Methods: This study was carried out between June and December 2017. All 48 paediatric surgeons currently working in Malaysia were invited to participate in a questionnaire-based survey to assess demographic characteristics and practices and perspectives regarding TOC.
Results: A total of 38 paediatric surgeons participated in the survey (response rate: 79.2%). Overall, 97.4% did not have an organised TOC model in their institution, with most (65.8%) caring for paediatric patients with complex surgical conditions until adulthood. Although the majority (86.8%) felt that care should be transitioned to adult surgeons with appropriate credentials, most surgeons (84.2%) nevertheless preferred to be involved in the management of adolescent patients after transition. However, there was no consensus regarding the most suitable age to begin the transition. Years of experience as a paediatric surgeon and place of practice did not affect overall TOC practice scores (P >0.050 each). The presence of adult comorbidities was considered the most common reason to initiate TOC (81.6%), while the lack of TOC guidelines was perceived to be the greatest barrier (84.2%).
Conclusion: This study provides a better understanding of TOC from the point of view of paediatric surgeons in Malaysia. However, further studies involving other stakeholders (i.e. patients and adult surgeons) are needed to help formulate a suitable and successful TOC model in this setting.
METHODS: Relations between skeletal movement, hyoid bone position and three-dimensional pharyngeal airway changes were retrospectively analyzed on pre- and post-surgical CBCTs in dento-skeletal class II patients who underwent orthognathic two-jaw surgery with segmentation.
RESULTS: While long-term significant reductions in length (P= 0.003), surface area (P= 0.042) and volume (P= 0.004) were found in the nasopharynx, the highly significant increases in oropharyngeal airway length, surface area, volume and the minimal cross-sectional area (P
METHODS: A retrospective analysis has been performed on patients with dento-skeletal class III deformity who had undergone orthognathic 2-jaw surgery with segmentations, presenting both pre- and post-surgical cone-beam computed tomographys. Three-dimensional skeletal movements, pharyngeal airway changes and hyoid bone position were measured and correlated.
RESULTS: The mean short term postsurgical review period for all included 47 patients was 5.8 ± 2.2 months. Thirteen patients among them provided a mean long term period of 26.4 ± 3.4 months. The mean postsurgical maxillary movement was 2.29 ± 2.49 mm in vertical, 2.02 ± 3.45 mm in horizontal direction, respectively, while the mandibular movement was 6.49 ± 4.58 mm in vertical, and -5.85 ± 6.13 mm in horizontal direction. In short-term, the vertical length of nasopharynx was found to be reduced (P = 0.005) but increased for the oropharynx (P 0.05) detected between patients with and without genioplasty advancement.
CONCLUSION: Two-jaw orthognathic surgery in dento-skeletal class III patients led to a statistically non-significant reduction of the post-surgical airway volume in both short- and long-term. Although the post-surgical oropharyneal minimum cross-sectional area was decreased significantly in the short term, this finding did not persist in the long term.
METHODS: Randomized controlled trials and cohort studies with a minimum 2-year follow-up assessing survival and complication rates of resin composite laminate veneers on permanent dentition from 1998 to May 2022. Literature searches were conducted in MEDLINE (PubMed), Scopus, and the Cochrane Central Register of Controlled Trials electronic databases. References cited in the related reviews and included full-text articles were also hand-searched to further identify potentially relevant studies.
RESULTS: A total of 827 articles were identified. Twenty-two studies were considered for full-text review after the title and abstract screening stage. After exclusion, 7 studies (3 randomized controlled trials and 4 cohort studies) were included in the systematic review. Three published scales were adopted for the quality and risk of bias assessment. At the survival rate threshold, the overall heterogeneity (I2) for randomized controlled trials was 50.5% (P = .108). The overall pooled survival rate of the randomized controlled trials was 88% (95% CI: 81%-94%), with the mean follow-up time ranging from 24 to 97 months. Surface roughness, color mismatch, and marginal discoloration were the most reported complications.
CONCLUSION: Resin composite laminate veneers demonstrated moderately high survival rates for the entire sample and the direct laminate veneer group demonstrated higher survival rates than the indirect approach. Most of the complications were regarded as clinically acceptable with or without reintervention.
MATERIALS AND METHODS: Prospectively ECG-triggered CCTA was performed using five commercially available CT scanners: 64-detector-row single source CT (SSCT), 2 × 32-detector-row-dual source CT (DSCT), 2 × 64-detector-row DSCT and 320-detector-row SSCT scanners. Absorbed doses were measured in 34 organs using pre-calibrated optically stimulated luminescence dosimeters (OSLDs) placed inside a standard female adult anthropomorphic phantom. HE was calculated from the measured organ doses and compared to the HE derived from the air kerma-length product (PKL) using the conversion coefficient of 0.014 mSv∙mGy-1∙cm-1 for the chest region.
RESULTS: Both breasts and lungs received the highest radiation dose during CCTA examination. The highest HE was received from 2 × 32-detector-row DSCT scanner (6.06 ± 0.72 mSv), followed by 64-detector-row SSCT (5.60 ± 0.68 and 5.02 ± 0.73 mSv), 2 × 64-detector-row DSCT (1.88 ± 0.25 mSv) and 320-detector-row SSCT (1.34 ± 0.48 mSv) scanners. HE calculated from the measured organ doses were about 38 to 53% higher than the HE derived from the PKL-to-HE conversion factor.
CONCLUSION: The radiation doses received from a prospectively ECG-triggered CCTA are relatively small and are depending on the scanner technology and imaging protocols. HE as low as 1.34 and 1.88 mSv can be achieved in prospectively ECG-triggered CCTA using 320-detector-row SSCT and 2 × 64-detector-row DSCT scanners.
Methods: The algorithm for an IDR of 2.22 gI·s-1 was developed based on the relationship between VCE and contrast volume in 141 patients; test bolus parameters and characteristics in 75 patients; and, tube voltage in a phantom study. The algorithm was retrospectively tested in 45 patients who underwent retrospectively ECG-gated CCTA with a 100 kVp protocol. Image quality, TID and radiation dose exposure were compared with those produced using the 120 kVp and routine contrast protocols.
Results: Age, sex, body surface area (BSA) and peak contrast enhancement (PCE) were significant predictors for VCE (P<0.05). A strong linear correlation was observed between VCE and contrast volume (r=0.97, P<0.05). The 100-to-120 kVp contrast enhancement conversion factor (Ec) was calculated at 0.81. Optimal VCE (250 to 450 HU) and diagnostic image quality were obtained with significant reductions in TID (32.1%) and radiation dose (38.5%) when using 100 kVp and personalized contrast volume calculation algorithm compared with 120 kVp and routine contrast protocols (P<0.05).
Conclusions: The proposed algorithm could significantly reduce TID and radiation exposure while maintaining optimal VCE and image quality in CCTA with 100 kVp protocol.
METHODS: The questionnaires for thirteen orthognathic-relevant FACE-Q scales, translated into Cantonese and validated, were administered to Hong Kong Chinese patients before and after orthognathic surgery in the short- and long-term, respectively. The assessed scales were categorized into four main domains: satisfaction with facial appearance, quality of life, patient's experience of care, and adverse effects.
RESULTS: Generally, highly significant (p
Methods: Two hundred fifty adult Cantonese-speaking patients of 18 years or older who underwent orthognathic treatment were recruited in the Prince Philip Dental Hospital of Hong Kong. Nine of an overall of 40 independent FACE-Q scales were selected and translated into Hong Kong Chinese. The reliability, validity, and test-retest reliability were examined using Cronbach's alpha, paired t test and Pearson's correlation coefficients.
Results: The Hong Kong Chinese version of the 9 FACE-Q scales was obtained by forward-backward translation. One hundred eight male (mean age, 25.57 ± 4.49) and 142 female (mean age, 24.61 ± 4.54) patients were recruited for the reliability and validation process. The internal consistency (0.89-0.97) and the test-retest reliability (0.73-0.90) were found to be high. The validity of the translated questionnaires was comparable with that of the original FACE-Q.
Conclusion: The results presented here prove that the 9 translated FACE-Q scales are reliable and valid instruments for research and clinical purposes in Hong Kong Chinese orthognathic patients.
METHODS: The questionnaire was distributed physically and digitally to non-OGS users aged above 60, living in the Klang Valley, Malaysia, using a non-probability sampling approach. A total of 302 data were analysed using PLS structural equation modelling.
RESULTS: The findings indicate that perceived ease of use, functional ability, life-course events, and digital literacy are associated with the elderly's perception of OGS's usefulness, while life-course events, digital literacy, technology anxiety, and facilitating conditions are associated with the perceived ease of use.
CONCLUSION: This study contributes to the OGS literature by addressing ageing complexities with OGS adoption among the elderly population, thereby offering insights for marketers and the government to tailor services and provide relevant support.
MATERIALS AND METHODS: Nine phantoms were fabricated with different bifurcation angles ranging from 55.3° to 134.5°. General X-ray and CCTA were employed to acquire 2D and 3D images of the bifurcation phantoms, respectively. Multiplanar reformation (MPR) and volume rendering technique (VRT) were used to measure the bifurcation angle between the left anterior descending (LAD) and left circumflex arteries (LCx). The measured angles were compared with the true values to determine the accuracy of each measurement technique. Inter-observer variability was evaluated. The two techniques were further applied on 50 clinical CCTA cases to verify its clinical value.
RESULTS: In the phantom setting, the mean absolute differences calculated between the true and measured angles by MPR and VRT were 2.4°±2.2° and 3.8°±2.9°, respectively. Strong correlation was found between the true and measured bifurcation angles. Furthermore, no significant differences were found between the bifurcation angles measured using either technique. In clinical settings, large difference of 12.0°±10.6° was found between the two techniques.
CONCLUSION: In the phantom setting, both techniques demonstrated a significant correlation to the true bifurcation angle. Despite the lack of agreement of the two techniques in the clinical context, our findings in phantoms suggest that MPR should be preferred to VRT for the measurement of coronary bifurcation angle by CCTA.
METHODS: A systematic search was performed in PubMed, the Cochrane library, CINAHL, Web of Science, ScienceDirect and Scopus, where 20 studies were selected for analysis of scanning parameters and CM reduction methods.
RESULTS: The mean effective dose (HE) ranged from 0.31 to 2.75 mSv at 80 kVp, 0.69 to 6.29 mSv at 100 kVp and 1.53 to 10.7 mSv at 120 kVp. Radiation dose reductions of 38 to 83% at 80 kVp and 3 to 80% at 100 kVp could be achieved with preserved image quality. Similar vessel contrast enhancement to 120 kVp could be obtained by applying iodine delivery rate (IDR) of 1.35 to 1.45 g s-1 with total iodine dose (TID) of between 10.9 and 16.2 g at 80 kVp and IDR of 1.08 to 1.70 g s-1 with TID of between 18.9 and 20.9 g at 100 kVp.
CONCLUSION: This systematic review found that radiation doses could be reduced to a rate of 38 to 83% at 80 kVp, and 3 to 80% at 100 kVp without compromising the image quality. Advances in knowledge: The suggested appropriate scanning parameters and CM reduction methods can be used to help users in achieving diagnostic image quality with reduced radiation dose.