Displaying publications 1 - 20 of 104 in total

Abstract:
Sort:
  1. Jahanshahi P, Zalnezhad E, Sekaran SD, Adikan FR
    Sci Rep, 2014 Jan 24;4:3851.
    PMID: 24458089 DOI: 10.1038/srep03851
    Surface plasmon resonance (SPR) is a medical diagnosis technique with high sensitivity and specificity. In this research, a new method based on SPR is proposed for rapid, 10-minute detection of the anti-dengue virus in human serum samples. This novel technique, known as rapid immunoglobulin M (IgM)-based dengue diagnostic test, can be utilized quickly and easily at the point of care. Four dengue virus serotypes were used as ligands on a biochip. According to the results, a serum volume of only 1 μl from a dengue patient (as a minimized volume) is required to indicate SPR angle variation to determine the ratio of each dengue serotype in samples with 83-93% sensitivity and 100% specificity.
  2. Jahanshahi P, Sekaran SD, Adikan FR
    Med Biol Eng Comput, 2015 Aug;53(8):679-87.
    PMID: 25791696 DOI: 10.1007/s11517-015-1262-2
    Evaluation of binding between analytes and its relevant ligands on surface plasmon resonance (SPR) biosensor is of considerable importance for accurate determination and screening of an interference in immunosensors. Dengue virus serotype 2 was used as a case study in this investigation. This research work compares and interprets the results obtained from analytical analysis with the experimental ones. Both the theoretical calculations and experimental results are verified with one sample from each category of dengue serotypes 2 (low, mid, and high positive), which have been examined in the database of established laboratorial diagnosis. In order to perform this investigation, the SPR angle variations are calculated, analyzed, and then validated via experimental SPR angle variations. Accordingly, the error ratios of 5.35, 6.54, and 3.72% were obtained for the low-, mid-, and high-positive-specific immune globulins of patient serums, respectively. In addition, the magnetic fields of the biosensor are numerically simulated to show the effect of different binding mediums.
  3. Sekaran SD, Artsob H
    Expert Opin Med Diagn, 2007 Dec;1(4):521-30.
    PMID: 23496358 DOI: 10.1517/17530059.1.4.521
    Flaviviruses constitute a genus of viruses that are important etiologic agents of human disease, causing clinical disease ranging from fever to severe manifestations, such as encephalitis and hemorrhagic fever. Serology is presently the most frequently used means of diagnosing flavivirus infections. However, other diagnostic tests may be employed, such as molecular detection, virus isolation and antigen-capture procedures. The applicability of the latter three diagnostic procedures can be expected to vary depending upon the infecting flavivirus, as some flaviviruses, such as dengue, display high and long-term viremias, whereas other flaviviruses produce no, or barely detectable, viremias. Molecular diagnostic techniques have been successfully applied to the diagnosis of flavivirus infections and have the advantage of rapidity, sensitivity and specific identification of the infecting virus. However, it is important to ensure that the right detection tools are employed (for example, appropriate primers and probes to detect the specific virus) and that the laboratory maintains a high proficiency in their testing procedures. Some of the studies that have been employed in the diagnosis of flavivirus infections are reviewed in this article. It seems that there is the potential to develop testing algorithms that successfully employ molecular diagnostics alone or in conjunction with other laboratory techniques for the diagnosis of acute human flavivirus infections.
  4. Ambrose JH, Sekaran SD, Azizan A
    J Trop Med, 2017;2017:8072491.
    PMID: 28740517 DOI: 10.1155/2017/8072491
    BACKGROUND: The proper management of patients infected with dengue virus requires early detection. Here, real-time molecular assays have proven useful but have limitations, whereas ELISAs that detect antibodies are still favored but results are obtained too late to be of clinical value. The production of DENV NS1 peaks early during infection and its detection can combine the advantages of both diagnostic approaches.

    METHODS: This study compared assays currently used for detecting DENV infection at the Florida Department of Health including anti-DENV IgM and IgG ELISAs as well as qRT-PCR, against a commercially available DENV NS1 ELISA. These comparisons were made among a group of 21 human sera.

    RESULTS: Nine of 14 (64.3%) DENV qRT-PCR+ samples were also DENV NS1+. Interestingly, the 5 NS1- samples that were qRT-PCR+ were additionally IgM- and IgG+ suggesting a nonprimary infection. Compared to qRT-PCR, the NS1 assay had a sensitivity of 64.3%, specificity 100%, PPV of 100%, and NPV of 58.3%.

    CONCLUSIONS: The NS1 ELISA performed as expected in known DENV qRT-PCR+ samples; however negative NS1 results for qRT-PCR+ and IgG+ sera seemingly reduced the usefulness of the NS1 ELISA for nonprimary cases. We therefore conclude that diagnosis obtained via DENV NS1 ELISA deserves further investigation.

  5. Guad RM, Wu YS, Aung YN, Sekaran SD, Wilke ABB, Low WY, et al.
    PMID: 33922427 DOI: 10.3390/ijerph18094474
    This review provided a systematic overview of the questionnaire-related dengue studies conducted in Malaysia and evaluated their reliability and validity used in the questionnaires. An extensive literature search was conducted using various electronic databases, including PubMed, EMBASE, Medline, and ScienceDirect. Systematic reviews and meta-analysis (PRISMA) were selected as the preferred item reporting method. Out of 88 identified dengue-related, 57 published from 2000 to April 2020 met the inclusion criteria and were included. Based on the meta-analysis, a poor mean score was obtained for knowledge (49%), attitude (44%), and preventive practice (55%). The study showed that the level of knowledge on cardinal signs and modes of transmission for dengue virus were highest among health care workers, followed by students (international and local) and lastly community residents. In treatment-seeking behaviours, only half of the respondents (50.8%) would send their child to the nearest health clinics or hospitals when a child became restless or lethargic. The acceptance rate for dengue vaccine, bacteria (Wolbachia), as a vector for dengue control and self-test diagnostic kit for dengue showed considerably high (88.4%, 70%, and 44.8%, respectively). Health belief model (HBM) constructs, such as perceived barriers, perceived severity, perceived susceptibility, self-efficacy, and perceived benefit influence prevention practices. Lastly, only 23 articles (40.3%) had piloted or pretested the questionnaire before surveying, in which three reported Cronbach's alpha coefficient (0.70-0.90). A need for active participation of communities and healthcare personnel, promotion of awareness, and safe complementary medicines, as well as assessment of psychometric properties of questionnaire use in dengue surveys in Malaysia, in order for assessing dengue reliably and valid.
  6. Guad RM, Mangantig E, Low WY, Taylor-Robinson AW, Azzani M, Sekaran SD, et al.
    BMC Infect Dis, 2021 Aug 31;21(1):893.
    PMID: 34465288 DOI: 10.1186/s12879-021-06606-6
    BACKGROUND: Several studies have reported a significant association of knowledge, attitude and preventive practice (KAP) regarding dengue infection among community's resident in endemic areas. In this study we aimed to assess and develop a reliable and valid KAP survey on the subject of dengue that is suitable for the resident population of Sabah, Malaysia.

    METHODS: A community-based cross-sectional study was conducted from October 2019 to February 2020 involving 468 respondents. Information on the socio-demographic characteristics of the participants (six items), their KAP (44, 15 and 18 items on knowledge, attitude and practice, respectively) and treatment-seeking behaviour (five items) towards dengue was collected using a structured questionnaire. Data analysis was performed using SPSS and R software in the R Studio environment. The knowledge section was analysed by two-parameter logistic item response theory (2-PL IRT) using ltm package. The construct validity and reliability of items for sections on attitude, practice and treatment-seeking behaviour were analysed using psy package.

    RESULTS: For the knowledge section, only 70.5% (31/44) of items were within or close to the parameter acceptable range of -3 to + 3 of difficulty. In terms of discrimination, 65.9% (29/44) of items were within or close to the acceptable range of 0.35 to 2.5, and 24 items (54.5%) failed to fit the 2-PL IRT model (P  0.7, while based on the communalities, 11 items in the attitude section were excluded due to very low h2, factor loading values and low correlation with the total ( 0.7. The communalities of the practice section showed that seven items had low h2 values (

  7. Guad RM, Carandang RR, Solidum JN, W Taylor-Robinson A, Wu YS, Aung YN, et al.
    PLoS One, 2021;16(12):e0261412.
    PMID: 34929011 DOI: 10.1371/journal.pone.0261412
    BACKGROUND: Dengue is the most rapidly spreading mosquito-borne viral disease of humans worldwide, including southeast Asia region. This review provides a comprehensive overview of questionnaire-related dengue studies conducted in the Philippines and evaluates their reliability and validity in these surveys.

    METHODS: A review protocol constructed by a panel of experienced academic reviewers was used to formulate the methodology, research design, search strategy and selection criteria. An extensive literature search was conducted between March-June 2020 in various major electronic biomedical databases including PubMed, EMBASE, MEDLINE and ScienceDirect. A systematic review and meta-analysis (PRISMA) were selected as the preferred item reporting method.

    RESULTS: Out of a total of 34 peer-reviewed dengue-related KAP studies that were identified, 15 published from 2000 to April 2020 met the inclusion criteria. Based on the meta-analysis, a poor mean score was obtained for each of knowledge (68.89), attitude (49.86) and preventive practice (64.69). Most respondents were equipped with a good knowledge of the major clinical signs of dengue. Worryingly, 95% of respondents showed several negative attitudes towards dengue prevention, claiming that this was not possible and that enacting preventive practices was not their responsibility. Interestingly, television or radio was claimed as the main source of gaining dengue information (range 50-95%). Lastly, only five articles (33.3%) piloted or pretested their questionnaire before surveying, of which three reported Cronbach's alpha coefficient (range 0.70 to 0.90).

    CONCLUSION: This review indicates that to combat the growing public health threat of dengue to the Philippines, we need the active participation of resident communities, full engagement of healthcare personnel, promotion of awareness campaigns, and access to safe complementary and alternative medicines. Importantly, the psychometric properties of each questionnaire should be assessed rigorously.

  8. Wong WR, Sekaran SD, Adikan FR, Berini P
    Biosens Bioelectron, 2016 Apr 15;78:132-9.
    PMID: 26599483 DOI: 10.1016/j.bios.2015.11.030
    The non-structural 1 (NS1) protein of the dengue virus circulates in infected patients' blood samples and can be used for early diagnosis of dengue infection. In this paper, we present the detection of naturally-occurring dengue NS1 antigen in infected patient blood plasma using straight long-range surface plasmon waveguides. Three commercially-available anti-NS1 monoclonal antibodies were used for recognition and their performance was compared and discussed. A similar figure of merit to the one used in conventional dengue NS1 capture using an enzyme-linked immunosorbent assay (ELISA) was applied to our results. In general, the positive patient samples can be clearly differentiated from the negative ones and the results agree with those obtained using ELISA. The largest signal-to-noise ratio observed during the experiments was 356 and the best detection limit observed is estimated as 5.73 pg/mm(2).
  9. Wong WR, Krupin O, Sekaran SD, Mahamd Adikan FR, Berini P
    Anal Chem, 2014 Feb 4;86(3):1735-43.
    PMID: 24410440 DOI: 10.1021/ac403539k
    We present a compact, cost-effective, label-free, real-time biosensor based on long-range surface plasmon polariton (LRSPP) gold (Au) waveguides for the detection of dengue-specific immunoglobulin M (IgM) antibody, and we demonstrate detection in actual patient blood plasma samples. Two surface functionalization approaches are proposed and demonstrated: a dengue virus serotype 2 (DENV-2) functionalized surface to capture dengue-specific IgM antibody in blood plasma and the reverse, a blood plasma functionalized surface to capture DENV-2. The results obtained via these two surface functionalization approaches are comparable to, or of greater quality, than those collected by conventional IgM antibody capture enzyme linked immunosorbent assay (MAC-ELISA). Our second functionalization approach was found to minimize nonspecific binding, thus improving the sensitivity and accuracy of the test. We also demonstrate reuse of the biosensors by regenerating the sensing surface down to the virus (or antibody) level or down to the bare Au.
  10. Le CF, Jefferies JM, Yusof MY, Sekaran SD, Clarke SC
    Expert Rev Anti Infect Ther, 2012 Jun;10(6):707-19.
    PMID: 22734960 DOI: 10.1586/eri.12.54
    In Malaysia, various aspects of the epidemiology of pneumococcal carriage and disease remain largely unclear due to the lack of supporting data. Although a number of relevant studies have been documented, their individual discrete findings are not sufficient to inform experts on pneumococcal epidemiology at a national level. Therefore, in this review we aim to bring together and systematically evaluate the key information regarding pneumococcal disease epidemiology in Malaysia and provide a comprehensive overview of the data. Major aspects discussed include pneumococcal carriage, disease incidence and prevalence, age factors, invasiveness of pneumococci, serotypes, molecular epidemiology and antibiotic susceptibility. Penicillin resistance is increasingly prevalent and studies suggest that the majority of pneumococcal serotypes causing pneumococcal disease in Malaysia are covered by currently available conjugate vaccines. Continued surveillance is needed to provide a better understanding of pneumococcal epidemiology in Malaysia.
  11. Fry SR, Meyer M, Semple MG, Simmons CP, Sekaran SD, Huang JX, et al.
    PLoS Negl Trop Dis, 2011 Jun;5(6):e1199.
    PMID: 21713023 DOI: 10.1371/journal.pntd.0001199
    BACKGROUND: Serological tests for IgM and IgG are routinely used in clinical laboratories for the rapid diagnosis of dengue and can differentiate between primary and secondary infections. Dengue virus non-structural protein 1 (NS1) has been identified as an early marker for acute dengue, and is typically present between days 1-9 post-onset of illness but following seroconversion it can be difficult to detect in serum.
    AIMS: To evaluate the performance of a newly developed Panbio® Dengue Early Rapid test for NS1 and determine if it can improve diagnostic sensitivity when used in combination with a commercial IgM/IgG rapid test.
    METHODOLOGY: The clinical performance of the Dengue Early Rapid was evaluated in a retrospective study in Vietnam with 198 acute laboratory-confirmed positive and 100 negative samples. The performance of the Dengue Early Rapid in combination with the IgM/IgG Rapid test was also evaluated in Malaysia with 263 laboratory-confirmed positive and 30 negative samples.
    KEY RESULTS: In Vietnam the sensitivity and specificity of the test was 69.2% (95% CI: 62.8% to 75.6%) and 96% (95% CI: 92.2% to 99.8) respectively. In Malaysia the performance was similar with 68.9% sensitivity (95% CI: 61.8% to 76.1%) and 96.7% specificity (95% CI: 82.8% to 99.9%) compared to RT-PCR. Importantly, when the Dengue Early Rapid test was used in combination with the IgM/IgG test the sensitivity increased to 93.0%. When the two tests were compared at each day post-onset of illness there was clear differentiation between the antigen and antibody markers.
    CONCLUSIONS: This study highlights that using dengue NS1 antigen detection in combination with anti-glycoprotein E IgM and IgG serology can significantly increase the sensitivity of acute dengue diagnosis and extends the possible window of detection to include very early acute samples and enhances the clinical utility of rapid immunochromatographic testing for dengue.
  12. Farooq SM, Boppana NB, Devarajan A, Asokan D, Sekaran SD, Shankar EM, et al.
    PLoS One, 2014;9(4):e93056.
    PMID: 24691130 DOI: 10.1371/journal.pone.0093056
    Oxalate toxicity is mediated through generation of reactive oxygen species (ROS) via a process that is partly dependent on mitochondrial dysfunction. Here, we investigated whether C-phycocyanin (CP) could protect against oxidative stress-mediated intracellular damage triggered by oxalate in MDCK cells. DCFDA, a fluorescence-based probe and hexanoyl-lysine adduct (HEL), an oxidative stress marker were used to investigate the effect of CP on oxalate-induced ROS production and membrane lipid peroxidation (LPO). The role of CP against oxalate-induced oxidative stress was studied by the evaluation of mitochondrial membrane potential by JC1 fluorescein staining, quantification of ATP synthesis and stress-induced MAP kinases (JNK/SAPK and ERK1/2). Our results revealed that oxalate-induced cells show markedly increased ROS levels and HEL protein expression that were significantly decreased following pre-treatment with CP. Further, JC1 staining showed that CP pre-treatment conferred significant protection from mitochondrial membrane permeability and increased ATP production in CP-treated cells than oxalate-alone-treated cells. In addition, CP treated cells significantly decreased the expression of phosphorylated JNK/SAPK and ERK1/2 as compared to oxalate-alone-treated cells. We concluded that CP could be used as a potential free radical-scavenging therapeutic strategy against oxidative stress-associated diseases including urolithiasis.
  13. Sumpio BJ, Chitragari G, Moriguchi T, Shalaby S, Pappas-Brown V, Khan AM, et al.
    Int. J. Angiol., 2015 Mar;24(1):41-6.
    PMID: 27053915 DOI: 10.1055/s-0034-1370890
    African trypanosomes are tsetse fly transmitted protozoan parasites responsible for human African trypanosomiasis, a disease characterized by a plethora of neurological symptoms and death. How the parasites under microvascular shear stress (SS) flow conditions in the brain cross the blood-brain barrier (BBB) is not known. In vitro studies using static models comprised of human brain microvascular endothelial cells (BMEC) show that BBB activation and crossing by trypanosomes requires the orchestration of parasite cysteine proteases and host calcium-mediated cell signaling. Here, we examine BMEC barrier function and the activation of extracellular signal-regulated kinase (ERK)1/2 and ERK5, mitogen-activated protein kinase family regulators of microvascular permeability, under static and laminar SS flow and in the context of trypanosome infection. Confluent human BMEC were cultured in electric cell-substrate impedance sensing (ECIS) and parallel-plate glass slide chambers. The human BMEC were exposed to 2 or 14 dyn/cm(2) SS in the presence or absence of trypanosomes. Real-time changes in transendothelial electrical resistance (TEER) were monitored and phosphorylation of ERK1/2 and ERK5 analyzed by immunoblot assay. After reaching confluence under static conditions human BMEC TEER was found to rapidly increase when exposed to 2 dyn/cm(2) SS, a condition that mimics SS in brain postcapillary venules. Addition of African trypanosomes caused a rapid drop in human BMEC TEER. Increasing SS to 14 dyn/cm(2), a condition mimicking SS in brain capillaries, led to a transient increase in TEER in both control and infected human BMEC. However, no differences in ERK1/2 and ERK5 activation were found under any condition tested. African trypanosomiasis alters BBB permeability under low shear conditions through an ERK1/2 and ERK5 independent pathway.
  14. Jusof FF, Lim CK, Aziz FN, Soe HJ, Raju CS, Sekaran SD, et al.
    J Infect Dis, 2022 Nov 28;226(11):1964-1973.
    PMID: 35767283 DOI: 10.1093/infdis/jiac273
    BACKGROUND: The resolution or aggravation of dengue infection depends on the patient's immune response during the critical phase. Cytokines released by immune cells increase with the worsening severity of dengue infections. Cytokines activate the kynurenine pathway (KP) and the extent of KP activation then influences disease severity.

    METHODS: KP metabolites and cytokines in plasma samples of patients with dengue infection (dengue without warning signs [DWS-], dengue with warning signs [DWS+], or severe dengue) were analyzed. Cytokines (interferon gamma [IFN-ɣ], tumor necrosis factor, interleukin 6, CXCL10/interferon-inducile protein 10 [IP-10], interleukin 18 [IL-18], CCL2/monocyte chemoattractant protein-1 [MCP-1], and CCL4/macrophage inflammatory protein-1beta [MIP-1β] were assessed by a Human Luminex Screening Assay, while KP metabolites (tryptophan, kynurenine, anthranilic acid [AA], picolinic acid, and quinolinic acid) were assessed by ultra-high-performance liquid chromatography and Gas Chromatography Mass Spectrophotometry [GCMS] assays.

    RESULTS: Patients with DWS+ had increased activation of the KP where kynurenine-tryptophan ratio, anthranilic acid, and picolinic acid were elevated. These patients also had higher levels of the cytokines IFN-ɣ, CXCL10, CCL4, and IL-18 than those with DWS-. Further receiver operating characteristic analysis identified 3 prognostic biomarker candidates, CXCL10, CCL2, and AA, which predicted patients with higher risks of developing DWS+ with an accuracy of 97%.

    CONCLUSIONS: The data suggest a unique biochemical signature in patients with DWS+. CXCL10 and CCL2 together with AA are potential prognostic biomarkers that discern patients with higher risk of developing DWS+ at earlier stages of infection.

  15. Pourshahrestani S, Zeimaran E, Kadri NA, Gargiulo N, Jindal HM, Hasikin K, et al.
    Mater Sci Eng C Mater Biol Appl, 2019 May;98:1022-1033.
    PMID: 30812986 DOI: 10.1016/j.msec.2019.01.022
    A novel series of silver-doped mesoporous bioactive glass/poly(1,8-octanediol citrate) (AgMBG/POC) elastomeric biocomposite scaffolds were successfully constructed by a salt-leaching technique for the first time and the effect of inclusion of different AgMBG contents (5, 10, and 20 wt%) on physicochemical and biological properties of pure POC elastomer was evaluated. Results indicated that AgMBG particles were uniformly dispersed in the POC matrix and increasing the AgMBG concentration into POC matrix up to 20 wt% enhanced thermal behaviour, mechanical properties and water uptake ability of the composite scaffolds compared to those from POC. The 20%AgMBG/POC additionally showed higher degradation rate in Tris(hydroxymethyl)-aminomethane-HCl (Tris-HCl) compared with pure POC and lost about 26% of its initial weight after soaking for 28 days. The AgMBG phase incorporation also significantly endowed the resulting composite scaffolds with efficient antibacterial properties against Escherichia coli and Staphylococcus aureus bacteria while preserving their favorable biocompatibility with soft tissue cells (i.e., human dermal fibroblast cells). Taken together, our results suggest that the synergistic effect of both AgMBG and POC make these newly designed AgMBG/POC composite scaffold an attractive candidate for soft tissue engineering applications.
  16. Lum LC, Syed Omar SF, Sri La Sri Ponnampalavanar S, Tan LH, Sekaran SD, Kamarulzaman A
    PLoS Negl Trop Dis, 2015 Jun;9(6):e0003836.
    PMID: 26047325 DOI: 10.1371/journal.pntd.0003836
    INTRODUCTION: The increasing incidence of dengue among adults in Malaysia and other countries has important implications for health services. Before 2004, in order to cope with the surge in adult dengue admissions, each of the six medical wards in a university hospital took turns daily to admit and manage patients with dengue. Despite regular in-house training, the implementation of the WHO 1997 dengue case management guidelines by the multiple medical teams was piecemeal and resulted in high variability of care. A restructuring of adult dengue inpatient service in 2004 resulted in all patients being admitted to one ward under the care of the infectious disease unit. Hospital and Intensive Care Unit admission criteria, discharge criteria and clinical laboratory testing were maintained unchanged throughout the study period.

    OBJECTIVES: To evaluate the impact of cohorting adult dengue patients on the quality of care and the clinical outcome in a university hospital in Malaysia.

    METHODS: A pre (2003) and post-intervention (2005-6) retrospective study was undertaken.

    INTERVENTION: Cohorting all dengue patients under the care of the Infectious Disease team in a designated ward in 2004.

    RESULTS: The number of patients enrolled was 352 in 2003, 785 in 2005 and 1158 in 2006. The evaluation and detection of haemorrhage remained high (>90%) and unchanged throughout the study period. The evaluation of plasma leakage increased from 35.4% pre-intervention to 78.8% post-intervention (p = <0.001) while its detection increased from 11.4% to 41.6% (p = <0.001). Examination for peripheral perfusion was undertaken in only 13.1% of patients pre-intervention, with a significant increase post-intervention, 18.6% and 34.2% respectively, p = <0.001. Pre-intervention, more patients had hypotension (21.5%) than detected peripheral hypoperfusion (11.4%), indicating that clinicians recognised shock only when patients developed hypotension. In contrast, post-intervention, clinicians recognised peripheral hypoperfusion as an early sign of shock. The highest haematocrit was significantly higher post-intervention but the lowest total white cell counts and platelet counts remained unchanged. A significant and progressive reduction in the use of platelet transfusions occurred, from 21.7% pre-intervention to 14.6% in 2005 and 5.2% in 2006 post-intervention, p<0.001. Likewise, the use of plasma transfusion decreased significantly from 6.1% pre-intervention to 4.0% and 1.6% in the post-intervention years of 2005 and 2006 respectively, p<0.001. The duration of intravenous fluid therapy decreased from 3 days pre-intervention to 2.5 days (p<0.001) post-intervention; the length of hospital stay reduced from 4 days pre- to 3 days (p<0.001) post-intervention and the rate of intensive care admission from 5.8% pre to 2.6% and 2.5% post-intervention, p = 0.005.

    CONCLUSION: Cohorting adult dengue patients under a dedicated and trained team of doctors and nurses led to a substantial improvement in quality of care and clinical outcome.

  17. Darwish NT, Sekaran SD, Alias Y, Khor SM
    J Pharm Biomed Anal, 2018 Feb 05;149:591-602.
    PMID: 29197806 DOI: 10.1016/j.jpba.2017.11.064
    The sharp increase in incidence of dengue infection has necessitated the development of methods for the rapid diagnosis of this deadly disease. Here we report the design and development of a reliable, sensitive, and specific optical immunosensor for the detection of the dengue nonstructural protein 1 (NS1) biomarker in clinical samples obtained during early stages of infection. The present optical NS1 immunosensor comprises a biosensing surface consisting of specific monoclonal NS1 antibody for immunofluorescence-based NS1 antigen determination using fluorescein isothiocyanate (FITC) conjugated to IgG antibody. The linear range of the optical immunosensor was from 15-500ngmL-1, with coefficient of determination (R2) of 0.92, high reproducibility (the relative standard deviation obtained was 2%), good stability for 21days at 4°C, and low detection limit (LOD) at 15ngmL-1. Furthermore, the optical immunosensor was capable of detecting NS1 analytes in plasma specimens from patients infected with the dengue virus, with low cross-reaction with plasma specimens containing the Japanese encephalitis virus (JEV) and Zika virus. No studies have been performed on the reproducibility and cross-reactivity regarding NS1 specificity, which is thus a limitation for optical NS1 immunosensors. In contrast, the present study addressed these limitations carefully where these two important experiments were conducted to showcase the robustness of our newly developed optical-based fluorescence immunosensor, which can be practically used for direct NS1 determination in any untreated clinical sample.
  18. Looi KW, Matsui Y, Kono M, Samudi C, Kojima N, Ong JX, et al.
    Int J Infect Dis, 2021 Sep;110:187-194.
    PMID: 34302960 DOI: 10.1016/j.ijid.2021.07.048
    OBJECTIVES: Progression of dengue is often associated with thrombocytopenia resulting from viral-induced bone marrow suppression and immune-mediated peripheral platelet consumption. Immature platelet fraction (IPF), which can be measured using a haematology analyser, is a precursor indicating platelet formation in the bone marrow. This study evaluated the trend of IPF as an early recovery indicator of platelets in dengue patients with thrombocytopenia, and its relationship with severe dengue in conjunction with reticulocyte count.

    METHODS: Hospitalized patients with dengue were enrolled and followed-up daily until discharge. Blood investigations included daily full blood counts and IPF measured using a haematology analyser.

    RESULTS: In total, 287 patients with confirmed dengue were enrolled in this study, 25 of whom had severe dengue. All patients had a decreasing trend in platelet count in the first week of illness, concomitant with an increasing trend in the percentage of immature platelets to total platelets (IPF%) for more than 3 days prior to platelet recovery. IPF% was significantly increased in patients with severe dengue compared with patients with non-severe dengue on days 3-5 after the onset of fever. Reticulocyte count increased significantly in patients with severe dengue on day 5.

    CONCLUSIONS: IPF can be utilized as an early recovery indicator of platelets in patients with dengue and thrombocytopenia.

  19. Jahanshahi P, Wei Q, Jie Z, Ghomeishi M, Sekaran SD, Mahamd Adikan FR
    Bioengineered, 2017 May 04;8(3):239-247.
    PMID: 27533620 DOI: 10.1080/21655979.2016.1223413
    Surface plasmon resonance (SPR) sensing is recently emerging as a valuable technique for measuring the binding constants, association and dissociation rate constants, and stoichimetry for a binding interaction kinetics in a number of emerging biological areas. This technique can be applied to the study of immune system diseases in order to contribute to improved understanding and evaluation of binding parameters for a variety of interactions between antigens and antibodies biochemically and clinically. Since the binding constants determination of an anti-protein dengue antibody (Ab) to a protein dengue antigen (Ag) is mostly complicated, the SPR technique aids a determination of binding parameters directly for a variety of particular dengue Ag_Ab interactions in the real-time. The study highlights the doctrine of real-time dengue Ag_Ab interaction kinetics as well as to determine the binding parameters that is performed with SPR technique. In addition, this article presents a precise prediction as a reference curve for determination of dengue sample concentration.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links