Displaying publications 1 - 20 of 30 in total

Abstract:
Sort:
  1. Qureshi MS, Yusoff AR, Wirzal MD, Sirajuddin, Barek J, Afridi HI, et al.
    Crit Rev Anal Chem, 2016;46(2):146-59.
    PMID: 25831046 DOI: 10.1080/10408347.2015.1004157
    Phthalates are endocrine disruptors frequently occurring in the general and industrial environment and in many industrial products. Moreover, they are also suspected of being carcinogenic, teratogenic, and mutagenic, and they show diverse toxicity profiles depending on their structures. The European Union and the United States Environmental Protection Agency (US EPA) have included many phthalates in the list of priority substances with potential endocrine-disrupting action. They are: dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP), butylbenzyl phthalate (BBP), diethylhexyl phthalate (DEHP), di-iso-nonyl phthalate (DINP), di-iso-decyl phthalate (DIDP), di-n-decyl phthalate (DnDP), and dioctyl phthalate (DOP). There is an ever-increasing demand for new analytical methods suitable for monitoring different phthalates in various environmental, biological, and other matrices. Separation and spectrometric methods are most frequently used. However, modern electroanalytical methods can also play a useful role in this field because of their high sensitivity, reasonable selectivity, easy automation, and miniaturization, and especially low investment and running costs, which makes them suitable for large-scale monitoring. Therefore, this review outlines possibilities and limitations of various analytical methods for determination of endocrine-disruptor phthalate esters in various matrices, including somewhat neglected electroanalytical methods.
  2. Lee PK, Woi PM
    Crit Rev Anal Chem, 2020;50(5):393-404.
    PMID: 31335176 DOI: 10.1080/10408347.2019.1642733
    Mixed valence transition metal hexacyanoferrates (MeHCF)-Prussian blue and its analogs receive enormous research interest in the electrochemical sensing field. In recent years, conducting materials such as conducting polymer, carbon nanomaterial, and noble metals have been used to form nanocomposites with MeHCF. The scope of this review offers the reasons behind the preparation of various MeHCF based nanocomposite toward electrochemical detection. We primarily focus on the current progress of the development of MEHCF-based nanocomposites. The synthesis methods for these nanocomposites are also reviewed and discussed.
  3. Tang LW, Alias Y, Zakaria R, Woi PM
    Crit Rev Anal Chem, 2023;53(4):869-886.
    PMID: 34672838 DOI: 10.1080/10408347.2021.1989657
    A detailed overview toward the advancement of amino acid-based electrochemical sensors on the detection of heavy metals is presented. Discussion is focused on the unique properties of various amino acids (AAs) and its composites which allow them being employed in a diverse range of sensing platforms. Formation of metal-ligand complexes in between metal ions and different AAs has been discussed. The essential insights on the interaction between amino acid-based sensors and target heavy metal ions (HMIs) are provided, along with the discussion on their pros and cons. Voltammetry analysis of metal ions based on various interfaces of electrochemical sensors has been highlighted, together with the incorporation of AAs with organic, inorganic and bio-materials. In all these cases, the amino acid modified electrodes have demonstrated large active surface area with abundant adsorption sites for HMIs. The developed sensors are promising for environmental applications, as evidenced by the high selectivity, high sensitivity, high catalytic activity, and low detection limits. The materials involved, fabrication techniques and its sensing mechanism were comprehensively discussed, and the future outlooks of electrochemical sensing platforms are emphasized in this review.
  4. Junaid HM, Batool M, Harun FW, Akhter MS, Shabbir N
    Crit Rev Anal Chem, 2020 Sep 08.
    PMID: 32897731 DOI: 10.1080/10408347.2020.1806703
    Spectacular color change during a chemical reaction is always fascinating. A variety of chemosensors including Schiff bases have been reported for selective as well as sensitive recognition of ions. This review explains the use of Schiff bases as color changing agents in the detection of anions. This magic of colors is attributed to change in the electronic structure of the system during reaction. Schiff base chemosensors are easy to synthesize, inexpensive and can be used for visual sensing of different ions. Development of Schiff base chemosensors is commonly based on the interactions between polar groups of Schiff bases and ionic species and the process of charge transfer, electron transfer and hydrogen bonding between Schiff bases and ionic species cause the color of the resultant to be changed. Therefore, designing of simple Schiff base chemosensors which are capable of selective sensing of different anions has attracted considerable interest. In particular, naked eye sensing through color change is important and useful since it allows sensing of ions through color changes without using any instrumental technique.HighlightsNaked eye sensors are of much interest these days due to their visual detection properties rather employing complex instrumentation.Optical sensors are sensitive, selective, cost effective and robust.The magic of color change is fascinating factor in detection by these sensors.The color change may be attributed by interaction between anion and Schiff base by different mechanism i.e. electron transfer, charge transfer, hydrogen bonding, ICT etc.LOD data is an evidence of their great efficiency.
  5. Rovina K, Siddiquee S, Shaarani SM
    Crit Rev Anal Chem, 2017 Jan 27.
    PMID: 28128965 DOI: 10.1080/10408347.2017.1287558
    Tartrazine is an azo food dye, orange-coloured and water soluble that usually used in foods, pharmaceuticals, cosmetics, and textiles. Tartrazine possess adverse health effect to human such as hyperactivity in children, allergy and asthma. Joint FAO/WHO Expert Committee on Food Additive (JECFA) and EU Scientific Committee for Food (SCF) standardized the acceptable daily intake (ADI) for Tartrazine is at 7.5 mg kg(-1) body weight. Many researchers have been detected the presence of Tartrazine for monitoring the quality and safety of food products. In this review paper highlighted various detection and extraction methods of Tartrazine. Some of the analytical methods are available such as high performance liquid chromatography (HPLC), electrochemical sensor, thin-layer chromatography (TLC), spectrophotometry, capillary electrophoresis and liquid chromatography-tandem mass spectrometry (LC-MS). As extraction steps are discussed: liquid-liquid extraction (LLE), solid-phase extraction (SPE), membrane filtration, cloud point extraction and other extraction method. Also, brief overview explained the synthesis process and metabolism of Tartrazine and the maximum permitted level in different countries. This review paper will give insight scenario on different extraction and analytical methods for determination of Tartrazine on healthy food among public attract attention on food safety and quality which can provide incalculable interest to food industry and government bodies.
  6. Tay KSJ, See HH
    Crit Rev Anal Chem, 2024 Jan 02.
    PMID: 38165816 DOI: 10.1080/10408347.2023.2299280
    Sample clean-up and pre-concentration are critical components of pharmaceutical analysis. The dispersive liquid-liquid microextraction (DLLME) technique is widely recognized as the most effective approach for enhancing overall detection sensitivity. While various DLLME modes have been advanced in pharmaceutical analysis, there need to be more discussions on pre-concentration techniques specifically developed for this field. This review presents a comprehensive overview of the different DLLME modes used in pharmaceutical analysis from 2017 to May 2023. The review covers the principles of DLLME, the factors affecting microextraction, the selected applications of different DLLME modes, and their advantages and disadvantages. Additionally, it focuses on multi-extraction strategies employed for pharmaceutical analysis.
  7. Ibrahim WA, Nodeh HR, Sanagi MM
    Crit Rev Anal Chem, 2016 Jul 03;46(4):267-83.
    PMID: 26186420 DOI: 10.1080/10408347.2015.1034354
    Graphene is a new carbon-based material that is of interest in separation science. Graphene has extraordinary properties including nano size, high surface area, thermal and chemical stability, and excellent adsorption affinity to pollutants. Its adsorption mechanisms are through non-covalent interactions (π-π stacking, electrostatic interactions, and H-bonding) for organic compounds and covalent interactions for metal ions. These properties have led to graphene-based material becoming a desirable adsorbent in a popular sample preparation technique known as solid phase extraction (SPE). Numerous studies have been published on graphene applications in recent years, but few review papers have focused on its applications in analytical chemistry. This article focuses on recent preconcentration of trace elements, organic compounds, and biological species using SPE-based graphene, graphene oxide, and their modified forms. Solid phase microextraction and micro SPE (µSPE) methods based on graphene are discussed.
  8. Wan Ibrahim WA, Nodeh HR, Aboul-Enein HY, Sanagi MM
    Crit Rev Anal Chem, 2015;45(3):270-87.
    PMID: 25849825 DOI: 10.1080/10408347.2014.938148
    Recently, a simple, rapid, high-efficiency, selective, and sensitive method for isolation, preconcentration, and enrichment of analytes has been developed. This new method of sample handling is based on ferum oxides as magnetic nanoparticles (MNPs) and has been used for magnetic solid-phase extraction (MSPE) of various analytes from various matrices. This review focuses on the applications of modified ferum oxides, especially modified Fe3O4 MNPs, as MSPE adsorbent for pesticide isolation from various matrices. Further perspectives on MSPE based on modified Fe3O4 for inorganic metal ions, organic compounds, and biological species from water samples are also presented. Ferum(III) oxide MNPs (Fe2O3) are also highlighted.
  9. Zainal PNS, Alang Ahmad SA, Abdul Aziz SFN, Rosly NZ
    Crit Rev Anal Chem, 2020 Nov 06.
    PMID: 33155481 DOI: 10.1080/10408347.2020.1839736
    The past several decades have seen increasing concern regarding the wide distribution of polycyclic aromatic hydrocarbons (PAHs) in environmental matrices. Primary toxicological data show PAHs' persistent characteristics and possible toxicity effects. Because of this pressing global issue, electroanalytical methods have been introduced. These methods are effective for PAH determination in environmental waters, even outclassing sophisticated analytical techniques such as chromatography, conventional spectrophotometry, fluorescence, and capillary electrophoresis. Herein, the literature published on PAHs is reviewed and discussed with special regard to PAH occurrence. Moreover, the recent developments in electrochemical sensors for PAH determination and the challenges and future outlooks in this field, are also presented.
  10. Murugasenapathi NK, Ghosh R, Ramanathan S, Ghosh S, Chinnappan A, Mohamed SAJ, et al.
    Crit Rev Anal Chem, 2023;53(5):1044-1065.
    PMID: 34788167 DOI: 10.1080/10408347.2021.2002133
    Transistor-based sensors have been widely recognized to be highly sensitive and reliable for point-of-care/bed-side diagnosis. In this line, a range of cutting-edge technologies has been generated to elevate the role of transistors for biomolecule detection. Detection of a wide range of clinical biomarkers has been reported using various configurations of transistors. The inordinate sensitivity of transistors to the field-effect imparts high sensitivity toward wide range of biomolecules. This overview has gleaned the present achievements with the technological advancements using high performance transistor-based sensors. This review encloses transistors incorporated with a variety of functional nanomaterials and organic elements for their excellence in selectivity and sensitivity. In addition, the technological advancements in fabrication of these microdevices or nanodevices and functionalization of the sensing elements have also been discussed. The technological gap in the realization of sensors in transistor platforms and the resulted scope for research has been discussed. Finally, foreseen technological advancements and future research perspectives are described.
  11. Hui BY, Raoov M, Zain NNM, Mohamad S, Osman H
    Crit Rev Anal Chem, 2017 Sep 03;47(5):454-467.
    PMID: 28453309 DOI: 10.1080/10408347.2017.1320936
    The growth in driving force and popularity of cyclodextrin (CDs) and ionic liquids (ILs) as promising materials in the field of analytical chemistry has resulted in an exponentially increase of their exploitation and production in analytical chemistry field. CDs belong to the family of cyclic oligosaccharides composing of α-(1,4) linked glucopyranose subunits and possess a cage-like supramolecular structure. This structure enables chemical reactions to proceed between interacting ions, radical or molecules in the absence of covalent bonds. Conversely, ILs are an ionic fluids comprising of only cation and anion often with immeasurable vapor pressure making them as green or designer solvent. The cooperative effect between CD and IL due to their fascinating properties, have nowadays contributed their footprints for a better development in analytical chemistry nowadays. This comprehensive review serves to give an overview on some of the recent studies and provides an analytical trend for the application of CDs with the combination of ILs that possess beneficial and remarkable effects in analytical chemistry including their use in various sample preparation techniques such as solid phase extraction, magnetic solid phase extraction, cloud point extraction, microextraction, and separation techniques which includes gas chromatography, high-performance liquid chromatography, capillary electrophoresis as well as applications of electrochemical sensors as electrode modifiers with references to recent applications. This review will highlight the nature of interactions and synergic effects between CDs, ILs, and analytes. It is hoped that this review will stimulate further research in analytical chemistry.
  12. Ahmad M, Ahmad A, Omar TFT, Mohammad R
    Crit Rev Anal Chem, 2023 Apr 13.
    PMID: 37052389 DOI: 10.1080/10408347.2023.2199432
    Increasing acidity of seawater caused by increasing anthropogenic carbon dioxide absorbed into the seawater attracted the interest of researchers due to increased concern on the deterioration of marine systems and food supply to humans. Total alkalinity (TA) is one of the important parameters in determining carbonate chemistry and is described as the capacity of the sample to neutralize acids. Over the last two decades, many analytical techniques have been developed to determine TA. This article presents a review of different analytical techniques including titration, colorimetric, spectrophotometric, and potentiometric analyses in measuring TA. Among these analytical techniques, potentiometry analysis, which utilizes electrode systems such as glass electrode and ion-selective electrode used as indicator electrodes, is the most used technique. Important features such as principle, limitations, and challenges of the involved technique are discussed in detail.
  13. Subramani IG, Perumal V, Gopinath SCB, Fhan KS, Mohamed NM
    Crit Rev Anal Chem, 2021 Mar 11.
    PMID: 33691533 DOI: 10.1080/10408347.2021.1889962
    Over the past decade, science has experienced a growing rise in nanotechnology with ground-breaking contributions. Through various laborious technologies, nanomaterials with different architectures from 0 D to 3 D have been synthesized. However, the 3 D flower-like organic-inorganic hybrid nanomaterial with the most direct one-pot green synthesis method has attracted widespread attention and instantly become research hotspot since its first allusion in 2012. Mild synthesis procedure, high surface-to-volume ratio, enhanced enzymatic activity and stability are the main factor for its rapid development. However, its lower mechanical strength, difficulties in recovery from the reaction system, lower loading capacity, poor reusability and accessibility of enzymes are fatal, which hinders its wide application in industry. This review first discusses the selection of non-enzymatic biomolecules for the synthesis of hybrid nanoflowers followed by the innovative advancements made in organic-inorganic hybrid nanoflowers to overcome aforementioned issues and to enhance their extensive downstream applications in transduction technologies. Besides, the role of hybrid nanoflower has been successfully utilized in many fields including, water remediation, biocatalyst, pollutant adsorption and decolourization, nanoreactor, biosensing, cellular uptake and others, accompanied with several quantification technologies, such as ELISA, electrochemical, surface plasmon resonance (SPR), colorimetric, and fluorescence were comprehensively reviewed.
  14. Aun TT, Salleh NM, Ali UFM, Manan NSA
    Crit Rev Anal Chem, 2021 Sep 03.
    PMID: 34477020
    Non-enzymatic glucose sensors based on the use of copper and its oxides have emerged as promising candidates to replace enzymatic glucose sensors owing to their stability, ease of fabrication, and superior sensitivity. This review explains the theories of the mechanism of glucose oxidation on copper transition metal electrodes. It also presents an overview on the development of among the best non-enzymatic copper-based glucose sensors in the past 10 years. A brief description of methods, interesting findings, and important performance parameters are provided to inspire the reader and researcher to create new improvements in sensor design. Finally, several important considerations that pertain to the nano-structuring of the electrode surface is provided.
  15. Meskher H, Ragdi T, Thakur AK, Ha S, Khelfaoui I, Sathyamurthy R, et al.
    Crit Rev Anal Chem, 2023 Feb 01.
    PMID: 36724894 DOI: 10.1080/10408347.2023.2171277
    Carbon nanotubes (CNTs), are safe, biocompatible, bioactive, and biodegradable materials, and have sparked a lot of attention due to their unique characteristics in a variety of applications, including medical and dye industries, paper manufacturing and water purification. CNTs also have a strong film-forming potential, permitting them to be widely employed in constructing sensors and biosensors. This review concentrates on the application of CNT-based nanocomposites in the production of electrochemical sensors and biosensors. It emphasizes the synthesis and optimization of CNT-based sensors for a range of applications and outlines the benefits of using CNTs for biomolecule immobilization. In addition, the use of molecularly imprinted polymer (MIP)-CNTs in the production of electrochemical sensors is also discussed. The challenges faced by the current CNTs-based sensors, along with some the future perspectives and their future opportunities, are also briefly explained in this paper.
  16. Muniandy S, Teh SJ, Thong KL, Thiha A, Dinshaw IJ, Lai CW, et al.
    Crit Rev Anal Chem, 2019;49(6):510-533.
    PMID: 30648398 DOI: 10.1080/10408347.2018.1561243
    The development of easy to use, rapid and sensitive methods for direct detection of foodborne bacterial pathogens has become significantly important due to their impact on human health. In recent years, carbon nanomaterials have been adapted in the fabrication of electrochemical biosensors due to their exceptional combination of intrinsic properties such as high conductivity, stability and biocompatibility that render them as a promising candidate for bio-sensing material. The scope of this review is to provide a brief history of the current methods and different types of electrochemical biosensors used for the detection of bacterial pathogens. We primarily focus on the recent progress and applications of graphene, carbon nanotubes and their derivatives in electrochemical biosensors for foodborne bacterial pathogens detection. Finally, the status and future prospects of carbon-based electrochemical biosensors are also reviewed and discussed.
  17. Mohd Rosdi NANB, Abd Hamid N, Mohd Ali SF, Sino H, Lee LC
    Crit Rev Anal Chem, 2023 Sep 06.
    PMID: 37672265 DOI: 10.1080/10408347.2023.2253473
    Soil is one type of Earth material demonstrating a wide range of physical, chemical, and biological properties. As the compositional profile of soil is a product of interaction between numerous abiotic and biotic components, it tends to be unique by its geographic origin. Hence, soil is paramount for predicting source or origin in forensic provenance and intelligence, food provenance, biosecurity, and archaeology. In the context of forensic investigation, source tracing of soil could be executed by a comparison or provenance analysis. Soil compositional fingerprints acquired using analytical methods must be carefully interpreted via suitable mathematical and statistical tools since multiple sources can contribute to the variability of soil other than its provenance. This article reviews recent trends in soil sampling and data interpretation strategies proposed for source tracing of soil evidence. Performances of soil provenance indicators are also described. Then, perspectives on possible research directions guiding forensic soil provenance are proposed. This timely critical review reveals the essential idea and gap in forensic soil provenance for stimulating the development of more efficient and effective provenance strategies.
  18. Vasudevan M, Perumal V, Karuppanan S, Ovinis M, Bothi Raja P, Gopinath SCB, et al.
    Crit Rev Anal Chem, 2022 Oct 26.
    PMID: 36288094 DOI: 10.1080/10408347.2022.2135090
    Biopolymers are an attractive green alternative to conventional polymers, owing to their excellent biocompatibility and biodegradability. However, their amorphous and nonconductive nature limits their potential as active biosensor material/substrate. To enhance their bio-analytical performance, biopolymers are combined with conductive materials to improve their physical and chemical characteristics. We review the main advances in the field of electrochemical biosensors, specifically the structure, approach, and application of biopolymers, as well as their conjugation with conductive nanoparticles, polymers and metal oxides in green-based noninvasive analytical biosensors. In addition, we reviewed signal measurement, substrate bio-functionality, biochemical reaction, sensitivity, and limit of detection (LOD) of different biopolymers on various transducers. To date, pectin biopolymer, when conjugated with either gold nanoparticles, polypyrrole, reduced graphene oxide, or multiwall carbon nanotubes forming nanocomposites on glass carbon electrode transducer, tends to give the best LOD, highest sensitivity and can detect multiple analytes/targets. This review will spur new possibilities for the use of biosensors for medical diagnostic tests.
  19. Letchumanan I, Gopinath SCB, Md Arshad MK, Mohamed Saheed MS, Perumal V, Voon CH, et al.
    Crit Rev Anal Chem, 2020 Sep 08.
    PMID: 32897761 DOI: 10.1080/10408347.2020.1812373
    Mortality level is worsening the situation worldwide thru blood diseases and greatly jeopardizes the human health with poor diagnostics. Due to the lack of successful generation of early diagnosis, the survival rate is currently lower. To overcome the present hurdle, new diagnostic methods have been choreographed for blood disease biomarkers analyses with the conjunction of ultra-small ideal gold nanohybrids. Gold-hybrids hold varieties of unique features, such as high biocompatibility, increased surface-to-volume ratio, less-toxicity, ease in electron transfer and have a greater localized surface plasmon resonance. Gold-nanocomposites can be physically hybrid on the sensor surface and functionalize with the biomolecules using appropriate chemical conjugations. Revolutionizing biosensor platform can be prominently linked for the nanocomposite applications in the current research on medical diagnosis. This review encloses the new developments in diagnosing blood biomarkers by utilizing the gold-nanohybrids. Further, the current state-of-the-art and the future envision with digital monitoring for facile telediagnosis were narrated.
  20. Adam T, Dhahi TS, Gopinath SCB, Hashim U
    Crit Rev Anal Chem, 2022;52(8):1913-1929.
    PMID: 34254863 DOI: 10.1080/10408347.2021.1925523
    Nanowires have been utilized widely in the generation of high-performance nanosensors. Laser ablation, chemical vapor, thermal evaporation and alternating current electrodeposition are in use in developing nanowires. Nanowires are in a great attention because of their submicron feature and their potentials in the front of nanoelectronics, accelerated field effect transistors, chemical- and bio-sensors, and low power consuming light-emitting devices. With the control of nanowire size and concentration of dopant, the electrical sensitivity and other properties of nanowires can be tuned for the reproducibility. Nanowires comprise of arrays of electrodes that form a nanometer electrical circuit. One of advantages of nanowires is that they can be fabricated in nanometer-size for various applications in different approaches. Several studies have been conducted on nanowires and researchers discovered that nanowires have the potential in the applications with material properties at the nanometer scale. The unique electrical properties of nanowires have made them to be promising for numerous applications. Nowadays, for example, MOS field-effect transistors are largely used as fundamental building elements in electronic circuits. Also, the dimension of MOS transistors is gradually decreasing to the nanoscale based on the prediction made by Moor's law. However, their fabrication is challenging. This review summarized different techniques in the fabrication of nanowires, global nanowire prospect, testing of nanowires to understand the real electrical behavior using higher resolution microscopes, and brief applications in the detection of biomolecules, disease such as corona viral pandemic, heavy metal in water, and applications of nanowires in agriculture.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links