Displaying publications 1 - 20 of 40 in total

Abstract:
Sort:
  1. Tan SK, Sanmugam A, Danaee M, Ramanujam TM, Nallusamy MA, Zahari Z, et al.
    Sultan Qaboos Univ Med J, 2019 Nov;19(4):e352-e358.
    PMID: 31897319 DOI: 10.18295/squmj.2019.19.04.011
    Objectives: Transition of care (TOC) from paediatric to adult care is still at an early stage in Malaysia. This study aimed to explore current practices and perspectives regarding TOC among paediatric surgeons in Malaysia.

    Methods: This study was carried out between June and December 2017. All 48 paediatric surgeons currently working in Malaysia were invited to participate in a questionnaire-based survey to assess demographic characteristics and practices and perspectives regarding TOC.

    Results: A total of 38 paediatric surgeons participated in the survey (response rate: 79.2%). Overall, 97.4% did not have an organised TOC model in their institution, with most (65.8%) caring for paediatric patients with complex surgical conditions until adulthood. Although the majority (86.8%) felt that care should be transitioned to adult surgeons with appropriate credentials, most surgeons (84.2%) nevertheless preferred to be involved in the management of adolescent patients after transition. However, there was no consensus regarding the most suitable age to begin the transition. Years of experience as a paediatric surgeon and place of practice did not affect overall TOC practice scores (P >0.050 each). The presence of adult comorbidities was considered the most common reason to initiate TOC (81.6%), while the lack of TOC guidelines was perceived to be the greatest barrier (84.2%).

    Conclusion: This study provides a better understanding of TOC from the point of view of paediatric surgeons in Malaysia. However, further studies involving other stakeholders (i.e. patients and adult surgeons) are needed to help formulate a suitable and successful TOC model in this setting.

  2. Tan SK, Tang ATH, Leung WK, Zwahlen RA
    J Stomatol Oral Maxillofac Surg, 2018 Dec;119(6):461-468.
    PMID: 30099221 DOI: 10.1016/j.jormas.2018.07.004
    PURPOSE: To investigate short- and long-term post-surgical three-dimensional changes of pharyngeal airway morphology and hyoid bone position in dento-skeletal class II deformity patients after two-jaw surgery with segmentation.

    METHODS: Relations between skeletal movement, hyoid bone position and three-dimensional pharyngeal airway changes were retrospectively analyzed on pre- and post-surgical CBCTs in dento-skeletal class II patients who underwent orthognathic two-jaw surgery with segmentation.

    RESULTS: While long-term significant reductions in length (P= 0.003), surface area (P= 0.042) and volume (P= 0.004) were found in the nasopharynx, the highly significant increases in oropharyngeal airway length, surface area, volume and the minimal cross-sectional area (P 

  3. Tan SK, Tang ATH, Leung WK, Zwahlen RA
    J Craniofac Surg, 2019 Mar 28.
    PMID: 30946225 DOI: 10.1097/SCS.0000000000005351
    PURPOSE: To investigate short- and long-term three-dimensional changes of pharyngeal airway morphology and hyoid bone position in dento-skeletal class III deformity patients after 2-jaw orthognathic surgery with segmentation.

    METHODS: A retrospective analysis has been performed on patients with dento-skeletal class III deformity who had undergone orthognathic 2-jaw surgery with segmentations, presenting both pre- and post-surgical cone-beam computed tomographys. Three-dimensional skeletal movements, pharyngeal airway changes and hyoid bone position were measured and correlated.

    RESULTS: The mean short term postsurgical review period for all included 47 patients was 5.8 ± 2.2 months. Thirteen patients among them provided a mean long term period of 26.4 ± 3.4 months. The mean postsurgical maxillary movement was 2.29 ± 2.49 mm in vertical, 2.02 ± 3.45 mm in horizontal direction, respectively, while the mandibular movement was 6.49 ± 4.58 mm in vertical, and -5.85 ± 6.13 mm in horizontal direction. In short-term, the vertical length of nasopharynx was found to be reduced (P = 0.005) but increased for the oropharynx (P  0.05) detected between patients with and without genioplasty advancement.

    CONCLUSION: Two-jaw orthognathic surgery in dento-skeletal class III patients led to a statistically non-significant reduction of the post-surgical airway volume in both short- and long-term. Although the post-surgical oropharyneal minimum cross-sectional area was decreased significantly in the short term, this finding did not persist in the long term.

  4. Dora Tan SK
    Med J Malaysia, 1972 Dec;27(2):129-133.
    PMID: 35158491
    No abstract available.
  5. Tan SH, Habibullah MS, Tan SK, Choon SW
    J Environ Manage, 2017 Dec 01;203(Pt 1):603-611.
    PMID: 28285804 DOI: 10.1016/j.jenvman.2017.02.029
    This study investigates the impact of the aggregate and individual dimensions of environmental performance (EP) on financial performance (FP), based on a dataset covering the travel and tourism industry (airlines, casinos, hotels, and restaurants) across different economic regions over the period 2003-2014. The results reveal that EP positively affects the FP in the hotel industry when aggregate EP is used. When individual dimensions of EP are considered, resource reduction is found to positively (negatively) affect the performance in the hotel (airline) industry, while product innovation positively affects the performance in the restaurant industry. Hence, the trade-off effect seems to be dominant in the airline industry, and the 'heterogeneous resources and reputation-building' hypothesis is evident in both the hotel and restaurant industries. In addition, in general, the findings support the positive moderating effect of slack resources on the relationship between the individual dimensions of EP and FP in the travel and tourism industry, and, hence, are supportive of the slack resources hypothesis. These effects, however, vary depending on the travel and tourism industry under investigation.
  6. Dayrat B, Goulding TC, Apte D, Aslam S, Bourke A, Comendador J, et al.
    Zookeys, 2020;972:1-224.
    PMID: 33071542 DOI: 10.3897/zookeys.972.52853
    The genus Peronia Fleming, 1822 includes all the onchidiid slugs with dorsal gills. Its taxonomy is revised for the first time based on a large collection of fresh material from the entire Indo-West Pacific, from South Africa to Hawaii. Nine species are supported by mitochondrial (COI and 16S) and nuclear (ITS2 and 28S) sequences as well as comparative anatomy. All types available were examined and the nomenclatural status of each existing name in the genus is addressed. Of 31 Peronia species-group names available, 27 are regarded as invalid (twenty-one synonyms, sixteen of which are new, five nomina dubia, and one homonym), and four as valid: Peronia peronii (Cuvier, 1804), Peronia verruculata (Cuvier, 1830), Peronia platei (Hoffmann, 1928), and Peronia madagascariensis (Labbé, 1934a). Five new species names are created: P. griffithsi Dayrat & Goulding, sp. nov., P. okinawensis Dayrat & Goulding, sp. nov., P. setoensis Dayrat & Goulding, sp. nov., P. sydneyensis Dayrat & Goulding, sp. nov., and P. willani Dayrat & Goulding, sp. nov.Peronia species are cryptic externally but can be distinguished using internal characters, with the exception of P. platei and P. setoensis. The anatomy of most species is described in detail here for the first time. All the secondary literature is commented on and historical specimens from museum collections were also examined to better establish species distributions. The genus Peronia includes two species that are widespread across the Indo-West Pacific (P. verruculata and P. peronii) as well as endemic species: P. okinawensis and P. setoensis are endemic to Japan, and P. willani is endemic to Northern Territory, Australia. Many new geographical records are provided, as well as a key to the species using morphological traits.
  7. Lim TW, Tan SK, Li KY, Burrow MF
    J Evid Based Dent Pract, 2023 Dec;23(4):101911.
    PMID: 38035903 DOI: 10.1016/j.jebdp.2023.101911
    OBJECTIVES: The aim of this systematic review was to evaluate the survival and complication rates of resin composite laminate veneers.

    METHODS: Randomized controlled trials and cohort studies with a minimum 2-year follow-up assessing survival and complication rates of resin composite laminate veneers on permanent dentition from 1998 to May 2022. Literature searches were conducted in MEDLINE (PubMed), Scopus, and the Cochrane Central Register of Controlled Trials electronic databases. References cited in the related reviews and included full-text articles were also hand-searched to further identify potentially relevant studies.

    RESULTS: A total of 827 articles were identified. Twenty-two studies were considered for full-text review after the title and abstract screening stage. After exclusion, 7 studies (3 randomized controlled trials and 4 cohort studies) were included in the systematic review. Three published scales were adopted for the quality and risk of bias assessment. At the survival rate threshold, the overall heterogeneity (I2) for randomized controlled trials was 50.5% (P = .108). The overall pooled survival rate of the randomized controlled trials was 88% (95% CI: 81%-94%), with the mean follow-up time ranging from 24 to 97 months. Surface roughness, color mismatch, and marginal discoloration were the most reported complications.

    CONCLUSION: Resin composite laminate veneers demonstrated moderately high survival rates for the entire sample and the direct laminate veneer group demonstrated higher survival rates than the indirect approach. Most of the complications were regarded as clinically acceptable with or without reintervention.

  8. Tan SK, Yeong CH, Ng KH, Abdul Aziz YF, Sun Z
    PLoS One, 2016;11(8):e0161543.
    PMID: 27552224 DOI: 10.1371/journal.pone.0161543
    OBJECTIVES: This study aimed to measure the absorbed doses in selected organs for prospectively ECG-triggered coronary computed tomography angiography (CCTA) using five different generations CT scanners in a female adult anthropomorphic phantom and to estimate the effective dose (HE).

    MATERIALS AND METHODS: Prospectively ECG-triggered CCTA was performed using five commercially available CT scanners: 64-detector-row single source CT (SSCT), 2 × 32-detector-row-dual source CT (DSCT), 2 × 64-detector-row DSCT and 320-detector-row SSCT scanners. Absorbed doses were measured in 34 organs using pre-calibrated optically stimulated luminescence dosimeters (OSLDs) placed inside a standard female adult anthropomorphic phantom. HE was calculated from the measured organ doses and compared to the HE derived from the air kerma-length product (PKL) using the conversion coefficient of 0.014 mSv∙mGy-1∙cm-1 for the chest region.

    RESULTS: Both breasts and lungs received the highest radiation dose during CCTA examination. The highest HE was received from 2 × 32-detector-row DSCT scanner (6.06 ± 0.72 mSv), followed by 64-detector-row SSCT (5.60 ± 0.68 and 5.02 ± 0.73 mSv), 2 × 64-detector-row DSCT (1.88 ± 0.25 mSv) and 320-detector-row SSCT (1.34 ± 0.48 mSv) scanners. HE calculated from the measured organ doses were about 38 to 53% higher than the HE derived from the PKL-to-HE conversion factor.

    CONCLUSION: The radiation doses received from a prospectively ECG-triggered CCTA are relatively small and are depending on the scanner technology and imaging protocols. HE as low as 1.34 and 1.88 mSv can be achieved in prospectively ECG-triggered CCTA using 320-detector-row SSCT and 2 × 64-detector-row DSCT scanners.

  9. Mustafa NWNA, Ahmad R, Ahmad Khushaini MA, Kamar Affendi NH, Ab Ghani SM, Tan SK, et al.
    ACS Biomater Sci Eng, 2024 Jan 08;10(1):405-419.
    PMID: 38040671 DOI: 10.1021/acsbiomaterials.3c01551
    This study assessed the corrosion resistance, intracutaneous reactivity, acute systemic toxicity, and in situ tissue effect of the implantation of porous NiTi fabricated by metal injection molding in animal models. For the intracutaneous reactivity study, five intracutaneous injections were administered per site with and without the tested extract in polar and nonpolar solutions. The extract was also delivered via intravenous and intraperitoneal routes for acute systemic toxicity. TiAl6 V4 (control) and porous NiTi were implanted in rabbit femora for a period of 13 weeks to evaluate the in situ tissue response. Corrosion was evaluated through open and cyclic polarization in PBS, while biocompatibility was investigated by assessing the general conditions, skin irritation score (edema and erythema), and histopathology. No active dissolution or hysteresis loop was observed in the corrosion study. None of the animals exhibited death, moribundity, impending death, severe pain, self-mutilation, or overgrooming. No edema was observed at injection sites. Only the positive control showed an erythematous reaction at 24, 48, and 72 h observations (p < 0.001). Porous NiTi showed a low in situ biological response for inflammation, neovascularization, and fibrosis in comparison to the control implant (p = 0.247, 0.005, and 0.011, respectively). Porous NiTi also demonstrated high pitting corrosion resistance while causing no acute hypersensitivity or acute systemic toxicity. The study concludes that porous NiTi implants were unlikely to cause local sensitization, acute systemic toxicity, or chronic inflammatory reactions in an animal model. Porous NiTi also exhibited osseointegration equivalent to Ti6AI4 V of known biocompatibility.
  10. Tan SK, Ng KH, Yeong CH, Raja Aman RRA, Mohamed Sani F, Abdul Aziz YF, et al.
    Quant Imaging Med Surg, 2019 Apr;9(4):552-564.
    PMID: 31143647 DOI: 10.21037/qims.2019.03.13
    Background: High delivery rate is an important factor in optimizing contrast medium administration in coronary computed tomography angiography (CCTA). A personalized contrast volume calculation algorithm incorporating high iodine delivery rate (IDR) can reduce total iodine dose (TID) and produce optimal vessel contrast enhancement (VCE) in low tube voltage CCTA. In this study, we developed and validated an algorithm for calculating the volume of contrast medium delivered at a high rate for patients undergoing retrospectively ECG-gated CCTA with low tube voltage protocol.

    Methods: The algorithm for an IDR of 2.22 gI·s-1 was developed based on the relationship between VCE and contrast volume in 141 patients; test bolus parameters and characteristics in 75 patients; and, tube voltage in a phantom study. The algorithm was retrospectively tested in 45 patients who underwent retrospectively ECG-gated CCTA with a 100 kVp protocol. Image quality, TID and radiation dose exposure were compared with those produced using the 120 kVp and routine contrast protocols.

    Results: Age, sex, body surface area (BSA) and peak contrast enhancement (PCE) were significant predictors for VCE (P<0.05). A strong linear correlation was observed between VCE and contrast volume (r=0.97, P<0.05). The 100-to-120 kVp contrast enhancement conversion factor (Ec) was calculated at 0.81. Optimal VCE (250 to 450 HU) and diagnostic image quality were obtained with significant reductions in TID (32.1%) and radiation dose (38.5%) when using 100 kVp and personalized contrast volume calculation algorithm compared with 120 kVp and routine contrast protocols (P<0.05).

    Conclusions: The proposed algorithm could significantly reduce TID and radiation exposure while maintaining optimal VCE and image quality in CCTA with 100 kVp protocol.

  11. Tan SK, Leung WK, Tang ATH, Zwahlen RA
    J Craniomaxillofac Surg, 2020 Dec;48(12):1106-1111.
    PMID: 33041190 DOI: 10.1016/j.jcms.2020.09.012
    PURPOSE: To assess and compare the changes in satisfaction with facial appearance and psycho-social well-being in dento-skeletal class II and III patients after orthognathic surgery with the FACE-Q among Hong Kong Chinese.

    METHODS: The questionnaires for thirteen orthognathic-relevant FACE-Q scales, translated into Cantonese and validated, were administered to Hong Kong Chinese patients before and after orthognathic surgery in the short- and long-term, respectively. The assessed scales were categorized into four main domains: satisfaction with facial appearance, quality of life, patient's experience of care, and adverse effects.

    RESULTS: Generally, highly significant (p 

  12. Tan SK, Leung WK, Tang ATH, Tse ECM, Zwahlen RA
    Plast Reconstr Surg Glob Open, 2017 Dec;5(12):e1608.
    PMID: 29610716 DOI: 10.1097/GOX.0000000000001608
    Background: A validated questionnaire is needed to study a more holistic outcome assessment including postsurgical aesthetic satisfaction and psychosocial changes in orthognathic patients. The aim of this study was to determine the reliability and validity of 9 orthognathically relevant translated FACE-Q scales among Hong Kong Chinese orthognathic patients.

    Methods: Two hundred fifty adult Cantonese-speaking patients of 18 years or older who underwent orthognathic treatment were recruited in the Prince Philip Dental Hospital of Hong Kong. Nine of an overall of 40 independent FACE-Q scales were selected and translated into Hong Kong Chinese. The reliability, validity, and test-retest reliability were examined using Cronbach's alpha, paired t test and Pearson's correlation coefficients.

    Results: The Hong Kong Chinese version of the 9 FACE-Q scales was obtained by forward-backward translation. One hundred eight male (mean age, 25.57 ± 4.49) and 142 female (mean age, 24.61 ± 4.54) patients were recruited for the reliability and validation process. The internal consistency (0.89-0.97) and the test-retest reliability (0.73-0.90) were found to be high. The validity of the translated questionnaires was comparable with that of the original FACE-Q.

    Conclusion: The results presented here prove that the 9 translated FACE-Q scales are reliable and valid instruments for research and clinical purposes in Hong Kong Chinese orthognathic patients.

  13. Yap YY, Tan SH, Tan SK, Choon SW
    Heliyon, 2023 Oct;9(10):e20827.
    PMID: 37916123 DOI: 10.1016/j.heliyon.2023.e20827
    PURPOSE: This study investigates the factors associated with the elderly's intention to use OGS. Building on the Technology Acceptance Model, we propose several elderly-specific and functional-ageing constructs related to the perceived ease of use and usefulness of OGS.

    METHODS: The questionnaire was distributed physically and digitally to non-OGS users aged above 60, living in the Klang Valley, Malaysia, using a non-probability sampling approach. A total of 302 data were analysed using PLS structural equation modelling.

    RESULTS: The findings indicate that perceived ease of use, functional ability, life-course events, and digital literacy are associated with the elderly's perception of OGS's usefulness, while life-course events, digital literacy, technology anxiety, and facilitating conditions are associated with the perceived ease of use.

    CONCLUSION: This study contributes to the OGS literature by addressing ageing complexities with OGS adoption among the elderly population, thereby offering insights for marketers and the government to tailor services and provide relevant support.

  14. Givehchi S, Safari MJ, Tan SK, Md Shah MNB, Sani FBM, Azman RR, et al.
    Phys Med, 2018 Jan;45:198-204.
    PMID: 29373248 DOI: 10.1016/j.ejmp.2017.09.137
    PURPOSE: Accurate determination of the bifurcation angle and correlation with plaque buildup may lead to the prediction of coronary artery disease (CAD). This work evaluates two techniques to measure bifurcation angles in 3D space using coronary computed tomography angiography (CCTA).

    MATERIALS AND METHODS: Nine phantoms were fabricated with different bifurcation angles ranging from 55.3° to 134.5°. General X-ray and CCTA were employed to acquire 2D and 3D images of the bifurcation phantoms, respectively. Multiplanar reformation (MPR) and volume rendering technique (VRT) were used to measure the bifurcation angle between the left anterior descending (LAD) and left circumflex arteries (LCx). The measured angles were compared with the true values to determine the accuracy of each measurement technique. Inter-observer variability was evaluated. The two techniques were further applied on 50 clinical CCTA cases to verify its clinical value.

    RESULTS: In the phantom setting, the mean absolute differences calculated between the true and measured angles by MPR and VRT were 2.4°±2.2° and 3.8°±2.9°, respectively. Strong correlation was found between the true and measured bifurcation angles. Furthermore, no significant differences were found between the bifurcation angles measured using either technique. In clinical settings, large difference of 12.0°±10.6° was found between the two techniques.

    CONCLUSION: In the phantom setting, both techniques demonstrated a significant correlation to the true bifurcation angle. Despite the lack of agreement of the two techniques in the clinical context, our findings in phantoms suggest that MPR should be preferred to VRT for the measurement of coronary bifurcation angle by CCTA.

  15. Tan SK, Yeong CH, Raja Aman RRA, Ng KH, Abdul Aziz YF, Chee KH, et al.
    Br J Radiol, 2018 Jul;91(1088):20170874.
    PMID: 29493261 DOI: 10.1259/bjr.20170874
    OBJECTIVE: This study aimed (1) to perform a systematic review on scanning parameters and contrast medium (CM) reduction methods used in prospectively electrocardiography (ECG-triggered low tube voltage coronary CT angiography (CCTA), (2) to compare the achievable dose reduction and image quality and (3) to propose appropriate scanning techniques and CM administration methods.

    METHODS: A systematic search was performed in PubMed, the Cochrane library, CINAHL, Web of Science, ScienceDirect and Scopus, where 20 studies were selected for analysis of scanning parameters and CM reduction methods.

    RESULTS: The mean effective dose (HE) ranged from 0.31 to 2.75 mSv at 80 kVp, 0.69 to 6.29 mSv at 100 kVp and 1.53 to 10.7 mSv at 120 kVp. Radiation dose reductions of 38 to 83% at 80 kVp and 3 to 80% at 100 kVp could be achieved with preserved image quality. Similar vessel contrast enhancement to 120 kVp could be obtained by applying iodine delivery rate (IDR) of 1.35 to 1.45 g s-1 with total iodine dose (TID) of between 10.9 and 16.2 g at 80 kVp and IDR of 1.08 to 1.70 g s-1 with TID of between 18.9 and 20.9 g at 100 kVp.

    CONCLUSION: This systematic review found that radiation doses could be reduced to a rate of 38 to 83% at 80 kVp, and 3 to 80% at 100 kVp without compromising the image quality. Advances in knowledge: The suggested appropriate scanning parameters and CM reduction methods can be used to help users in achieving diagnostic image quality with reduced radiation dose.

  16. Cheng N, Lee GK, Yap BS, Lee LT, Tan SK, Tan KP
    J Forensic Sci, 2005 Jan;50(1):177-84.
    PMID: 15831016
    This paper investigated the class characteristics in English handwriting of the Chinese, Malays and Indians in Singapore, many of whom learned their native language as a second language. One hundred and fifty-four handwriting exemplars were collected and features such as letter designs, pen-lifts, letter spacing and embellishments were studied. A number of characteristic features peculiar to the individual racial group were identified, which confirmed the impact of their native language writing systems on English handwriting.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)