Material and Methods: This experimental study involved 225 bone specimens prepared from discarded bone fragments during a series of 45 knee and hip arthroplasty surgeries. The bone fragments were cut into five identical cubes and were randomly assigned to either control (positive or negative), or experimental groups (0.5% chlorhexidine, 10% povidone-iodine or 70% alcohol). The control negative was to determine pre-contamination culture. All bone specimens, except the control negative group were uniformly contaminated by dropping on the operation theatre floor. Subsequently, the dropped bone specimens except for the control positive group, were disinfected by immersing in a respective antiseptic solution for 10 minutes, before transported to the microbiology laboratory for incubation.
Results: The incidence of a positive culture from a dropped bone fragment was 86.5%. From the 37 specimens sent for each group, the incidence of positive culture was 5.4% (2 specimens) after being disinfected using chlorhexidine, 67.6% (25 specimens) using povidone-iodine and 81.1% (30 specimens) using alcohol. Simple logistic regression analysis demonstrated that chlorhexidine was significantly effective in disinfecting contaminated bones (p-value <0.001, odd ratio 0.009). Povidone-iodine and alcohol were not statistically significant (p-value 0.059 and 0.53, respectively). Organisms identified were Bacillus species and coagulase negative Staphylococcus. No gram-negative bacteria were isolated.
Conclusion: A total of 0.5% chlorhexidine is effective and superior in disinfecting contaminated bones.
Materials and method: The cross-cultural adaptation was conducted based on standard guidelines to produce the Malay version of the Identification of Functional Ankle Instability (IdFAI-M) questionnaire. The reliability and validity testing were then performed among one hundred and twenty-three physically active University of Malaya students. Among them, twenty-two students also participated in the second return of the questionnaire over a two-week interval, which was then evaluated for test-retest reliability testing.
Results: The content validity for item-level (I-CVI) and Kappa values for all items were more than 0.7, respectively and the all scales-level (S-CVI) values were 0.983 (consistency), 0.967 (representativeness), 1.00 (relevance) and 0.983 (clarity). The questionnaire also demonstrated excellent reliability with an intraclass correlation coefficient (ICC2.1) above 0.850 for all items. It was observed that outer loading of most items were more than the minimum acceptable value (0.7). Fornell-Larcker criterion demonstrate all values for each reflective construct was larger than the correlations with other constructs, indicating discriminant. The cross-loading values of each item has shown a weak correlation with all other constructs, except for the one to which it was theoretically associated.
Conclusions: The Malay version of the IdFAI (IdFAI-M) is a reliable and valid instrument that can be readily utilised to subjectively assess ankle instability.
Materials and method: During the tournament, 14 teams participated in men's football, 12 teams in men's futsal and 11 teams in women's futsal. The biannual event involved athletes aged under 21 years. A medical report form used by FIFA Medical Assessment and Research Centre (F-Marc), was provided to the physiotherapists and team doctors of all the teams to report all injuries after each match.
Results: The response rate was 84.62% in football and 59.76% in futsal. A total of 48 injuries were reported from 26 football matches, equivalent to 64.64 injuries per 1000 match hours (95%CI 46.35 to 82.93). In futsal, a total of 48 injuries from 41 matches were reported, equivalent to 292.42 injuries per 1000 match hours (95% CI 209.7 to 375.14). The rate of injury in women futsal players was higher compared to men: 358.21 versus 247.04 injuries per 1000 match hours (p=0.224). Futsal recorded higher injuries per 1000 match hours than football (p<0.001).
Conclusion: The rate of severe injury in futsal and football recorded in the study as compared to previous studies gave rise to serious concerns. Hence, there was an urgent need to pay more attention to injury prevention strategies.
Material and Methods: We conducted a retrospective study of children with angular deformity of the knee treated by the guided growth technique from January 2010 to December 2015 in a tertiary centre. The guided growth technique was done using either the flexible titanium plate (8-plate) or the 2-hole reconstruction plate. Correction of deformity was assessed on radiographs by evaluating the mechanical axis deviation and tibiofemoral angle. The implants were removed once deformity correction was achieved.
Results: A total of 17 patients (27 knees) were evaluated. Twenty-two knees (81.5%) achieved complete correction of the deformity. The median age was 4.0 (interquartile range 3.0-6.0) years and the median Body Mass Index (BMI) was 26.0 (25.0-28.0). There were 7 unilateral and 10 bilateral deformities with different pathologies (14 tibia vara, 3 genu valgus). The median rate of correction was 0.71° per month. One patient (1 knee) had screw pull-out and two patients (4 knees) had broken screws in the proximal tibia. Three patients (5 knees) failed to achieve complete correction and were subsequently treated with corrective osteotomies. Out of five patients (8 knees) who were followed-up for at least 12 months after removal of hardware, two had rebound deformities. No permanent growth retardation occurred in our patients.
Conclusion: Our outcome for guided growth to correct knee angular deformity was similar to other studies. Guided growth is safe to perform in children below 12 years old and has good outcome in idiopathic genu valgus and Langeskiold II for tibia vara. Patients should be observed for recurrence until skeletal maturity following implant removal.
Material and methods: A randomised prospective study of 102 children (mean age 8.3 ± 3.5 years) with fractures involving upper or lower limbs. Children undergoing removal of cast were divided into 2 groups; either by an oscillating saw or a cast cutting shear. The level of anxiety was assessed by recording the heart rate with a portable fingertip pulse oximeter before, during and after removal of the cast. Objective assessment was performed by documenting the fear level on Children's Fear Scale (CFS).
Results: There was a significant increase in the heart rate of children during cast removal while using the oscillating saw compared to cast shear (p<0.05). The noise level produced by the saw exceeded 80 dB (mean 103.3 dB). The fear level was significantly lower in the cast shear group (p<0.05).
Conclusion: The noise produced by the oscillating saw was associated with an increased anxiety level in children undergoing cast removal. Cast shear is a simple and inexpensive instrument that can be used for cast removal in overly anxious children.
MATERIALS AND METHOD: This cross-sectional study was conducted at Klinik Rawatan Keluarga (KRK), Orthopedic clinic and wards in Hospital Universiti Sains Malaysia (USM) from May 2020 to December 2020. A total of 264 participants were recruited and divided into three groups: 50 diabetic patients with no ulcers (control), 107 patients with non-infected diabetic foot ulcers (NIDFU), and 107 patients with infected diabetic foot ulcers (IDFU). The level of PCT was taken for all patients. Total white count (TWC) and C-reactive protein (CRP) were taken only for IDFU patients. Diagnosis of infection was based on the Infectious Disease Society of America-International Working Group of Diabetic Foot (IDSA-IMWGDF), and the severity of infection was graded according to the Wagner Classification.
RESULTS: The level of PCT was higher in IDFU than in NIDFU and diabetic patient, with a median (IQR) of 0.355 (0.63) ng/mL, 0.077 (0.15) ng/mL and 0.028 (0.02) ng/mL, respectively. PCT and CRP showed moderate positive correlations in IDFU patients (p<0.001). The sensitivity and specificity were 63.6% and 83.2%, respectively, at the best cut-off at 0.25 ng/mL.
CONCLUSION: PCT is a valuable biomarker for the diagnosis of infection; however, it adds little value in the early diagnosis of IDFU in view of its low sensitivity.