Displaying publications 1 - 20 of 92 in total

Abstract:
Sort:
  1. Abidi SS
    J Med Syst, 2001 Jun;25(3):147-65.
    PMID: 11433545
    Worldwide healthcare delivery trends are undergoing a subtle paradigm shift--patient centered services as opposed to provider centered services and wellness maintenance as opposed to illness management. In this paper we present a Tele-Healthcare project TIDE--Tele-Healthcare Information and Diagnostic Environment. TIDE manifests an 'intelligent' healthcare environment that aims to ensure lifelong coverage of person-specific health maintenance decision-support services--i.e., both wellness maintenance and illness management services--ubiquitously available via the Internet/WWW. Taking on an all-encompassing health maintenance role--spanning from wellness to illness issues--the functionality of TIDE involves the generation and delivery of (a) Personalized, Pro-active, Persistent, Perpetual, and Present wellness maintenance services, and (b) remote diagnostic services for managing noncritical illnesses. Technically, TIDE is an amalgamation of diverse computer technologies--Artificial Intelligence, Internet, Multimedia, Databases, and Medical Informatics--to implement a sophisticated healthcare delivery infostructure.
  2. Srinivasan V, Eswaran C, Sriraam N
    J Med Syst, 2005 Dec;29(6):647-60.
    PMID: 16235818
    Electroencephalogram (EEG) signal plays an important role in the diagnosis of epilepsy. The long-term EEG recordings of an epileptic patient obtained from the ambulatory recording systems contain a large volume of EEG data. Detection of the epileptic activity requires a time consuming analysis of the entire length of the EEG data by an expert. The traditional methods of analysis being tedious, many automated diagnostic systems for epilepsy have emerged in recent years. This paper discusses an automated diagnostic method for epileptic detection using a special type of recurrent neural network known as Elman network. The experiments are carried out by using time-domain as well as frequency-domain features of the EEG signal. Experimental results show that Elman network yields epileptic detection accuracy rates as high as 99.6% with a single input feature which is better than the results obtained by using other types of neural networks with two and more input features.
  3. Logeswaran R, Eswaran C
    J Med Syst, 2006 Apr;30(2):133-8.
    PMID: 16705998
    Many medical examinations involve acquisition of a large series of slice images for 3D reconstruction of the organ of interest. With the paperless hospital concept and telemedicine, there is very heavy utilization of limited electronic storage and transmission bandwidth. This paper proposes model-based compression to reduce the load on such resources, as well as aid diagnosis through the 3D reconstruction of the structures of interest, for images acquired by various modalities, such as MRI, Ultrasound, CT, PET etc. and stored in the DICOM file format. An example implementation for the biliary track in MRCP images is illustrated in the paper. Significant compression gains may be derived from the proposed method, and a suitable mixture of the models and raw images would enhance the patient medical history archives as the models may be stored in the DICOM file format used in most medical archiving systems.
  4. Choong MK, Logeswaran R, Bister M
    J Med Syst, 2006 Jun;30(3):139-43.
    PMID: 16848126
    This paper attempts to improve the diagnostic quality of magnetic resonance (MR) images through application of lossy compression as a noise-reducing filter. The amount of imaging noise present in MR images is compared with the amount of noise introduced by the compression, with particular attention given to the situation where the compression noise is a fraction of the imaging noise. A popular wavelet-based algorithm with good performance, Set Partitioning in Hierarchical Trees (SPIHT), was employed for the lossy compression. Tests were conducted with a number of MR patient images and corresponding phantom images. Different plausible ratios between imaging noise and compression noise (ICR) were considered, and the achievable compression gain through the controlled lossy compression was evaluated. Preliminary results show that at certain ICR's, it becomes virtually impossible to distinguish between the original and compressed-decompressed image. Radiologists presented with a blind test, in certain cases, showed preference to the compressed image rather than the original uncompressed ones, indicating that under controlled circumstances, lossy image compression can be used to improve the diagnostic quality of the MR images.
  5. Logeswaran R, Eswaran C
    J Med Syst, 2006 Aug;30(4):317-24.
    PMID: 16978012
    Tumors are generally difficult to detect in Magnetic Resonance (MR) images as they can be of varying intensities and do not appear as clear structures on these images. This difficulty is more prominent in MR Cholangiopancreatography (MRCP), which is the MR technology using a special sequence of T2-weighted imaging to identify the biliary tract, pancreatic duct, and gallbladder in the liver region, as MRCP images are more noisy in nature and are acquired for a more focused area with too much flexibility in position orientation for convenient computer-aided diagnosis. Based on the principle that the tumor mass manifests itself as blockage of the biliary tree structure, this paper introduces a technique that uses a region growing algorithm to identify discontinuities in the biliary tree as a means to preliminary detection of a possible tumor, in a fashion similar to the visual observation used by most radiologists in making their preliminary diagnosis. Through the use of appropriate image normalization, watershed segmentation, thresholding, rule-based region growing, and region analysis, the proposed technique is shown in this paper to be successful in identifying MRCP images with liver carcinoma from those with normal liver. Acquisition standardization, interactive image selection, and optimum image orientation will further enhance the accuracy of this proposed scheme for use in aiding clinical diagnosis at medical institutions.
  6. Sriraam N, Eswaran C
    J Med Syst, 2006 Dec;30(6):439-48.
    PMID: 17233156
    Two-stage lossless data compression methods involving predictors and encoders are well known. This paper discusses the application of context based error modeling techniques for neural network predictors used for the compression of EEG signals. Error modeling improves the performance of a compression algorithm by removing the statistical redundancy that exists among the error signals after the prediction stage. In this paper experiments are carried out by using human EEG signals recorded under various physiological conditions to evaluate the effect of context based error modeling in the EEG compression. It is found that the compression efficiency of the neural network based predictive techniques is significantly improved by using the error modeling schemes. It is shown that the bits per sample required for EEG compression with error modeling and entropy coding lie in the range of 2.92 to 6.62 which indicates a saving of 0.3 to 0.7 bits compared to the compression scheme without error modeling.
  7. Shyamsunder R, Eswaran C, Sriraam N
    J Med Syst, 2007 Apr;31(2):109-16.
    PMID: 17489503
    The volume of patient monitoring video acquired in hospitals is very huge and hence there is a need for better compression of the same for effective storage and transmission. This paper presents a new motion segmentation technique, which improves the compression of patient monitoring video. The proposed motion segmentation technique makes use of a binary mask, which is obtained by thresholding the standard deviation values of the pixels along the temporal axis. Two compression methods, which make use of the proposed motion segmentation technique, are presented. The first method uses MPEG-4 coder and 9/7-biorthogonal wavelet for compressing the moving and stationary portions of the video respectively. The second method uses 5/3-biorthogonal wavelet for compressing both the moving and the stationary portions of the video. The performances of these compression algorithms are evaluated in terms of PSNR and bitrate. From the experimental results, it is found that the proposed motion technique improves the performance of the MPEG-4 coder. Among the two compression methods presented, the MPEG-4 based method performs better for bitrates less than 767 Kbps whereas for bitrates above 767 Kbps the performance of the wavelet based method is found superior.
  8. Basu K, Sriraam N, Richard RJ
    J Med Syst, 2007 Aug;31(4):247-53.
    PMID: 17685148
    For a given DNA sequence, it is well known that pair wise alignment schemes are used to determine the similarity with the DNA sequences available in the databanks. The efficiency of the alignment decides the type of amino acids and its corresponding proteins. In order to evaluate the given DNA sequence for its proteomic identity, a pattern matching approach is proposed in this paper. A block based semi-global alignment scheme is introduced to determine the similarity between the DNA sequences (known and given). The two DNA sequences are divided into blocks of equal length and alignment is performed which minimizes the computational complexity. The efficiency of the alignment scheme is evaluated using the parameter, percentage of similarity (POS). Four essential DNA version of the amino acids that emphasize the importance of proteomic functionalities are chosen as patterns and matching is performed with the known and given DNA sequences to determine the similarity between them. The ratio of amino acid counts between the two sequences is estimated and the results are compared with that of the POS value. It is found from the experimental results that higher the POS value and the pattern matching higher are the similarity between the two DNA sequences. The optimal block is also identified based on the POS value and amino acids count.
  9. Lalitha V, Eswaran C
    J Med Syst, 2007 Dec;31(6):445-52.
    PMID: 18041276
    Monitoring the depth of anesthesia (DOA) during surgery is very important in order to avoid patients' interoperative awareness. Since the traditional methods of assessing DOA which involve monitoring the heart rate, pupil size, sweating etc, may vary from patient to patient depending on the type of surgery and the type of drug administered, modern methods based on electroencephalogram (EEG) are preferred. EEG being a nonlinear signal, it is appropriate to use nonlinear chaotic parameters to identify the anesthetic depth levels. This paper discusses an automated detection method of anesthetic depth levels based on EEG recordings using non-linear chaotic features and neural network classifiers. Three nonlinear parameters, namely, correlation dimension (CD), Lyapunov exponent (LE) and Hurst exponent (HE) are used as features and two neural network models, namely, multi-layer perceptron network (feed forward model) and Elman network (feedback model) are used for classification. The neural network models are trained and tested with single and multiple features derived from chaotic parameters and the performances are evaluated in terms of sensitivity, specificity and overall accuracy. It is found from the experimental results that the Lyapunov exponent feature with Elman network yields an overall accuracy of 99% in detecting the anesthetic depth levels.
  10. Reza AW, Eswaran C, Hati S
    J Med Syst, 2008 Apr;32(2):147-55.
    PMID: 18461818
    Blood vessel detection in retinal images is a fundamental step for feature extraction and interpretation of image content. This paper proposes a novel computational paradigm for detection of blood vessels in fundus images based on RGB components and quadtree decomposition. The proposed algorithm employs median filtering, quadtree decomposition, post filtration of detected edges, and morphological reconstruction on retinal images. The application of preprocessing algorithm helps in enhancing the image to make it better fit for the subsequent analysis and it is a vital phase before decomposing the image. Quadtree decomposition provides information on the different types of blocks and intensities of the pixels within the blocks. The post filtration and morphological reconstruction assist in filling the edges of the blood vessels and removing the false alarms and unwanted objects from the background, while restoring the original shape of the connected vessels. The proposed method which makes use of the three color components (RGB) is tested on various images of publicly available database. The results are compared with those obtained by other known methods as well as with the results obtained by using the proposed method with the green color component only. It is shown that the proposed method can yield true positive fraction values as high as 0.77, which are comparable to or somewhat higher than the results obtained by other known methods. It is also shown that the effect of noise can be reduced if the proposed method is implemented using only the green color component.
  11. Rajasvaran L, Haw TW, Sarker SZ
    J Med Syst, 2008 Aug;32(4):259-68.
    PMID: 18619090
    This work presents a method for liver isolation in magnetic resonance imaging (MRI) abdomen images. It is based on a priori statistical information about the shape of the liver obtained from a training set using the segmentation approach. Morphological watershed algorithm is used as a key technique as it is a simple and intuitive method, producing a complete division of the image in separated regions even if the contrast is poor, and it is fast, with possibility for parallel implementation. To overcome the over-segmentation problem of the watershed process, image preprocessing and postprocessing are applied. Morphological smoothing, Gaussian smoothing, intensity thresholding, gradient computation and gradient thresholding are proposed for preprocessing with morphological and graph based region adjacent list constructed for region merging. A new integrated region similarity function is also defined for region merging control. The proposed method produces good isolation of liver in axial MRI images of the abdomen, as is shown in this paper.
  12. Logeswaran R, Chen LC
    J Med Syst, 2008 Dec;32(6):453-61.
    PMID: 19058649
    Service architectures are necessary for providing value-added services in telecommunications networks, including those in medical institutions. Separation of service logic and control from the actual call switching is the main idea of these service architectures, examples include Intelligent Network (IN), Telecommunications Information Network Architectures (TINA), and Open Service Access (OSA). In the Distributed Service Architectures (DSA), instances of the same object type can be placed on different physical nodes. Hence, the network performance can be enhanced by introducing load balancing algorithms to efficiently distribute the traffic between object instances, such that the overall throughput and network performance can be optimised. In this paper, we propose a new load balancing algorithm called "Node Status Algorithm" for DSA infrastructure applicable to electronic-based medical institutions. The simulation results illustrate that this proposed algorithm is able to outperform the benchmark load balancing algorithms-Random Algorithm and Shortest Queue Algorithm, especially under medium and heavily loaded network conditions, which are typical of the increasing bandwidth utilization and processing requirements at paperless hospitals and in the telemedicine environment.
  13. Reza AW, Eswaran C, Hati S
    J Med Syst, 2009 Feb;33(1):73-80.
    PMID: 19238899
    The detection of bright objects such as optic disc (OD) and exudates in color fundus images is an important step in the diagnosis of eye diseases such as diabetic retinopathy and glaucoma. In this paper, a novel approach to automatically segment the OD and exudates is proposed. The proposed algorithm makes use of the green component of the image and preprocessing steps such as average filtering, contrast adjustment, and thresholding. The other processing techniques used are morphological opening, extended maxima operator, minima imposition, and watershed transformation. The proposed algorithm is evaluated using the test images of STARE and DRIVE databases with fixed and variable thresholds. The images drawn by human expert are taken as the reference images. The proposed method yields sensitivity values as high as 96.7%, which are better than the results reported in the literature.
  14. Mueen A, Zainuddin R, Baba MS
    J Med Syst, 2010 Oct;34(5):859-64.
    PMID: 20703623 DOI: 10.1007/s10916-009-9300-y
    The next generation of medical information system will integrate multimedia data to assist physicians in clinical decision-making, diagnoses, teaching, and research. This paper describes MIARS (Medical Image Annotation and Retrieval System). MIARS not only provides automatic annotation, but also supports text based as well as image based retrieval strategies, which play important roles in medical training, research, and diagnostics. The system utilizes three trained classifiers, which are trained using training images. The goal of these classifiers is to provide multi-level automatic annotation. Another main purpose of the MIARS system is to study image semantic retrieval strategy by which images can be retrieved according to different levels of annotation.
  15. Reza AW, Eswaran C
    J Med Syst, 2011 Feb;35(1):17-24.
    PMID: 20703589 DOI: 10.1007/s10916-009-9337-y
    The increasing number of diabetic retinopathy (DR) cases world wide demands the development of an automated decision support system for quick and cost-effective screening of DR. We present an automatic screening system for detecting the early stage of DR, which is known as non-proliferative diabetic retinopathy (NPDR). The proposed system involves processing of fundus images for extraction of abnormal signs, such as hard exudates, cotton wool spots, and large plaque of hard exudates. A rule based classifier is used for classifying the DR into two classes, namely, normal and abnormal. The abnormal NPDR is further classified into three levels, namely, mild, moderate, and severe. To evaluate the performance of the proposed decision support framework, the algorithms have been tested on the images of STARE database. The results obtained from this study show that the proposed system can detect the bright lesions with an average accuracy of about 97%. The study further shows promising results in classifying the bright lesions correctly according to NPDR severity levels.
  16. Sim KS, Lai MA, Tso CP, Teo CC
    J Med Syst, 2011 Feb;35(1):39-48.
    PMID: 20703587 DOI: 10.1007/s10916-009-9339-9
    A novel technique to quantify the signal-to-noise ratio (SNR) of magnetic resonance images is developed. The image SNR is quantified by estimating the amplitude of the signal spectrum using the autocorrelation function of just one single magnetic resonance image. To test the performance of the quantification, SNR measurement data are fitted to theoretically expected curves. It is shown that the technique can be implemented in a highly efficient way for the magnetic resonance imaging system.
  17. Tan CC, Eswaran C
    J Med Syst, 2011 Feb;35(1):49-58.
    PMID: 20703586 DOI: 10.1007/s10916-009-9340-3
    This paper presents the results obtained for medical image compression using autoencoder neural networks. Since mammograms (medical images) are usually of big sizes, training of autoencoders becomes extremely tedious and difficult if the whole image is used for training. We show in this paper that the autoencoders can be trained successfully by using image patches instead of the whole image. The compression performances of different types of autoencoders are compared based on two parameters, namely mean square error and structural similarity index. It is found from the experimental results that the autoencoder which does not use Restricted Boltzmann Machine pre-training yields better results than those which use this pre-training method.
  18. Seng WC, Mirisaee SH
    J Med Syst, 2011 Aug;35(4):571-8.
    PMID: 20703533 DOI: 10.1007/s10916-009-9393-3
    Content-based image retrieval techniques have been extensively studied for the past few years. With the growth of digital medical image databases, the demand for content-based analysis and retrieval tools has been increasing remarkably. Blood cell image is a key diagnostic tool for hematologists. An automated system that can retrieved relevant blood cell images correctly and efficiently would save the effort and time of hematologists. The purpose of this work is to develop such a content-based image retrieval system. Global color histogram and wavelet-based methods are used in the prototype. The system allows users to search by providing a query image and select one of four implemented methods. The obtained results demonstrate the proposed extended query refinement has the potential to capture a user's high level query and perception subjectivity by dynamically giving better query combinations. Color-based methods performed better than wavelet-based methods with regard to precision, recall rate and retrieval time. Shape and density of blood cells are suggested as measurements for future improvement. The system developed is useful for undergraduate education.
  19. Reza AW, Eswaran C, Dimyati K
    J Med Syst, 2011 Dec;35(6):1491-501.
    PMID: 20703768 DOI: 10.1007/s10916-009-9426-y
    Due to increasing number of diabetic retinopathy cases, ophthalmologists are experiencing serious problem to automatically extract the features from the retinal images. Optic disc (OD), exudates, and cotton wool spots are the main features of fundus images which are used for diagnosing eye diseases, such as diabetic retinopathy and glaucoma. In this paper, a new algorithm for the extraction of these bright objects from fundus images based on marker-controlled watershed segmentation is presented. The proposed algorithm makes use of average filtering and contrast adjustment as preprocessing steps. The concept of the markers is used to modify the gradient before the watershed transformation is applied. The performance of the proposed algorithm is evaluated using the test images of STARE and DRIVE databases. It is shown that the proposed method can yield an average sensitivity value of about 95%, which is comparable to those obtained by the known methods.
  20. Purwanto, Eswaran C, Logeswaran R, Abdul Rahman AR
    J Med Syst, 2012 Apr;36(2):521-31.
    PMID: 22675726
    Cardiovascular disease (CVD) is the major cause of death globally. More people die of CVDs each year than from any other disease. Over 80% of CVD deaths occur in low and middle income countries and occur almost equally in male and female. In this paper, different computational models based on Bayesian Networks, Multilayer Perceptron,Radial Basis Function and Logistic Regression methods are presented to predict early risk detection of the cardiovascular event. A total of 929 (626 male and 303 female) heart attack data are used to construct the models.The models are tested using combined as well as separate male and female data. Among the models used, it is found that the Multilayer Perceptron model yields the best accuracy result.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)