Displaying publications 1 - 20 of 84 in total

Abstract:
Sort:
  1. Leong CL
    Talanta, 1971 Aug;18(8):845-8.
    PMID: 18960953
    A ternary complex between germanium, Catechol Violet (CV) and cetyltrimethylanunoniuni bromide is proposed for the determination of germanium. The stoichiometric ratio Ge:CV is 1:2. Beer's law is obeyed from 0.1 to 1.0 ppm of Ge. The method is highly selective. Interference from Sn(IV), Fe(III), Bi(III), Cr(VI), Mo(VI), V(V) and Sb(III) in mg amounts is eliminated by extracting the germanium into carbon tetrachloride from 9M HC1 and then stripping into water before the photometric determination.
  2. Chong C
    Talanta, 1986 Jan;33(1):91-4.
    PMID: 18964038
    A simple atomic-absorption spectrophotometry method is described for the determination of silver, bismuth, cadmium, copper, iron, nickel and zinc in lead- and tin-base solders and white-metal bearing alloys, with use of a single sample solution. The sample is dissolved in a mixture of hydrobromic acid and bromine, then fumed with sulphuric acid. The lead sulphate is dissolved in concentrated hydrochloric acid. The method is particularly suitable for the determination of silver and bismuth, which are co-precipitated with lead sulphate. The other elements can also be determined after removal of the lead sulphate by filtration.
  3. Saleh MI, Ahmad M, Darus H
    Talanta, 1990 Jul;37(7):757-9.
    PMID: 18965016
    A series of chelating reagents, 1-phenyl-3-methyl-4-(2-fluorobenzoyl)-5-pyrazolone, 1-phenyl-3-methyl-4-(3-fluorobenzoyl)-5-pyrazolone and 1-phenyl-3-methyl-4-(4-fluorobenzoyl)-5-pyrazolone, has been synthesized. The extraction of Ln(III), (Ln = La, Eu and Lu) into chloroform with these reagents at 30 +/- 1 degrees has been studied. The composition of the complexes extracted has been determined by the slope method, and the extraction constants K(ex), were measured. The presence of the fluorine atom in the reagents does not make the K(ex), values much different from those obtained with the parent pyrazolone.
  4. Saad B, Kanapathy K, Ahmad MN, Hussin AH, Ismail Z
    Talanta, 1991 Dec;38(12):1399-402.
    PMID: 18965315
    Three main types of PVC solvent polymeric membrane ion-selective electrodes for chloroquine are described. They are based on three ion-pairing agents namely dipicrylamine (DPA), tetraphenylborate (TPB) or tetrakis(4-chlorophenyl)borate (TCPB) with either dioctylphenyl phosphonate (DOPP) or trioctyl phosphate (TOP) solvent mediator. All electrodes exhibit Nernstian responses, fast dynamic response times and a wide useful pH range. The best all-round electrode is based on TPB and TOP plasticizing solvent mediators with a limit of detection of 7.1 x 10(-6)M and was utilized for the assay of chloroquine in tablets. Direct potentiometric determinations with either the analyte addition method or the normal calibration method gave results comparable to the official method.
  5. Anuar K, Hamdan S
    Talanta, 1992 Dec;39(12):1653-6.
    PMID: 18965586
    A new lead(II) electrode has been constructed with poly(hydroxamic acid) (PHXA) as the active material and silicone rubber as the supporting material. The electrode gave near Nerstian response over the concentration range 4 x 10(-5)-1 x 10(-2)M lead(II). The detection limit of the electrode is approximately 4 x 10(-6)M and the electrode works well in the pH range 4.5-6.0. The response time was 50-120 sec over the whole concentration range and the electrode has a working life of at least 4 weeks. Iron(III) severely poisoned the electrode membrane. Nickel(II) and mercury(II) gave very strong interference compared to copper(II), silver(I), cobalt(II), sodium(I), potassium(I), zinc(II) and cadmium(II) which gave some or little interference. Values determined with atomic absorption (AAS) and a commercial lead(II) electrode were in good agreement with those measured with the lead(II) electrode reported here.
  6. Haron MJ, Wan Md ZW, Desa MZ, Kassim A
    Talanta, 1994 May;41(5):805-7.
    PMID: 18966002
    Poly(hydroxamic acid) chelating ion-exchange resin was prepared from crosslinked poly(methacrylate) beads. The starting polymer was prepared by a suspension polymerization of methacrylate and divinyl benzene. Conversion of the ester groups into the hydroxamic acid was carried out by treatment with hydroxylamine in an alkaline solution. Hydroxamic acid capacity of the product was 2.71 mmol/g. The resin exhibited high affinity towards Fe(III) and Pb ions and its capacities for Fe(III), Pb, Cu, Ni and Co ions were pH dependent. The ability of the resin to carry out the separation of Fe(III)CuCo/Ni and PbNi ions is also reported.
  7. Ahmad M, Narayanaswamy R
    Talanta, 1995 Sep;42(9):1337-44.
    PMID: 18966361
    Chrome azurol S immobilised on XAD-2 has been used in this study as a reagent phase for the development of an optical fibre Al(III) sensor. Using a kinetic approach, this sensor was able to give a linear response in the Al(III) concentration range of 1.3 x 10(-5)-2.0 x 10(-4) M with a limit of detection of 1.0 x 10(-4) M. The optimum responses were obtained at pH 6.0 and when the solution was stirred. The sensor response was found to have a repeatability and reproducibility of 1.6% and 5.8%, respectively. The results obtained for Al(III) determination in aqueous sample were in good agreement with those obtained using graphite furnace-atomic absorption spectrometry.
  8. Poh BL, Khairuddean M
    Talanta, 1996 Oct;43(10):1727-31.
    PMID: 18966659
    A non-cyclic tetrameric structure has been suggested for calcichrome (calcion). This structure is consistent with its mass spectrum, proton NMR spectrum, elemental composition and complexing ability with polyaromatic hydrocarbons in water. The stability constants of the 1:1 complexes formed between calcichrome and seven polyaromatic hydrocarbons in water at room temperature have been measured.
  9. Ahmad M, Hamzah H, Sufliza Marsom E
    Talanta, 1998 Oct;47(2):275-83.
    PMID: 18967326
    An optical sensor for Hg(II) monitoring using a complex of zinc dithizonate immobilised on XAD 7 which is based on reflectance spectrophotometry has been developed in this study. Measurements were made using a kinetic approach whereby the reflectance signal is measured at a fixed time of 5 min. The sensor could be regenerated using a saturated solution of KCl in 1 M sulphuric acid. The sensor was found to have an optimum response at pH 3.0 with respective measurement repeatability and probe-to-probe reproducibility of 1.53% and 5.26%. A linear response was observed in the Hg(II) concentration range of 0.0-180.0 ppm with a calculated limit of detection (LOD) of 0.05 ppm. The results obtained for aqueous Hg(II) determination using this probe were found to be comparable with the well-established method of atomic absorption spectrometry.
  10. Saad B, Ariffin M, Saleh MI
    Talanta, 1998 Dec;47(5):1231-6.
    PMID: 18967428
    A flow injection potentiometric method for the rapid determination of paraquat in herbicide formulations and biological samples is described. It is based on the utilization of a flow-through potentiometric detector containing polyvinyl chloride-immobilised octamethylcyclotetrasiloxane, a lipophilic plasticizer (tetra-n-undecyl 3,3',4,4'-benzophenone tetracarboxylate) and membrane additive potassium tetrakis(4-chlorophenyl)borate. The detector was minimally interfered by the presence of constituents such as Na(+), K(+), Ca(2+), Mg(2+), glucose, urea, lactic and citric acids at physiological levels, respectively. Good correlation between results of the proposed method and HPLC for the formulation samples was found, while results for the determination of paraquat in biological samples such as urine, vomitus and stomach washout was less satisfactory.
  11. Yusof NA, Ahmad M
    Talanta, 2002 Sep 12;58(3):459-66.
    PMID: 18968772
    Gallocynin immobilized in chitosan membrane has been studied as a sensor element of an optical sensor for lead using a flowing system. By using this set up, lead in solution has been determined in the concentration range from 1.0x10(-1) to 1.0x10(3) ppm with a detection limit of 0.075 ppm. The standard deviation of the method for the repeatability of lead detection at a concentration of 100 ppm was found to be 2.10%. The response of the sensor was reproducible and can be regenerated by using acidified saturated KNO(3) solution. Interference from foreign ions was also studied at 1:1 mole ratio of Pb(II):foreign ions.
  12. Bin Abas MR, Takruni IA, Abdullah Z, Tahir NM
    Talanta, 2002 Nov 12;58(5):883-90.
    PMID: 18968820
    A flow injection (FI) method with on-line preconcentration using a mini-column loaded with 8-hydroxyquinoline immobilized on controlled pore glass (CPG-8HQ) is described for the determination of trace metals by ion chromatography (IC) with pyridine-2-6-dicarboxylic acid (PDCA) as the eluent. Copper, cadmium, lead, zinc, nickel and iron were determined at ppb level after post-column derivatization with 4-(2-pyridylazo)-resorcinol (PAR). The detection limits (3sigma) for the FI/IC system were 8.27, 0.89, 0.09, 0.06, 0.09 and 0.07 g l(-1) for Pb(2+), Cd(2+), Cu(2+) Ni(2+), Zn(2+) and Fe(3+), respectively, using 5 ml sample volume. The method was applied to the analysis of Malaysian natural waters.
  13. Tan BL, Ali Mohd M
    Talanta, 2003 Nov 4;61(3):385-91.
    PMID: 18969198 DOI: 10.1016/S0039-9140(03)00281-9
    A total of seven pesticides and eight alkylphenols were monitored using this method for the determination of their trace levels in human cord blood. The pesticides are lindane, diazinon, alpha-endosulfan, beta-endosulfan, endosulfan sulfate, chlorpyrifos and endrin; while the alkylphenols are 4-n-butylphenol, 4-n-pentylphenol, 4-n-hexylphenol, 4-t-octylphenol, 4-n-heptylphenol, nonylphenol, 4-n-octylphenol and bisphenol A. The pesticides and alkylphenols in the cord blood samples were extracted with solid phase extraction IST C18 cartridges and analyzed by selected ion monitoring mode using quadrapole detector in Shimadzu QP-5000 gas chromatograph-mass spectrometer. Trace levels of pesticide and alkylphenols in the range of non-detectable to 15.17 ng ml(-1), were detected in the human cord blood samples. This technique of monitoring the levels of endocrine-disruptors in blood samples is consistent, reliable and cost effective while reducing wastage of time and solvents.
  14. Wong FC, Ahmad M, Heng LY, Peng LB
    Talanta, 2006 Jun 15;69(4):888-93.
    PMID: 18970653 DOI: 10.1016/j.talanta.2005.11.034
    An optical biosensor consisting of a chromoionophore (ETH5294) (CM) doped sol-gel film interfaced with another sol-gel film immobilized with acetylcholinesterase (AChE) was employed to detect the insecticide dichlorvos. The main advantage of this optical biosensor is the use of a sol-gel layer with immobilized CM that possesses lipophilic property. The highly lipophilic nature of the CM and its compatibility with the sol-gel matrix has prevented leaching, which is frequently a problem in optical sensor construction based on pH indicator dyes. The immobilization of the indicator and enzyme was simple and need no chemical modification. The CM layer is pH sensitive and detects the pH changes of the acetylcholine chloride (AChCl) substrate when hydrolyzed by AChE layer deposited above. In the absence of the AChE layer, the pH response of the CM layer is linear from pH 6 to 8 (R(2)=0.98, n=3) and it showed no leaching of the lipophilic chromoionophore. When the AChE layer is deposited on top, the optical biosensor responds to AChCl with a linear dynamic range of 40-90mM AChCl (R(2)=0.984, n=6). The response time of the biosensor is 12min. Based on the optimum incubation time of 15min, a linear calibration curve of dichlorvos against the percentage inhibition of AChE was obtained from 0.5 to 7mg/L of dichlorvos (17-85% inhibition, R(2)=0.991, n=9). The detection limit for dichlorvos was 0.5mg/L. The results of the analysis of 1.7-6.0mg/L of dichlorvos using this optical biosensor agreed well with a gas chromatography-mass spectrometry detection method.
  15. Abdullah J, Ahmad M, Heng LY, Karuppiah N, Sidek H
    Talanta, 2006 Oct 15;70(3):527-32.
    PMID: 18970803 DOI: 10.1016/j.talanta.2005.12.061
    The development of an optical biosensor based on immobilization of 3-methyl-2-benzothiazolinone hydrazone (MBTH) in hybrid nafion/sol-gel silicate film and tyrosinase in chitosan film for the detection of phenolic compounds has been described. Tyrosinase was immobilized in chitosan film deposited on the hybrid nafion/sol-gel silicate film containing MBTH. The enzymatic oxidation product of phenolic compounds were stabilized through formation of adduct with MBTH to produce a maroon color adduct. The color intensity of adduct was found to increase proportionally with the increase of the substrate concentrations after 5min exposure. The linearity of the biosensor towards phenol, catechol and m-cresol were in the respective concentration range of 0.5-7.0, 0.5-10.0 and 1.0-13.0mg/L with detection limit of 0.18, 0.23 and 0.43mg/L, respectively. The biosensor shows a good stability for at least 3 months.
  16. Isa IM, Ab Ghani S
    Talanta, 2007 Jan 15;71(1):452-5.
    PMID: 19071326 DOI: 10.1016/j.talanta.2006.04.034
    This paper describes the preparation of and experimentation undertaken by heterogeneous chitosan membrane as ion selective electrode for glutamate ion. The linearity response was obtained in the range of 1.0x10(-5) to 1.0x10(-1)M with a detection limit of 1.0x10(-6)M. The performance of the electrode was found in the pH range of 4.0-8.0 at temperature 25+/-3 degrees C. The response time was at 5-35s and was useful for a period of more than 4 months. The selectivity values towards some anions indicates good selectivity over a number of interfering anions. No significant improvement of membrane performance over additional of plasticizers such as 2-NPOE, BEHA and DOPP. The electrodes gave sufficient Nernstian responses with the exception of membrane with 2-NPOE.
  17. Elbashir AA, Suliman FE, Saad B, Aboul-Enein HY
    Talanta, 2009 Feb 15;77(4):1388-93.
    PMID: 19084654 DOI: 10.1016/j.talanta.2008.09.029
    A capillary electrophoretic method for the separation of the aminoglutethimide (AGT) enantiomers using methylated-beta-cyclodextrin (M-beta-CD) as chiral selector is described. Several parameters affecting the separation were studied, including the type and concentration of chiral selector, buffer pH, voltage and temperature. Good chiral separation of the racemic mixture was achieved in less than 9 min with resolution factor Rs=2.1, using a fused-silica capillary and a background electrolyte (BGE) of tris-phosphate buffer solution (50 mmol L(-1), pH 3.0) containing 30 mgm L(-1) of M-beta-CD. The separation was carried out in normal polarity mode at 25 degrees C, 16 kV and using hydrostatic injection. Acceptable validation criteria for selectivity, linearity, precision, and accuracy/recovery were included. The proposed method was successfully applied to the assay of AGT enantiomers in pharmaceutical formulations. The computational calculations for the inclusion complexes of the R- and S-AGT-M-beta-CD rationalized the reasons for the different migration times between the AGT enantiomers.
  18. Saaid M, Saad B, Rahman IA, Ali AS, Saleh MI
    Talanta, 2010 Jan 15;80(3):1183-90.
    PMID: 20006072 DOI: 10.1016/j.talanta.2009.09.006
    Three sorbent materials (A18C6-MS, DA18C6-MS and AB18C6-MS) based on the crown ether ligands, 1-aza-18-crown-6, 1,4,10,13-tetraoxa-7,16-diazacyclo octadecane and 4'-aminobenzo-18-crown-6, respectively, were prepared by the chemical immobilization of the ligand onto mesoporous silica support. The sorbents were characterized by FT-IR, scanning electron microscopy-energy dispersive X-ray microanalysis, elemental analysis and nitrogen adsorption-desorption test. The applicability of the sorbents for the extraction of biogenic amines by the batch sorption method was extensively studied and evaluated as a function of pH, biogenic amines concentration, contact time and reusability. Under the optimized conditions, all the sorbents exhibited highest selectivity toward spermidine (SPD) compared to other biogenic amines (tryptamine, putrescine, histamine and tyramine). Among the sorbents, AB18C6-MS offer the highest capacity and best selectivity towards SPD in the presence of other biogenic amines. The AB18C6-MS sorbent can be repeatedly used three times as there was no significant degradation in the extraction of the biogenic amines (%E>85). The optimized procedure was successfully applied for the separation of SPD in food samples prior to the reversed-phase high performance liquid chromatography separation.
  19. Makahleh A, Saad B, Siang GH, Saleh MI, Osman H, Salleh B
    Talanta, 2010 Apr 15;81(1-2):20-4.
    PMID: 20188881 DOI: 10.1016/j.talanta.2009.11.030
    A reversed-phase high-performance liquid chromatographic method with capacitively coupled contactless conductivity detector (C(4)D) has been developed for the separation and the simultaneous determination of five underivatized long chain fatty acids (FAs), namely myristic, palmitic, stearic, oleic, and linoleic acids. An isocratic elution mode using methanol/1mM sodium acetate (78:22, v/v) as mobile phase with a flow rate of 0.6 mL min(-1) was used. The separation was effected by using a Hypersil ODS C(18) analytical column (250 mm x 4.6 mm x 5 microm) and was operated at 45 degrees C. Calibration curves of the five FAs were well correlated (r(2)>0.999) within the range of 5- 200 microg mL(-1) for stearic acid, and 2-200 microg mL(-1) for the other FAs. The proposed method was tested on four vegetable oils, i.e., pumpkin, soybean, rice bran and palm olein oils; good agreement was found with the standard gas chromatographic (GC) method. The proposed method offers distinct advantages over the official GC method, especially in terms of simplicity, faster separation times and sensitivity.
  20. Tameem AA, Saad B, Makahleh A, Salhin A, Saleh MI
    Talanta, 2010 Sep 15;82(4):1385-91.
    PMID: 20801345 DOI: 10.1016/j.talanta.2010.07.004
    A sorbent material based on a newly synthesized hydrazone ligand, 4-hydroxy-N'-[(E)-(2-hydroxyphenyl)methylidene]benzohydrazide was prepared by immobilizing the ligand into a silica sol-gel matrix. The capability of the sorbent material for the extraction of seven biogenic amines (BAs), i.e., tryptamine (TRY), beta-phenylethylamine (PEA), putrescine (PUT), cadaverine (CAD), histamine (HIS), tyramine (TYR), and spermidine (SPD) was studied. Under the adopted conditions, the sorbent showed good selectivity towards PUT, CAD, HIS and SPD (% extraction (%E)>96) while %E for TYR, TRY and PEA were 82.0, 78.9 and 46.4%, respectively. The sorbent could be used up to six extraction cycles for SPD, CAD and PUT and was applied to the determination of food samples ("budu", ketchup, orange juice, soy sauce) that were spiked with 20 mg L(-1) of the BAs. The extracted analytes were derivatized with dansyl chloride before the HPLC determination. With the exception of HIS and TYR in "budu" sample, reasonable recoveries were found for the other analytes in all the tested food samples.