METHODS: A total of doctors (39) and nurses (37) were recruited for an interventional study on the interprofessional learning approach on hospital acquired infection control. The participants responded to the University of West England Interprofessional (UWEIP) questionnaire at baseline consisting of four dimensions in IPL aspects; Self-assessment on communication and teamwork skills (CTW), interprofessional learning (IPL), interprofessional interaction (IPI), and interprofessional relationship (IPR). The Cronbach alpha value for the total questionnaire was established at 0.79.
RESULTS: The majority of doctors scored positive in CTW, IPL, IPR, and neutral in IPI. Nurses' also recorded the highest positive scores in CTW, IPL, and IPR, and neutral in IPI. Negative scores were found in CTW and IPI. A significant difference was revealed between doctors and nurses in IPL attitude; p = 0.024 and there was no significant difference in other dimensions (p > .05). Results also found a significant difference between participants' and non-participants of IPL training sessions; p = 0.009.
CONCLUSIONS: This study revealed the infusion of interprofessional learning training among the health professionals displayed better self-assessments, attitudes, and perceptions towards collaborative practices.
METHOD: This cross-sectional study is comprised of 203 participants, all purportedly healthy term new-born infants from the Obstetrics and Gynaecology ward at Hospital Kuala Lumpur over a 6 months period. The examination list includes external eye examination, red reflex test, and fundus imaging using a wide-field digital retinal imaging system (Phoenix Clinical ICON Paediatric Retinal Camera) by a trained Investigator. The pathologies detected were documented. The results were compared and correlated with similar studies published in the literature previously.
RESULTS: Total ocular abnormalities were detected in 34% of the infants. The most common finding was retinal haemorrhage in 29.6% of the infants, of which 53.3% occurred bilaterally. Spontaneous vaginal delivery (SVD) remained the greatest risk factor which has nearly 3.5 times higher risk of new-borns developing retinal haemorrhage compared to Lower Segment Caesarean Section (LSCS). There was a 6% increased likelihood of developing retinal haemorrhage for every 1-min increment in the duration of 2nd stage of labour.
CONCLUSION: Universal eye screening for all new-borns using a wide-field digital imaging system is realistically possible, safe, and useful in detecting posterior segment disorders. The most common abnormality detected is retinal haemorrhage.
OBSERVATIONS: A total of four cases were reported. Three patients received the Pfizer-BioNTech vaccine, while the other received the Oxford AstraZeneca type. Ocular symptoms occurred after the first vaccine dose in two patients and after the second vaccine dose in the other two. Three out of four patients required active treatment for their vision complications postvaccination. The first patient had acute-onset retinal pigment epitheliitis within 3 h of vaccination and was treated conservatively. The second patient developed unilateral choroidal neovascularization 3 days after vaccination and required intravitreal antivascular endothelial growth factor injection. The third patient presented with bilateral acute multifocal placoid pigment epitheliopathy a week after vaccination and responded to intravenous methylprednisolone. The fourth patient presented with herpes zoster infection and unilateral anterior nongranulomatous uveitis 2 weeks after vaccination and was treated with oral acyclovir and topical corticosteroids. All patients reported some amount of visual recovery.
CONCLUSIONS AND IMPORTANCE: Visual symptoms and various ocular adverse events can occur following COVID-19 vaccination, which warrants further investigation and urgent intervention if necessary. We would suggest patients receiving the COVID-19 vaccination be aware of possible ocular complications and report any symptoms, regardless of severity.
METHODS: The interventional study was conducted in a teaching hospital in Malaysia. Purposive sampling was used to recruit participants from surgical, intensive care, and other units. Thirty-six health professionals in the experimental and forty in the control group completed the study. All subjects participated in an interactive lecture and demonstrated four IPSS on HAIC i.e. (i) taking blood specimen (ii) bedsore dressing (iii) collecting sputum for acid-fast bacilli and (iv) intermittent bladder catheterization. Each team consisted of a doctor and a nurse. A self-administered questionnaire on KAP on HAIC was completed by respondents during the pre-, immediately and, post-intervention. An independent t-test was conducted to measure the significance between the experimental and control group.
RESULTS: The mean scores for KAP among the experimental group increased following the intervention. Significant differences in scores were seen between the two groups post-intervention (p
METHODS: The Menopause Quick 6 (MQ6) questionnaire was translated into the Malay language with an addition of an item, henceforth termed MQ6 (M). Forward and backward translation was performed. Face and content validity were conducted. MQ6 (M) was self-administered to 400 women aged between 40 and 60 attending six primary healthcare clinics in Malaysia. To ascertain the reliability for MQ6 (M), corrected Item-Total Correlation, Squared Multiple Correlation, Cronbach's Alpha if the Item is Deleted, and Kuder-Richardson Reliability Coefficients (KR20). Exploratory factor analysis was done to determine its' construct validity.
RESULTS: The outcome of the validation was satisfactory. By the Lawshe method, the content validity ratios ranged from 0.6 to 1.0 and the content validity index was 0.914. The Internal consistency for MQ6(M) Cronbach's alpha was 0.711 while Kuder-Richardson Reliability Coefficients KR20 was 0.676. Factor loading of all four items is above 0.70, indicating a well-defined structure. Whereas factor loading for three items fell within the range of 0.50-0.69 indicating a practically significant threshold for a new questionnaire.
CONCLUSION: MQ6 (M) has acceptable reliability and construct validity to be considered as a self-administered screening tool in primary care clinics in Malaysia.