  1. Ulhaq A, Esmail Z, Kamaruddin A, Meadows S, Daus J, Vitale M, et al.
    Am J Orthod Dentofacial Orthop, 2017 Dec;152(6):744-752.
    PMID: 29173854 DOI: 10.1016/j.ajodo.2017.07.014
    INTRODUCTION: The objective of this 4-arm parallel study was to evaluate the alignment efficiency and esthetic performance of 4 coated nickel-titanium archwires over an 8-week period.

    METHODS: Patients in the permanent dentition requiring maxillary and mandibular fixed orthodontic treatment with a preadjusted edgewise appliance were eligible for inclusion. Patients attending 4 hospital departments (United Kingdom and Italy) were randomly allocated to 1 of 4 treatment interventions: (1) BioCosmetic (Forestadent, Pforzheim, Germany), 0.017 in; (2) Titanol (Forestadent), 0.016 in; (3) TP Aesthetic (TP Orthodontics, La Porte, Ind), 0.014 in; and (4) Tooth Tone (Ortho Organizers, Calsbad, Calif) 0.016 in. Block randomization with block sizes of 4 and 8 was used to ensure an allocation ratio of 1:1:1:1. The primary outcome was alignment efficiency determined by the reduction in Little's irregularity index (mm). Secondary outcomes were color change using the Commission Internationale de L'Eclairage L*a*b* system and percentage of coating loss. Blinding was only applicable to outcome assessment of alignment efficiency. Regression models with Sidak's multiple comparison of means were used to analyze the data.

    RESULTS: One hundred fifty patients (300 dental arches) were allocated to the treatment interventions, including 61 male and 89 female subjects with a mean age of 16.60 years. The average duration of follow-up was 63.65 days. Baseline characteristics for the archwire groups were similar. One patient was lost to follow-up. Five percent (n = 15) of the archwires fractured: BioCosmetic, 5.3% (n = 4); Titanol, 6.8% (n = 5); TP Aesthetic, 5.3% (n = 4); and Tooth Tone, 2.7% (n = 2). We analyzed 283 dental arches for alignment efficiency. There was no statistically significant difference for mean reduction in irregularity between the archwire groups (P = 0.627): BioCosmetic (n = 71), 3.86 mm (95% CI, 3.31-4.41); Titanol (n = 69), 4.51 mm (95% CI, 4.00-5.02); TP Aesthetic (n = 71), 4.13 mm (95% CI, 3.49-4.78); and Tooth Tone (n = 72), 4.21 mm (95% CI, 3.89-4.46). There was a statistically significant difference between archwire groups for color change (P = 0.001) and percentage of coating loss (P = 0.001), with BioCosmetic performing best in both parameters.

    CONCLUSIONS: There was no difference between the archwires for alignment efficiency. BioCosmetic performed statistically significantly better than did the other groups for both color change and coating loss.

    REGISTRATION: This trial was registered with the East Midlands NHS Research Ethics Committee (12/EM/0190).

    PROTOCOL: The protocol was not published before trial commencement.

  2. Wan Hassan WN, Othman SA, Chan CS, Ahmad R, Ali SN, Abd Rohim A
    Am J Orthod Dentofacial Orthop, 2016 Nov;150(5):886-895.
    PMID: 27871715 DOI: 10.1016/j.ajodo.2016.04.021
    INTRODUCTION: In this study we aimed to compare measurements on plaster models using a digital caliper, and on 3-dimensional (3D) digital models, produced using a structured-light scanner, using 3D software.

    METHODS: Fifty digital models were scanned from the same plaster models. Arch and tooth size measurements were made by 2 operators, twice. Calibration was done on 10 sets of models and checked using the Pearson correlation coefficient. Data were analyzed by error variances, repeatability coefficient, repeated-measures analysis of variance, and Bland-Altman plots.

    RESULTS: Error variances ranged between 0.001 and 0.044 mm for the digital caliper method, and between 0.002 and 0.054 mm for the 3D software method. Repeated-measures analysis of variance showed small but statistically significant differences (P <0.05) between the repeated measurements in the arch and buccolingual planes (0.011 and 0.008 mm, respectively). There were no statistically significant differences between methods and between operators. Bland-Altman plots showed that the mean biases were close to zero, and the 95% limits of agreement were within ±0.50 mm. Repeatability coefficients for all measurements were similar.

    CONCLUSIONS: Measurements made on models scanned by the 3D structured-light scanner were in good agreement with those made on conventional plaster models and were, therefore, clinically acceptable.

  3. Ibrahim N, Asif MK, Sivarajan S, Teh NHK, Wey MC
    Am J Orthod Dentofacial Orthop, 2021 02;159(2):e83.
    PMID: 33546837 DOI: 10.1016/j.ajodo.2020.11.009
  4. Wey MC, Salah Fayed MM, Ringgingon LP, Sivarajan S
    Am J Orthod Dentofacial Orthop, 2020 08;158(2):159-160.
    PMID: 32576428 DOI: 10.1016/j.ajodo.2020.04.010
  5. Alyessary AS, Yap AUJ, Othman SA, Ibrahim N, Rahman MT, Radzi Z
    Am J Orthod Dentofacial Orthop, 2018 Aug;154(2):260-269.
    PMID: 30075928 DOI: 10.1016/j.ajodo.2017.11.031
    INTRODUCTION: In this study, we evaluated the effect of bone-borne accelerated expansion protocols on sutural separation and sutural bone modeling using a microcomputed tomography system. We also determined the optimum instant sutural expansion possible without disruption of bone modeling.

    METHODS: Sixteen New Zealand white rabbits, 20 to 24 weeks old, were randomly divided into 4 experimental groups. Modified hyrax expanders were placed across their interfrontal sutures and secured with miniscrew implants located bilaterally in the frontal bone. The hyrax appliances were activated as follows: group 1 (control), 0.5-mm per day expansion for 12 days; group 2, 1-mm instant expansion followed by 0.5 mm per day for 10 days; group 3, 2.5-mm instant expansion followed by 0.5 mm per day for 7 days, and group 4, 4-mm instant expansion followed by 0.5 mm per day for 4 days. After 6 weeks of retention, sutural separation and sutural bone modeling were assessed by microcomputed tomography and quantified. Statistical analysis was performed using Kruskal Wallis and Mann-Whitney U tests and the Spearman rho correlation (P <0.05).

    RESULTS: Median amounts of sutural separation ranged from 2.84 to 4.41 mm for groups 1 and 4, respectively. Median bone volume fraction ranged from 59.96% to 69.15% for groups 4 and 3, respectively. A significant correlation (r = 0.970; P <0.01) was observed between the amounts of instant expansion and sutural separation.

    CONCLUSIONS: Pending histologic verifications, our findings suggest that the protocol involving 2.5 mm of instant expansion followed by 0.5 mm per day for 7 days is optimal for accelerated sutural expansion. When 4 mm of instant expansion was used, the sutural bone volume fraction was decreased.

  6. Kamarudin Y, Skeats MK, Ireland AJ, Barbour ME
    Am J Orthod Dentofacial Orthop, 2020 Nov;158(5):e73-e82.
    PMID: 33008710 DOI: 10.1016/j.ajodo.2020.07.027
    INTRODUCTION: White spot lesions are a common side effect of orthodontic treatment. This laboratory study aimed to explore the suitability of chlorhexidine hexametaphosphate (CHX-HMP) as a coating for orthodontic elastomeric ligatures to provide sustained chlorhexidine (CHX) release.

    METHODS: Dissolution kinetics of CHX-HMP were firstly explored using spectroscopy and a colorimetric phosphate assay. Elastomeric ligatures were categorized into 3 groups-acetone-conditioned, ethanol-conditioned, and as received-and were then immersed in 5 mM CHX-HMP suspension or 5 mM chlorhexidine digluconate solution and rinsed. CHX release was measured over 8 weeks, and the effects of conditioning and immersion on elastomeric force and extension at rupture and surface topography were investigated.

    RESULTS: CHX-HMP exhibited a gradual equilibration that had not reached equilibrium within 8 weeks, releasing soluble CHX and a mixture of polyphosphate and orthophosphate. CHX digluconate-treated ligatures showed no CHX release, whereas CHX-HMP-treated ligatures showed varying degrees of release. As received, CHX-HMP-treated ligatures showed a modest release of CHX up to 7 days. Acetone conditioning did not enhance CHX-HMP uptake or subsequent CHX release and caused a deterioration in mechanical properties. Ethanol conditioning enhanced CHX-HMP uptake (6×) and led to a sustained CHX release over 8 weeks without affecting mechanical properties.

    CONCLUSIONS: Within the inherent limitations of this in-vitro study, CHX-HMP led to a sustained release of CHX from orthodontic elastomeric ligatures after ethanol conditioning. Conditioned and coated elastomeric ligatures may ultimately find application in the prevention of white spot lesions in orthodontic patients.

  7. Wan Hassan WN, Yusoff Y, Mardi NA
    Am J Orthod Dentofacial Orthop, 2017 Jan;151(1):209-218.
    PMID: 28024776 DOI: 10.1016/j.ajodo.2016.08.019
    INTRODUCTION: Rapid prototyping models can be reconstructed from stereolithographic digital study model data to produce hard-copy casts. In this study, we aimed to compare agreement and accuracy of measurements made with rapid prototyping and stone models for different degrees of crowding.

    METHODS: The Z Printer 450 (3D Systems, Rock Hill, SC) reprinted 10 sets of models for each category of crowding (mild, moderate, and severe) scanned using a structured-light scanner (Maestro 3D, AGE Solutions, Pisa, Italy). Stone and RP models were measured using digital calipers for tooth sizes in the mesiodistal, buccolingual, and crown height planes and for arch dimension measurements. Bland-Altman and paired t test analyses were used to assess agreement and accuracy. Clinical significance was set at ±0.50 mm.

    RESULTS: Bland-Altman analysis showed the mean bias of measurements between the models to be within ±0.15 mm (SD, ±0.40 mm), but the 95% limits of agreement exceeded the cutoff point of ±0.50 mm (lower range, -0.81 to -0.41 mm; upper range, 0.34 to 0.76 mm). Paired t tests showed statistically significant differences for all planes in all categories of crowding except for crown height in the moderate crowding group and arch dimensions in the mild and moderate crowding groups.

    CONCLUSIONS: The rapid prototyping models were not clinically comparable with conventional stone models regardless of the degree of crowding.

  8. Qamruddin I, Alam MK, Fida M, Khan AG
    Am J Orthod Dentofacial Orthop, 2016 Jan;149(1):62-6.
    PMID: 26718379 DOI: 10.1016/j.ajodo.2015.06.024
    The aim of this study was to see the effect of a single dose of low-level laser therapy on spontaneous and chewing pain after the placement of elastomeric separators.
  9. Shahrin AA, Ghani SHA, Norman NH
    Am J Orthod Dentofacial Orthop, 2021 Dec;160(6):784-792.
    PMID: 34452786 DOI: 10.1016/j.ajodo.2021.04.021
    INTRODUCTION: This trial aimed to investigate the effectiveness of microosteoperforations (MOPs) in overall time taken for alignment of maxillary anterior crowding and to evaluate the alignment improvement percentage within 6 months between MOPs and control groups.

    METHODS: Thirty adult participants (25 females and 5 males; mean age, 22.66 ± 3.27 years) with moderate upper labial segment crowding were randomly assigned into intervention and control groups using block randomization. All participants had first premolar extractions, bonded conventional fixed appliances, and 0.014-in, followed by 0.018-in nickel-titanium archwire placement for initial alignment. The intervention group received a 3-mm deep MOPs procedure under local anesthesia using a Propel device (Propel Ortho Singapore, Pte, Ltd, Winstedt Rd, Singapore) on the labial attached gingivae of maxillary incisors at monthly visits until complete alignment. Little's irregularity index was used to assess the overall changes and measure the change of tooth alignment of the 6 maxillary anterior teeth. Assessor blinding was employed.

    RESULTS: There was no statistically significant difference in the median overall alignment duration between MOPs and control groups (139 days [95% confidence interval, 115.32-161.83] vs 143 days [95% confidence interval, 107.12-179.74]; hazard ratio, 0.829; P = 0.467). The MOPs procedure had no significant effect on the alignment duration (P = 0.657) and no overall significant difference in alignment improvement percentage among 2 groups on the basis of time (F = 2.53; P = 0.124). No harm was encountered.

    CONCLUSIONS: The application of MOPs is no more effective in accelerating initial orthodontic alignment than conventional treatment.

    TRIAL REGISTRATION: This trial was registered at the ISRCTN registry with the study ID ISRCTN15080404.

    PROTOCOL: https://doi.org/10.1186/ISRCTN15080404.

    FUNDING: This work was supported by the Postgraduate Trust Fund, Faculty of Dentistry, Universiti Teknologi MARA.

  10. Qamruddin I, Alam MK, Mahroof V, Fida M, Khamis MF, Husein A
    Am J Orthod Dentofacial Orthop, 2017 Nov;152(5):622-630.
    PMID: 29103440 DOI: 10.1016/j.ajodo.2017.03.023
    INTRODUCTION: The aim of this study was to evaluate the effect of low-level laser irradiation applied at 3-week intervals on orthodontic tooth movement and pain associated with orthodontic tooth movement using self-ligating brackets.

    METHODS: Twenty-two patients (11 male, 11 female; mean age, 19.8 ± 3.1 years) with Angle Class II Division 1 malocclusion were recruited for this split-mouth clinical trial; they required extraction of maxillary first premolars bilaterally. After leveling and alignment with self-ligating brackets (SmartClip SL3; 3M Unitek, St Paul, Minn), a 150-g force was applied to retract the canines bilaterally using 6-mm nickel-titanium closed-coil springs on 0.019 x 0.025-in stainless steel archwires. A gallium-aluminum-arsenic diode laser (iLas; Biolase, Irvine, Calif) with a wavelength of 940 nm in a continuous mode (energy density, 7.5 J/cm2/point; diameter of optical fiber tip, 0.04 cm2) was applied at 5 points buccally and palatally around the canine roots on the experimental side; the other side was designated as the placebo. Laser irradiation was applied at baseline and then repeated after 3 weeks for 2 more consecutive follow-up visits. Questionnaires based on the numeric rating scale were given to the patients to record their pain intensity for 1 week. Impressions were made at each visit before the application of irradiation at baseline and the 3 visits. Models were scanned with a CAD/CAM scanner (Planmeca, Helsinki, Finland).

    RESULTS: Canine retraction was significantly greater (1.60 ± 0.38 mm) on the experimental side compared with the placebo side (0.79 ± 0.35 mm) (P <0.05). Pain was significantly less on the experimental side only on the first day after application of LLLI and at the second visit (1.4 ± 0.82 and 1.4 ± 0.64) compared with the placebo sides (2.2 ± 0.41 and 2.4 ± 1.53).

    CONCLUSIONS: Low-level laser irradiation applied at 3-week intervals can accelerate orthodontic tooth movement and reduce the pain associated with it.

  11. Alp S, Baka ZM
    Am J Orthod Dentofacial Orthop, 2018 Oct;154(4):517-523.
    PMID: 30268262 DOI: 10.1016/j.ajodo.2018.01.010
    INTRODUCTION: In this study, we aimed to determine the effect of regular probiotic consumption on microbial colonization in saliva in orthodontic patients and to comparatively evaluate the difference between the systemic consumption of probiotic products and the local application.

    METHODS: This study included 3 groups with 15 orthodontic patients in each. The control group included patients who had no probiotic treatment, the subjects in the kefir group consumed 2 × 100 ml of kefir (Atatürk Orman Ciftligi, Ankara, Turkey) per day, and the subjects in the toothpaste group brushed their teeth with toothpaste with probiotic content (GD toothpaste; Dental Asia Manufacturing, Shah Alam, Selangor, Malaysia) twice a day. Samples were collected at 3 times: beginning of the study, 3 weeks later, and 6 weeks later. The salivary flow rate, buffer capacity, and Streptococcus mutans and Lactobacillus levels in the saliva were evaluated. Chair-side kits were used to determine the S mutans and Lactobacillus levels.

    RESULTS: A statistically significant decrease was observed in the salivary S mutans and Lactobacillus levels in the kefir and toothpaste groups compared with the control group (P <0.05). A statistically significant increase was observed in the toothpaste group compared with the control and kefir groups in buffer capacity. Changes in the salivary flow rate were not statistically significant.

    CONCLUSIONS: The regular use of probiotics during fixed orthodontic treatment reduces the S mutans and Lactobacillus levels in the saliva.

  12. Mulimani PS
    Am J Orthod Dentofacial Orthop, 2017 Jul;152(1):1-8.
    PMID: 28651753 DOI: 10.1016/j.ajodo.2017.03.020
    Organized evidence-based practice is said to have started in the medical field in the late 20th century. Its principles and usage eventually spread to other health sciences, including orthodontics. Although the conceptual foundations and basic tenets of evidence-based orthodontics are based on the classical approach of testing medical interventions, differences unravel as we encounter the ground realities in orthodontics, which are unique due to the length, complexity, and diversity involved in orthodontic treatment and research. How has this led to the evolution of evidence-based orthodontics and changes in its applications? Is it being translated to better clinical answers, treatment strategies, patient satisfaction, and information for orthodontists? What more needs to be done, considering the rapidly changing orthodontic scenario? This article aims to explore these questions to evaluate how evidence-based orthodontics has played itself out so far, so that it can continue to grow strong and stand up to the challenges of 21st century orthodontics.
  13. Sia S, Shibazaki T, Koga Y, Yoshida N
    Am J Orthod Dentofacial Orthop, 2009 Jan;135(1):36-41.
    PMID: 19121498 DOI: 10.1016/j.ajodo.2007.01.034
    This study was designed to determine the optimum vertical height of the retraction force on the power arm that is required for efficient anterior tooth retraction during space closure with sliding mechanics.
  14. Tan SK, Leung WK, Tang ATH, Zwahlen RA
    Am J Orthod Dentofacial Orthop, 2022 Feb;161(2):e105-e113.
    PMID: 34531091 DOI: 10.1016/j.ajodo.2021.01.024
    INTRODUCTION: This study was conducted to investigate and compare esthetic perceptions of different facial profiles among Hong Kong Chinese laypersons and patients scheduled for orthognathic treatment.

    METHODS: Two sets of 3-dimensional facial photographs (1 male and 1 female) each comprised 7 images that showed different dentoskeletal relations (ie, Class I, bimaxillary protrusion, bimaxillary retrusion, maxillary protrusion, maxillary retrusion, mandibular protrusion, and mandibular retrusion). The sets of photographs were shown to 101 laypersons (age, 28.87 ± 6.22 years) and 60 patients seeking orthognathic treatment (age, 27.12 ± 6.07 years). They rated their esthetic perceptions of the photographs on the basis of a 100 mm visual analog scale (VAS) from 0 (very unattractive) to 100 (very attractive).

    RESULTS: The dentoskeletal Class I facial profile was ranked as the most attractive profile. Female orthognathic judges selected the retrusive maxilla while male orthognathic judges and male and female laypersons ranked the mandibular protrusion profile as the least attractive profile for both females and males. A bimaxillary protrusive female profile was viewed as more attractive by the orthognathic male (P = 0.006) and female (P = 0.006) judges, compared with female layperson judges. After adjustment for age, no statistically significant interaction between sex and judges (P >0.10) for all VAS scores were detected. For the female bimaxillary protrusive profile, orthognathic patient judges assigned a mean VAS score of 9.174 points higher than layperson judges (95% confidence interval, 3.11-15.24; P = 0.003).

    CONCLUSION: Dentoskeletal Class I facial profile was generally considered the most attractive profile in both sexes; male and female orthognathic patients preferred a bimaxillary protrusive female profile. A concave facial profile was perceived as least attractive in both sexes.

  15. Yahya M'F, Wang GM, Nimbalkar S
    Am J Orthod Dentofacial Orthop, 2023 Jul;164(1):97-105.
    PMID: 36890012 DOI: 10.1016/j.ajodo.2022.11.013
    INTRODUCTION: The evaluation of the quality of information (QOI) and clarity of information (COI) among oral health-related videos on the video-streaming Web site YouTube is scarce. This study evaluated QOI and COI regarding temporary anchorage devices contained within videos uploaded by dental professionals (DPs) on YouTube.

    METHODS: YouTube videos were systematically acquired with 4 search terms. The top 50 videos per search term by the number of views were stored in a YouTube account. A set of inclusion/exclusion criteria were applied, videos were assessed for viewing characteristics, a 4-point scoring system (0-3) was applied to evaluate QOI in 10 predetermined domains, and a 3-point scoring system (0-2) was applied to evaluate COI. Descriptive statistical analyses and intrarater and interrater reliability tests were performed.

    RESULTS: Strong intrarater and interrater reliability scores were observed. Sixty-three videos from the top 58 most-viewed DPs were viewed 1,395,471 times (range, 414-124,939). Most DPs originated from the United States (20%), and orthodontists (62%) uploaded most of the videos. The mean number of reported domains was 2.03 ± 2.40 (out of 10). The mean overall QOI score per domain was 0.36 ± 0.79 (out of 3). The "Placement of miniscrews" domain scored highest (1.23 ± 0.75). The "Cost of miniscrews placement" domain scored the lowest (0.03 ± 0.25). The mean overall QOI score per DP was 3.59 ± 5.64 (out of 30). The COI in 32 videos was immeasurable, and only 2 avoided using technical words.

    CONCLUSIONS: The QOI related to temporary anchorage devices contained within videos provided by DPs through the YouTube Web site is deficient, particularly in the cost of placement. Orthodontists should be aware of the importance of YouTube as an information resource and ensure that videos related to temporary anchorage devices contain comprehensive and evidence-based information.

  16. Asif MK, Ibrahim N, Sivarajan S, Heng Khiang Teh N, Chek Wey M
    Am J Orthod Dentofacial Orthop, 2020 Oct;158(4):579-586.e1.
    PMID: 32826123 DOI: 10.1016/j.ajodo.2019.09.022
    INTRODUCTION: The study aimed to investigate the effects of micro-osteoperforations (MOPs) on the mandibular bone volume/tissue volume (BV/TV) ratio changes and the rate of orthodontic tooth movement using cone-beam computed tomography images. Another objective was to evaluate the effects of MOP frequency intervals (4 weeks, 8 weeks, and 12 weeks) on the BV/TV ratio and rate of tooth movement.

    METHODS: In 24 participants, 140-200 g of force was applied for mandibular canine retraction. Three MOPs were made according to the scheduled intervals of the 3 different groups: group 1 (MOP 4 weeks), group 2 (MOP 8 weeks), and group 3 (MOP 12 weeks) directly at the mandibular buccal cortical bone of extracted first premolars sites. Cone-beam computed tomography scans were obtained at the 12th week after MOP application. Computed tomography Analyzer software (version 1.11.0.0; Skyscan, Kontich, Belgium) was used to compute the trabecular alveolar BV/TV ratio.

    RESULTS: A significant difference was observed in the rate of canine movement between control and MOP. Paired t test analysis showed a significant difference (P = 0.001) in the mean BV/TV ratio between control and MOP sides in all the frequency intervals groups. However, the difference was significant only in group 1 (P = 0.014). A strong negative correlation (r = -0.86) was observed between the rate of canine tooth movement and the BV/TV ratio at the MOP side for group 1 and all frequency intervals together (r = -0.42).

    CONCLUSIONS: The rate of orthodontic tooth movement can be accelerated by the MOP technique with frequently repeated MOPs throughout the treatment.