Displaying publications 1 - 20 of 57 in total

Abstract:
Sort:
  1. Wahabi JM, Ung NM, Mahdiraji GA, Wong JHD
    Radiat Prot Dosimetry, 2024 Mar 02;200(3):264-273.
    PMID: 38123475 DOI: 10.1093/rpd/ncad303
    The radioluminescent (RL) dosemeter is excellent for real-time radiation measurement and can be used in various applications. A plastic scintillator is often the choice sensor because of its size and tissue equivalency. This study aims to characterise a novel plastic scintillator irradiated with high-energy photon beams. An RL dosimetry system was developed using the plastic scintillator. The RL dosimetry system was irradiated using a linear accelerator to characterise the dose linearity, dose rate, energy dependency and depth dose. The developed system showed a linear response toward the dose and dose rate. An energy dependency factor of 1.06 was observed. Depth dose measurement showed a mean deviation of 1.21% from the treatment planning system. The response and characteristics of the plastic scintillator show that it may be used as an alternative in an RL dosimetry system.
  2. Ahmed Shaker Hegian Z, Moh'd Abu Tahoun L, Ramli RM, Noor Azman NZ
    Radiat Prot Dosimetry, 2023 Dec 29;200(1):25-31.
    PMID: 37738470 DOI: 10.1093/rpd/ncad259
    The mean glandular dose (MGD) is a measurement used in mammography to assess the amount of radiation absorbed. By considering specific exposure radiation dose criteria, MGD ensures minimal radiation while maintaining image quality for detecting abnormalities. The relationship between MGD and compressed breast thickness (CBT) is commonly utilized in mammographic dose surveys. This study aims to estimate the MGD-CBT relationship based on patient age in Jordan through retrospective analysis. The analysis involved 3465 screening mammography images of women aged 40-80, divided into three age groups: 40-49, 50-64 and 65-80 years. Each group had a specific CBT range (16.5-156 mm). The results indicate that MGD ranges from 1.6 to 1.7 mGy across all three age groups, independent of CBT. Thus, a significant and positive correlation exists between MGD and CBT in all age groups.
  3. Khandaker MU, Zayadi NSB, Sani SFA, Bradley DA, Osman H, Alzamil Y, et al.
    Radiat Prot Dosimetry, 2023 Nov 02;199(18):2174-2178.
    PMID: 37934995 DOI: 10.1093/rpd/ncad179
    Present study concerns the radiological character of Malaysian honey. A total of 18 samples (representative of the various most common types) were obtained from various honey bee farms throughout the country. Using a high-purity germanium γ-ray spectroscopic system, the samples were analysed for the naturally occurring radionuclides 226Ra, 228Ra and 40K. The respective range of activities (in Bq/kg) was: 3.49 ± 0.35 to 4.51 ± 0.39, 0.99 ± 0.37 to 1.74 ± 0.39 and 41.37 ± 3.26 to 105.02 ± 6.91. The estimated associated committed effective doses were derived from prevailing data on national consumption of honey, the annual dose being found low compared with the UNSCEAR reference dose limit of 290 μSv y-1. The estimated threshold consumption rate for honey indicates a maximum intake of 339 g/d, which poses an insignificant radiological risk to public health; however, the total dietary exposure may not, the guidance level of 290 μSv y-1 being applicable to dietary intake of all foodstuffs. The study is in support of the cultivation of a healthy lifestyle, acknowledging prevailing radioactivity within the environment.
  4. Nadhiya A, Khandaker MU, Mahmud S, Abdullah WH
    Radiat Prot Dosimetry, 2023 Nov 02;199(18):2224-2228.
    PMID: 37934996 DOI: 10.1093/rpd/ncad213
    Concentrations of heavy metals in Yellowfin and Skipjack tuna fishes from the Laccadive sea were determined by inductively coupled plasma optical emission spectroscopy (ICP-OES) to evaluate the human health hazards via their consumption. The samples were collected from different atolls of Maldives to ensure a good representation of sample distribution. The metal concentration in tuna fish is found to be below the maximum tolerable limit set by different international organisations. The target hazard quotient values for individual metals were well below the limiting value of 1, indicating an insignificant health risk via the dietary intake of fish. The maximum targeted cancer risk value was 10 -4, indicating low carcinogenic risk from the consumption of tuna fish from the Maldives. Hence, the consumption of tuna from the Laccadive Sea is safe for human health.
  5. Abuzaid MM, Elshami W, Tekin HO, Sulieman A, Bradley DA
    Radiat Prot Dosimetry, 2021 Nov 03;196(1-2):10-16.
    PMID: 34423365 DOI: 10.1093/rpd/ncab125
    The present study compares three different multidetector CT (MDCT) scanners for routine brain imaging in terms of image quality and radiation doses. The volume CT dose index (CTDIvol), dose-length product (DLP), and effective dose (E) were calculated. Subjective image assessment was obtained based on a scale ranging from 1 (unacceptable) to 5 (optimum). All images scored 3.5 or over, with the 160-slice MDCT images being favoured. For the 4-, 16- and 160-slice MDCT scanners, the respective median values for CTDIvol were 57 mGy, 41 mGy, and 28 mGy; DLP values were 901 mGy.cm, 680 mGy.cm, and 551 mGy.cm; and effective doses were 2 mSv, 1.5 mSv, and 1 mSv, respectively. Compared to the 160-slice MDCT, the dose values for the 4- and 16-slice units were significantly greater. In practice, the CT modality used must be carefully selected to avoid elevated radiation doses and maintain image quality.
  6. Salah H, Al-Mohammed HI, Mayhoub FH, Sulieman A, Alkhorayef M, Abolaban FA, et al.
    Radiat Prot Dosimetry, 2021 Oct 12;195(3-4):349-354.
    PMID: 34144608 DOI: 10.1093/rpd/ncab077
    This study has sought to evaluate patient exposures during the course of particular diagnostic positron emission tomography and computed tomography (PET/CT) techniques. A total of 73 patients were examined using two types of radiopharmaceutical: 18F-fluorocholine (FCH, 48 patients) and 68Ga-prostate-specific membrane antigen (PSMA, 25 patients). The mean and range of administered activity (AA) in MBq, and effective dose (mSv) for FCH were 314.4 ± 61.6 (462.5-216.8) and 5.9 ± 1.2 (8.8-4.11), respectively. Quoted in the same set of units, the mean and range of AA and effective dose for 68Ga-PSMA were 179.3 ± 92.3 (603.1-115.1) and 17.9 ± 9.2 (60.3-11.5). Patient effective doses from 18F-FCH being a factor of two greater than the dose resulting from 68Ga-PSMA PET/CT procedures. CT accounts for some 84 and 23% for 18F-FCH and 68Ga-PSMA procedures, accordingly CT acquisition parameter optimization is recommended. Patient doses have been found to be slightly greater than previous studies.
  7. Sulieman A, Mayhoub F, Ibrahim HS, Omer H, Alkhorayef M, Abolaban FA, et al.
    Radiat Prot Dosimetry, 2021 Oct 12;195(3-4):314-318.
    PMID: 34265851 DOI: 10.1093/rpd/ncab107
    The objective of this study is to estimate the annual effective dose for cardiologists and nurses by measuring Hp(10) and Hp(0.07) during cardiac catheterization procedures. A total of 16 staffs members were working in interventional cardiology during 1 year at a tertiary hospital. The occupational dose was measured using calibrated thermo-luminescent dosemeters (TLD-100, LiF:Mg,Ti). The overall mean and range of the annual Hp(10) and Hp(0.07) (mSv) for cardiologists were 3.7 (0.13-14.5) and 3.2 (0.21-14.7), respectively. Cardiologists were frequently exposed to higher doses compared with nurses and technologists. The exposure showed wide variations, which depend on occupation and workload. Staff is adhered to radiation protection guidelines regarding shielding the trunk, thyroid shield, thus appropriately protected. Lens dose measurement is recommended to ensure that dose limit is not exceeded.
  8. Rizk C, Askounis P, Okyar HB, Sangau JK, Baradaran S, Al Fares E, et al.
    Radiat Prot Dosimetry, 2020 Aug 28;190(2):217-225.
    PMID: 32696972 DOI: 10.1093/rpd/ncaa093
    This paper presents the results of the evaluation of the uncertainty in measurement of the personal dose equivalent, Hp(10), at nine individual monitoring services (IMSs) in Asia and the Pacific region. Different types of passive dosemeters were type-tested according to the International Electrotechnical Commission 62387 requirements. The uncertainty in measurement was calculated using the Guide to the Expression of Uncertainty in Measurement approach. Expanded uncertainties ranged between 24 and 86% (average = 38%) for Hp(10) values around 1 mSv and between 14 and 40% (average = 27%) for doses around the annual dose limit, Hp(10) = 20 mSv. The expanded uncertainties were lower than the 1.5 factor in either direction proposed by the International Commission on Radiological Protection for doses near the relevant dose limits. This indicates an acceptable level of uncertainty for all participating IMSs. Uncertainty evaluation will help the IMSs to acknowledge the accuracy of their measurements.
  9. Mocktar FA, Abdul Razab MKA, Mohamed Noor A
    Radiat Prot Dosimetry, 2020 Jul 07;189(1):69-75.
    PMID: 32090244 DOI: 10.1093/rpd/ncaa014
    This study aims to reduce radon gas emanations in the indoor environment by incorporating kenaf and oil palm nanocellulose that act as nano-fillers into building materials. Fabrication of composite brick was carried out according to the MS and ASTM standards. In this research, 40, 80, 120, 160 and 200 ml of nanocellulose were used to replace the usage of sand, stone and cement materials, respectively. Kenaf and oil palm nanocellulose were utilised to reduce the internal and surface porosity as well as to replace the radon resources (stone), which indirectly reduced radon gas emanation. Radon gas emanated from each composite brick was measured within 10 consecutive days in an airtight prototype Perspex room using Radon Monitor Sentinel 1030. A compression test was also carried out to investigate the physical strength of the fabricated composite bricks. The results showed that 40 ml of kenaf and oil palm nanocellulose was the optimum amount in reducing the radon concentration, where the radon readings were 1.4 and 0.93 pCi per l, respectively. Meanwhile, the brick with no nanocellulose exhibited the highest radon reading of 3.77 pCi per l. Moreover, the Young modulus for the composite brick of both kenaf and oil palm nanocellulose was 28.92 and 27.8 N per mm2 compared to the control brick, which was 27 N per mm2. The results proved that radon gas emanations were reduced by 62.86% for kenaf and 75.3% for oil palm by incorporating the organic nanocellulose, which has high potential towards a healthy indoor environment.
  10. Tajudin SM, Namito Y, Sanami T, Hirayama H
    Radiat Prot Dosimetry, 2020 Jul 02;188(4):486-492.
    PMID: 31950186 DOI: 10.1093/rpd/ncz308
    As a reference photon field, several radionuclides have been used frequently, such as 241Am,137Cs and60 Co for calibration. These nuclides provide mono-energy photons for dosemeters covering few tens of keV-MeV. The main energy around 200 keV is important for both environmental and medical fields since the former should consider scattering photons and the later should measure photons from X-ray generator. In our previous work, a backscattered layout can provide a uniform photon field spectra and dose rate with an energy of 190 keV by using an affordable intensity 137 Cs gamma source. Several other quasi-monoenergetic photon fields in the range of 100-200 keV could be obtained by using several available gamma sources. Two calibrated environmental CsI(Tl) survey meters, Horiba PA-1000 and Mr. Gamma A2700, had been measured with the developed backscattered photon field to understand energy-dependent features in order to confirm dosemeter readings. Consequently, both scintillator instruments are sensitive for measurements of the relatively low dose rates at 190 keV.
  11. Bohari A, Hashim S, Mohd Mustafa SN
    Radiat Prot Dosimetry, 2020 Jun 24;188(3):397-402.
    PMID: 31950168 DOI: 10.1093/rpd/ncz299
    Radiation scattered throughout the room during fluoroscopy-guided interventional (FGI) procedures was quantified at different locations using nanoDot optically stimulated luminescence dosemeters. All the tube angulation imaging shows that the radiation spectrum resembled a single peak distribution. The left anterior oblique 90° shows the highest single peak distribution (28.65 mSv/h). The single peak distribution for standard anteroposterior, left anterior oblique 45° and right anterior oblique 45° imaging was 13.32, 22.99 and 17.40 mSv/h, respectively. All tube angulation shows that the position of the interventional radiologist experienced a higher radiation level compared to other staffs. The doses of radiation varied widely around the perimeter of the patient's table and changed in accordance to imaging angles during procedures. Knowledge pertaining to radiation exposure levels is integral in order to avoid adverse risks, particularly among staff.
  12. Razali MASM, Ahmad MZ, Shuaib IL, Osman ND
    Radiat Prot Dosimetry, 2020 Jun 13;188(2):213-221.
    PMID: 31885043 DOI: 10.1093/rpd/ncz278
    The aim of this study was to propose local diagnostic reference levels (LDRLs) for the most common computed tomography (CT) examinations (including contrast and non-contrast scan phase) performed at Advanced Medical and Dental Institute (AMDI), Universiti Sains Malaysia (USM), Malaysia. A retrospective CT dose survey of 1488 subjects from January 2015 until December 2018 was performed at AMDI USM, Malaysia. The proposed DRLs were established at 50th and 75th percentile of dose distribution for all dose metrics (CT dose index [CTDI]; CTDIvol, CTDIw and dose-length product). The proposed LDRLs were compared with national DRLs and other established DRLs. The 10 most common CT examinations at AMDI were thorax-abdomen-pelvis (TAP) CT (46%), followed by pelvis CT (17%), abdomen-pelvis CT (10%), brain/head CT (9%) and other CT protocols. The local DRLs were established using the third quartile values of dose distribution and were categorized based on CT region protocols. Most of the proposed DRLs were exceeded the national DRLs (63%) and other international DRLs (67%). From the dose auditing, almost half of the recent dose data (for year 2018) exceeded the proposed local DRLs and the unusual dose were observed in TAP, brain/head and pelvis CT examinations. The unusual higher dose could be due to higher mAs settings, higher number of scan phase for contrast study and higher pitch factor. The local DRLs should be established for dose optimization and reduction of the occurrence of excessive radiation exposure to the patients. The establishment of the Ads and LDRLs should also consider all the factors that affect the variation in DRLs such as CT technology, scanning protocols and population characteristics. The local dose distribution should always be revised for improvement of the current local practice.
  13. Al Mutairi AMM, Kabir NA
    Radiat Prot Dosimetry, 2020 Jun 12;188(1):47-55.
    PMID: 31711202 DOI: 10.1093/rpd/ncz256
    Tapioca and sweet potato are the fourth and fifth most consumed crops in Malaysia. The activity concentrations of natural radionuclides in these vegetables were assessed from two regions in Malaysia (Kedah and Penang) along with soil samples using gamma ray spectroscopy. The transfer factors of 226Ra, 232Th and 40K from soil to vegetables were calculated, and a dose assessment was performed. The activity concentrations of 226Ra, 232Th and 40K in soil samples did not show a significant variation with the regions investigated, and the average values obtained, in Bq/kg, (±SD) were as follows: 80 ± 41, 56 ± 12, 516 ± 119, respectively. The respective average activity concentrations in vegetables were as follows, in Bq/kg: (±SD) 2.0 ± 0.5, 6 ± 2, 153 ± 49. The corresponding transfer factors were calculated to be 0.03, 0.11 and 0.31 for 226Ra, 232Th and 40K, respectively. The average annual effective doses due to the exposure from soil and ingestion of vegetables were found to lie within the worldwide ranges.
  14. Bohari A, Hashim S, Ghoshal SK, Mohd Mustafa SN
    Radiat Prot Dosimetry, 2019 Dec 31;186(4):462-468.
    PMID: 31329977 DOI: 10.1093/rpd/ncz051
    Long exposure to radiation from fluoroscopy-guided interventions (FGIs) can be detrimental to both patients and radiologists. The effective doses received by the interventional radiology staff after performing 230 FGIs in a year were assessed by using double dosimetry and five various algorithms. The Shapiro-Wilk test revealed normally-distributed data (p < 0.01), while the significant correlation coefficients between the effective doses ranged between 0.88 and 1.00. As for the Bland-Altman analysis, both Niklason and Boetticher algorithms strongly supported the absence of statistical significance between the estimated effective doses. This portrays that the occupational doses received by the interventional radiology staff during FGIs fall within the acceptable limit regardless of the varied algorithms applied. In short, the Niklason and Boetticher algorithms appeared to be the more interchangeable ones for effective evaluation of doses. This is in view of their strong mutual correlations and excellent agreement.
  15. Khandaker MU, Uwatse OB, Bin Shamsul Khairi KA, Faruque MRI, Bradley DA
    Radiat Prot Dosimetry, 2019 Dec 31;185(3):343-350.
    PMID: 30806465 DOI: 10.1093/rpd/ncz018
    Batu Dam is of considerable importance to the metropolis of Kuala Lumpur, its existence and the quality assessment of its waters being essential in helping to maintain the lives of a large sector of the Malaysian population. Concerning the level of naturally occurring radioactivity contained within its waters, a well characterised HPGe γ-ray technique has been used in making measurements of the concentrations of primordial radionuclides in samples of surface water from the Dam. Based on the mean individual daily consumption of dam water, estimation has been made of the concomitant radiation dose. Activity concentrations, in units of Bq l-1, have been found to be in the range 2.4-3.2 for 226Ra, 1.1-1.3 for 232Th and 22.7-40.7 for 40K, in line with literature data for surface waters. The total annual ingestion dose for infants (<1 y) and adolescents (12-17 y) are found to be significant and greater than the World Health Organization recommended maximum dose of 0.1 mSv y-1 from the imbibing of drinking water. However, the Dam water does not pose a threat to public health, the Dam water not being used as the sole source of drinking water. Noting that this is the only known study of water from Batu Dam, the reported levels allow for evaluation of future changes in the natural radioactivity profile.
  16. Abdullahi S, Ismail AF, Samat S
    Radiat Prot Dosimetry, 2019 Dec 31;186(4):520-523.
    PMID: 31034551 DOI: 10.1093/rpd/ncz125
    The activity concentrations of 226Ra, 232Th and 40K radionuclides from common building materials used by Malaysian people for construction purposes were studied using High-Purity Germanium (HPGe) detector. The measured activity concentrations of the aforementioned radionuclides range from 10 ± 1 Bq kg-1 (limestone) to 155 ± 61 Bq kg-1 (feldspar), 12 ± 3 Bq kg-1 (limestone) to 274 ± 8 Bq kg-1 (kaolin) and 62 ± 19 Bq kg-1 (limestone) to 1114 ± 20 Bq kg-1 (pottery stone) for 226Ra, 232Th and 40K, respectively. The measured activity concentrations of the natural radionuclides reported herein were found to be in accordance with other previous studies. In general, the activity concentration of the natural radionuclides revealed that all the determined values were below the recommended limit.
  17. Rizk C, Long S, Okyar HB, Baradaran S, Al Fares E, Sangau JK, et al.
    Radiat Prot Dosimetry, 2019 Dec 31;187(4):418-425.
    PMID: 31605130 DOI: 10.1093/rpd/ncz182
    An intercomparison exercise (IC) on whole body dosemeters to determine the quantity personal dose equivalent Hp (10) in photon radiation fields was jointly organised and conducted by the International Atomic Energy Agency (IAEA) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) for individual monitoring services (IMS) in Asia and the Pacific region. This was arranged to help the IMS in the region to achieve a more accurate dosimetry service and to improve their performance. Twenty-four IMS participated in this IC. Four sets of dosemeters were irradiated using X-ray and gamma radiation qualities at 0° and 20° angle of incidence, respectively. All the IMS provided results that were within the acceptable limits defined by the IAEA. However, only a minority of participants reported confidence intervals that included the reference dose, for each exposure scenario. For few systems, the overall performance could be significantly improved by reviewing calibration procedures.
  18. Wong JHD, Bakhsh M, Cheah YY, Jong WL, Khor JS, Ng KH
    Radiat Prot Dosimetry, 2019 Dec 31;187(4):451-460.
    PMID: 31650160 DOI: 10.1093/rpd/ncz186
    This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reader accuracy, reproducibility, batch homogeneity, energy dependence and signal stability, were explored. The suitability of the nanoDot™ dosemeters was evaluated by measuring the depth dose curve, in vivo dose measurement and image perturbation. The nanoDot™ dosemeters were observed to produce a linear dose with ±2.8% coefficient variation. Significant batch inhomogeneity (8.3%) was observed. A slight energy dependence (±6.1%) was observed between 60 and 140 kVp. The InLight® microStar reader demonstrated good accuracy and a reproducibility of ±2%. The depth dose curve measured using nanoDot™ dosemeters showed slightly lower responses than Monte Carlo simulation results. The total uncertainty for a single dose measurement using this system was 11%, but it could be reduced to 9.2% when energy dependence correction was applied.
  19. Nasser SM, Khandaker MU, Bradley DA, Isinkaye MO
    Radiat Prot Dosimetry, 2019 Oct 01;184(3-4):422-425.
    PMID: 31038706 DOI: 10.1093/rpd/ncz088
    The present study concerns measurement of the radon concentration in drinking and irrigation waters obtained from the eastern part of Oman, in particular in regard to water quality assessment of the region. The samples were collected from different places covering most types of water sources in the region. A passive and time-integrated track etch detector (LR-115 type II) combined with a high-resolution optical microscope has been used to obtain the radon concentration in the studied samples. Values of dissolved radon in water varied among the water sources; the highest concentration of radon was found to be 363 Bq m-3 in a drinking water sample while well water used for irrigation showed the lowest value, at 140 Bq m-3. Measured data for all water sources are below the permissible limit of 11.1 kBq m-3 recommended by the US-EPA. Annual effective doses for the studied samples were in the range 0.38-0.99 μSv y-1 which is significantly less than the action level recommended by the WHO (0.1 mSv y-1), indicating that the water sources in the Jalan BBH region of Oman are safe to use. The obtained data may serve as a reference for any future radiological study of the waterbody of this region.