OBJECTIVES: To determine the effect of continuous distending pressure (CDP) on the need for IPPV and associated morbidity in spontaneously breathing preterm infants with respiratory distress.Subgroup analyses were planned on the basis of birth weight (> or < 1000 or 1500 g), gestational age (groups divided at about 28 weeks and 32 weeks), methods of application of CDP (i.e. CPAP and CNP), application early versus late in the course of respiratory distress and high versus low pressure CDP and application of CDP in tertiary compared with non-tertiary hospitals, with the need for sensitivity analysis determined by trial quality.At the 2008 update, the objectives were modified to include preterm infants with respiratory failure.
SEARCH METHODS: We used the standard search strategy of the Neonatal Review Group. This included searches of the Oxford Database of Perinatal Trials, the Cochrane Central Register of Controlled Trials (CENTRAL, 2015 Issue 4), MEDLINE (1966 to 30 April 2015) and EMBASE (1980 to 30 April 2015) with no language restriction, as well as controlled-trials.com, clinicaltrials.gov and the International Clinical Trials Registry Platform of the World Health Organization (WHO).
SELECTION CRITERIA: All random or quasi-random trials of preterm infants with respiratory distress were eligible. Interventions were continuous distending pressure including continuous positive airway pressure (CPAP) by mask, nasal prong, nasopharyngeal tube or endotracheal tube, or continuous negative pressure (CNP) via a chamber enclosing the thorax and the lower body, compared with spontaneous breathing with oxygen added as necessary.
DATA COLLECTION AND ANALYSIS: We used standard methods of The Cochrane Collaboration and its Neonatal Review Group, including independent assessment of trial quality and extraction of data by each review author.
MAIN RESULTS: We included six studies involving 355 infants - two using face mask CPAP, two CNP, one nasal CPAP and one both CNP (for less ill babies) and endotracheal CPAP (for sicker babies). For this update, we included no new trials.Continuous distending pressure (CDP) is associated with lower risk of treatment failure (death or use of assisted ventilation) (typical risk ratio (RR) 0.65, 95% confidence interval (CI) 0.52 to 0.81; typical risk difference (RD) -0.20, 95% CI -0.29 to -0.10; number needed to treat for an additional beneficial outcome (NNTB) 5, 95% CI 4 to 10; six studies; 355 infants), lower overall mortality (typical RR 0.52, 95% CI 0.32 to 0.87; typical RD -0.15, 95% CI -0.26 to -0.04; NNTB 7, 95% CI 4 to 25; six studies; 355 infants) and lower mortality in infants with birth weight above 1500 g (typical RR 0.24, 95% CI 0.07 to 0.84; typical RD -0.28, 95% CI -0.48 to -0.08; NNTB 4, 95% CI 2.00 to 13.00; two studies; 60 infants). Use of CDP is associated with increased risk of pneumothorax (typical RR 2.64, 95% CI 1.39 to 5.04; typical RD 0.10, 95% CI 0.04 to 0.17; number needed to treat for an additional harmful outcome (NNTH) 17, 95% CI 17.00 to 25.00; six studies; 355 infants). We found no difference in bronchopulmonary dysplasia (BPD), defined as oxygen dependency at 28 days (three studies, 260 infants), as well as no difference in outcome at nine to 14 years (one study, 37 infants).
AUTHORS' CONCLUSIONS: In preterm infants with respiratory distress, the application of CDP as CPAP or CNP is associated with reduced respiratory failure and mortality and an increased rate of pneumothorax. Four out of six of these trials were done in the 1970s. Therefore, the applicability of these results to current practice is difficult to assess. Further research is required to determine the best mode of administration.
OBJECTIVES: In spontaneously breathing preterm infants with RDS, to determine if continuous distending pressure (CDP) reduces the need for IPPV and associated morbidity without adverse effects.
SEARCH STRATEGY: The standard search strategy of the Neonatal Review group was used. This included searches of the Oxford Database of Perinatal Trials, Cochrane Controlled Trials Register (The Cochrane Library, Issue 1, 2002), MEDLINE (1966-January 2002), and EMBASE (1980-January 2002), previous reviews including cross references, abstracts, conference and symposia proceedings, expert informants, journal hand searching mainly in the English language.
SELECTION CRITERIA: All trials using random or quasi-random allocation of preterm infants with RDS were eligible. Interventions were continuous distending pressure including continuous positive airway pressure (CPAP) by mask, nasal prong, nasopharyngeal tube, or endotracheal tube, or continuous negative pressure (CNP) via a chamber enclosing the thorax and lower body, compared with standard care.
DATA COLLECTION AND ANALYSIS: Standard methods of the Cochrane Collaboration and its Neonatal Review Group were used, including independent assessment of trial quality and extraction of data by each author.
MAIN RESULTS: CDP is associated with a lower rate of failed treatment (death or use of assisted ventilation) [summary RR 0.70 (0.55, 0.88), RD -0.22 (-0.35, -0.09), NNT 5 (3, 11)], overall mortality [summary RR 0.52 (0.32, 0.87), RD -0.15 (-0.26, -0.04), NNT 7 (4, 25)], and mortality in infants with birthweights above 1500 g [summary RR 0.24 (0.07, 0.84), RD -0.281 (-0.483, -0.078), NNT 4 (2, 13)]. The use of CDP is associated with an increased rate of pneumothorax [summary RR 2.36 (1.25, 5.54), RD 0.14 (0.04, 0.23), NNH 7 (4, 24)].
REVIEWER'S CONCLUSIONS: In preterm infants with RDS the application of CDP either as CPAP or CNP is associated with benefits in terms of reduced respiratory failure and reduced mortality. CDP is associated with an increased rate of pneumothorax. The applicability of these results to current practice is difficult to assess, given the intensive care setting of the 1970s when four out of five of these trials were done. Where resources are limited, such as in developing countries, CPAP for RDS may have a clinical role. Further research is required to determine the best mode of administration and its role in modern intensive care settings
OBJECTIVES: In spontaneously breathing preterm infants with RDS, to determine if continuous distending pressure (CDP) reduces the need for IPPV and associated morbidity without adverse effects.
SEARCH STRATEGY: The standard search strategy of the Neonatal Review group was used. This included searches of the Oxford Database of Perinatal Trials, Cochrane Controlled Trials Register, MEDLINE (1966-Jan. 2000), previous reviews including cross references, abstracts, conference and symposia proceedings, expert informants, journal hand searching mainly in the English language.
SELECTION CRITERIA: All trials using random or quasi-random patient allocation of newborn infants with RDS were eligible. Interventions were continuous distending pressure including continuous positive airway pressure (CPAP) by mask, nasal prong, nasopharyngeal tube, or endotracheal tube, or continuous negative pressure (CNP) via a chamber enclosing the thorax and lower body, compared with standard care.
DATA COLLECTION AND ANALYSIS: Standard methods of the Cochrane Collaboration and its Neonatal Review Group, including independent assessment of trial quality and extraction of data by each author, were used.
MAIN RESULTS: CDP is associated with a lower rate of failed treatment (death or use of assisted ventilation), overall mortality, and mortality in infants with birthweights above 1500 g. The use of CDP is associated with an increased rate of pneumothorax.
REVIEWER'S CONCLUSIONS: In preterm infants with RDS the application of CDP either as CPAP or CNP is associated with some benefits in terms of reduced respiratory failure and reduced mortality. CDP is associated with an increased rate of pneumothorax. The applicability of these results to current practice is difficult to assess, given the outdated methods to administer CDP, low use of antenatal corticosteroids, non-availability of surfactant and the intensive care setting of the 1970s when these trials were done. Where resources are limited, such as in developing countries, CPAP for RDS may have a clinical role. Further research is required to determine the best mode of administration and its role in modern intensive care settings
OBJECTIVES: 1. To assess the effects of CPAP on AoP in preterm infants (this may be compared to supportive care or mechanical ventilation). 2. To assess the effects of different CPAP delivery systems on AoP in preterm infants.
SEARCH METHODS: Searches were conducted in September 2022 in the following databases: Cochrane Library, MEDLINE, Embase, and CINAHL. We also searched clinical trial registries and the reference lists of studies selected for inclusion.
SELECTION CRITERIA: We included all randomised and quasi-randomised controlled trials (RCTs) in which researchers determined that CPAP was necessary for AoP in preterm infants (born before 37 weeks). Cross-over studies were also included, provided sufficient data were available for analysis.
DATA COLLECTION AND ANALYSIS: We used the standard methods of Cochrane and Cochrane Neonatal, including independent assessment of risk of bias and extraction of data by at least two review authors. Discrepancies were resolved by involvement of a third author. We used the GRADE approach to assess the certainty of evidence for the following outcomes: 1) failed CPAP; 2) apnoea; 3) adverse effects of CPAP.
MAIN RESULTS: We included four single-centre trials conducted in Malaysia, Spain, Germany, and North America, involving 138 infants with a mean/median gestation of 26 to 28 weeks. Two studies were parallel-group RCTs and two were cross-over trials. None of the studies compared CPAP with supportive care. All trials compared one form of CPAP with another. Two compared a variable flow device with ventilator CPAP, one compared two different variable flow devices, and one compared a variable flow device with bubble CPAP. Interventions were administered for periods ranging between six and 48 hours, with pressures between 4 and 6 cm H2O. We assessed all trials as having a high risk of bias for blinding of participants and personnel, and two studies for blinding of outcome assessors. We found a high risk of a carry-over effect in two studies where the washout period was not adequately described, and a high risk of bias in a study that appeared to use an analysis method not generally accepted for cross-over studies. Comparison 1. CPAP and supportive care compared to supportive care alone We did not identify any study for inclusion in this comparison. Comparison 2. CPAP delivered by different types of devices 2a. Variable flow compared to ventilator CPAP Two studies were included in this comparison. We are very uncertain whether there is any difference in the incidence of failed CPAP, defined as the need for mechanical ventilation (risk ratio (RR) 0.16, 95% confidence interval (CI) 0.01 to 2.90; 1 study, 26 participants; very low-certainty). We are very uncertain whether there is any difference in the frequency of apnoea events (mean difference (MD) per four-hour interval -0.10, 95% CI -1.30 to 1.10; 1 study, 26 participants; very low-certainty). We are uncertain whether there is any difference in adverse events. Neurodevelopmental outcomes were not reported. 2b. Variable flow compared to bubble CPAP We included one study in this comparison, but it did not report our pre-specified outcomes. 2c. Infant Flow variable flow CPAP compared to Medijet variable flow CPAP We are very uncertain whether there is any difference in the incidence of failed CPAP (RR 2.62, 95% CI 0.91 to 7.53; 1 study, 80 participants; very low-certainty). The frequency of apnoea was not reported, and we do not know whether there is any difference in adverse events. Neurodevelopmental outcomes were not reported. Comparison 3. CPAP compared to mechanical ventilation We did not identify any studies for inclusion in this comparison.
AUTHORS' CONCLUSIONS: Due to the limited available evidence, we are very uncertain whether any CPAP device is more effective than other forms of supportive care, other CPAP devices, or mechanical ventilation for the prevention and treatment of AoP. The devices used in these studies included two types of variable flow CPAP device: bubble CPAP and ventilator CPAP. For each comparison, data were only available from a single study. There are theoretical reasons why these devices might have different effects on AoP, therefore further trials are indicated.
OBJECTIVES: To determine the effect of continuous distending pressure in the form of CPAP on the need for IPPV and associated morbidity in spontaneously breathing preterm infants with respiratory distress.
SEARCH METHODS: We used the standard strategy of Cochrane Neonatal to search CENTRAL (2020, Issue 6); Ovid MEDLINE and Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Daily and Versions; and CINAHL on 30 June 2020. We also searched clinical trials databases and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials.
SELECTION CRITERIA: All randomised or quasi-randomised trials of preterm infants with respiratory distress were eligible. Interventions were CPAP by mask, nasal prong, nasopharyngeal tube or endotracheal tube, compared with spontaneous breathing with supplemental oxygen as necessary.
DATA COLLECTION AND ANALYSIS: We used standard methods of Cochrane and its Neonatal Review Group, including independent assessment of risk of bias and extraction of data by two review authors. We used the GRADE approach to assess the certainty of evidence. Subgroup analyses were planned on the basis of birth weight (greater than or less than 1000 g or 1500 g), gestational age (groups divided at about 28 weeks and 32 weeks), timing of application (early versus late in the course of respiratory distress), pressure applied (high versus low) and trial setting (tertiary compared with non-tertiary hospitals; high income compared with low income) MAIN RESULTS: We included five studies involving 322 infants; two studies used face mask CPAP, two studies used nasal CPAP and one study used endotracheal CPAP and continuing negative pressure for a small number of less ill babies. For this update, we included one new trial. CPAP was associated with lower risk of treatment failure (death or use of assisted ventilation) (typical risk ratio (RR) 0.64, 95% confidence interval (CI) 0.50 to 0.82; typical risk difference (RD) -0.19, 95% CI -0.28 to -0.09; number needed to treat for an additional beneficial outcome (NNTB) 6, 95% CI 4 to 11; I2 = 50%; 5 studies, 322 infants; very low-certainty evidence), lower use of ventilatory assistance (typical RR 0.72, 95% CI 0.54 to 0.96; typical RD -0.13, 95% CI -0.25 to -0.02; NNTB 8, 95% CI 4 to 50; I2 = 55%; very low-certainty evidence) and lower overall mortality (typical RR 0.53, 95% CI 0.34 to 0.83; typical RD -0.11, 95% CI -0.18 to -0.04; NNTB 9, 95% CI 2 to 13; I2 = 0%; 5 studies, 322 infants; moderate-certainty evidence). CPAP was associated with increased risk of pneumothorax (typical RR 2.48, 95% CI 1.16 to 5.30; typical RD 0.09, 95% CI 0.02 to 0.16; number needed to treat for an additional harmful outcome (NNTH) 11, 95% CI 7 to 50; I2 = 0%; 4 studies, 274 infants; low-certainty evidence). There was no evidence of a difference in bronchopulmonary dysplasia, defined as oxygen dependency at 28 days (RR 1.04, 95% CI 0.35 to 3.13; I2 = 0%; 2 studies, 209 infants; very low-certainty evidence). The trials did not report use of surfactant, intraventricular haemorrhage, retinopathy of prematurity, necrotising enterocolitis and neurodevelopment outcomes in childhood.
AUTHORS' CONCLUSIONS: In preterm infants with respiratory distress, the application of CPAP is associated with reduced respiratory failure, use of mechanical ventilation and mortality and an increased rate of pneumothorax compared to spontaneous breathing with supplemental oxygen as necessary. Three out of five of these trials were conducted in the 1970s. Therefore, the applicability of these results to current practice is unclear. Further studies in resource-poor settings should be considered and research to determine the most appropriate pressure level needs to be considered.
AIM: Our aim is to develop and validate a pharmaceutical assessment screening tool (PAST) to guide medical ward pharmacists in our local hospitals to effectively prioritise patient care.
METHOD: This study involved 2 major phases; (1) development of PAST through literature review and group discussion, (2) validation of PAST using a three-round Delphi survey. Twenty-four experts were invited by email to participate in the Delphi survey. In each round, experts were required to rate the relevance and completeness of PAST criteria and were given chance for open feedback. The 75% consensus benchmark was set and criteria with achieved consensus were retained in PAST. Experts' suggestions were considered and added into PAST for rating. After each round, experts were provided with anonymised feedback and results from the previous round.
RESULTS: Three Delphi rounds resulted in the final tool (rearranged as mnemonic 'STORIMAP'). STORIMAP consists of 8 main criteria with 29 subcomponents. Marks are allocated for each criteria in STORIMAP which can be combined to a total of 15 marks. Patient acuity level is determined based on the final score and clerking priority is assigned accordingly.
CONCLUSION: STORIMAP potentially serves as a useful tool to guide medical ward pharmacists to prioritise patients effectively, hence establishing acuity-based pharmaceutical care.
OBJECTIVES: • To determine if early compared with delayed initiation of CPAP results in lower mortality and reduced need for intermittent positive-pressure ventilation in preterm infants in respiratory distress ○ Subgroup analyses were planned a priori on the basis of weight (with subdivisions at 1000 grams and 1500 grams), gestation (with subdivisions at 28 and 32 weeks), and according to whether surfactant was used ▫ Sensitivity analyses based on trial quality were also planned ○ For this update, we have excluded trials using continuous negative pressure SEARCH METHODS: We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL; 2020, Issue 6), in the Cochrane Library; Ovid MEDLINE(R) and Epub Ahead of Print, In-Process & Other Non-Indexed Citations Daily and Versions(R); and the Cumulative Index to Nursing and Allied Health Literatue (CINAHL), on 30 June 2020. We also searched clinical trials databases and the reference lists of retrieved articles for randomised controlled trials (RCTs) and quasi-RCTs.
SELECTION CRITERIA: We included trials that used random or quasi-random allocation to either early or delayed CPAP for spontaneously breathing preterm infants in respiratory distress.
DATA COLLECTION AND ANALYSIS: We used the standard methods of Cochrane and Cochrane Neonatal, including independent assessment of trial quality and extraction of data by two review authors. We used the GRADE approach to assess the certainty of evidence.
MAIN RESULTS: We found four studies that recruited a total of 119 infants. Two were quasi-randomised, and the other two did not provide details on the method of randomisation or allocation used. None of these studies used blinding of the intervention or the outcome assessor. Evidence showed uncertainty about whether early CPAP has an effect on subsequent use of intermittent positive-pressure ventilation (IPPV) (typical risk ratio (RR) 0.77, 95% confidence interval (CI) 0.43 to 1.38; typical risk difference (RD) -0.08, 95% CI -0.23 to 0.08; I² = 0%, 4 studies, 119 infants; very low-certainty evidence) or mortality (typical RR 0.93, 95% CI 0.43 to 2.03; typical RD -0.02, 95% CI -0.15 to 0.12; I² = 33%, 4 studies, 119 infants; very low-certainty evidence). The outcome 'failed treatment' was not reported in any of these studies. There was an uncertain effect on air leak (pneumothorax) (typical RR 1.09, 95% CI 0.39 to 3.04, I² = 0%, 3 studies, 98 infants; very low-certainty evidence). No trials reported intraventricular haemorrhage or necrotising enterocolitis. No cases of retinopathy of prematurity were reported in one study (21 infants). One case of bronchopulmonary dysplasia was reported in each group in one study involving 29 infants. Long-term outcomes were not reported.
AUTHORS' CONCLUSIONS: All four small trials included in this review were performed in the 1970s or the early 1980s, and we are very uncertain whether early application of CPAP confers clinical benefit in the treatment of respiratory distress, or whether it is associated with any adverse effects. Further trials should be directed towards establishing the appropriate level of CPAP and the timing and method of administration of surfactant when used along with CPAP.
METHODS: A single-arm interventional pre-and post-pilot study was conducted on a sample of healthcare lecturers and workers who are involved in supervising healthcare students. A purposive sampling technique was used to recruit 50 healthcare educators in Malaysia. The program was conducted by trained facilitators and 31 participants completed a locally validated self-rated questionnaire to measure their self-efficacy and declarative knowledge in preventing suicide; immediately before and after the intervention.
RESULTS: Significant improvement was seen in the overall outcome following the intervention, mostly in the self-efficacy domain. No significant improvement was seen in the domain of declarative knowledge possibly due to ceiling effects; an already high baseline knowledge about suicide among healthcare workers. This is an exception in a single item that assesses a common misperception in assessing suicide risk where significant improvement was seen following the program.
CONCLUSION: The online Advanced C.A.R.E. Suicide Prevention Gatekeeper Training Program is promising in the short-term overall improvement in suicide prevention, primarily in self-efficacy.