospective fall risk in transfemoral amputees (TFA). Fourteen subjects were involved in this study with TFA (34.7 ± 8.1 yrs, n = 7) and normal subjects (31.1 ± 7.4 yrs, n = 7). Fatigue of lower limb muscles was induced with the fatigue protocol. Subjects were tested prefatigue and postfatigue using the standardized fall risk assessment. All results were calculated and compared between pre- and postfatigue to identify fatigue's effect on both groups of subjects. The results showed that the fall risk increased significantly during pre- and postfatigue for TFA (p = 0.018), while there were no significant differences in normal subjects (p = 0.149). Meanwhile, the fall risk between TFA and normal subjects for prefatigue (p = 0.082) and postfatigue (p = 0.084) also showed no significant differences. The percentage (%) of increased fall risk for TFA was 19.2% compared to normal subjects only 16.7%. However, 61.4% increased of % fall risk in TFA after fatigue by using the baseline of the normal subject as the normalized % of fall risk. The increasing fall risks for TFA after fatigue are three times higher than the potential fall risk in normal subjects. The result indicates that they need to perform more precautions while prolonging lower limb activities. These results showed the implications of fatigue that can increase the fall risk due to muscle fatigue from repetitive and prolonged activities. Therefore, rehabilitation programs can be done very safely and precisely so that therapists can pursue fitness without aggravating existing injuries.
  5. Moo EK, Osman NA, Pingguan-Murphy B
    Clinics (Sao Paulo), 2011;66(8):1431-6.
    PMID: 21915496
    INTRODUCTION: Although previous studies have been performed on cartilage explant cultures, the generalized dynamics of cartilage metabolism after extraction from the host are still poorly understood due to differences in the experimental setups across studies, which in turn prevent building a complete picture.

    METHODS: In this study, we investigated the response of cartilage to the trauma sustained during extraction and determined the time needed for the cartilage to stabilize. Explants were extracted aseptically from bovine metacarpal-phalangeal joints and cultured for up to 17 days.

    RESULTS: The cell viability, cell number, proteoglycan content, and collagen content of the harvested explants were analyzed at 0, 2, 10, and 17 days after explantation. A high percentage of the cartilage explants were found to be viable. The cell density initially increased significantly but stabilized after two days. The proteoglycan content decreased gradually over time, but it did not decrease to a significant level due to leakage through the distorted peripheral collagen network and into the bathing medium. The collagen content remained stable for most of the culture period until it dropped abruptly on day 17.

    CONCLUSION: Overall, the tested cartilage explants were sustainable over long-term culture. They were most stable from day 2 to day 10. The degradation of the collagen on day 17 did not reach diseased levels, but it indicated the potential of the cultures to develop into degenerated cartilage. These findings have implications for the application of cartilage explants in pathophysiological fields.

  6. Daneshjoo A, Abu Osman NA, Sahebozamani M, Yusof A
    PLoS One, 2015;10(11):e0143323.
    PMID: 26599336 DOI: 10.1371/journal.pone.0143323
    PURPOSE: Running at high speed and sudden change in direction or activity stresses the knee. Surprisingly, not many studies have investigated the effects of sprinting on knee's kinetics and kinematics of soccer players. Hence, this study is aimed to investigate indices of injury risk factors of jumping-landing maneuvers performed immediately after sprinting in male soccer players.

    METHODS: Twenty-three collegiate male soccer players (22.1±1.7 years) were tested in four conditions; vertical jump (VJ), vertical jump immediately after slow running (VJSR), vertical jump immediately after sprinting (VJFR) and double horizontal jump immediately after sprinting (HJFR). The kinematics and kinetics data were measured using Vicon motion analyzer (100Hz) and two Kistler force platforms (1000Hz), respectively.

    RESULTS: For knee flexion joint angle, (p = 0.014, η = 0.15) and knee valgus moment (p = 0.001, η = 0.71) differences between condition in the landing phase were found. For knee valgus joint angle, a main effect between legs in the jumping phase was found (p = 0.006, η = 0.31), which suggests bilateral deficit existed between the right and left lower limbs.

    CONCLUSION: In brief, the important findings were greater knee valgus moment and less knee flexion joint angle proceeding sprint (HJFR & VJFR) rather than no sprint condition (VJ) present an increased risk for knee injuries. These results seem to suggest that running and sudden subsequent jumping-landing activity experienced during playing soccer may negatively change the knee valgus moment. Thus, sprinting preceding a jump task may increase knee risk factors such as moment and knee flexion joint angle.

  7. El-Sayed AM, Hamzaid NA, Abu Osman NA
    Sensors (Basel), 2014;14(12):23724-41.
    PMID: 25513823 DOI: 10.3390/s141223724
    Alternative sensory systems for the development of prosthetic knees are being increasingly highlighted nowadays, due to the rapid advancements in the field of lower limb prosthetics. This study presents the use of piezoelectric bimorphs as in-socket sensors for transfemoral amputees. An Instron machine was used in the calibration procedure and the corresponding output data were further analyzed to determine the static and dynamic characteristics of the piezoelectric bimorph. The piezoelectric bimorph showed appropriate static operating range, repeatability, hysteresis, and frequency response for application in lower prosthesis, with a force range of 0-100 N. To further validate this finding, an experiment was conducted with a single transfemoral amputee subject to measure the stump/socket pressure using the piezoelectric bimorph embedded inside the socket. The results showed that a maximum interface pressure of about 27 kPa occurred at the anterior proximal site compared to the anterior distal and posterior sites, consistent with values published in other studies. This paper highlighted the capacity of piezoelectric bimorphs to perform as in-socket sensors for transfemoral amputees. However, further experiments are recommended to be conducted with different amputees with different socket types.
  8. Razak NA, Osman NA, Gholizadeh H, Ali S
    Biomed Eng Online, 2014;13:108.
    PMID: 25085005 DOI: 10.1186/1475-925X-13-108
    The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system.
  9. Tripathy A, Pramanik S, Cho J, Santhosh J, Osman NA
    Sensors (Basel), 2014;14(9):16343-422.
    PMID: 25256110 DOI: 10.3390/s140916343
    The humidity sensing characteristics of different sensing materials are important properties in order to monitor different products or events in a wide range of industrial sectors, research and development laboratories as well as daily life. The primary aim of this study is to compare the sensing characteristics, including impedance or resistance, capacitance, hysteresis, recovery and response times, and stability with respect to relative humidity, frequency, and temperature, of different materials. Various materials, including ceramics, semiconductors, and polymers, used for sensing relative humidity have been reviewed. Correlations of the different electrical characteristics of different doped sensor materials as the most unique feature of a material have been noted. The electrical properties of different sensor materials are found to change significantly with the morphological changes, doping concentration of different materials and film thickness of the substrate. Various applications and scopes are pointed out in the review article. We extensively reviewed almost all main kinds of relative humidity sensors and how their electrical characteristics vary with different doping concentrations, film thickness and basic sensing materials. Based on statistical tests, the zinc oxide-based sensing material is best for humidity sensor design since it shows extremely low hysteresis loss, minimum response and recovery times and excellent stability.
  10. Ali S, Osman NA, Razak A, Hussain S, Wan Abas WA
    Eur J Phys Rehabil Med, 2015 Feb;51(1):31-7.
    PMID: 24963603
    Lower limb amputee's are greatly affected in dealing with the environmental barriers such as ramps and stairs and reported high interface pressure between the residual limb and socket/liner. Interface pressure between the residual limb and socket/liner can affect the satisfaction and use of the prosthesis. Until now, little attention has been paid to interface pressure between socket and stump during ramp negotiation and its effect on amputee's satisfaction.
  11. Farzadi A, Solati-Hashjin M, Asadi-Eydivand M, Abu Osman NA
    PLoS One, 2014;9(9):e108252.
    PMID: 25233468 DOI: 10.1371/journal.pone.0108252
    Powder-based inkjet 3D printing method is one of the most attractive solid free form techniques. It involves a sequential layering process through which 3D porous scaffolds can be directly produced from computer-generated models. 3D printed products' quality are controlled by the optimal build parameters. In this study, Calcium Sulfate based powders were used for porous scaffolds fabrication. The printed scaffolds of 0.8 mm pore size, with different layer thickness and printing orientation, were subjected to the depowdering step. The effects of four layer thicknesses and printing orientations, (parallel to X, Y and Z), on the physical and mechanical properties of printed scaffolds were investigated. It was observed that the compressive strength, toughness and Young's modulus of samples with 0.1125 and 0.125 mm layer thickness were more than others. Furthermore, the results of SEM and μCT analyses showed that samples with 0.1125 mm layer thickness printed in X direction have more dimensional accuracy and significantly close to CAD software based designs with predefined pore size, porosity and pore interconnectivity.
  12. Pramanik S, Pingguan-Murphy B, Cho J, Abu Osman NA
    Sci Rep, 2014 Jul 28;4:5843.
    PMID: 25068570 DOI: 10.1038/srep05843
    The complex architecture of the cortical part of the bovine-femur was examined to develop potential tissue engineering (TE) scaffolds. Weight-change and X-ray diffraction (XRD) results show that significant phase transformation and morphology conversion of the bone occur at 500-750°C and 750-900°C, respectively. Another breakthrough finding was achieved by determining a sintering condition for the nucleation of hydroxyapatite crystal from bovine bone via XRD technique. Scanning electron microscopy results of morphological growth suggests that the concentration of polymer fibrils increases (or decreases, in case of apatite crystals) from the distal to proximal end of the femur. Energy-dispersive analysis of X-ray, Fourier transform infrared, micro-computer tomography, and mechanical studies of the actual composition also strongly support our microscopic results and firmly indicate the functionally graded material properties of bovine-femur. Bones sintered at 900 and 1000°C show potential properties for soft and hard TE applications, respectively.
  13. Gholizadeh H, Osman NA, Eshraghi A, Abd Razak NA
    Biomed Eng Online, 2014;13:89.
    PMID: 24981801 DOI: 10.1186/1475-925X-13-89
    Prosthesis suspension systems can alter the distribution of pressure within the prosthetic socket. This study evaluates a new suspension system for lower limb prostheses, and aims to compare the interface pressure and amputees' satisfaction with the new system compared with a common prosthetic suspension system (pin/lock).
  14. El-Sayed AM, Hamzaid NA, Abu Osman NA
    ScientificWorldJournal, 2014;2014:297431.
    PMID: 25110727 DOI: 10.1155/2014/297431
    Several studies have presented technological ensembles of active knee systems for transfemoral prosthesis. Other studies have examined the amputees' gait performance while wearing a specific active prosthesis. This paper combined both insights, that is, a technical examination of the components used, with an evaluation of how these improved the gait of respective users. This study aims to offer a quantitative understanding of the potential enhancement derived from strategic integration of core elements in developing an effective device. The study systematically discussed the current technology in active transfemoral prosthesis with respect to its functional walking performance amongst above-knee amputee users, to evaluate the system's efficacy in producing close-to-normal user performance. The performances of its actuator, sensory system, and control technique that are incorporated in each reported system were evaluated separately and numerical comparisons were conducted based on the percentage of amputees' gait deviation from normal gait profile points. The results identified particular components that contributed closest to normal gait parameters. However, the conclusion is limitedly extendable due to the small number of studies. Thus, more clinical validation of the active prosthetic knee technology is needed to better understand the extent of contribution of each component to the most functional development.
  15. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S
    PLoS One, 2014;9(5):e94520.
    PMID: 24827560 DOI: 10.1371/journal.pone.0094520
    The suction sockets that are commonly prescribed for transtibial amputees are believed to provide a better suspension than the pin/lock systems. Nevertheless, their effect on amputees' gait performance has not yet been fully investigated. The main intention of this study was to understand the potential effects of the Seal-in (suction) and the Dermo (pin/lock) suspension systems on amputees' gait performance.
  16. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S
    Am J Phys Med Rehabil, 2014 Sep;93(9):809-23.
    PMID: 24743451 DOI: 10.1097/PHM.0000000000000094
    The purpose of this study was to find the scientific evidence pertaining to various transfemoral suspension systems to provide selection criteria for clinicians. To this end, databases of PubMed, Web of Science, and ScienceDirect were explored. The following key words, as well as their combinations and synonyms, were used for the search: transfemoral prosthesis, prosthetic suspension, lower limb prosthesis, above-knee prosthesis, prosthetic liner, transfemoral, and prosthetic socket. The study design, research instrument, sampling method, outcome measures, and protocols of articles were reviewed. On the basis of the selection criteria, 16 articles (11 prospective studies and 5 surveys) were reviewed. The main causes of reluctance to prosthesis, aside from energy expenditure, were socket-related problems such as discomfort, perspiration, and skin problems. Osseointegration was a suspension option, yet it is rarely applied because of several drawbacks, such as extended rehabilitation process, risk for fracture, and infection along with excessive cost. In conclusion, no clinical evidence was found as a "standard" system of suspension and socket design for all transfemoral amputees. However, among various suspension systems for transfemoral amputees, the soft insert or double socket was favored by most users in terms of function and comfort.
  17. Das NS, Usman J, Choudhury D, Abu Osman NA
    PLoS One, 2014;9(6):e100028.
    PMID: 24927127 DOI: 10.1371/journal.pone.0100028
    Cricket has over the years gained much popularity in Asia, thus the number of cricket players has also grown in tandem. However, cricket players are not as fortunate as other athletes as they do not always have a standard cricket infrastructure to practice; therefore, the injury prevalence is expected to be high. Unfortunately, very few studies have been conducted to investigate the nature and pattern of cricket injuries prevalent to cricketers in this region. Therefore, a prospective cohort injury surveillance study was conducted during the Asian Cricket Council (ACC) Under-19 Elite Cup held in June 2013 in order to gather more data on the type of injuries sustained by cricket players. Overall, 31 injuries occurred to 28 players throughout the tournament, of which 7 injuries happened during practice sessions. The overall injury incidence rate (IIR) was 292.0 per 10,000 player hours (95% CI 176.9-407.1) and 10.4 per 10,000 balls faced and 2.6 per 1000 overs bowled delivered during batting and bowling, respectively. Injuries to the lower limb (IIR: 146; 95% CI 1.8-98.2) were the most frequent, followed by injuries to the upper limb (97.3;95% CI 30.2-164.5) and to the trunk and back (IIR: 36.5;95% CI 0.0-77.7). Sprain/strains (IIR 109.5;95% CI 38.4-180.7) to muscle/tendon and joint/ligament were the most commonly reported nature of injury. This is the first study investigating injury incidence among the players of the ACC. It provides an overview of injuries sustained by elite players' under-19 years of age from 10 Asian countries. The overall IIR is similar to earlier studies conducted in well-established cricket playing nations.
  18. Arifin N, Abu Osman NA, Ali S, Wan Abas WA
    Biomed Eng Online, 2014;13(1):23.
    PMID: 24597518 DOI: 10.1186/1475-925X-13-23
    Achieving independent upright posture has known to be one of the main goals in rehabilitation following lower limb amputation. The purpose of this study was to compare postural steadiness of below knee amputees with visual alterations while wearing three different prosthetic feet.
  19. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Razak NA
    Clin Biomech (Bristol, Avon), 2014 Jan;29(1):87-97.
    PMID: 24315710 DOI: 10.1016/j.clinbiomech.2013.10.013
    Today a number of prosthetic suspension systems are available for transtibial amputees. Consideration of an appropriate suspension system can ensure that amputee's functional needs are satisfied. The higher the insight to suspension systems, the easier would be the selection for prosthetists. This review attempted to find scientific evidence pertaining to various transtibial suspension systems to provide selection criteria for clinicians.
  20. Eshraghi A, Osman NA, Gholizadeh H, Ali S, Shadgan B
    Biomed Eng Online, 2013;12:119.
    PMID: 24237942 DOI: 10.1186/1475-925X-12-119
    Research has tremendously contributed to the developments in both practical and fundamental aspects of limb prosthetics. These advancements are reflected in scientific articles, particularly in the most cited papers. This article aimed to identify the 100 top-cited articles in the field of limb prosthetics and to investigate their main characteristics. Articles related to the field of limb prosthetics and published in the Web of Knowledge database of the Institute for Scientific Information (ISI) from the period of 1980 to 2012. The 100 most cited articles in limb prosthetics were selected based on the citation index report. All types of articles except for proceedings and letters were included in the study. The study design and level of evidence were determined using Sackett's initial rules of evidence. The level of evidence was categorized either as a systematic review or meta-analysis, randomized controlled trial, cohort study, case-control study, case series, expert opinion, or design and development. The top cited articles in prosthetics were published from 1980 to 2012 with a citation range of 11 to 90 times since publication. The mean citation rate was 24.43 (SD 16.7) times. Eighty-four percent of the articles were original publications and were most commonly prospective (76%) and case series studies (67%) that used human subjects (96%) providing level 4 evidence. Among the various fields, rehabilitation (47%), orthopedics (29%), and sport sciences (28%) were the most common fields of study. The study established that studies conducted in North America and were written in English had the highest citations. Top cited articles primarily dealt with lower limb prosthetics, specifically, on transtibial and transradial prosthetic limbs. Majority of the articles were experimental studies.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links