Displaying publications 1 - 20 of 76 in total

Abstract:
Sort:
  1. Saad SM, Andrew AM, Shakaff AY, Saad AR, Kamarudin AM, Zakaria A
    Sensors (Basel), 2015;15(5):11665-84.
    PMID: 26007724 DOI: 10.3390/s150511665
    Monitoring indoor air quality (IAQ) is deemed important nowadays. A sophisticated IAQ monitoring system which could classify the source influencing the IAQ is definitely going to be very helpful to the users. Therefore, in this paper, an IAQ monitoring system has been proposed with a newly added feature which enables the system to identify the sources influencing the level of IAQ. In order to achieve this, the data collected has been trained with artificial neural network or ANN--a proven method for pattern recognition. Basically, the proposed system consists of sensor module cloud (SMC), base station and service-oriented client. The SMC contain collections of sensor modules that measure the air quality data and transmit the captured data to base station through wireless network. The IAQ monitoring system is also equipped with IAQ Index and thermal comfort index which could tell the users about the room's conditions. The results showed that the system is able to measure the level of air quality and successfully classify the sources influencing IAQ in various environments like ambient air, chemical presence, fragrance presence, foods and beverages and human activity.
    Matched MeSH terms: Air Pollution, Indoor
  2. Masitah Alias, Zaini Hamzah
    MyJurnal
    The growing concern over the workers safety and health has lead many factories and organizations do the air monitoring to ensure the airborne at their workplace is safe for the worker’s health and complying the Occupational Safety and Health Act 1994 (Act 514). In this study, the monitoring covers an indoor air quality and chemical exposure to the workers in one of the power plant repair shop. A few workers from different sections namely blasting, welding, grinding, fitting and maintenance area were chosen to assist in the personal monitoring for 8 hours measurement. PM10 were measured at a few sampling points to collect dusts for 24 hours duration. The samples were brought back to the laboratory for gravimetric and SEM-EDAX analysis. The results were certainly exceed the limit for air quality, and many elements were detected such as Fe, Ni, Al, Si, Ca, K, Ba, S, Cr, Zn and Cl. The present of these elements shows that exposure to these particulate matters is quite risky and some measure needs to be taken for remedial action.
    Matched MeSH terms: Air Pollution, Indoor
  3. Sakai N, Yamamoto S, Matsui Y, Khan MF, Latif MT, Ali Mohd M, et al.
    Sci Total Environ, 2017 May 15;586:1279-1286.
    PMID: 28236484 DOI: 10.1016/j.scitotenv.2017.02.139
    Volatile Organic Compounds (VOCs) in indoor air were investigated at 39 private residences in Selangor State, Malaysia to characterize the indoor air quality and to identify pollution sources. Twenty-two VOCs including isomers (14 aldehydes, 5 aromatic hydrocarbons, acetone, trichloroethylene and tetrachloroethylene) were collected by 2 passive samplers for 24h and quantitated using high performance liquid chromatography and gas chromatography mass spectrometry. Source profiling based on benzene/toluene ratio as well as statistical analysis (cluster analysis, bivariate correlation analysis and principal component analysis) was performed to identify pollution sources of the detected VOCs. The VOCs concentrations were compared with regulatory limits of air quality guidelines in WHO/EU, the US, Canada and Japan to clarify the potential health risks to the residents. The 39 residences were classified into 2 groups and 2 ungrouped residences based on the dendrogram in the cluster analysis. Group 1 (n=30) had mainly toluene (6.87±2.19μg/m3), formaldehyde (16.0±10.1μg/m3), acetaldehyde (5.35±4.57μg/m3) and acetone (11.1±5.95μg/m3) at background levels. Group 2 (n=7) had significantly high values of formaldehyde (99.3±10.7μg/m3) and acetone (35.8±12.6μg/m3), and a tendency to have higher values of acetaldehyde (23.7±13.5μg/m3), butyraldehyde (3.35±0.41μg/m3) and isovaleraldehyde (2.30±0.39μg/m3). The 2 ungrouped residences showed particularly high concentrations of BTX (benzene, toluene and xylene: 235μg/m3 in total) or acetone (133μg/m3). The geometric mean value of formaldehyde (19.2μg/m3) exceeded an 8-hour regulatory limit in Canada (9μg/m3), while those in other compounds did not exceed any regulatory limits, although a few residences exceeded at least one regulatory limit of benzene or acetaldehyde. Thus, the VOCs in the private residences were effectively characterized from the limited number of monitoring, and the potential health risks of the VOCs exposure, particularly formaldehyde, should be considered in the study area.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
  4. Ambu, Stephen, Chu, Wan-Loy, Mak, Joon-Wah, Wong, Shew-Fung, Chan, Li-Li, Wong, Siew-Tung
    MyJurnal
    Malaysia has good environmental laws to protect the outdoor environment and public health. However there are no laws governing indoor air quality (IAQ) and the knowledge among the public about its importance is also lacking. Environmental professionals think it is not a priority and this influences the policy decisions in the country. Therefore there is a need to create awareness by way of research, education and other promotional activities. What is much needed at this time is the establishment of standards for the conduct of risk assessment studies. To establish standards we need reliable data which can be used to develop appropriate guidelines for the purpose of mitigation and adaptation programmes. IAQ can have significant influence on health resulting in drop in productivity and economy of a country. It has been estimated that in the US, building related illnesses (BRI) symptoms have a relationship with decrease (3 to 5%) in work performance in an affected population resulting in an annual loss of US$60 billion in revenue. However, based on efficient management programmes they have also projected that the potential annual savings can be in the region of US$10 to 30 billion. This establishes that fact that good management programmes based on efficient guidelines is of economic value to a country and wellbeing of the population. The IMU has embarked on a research programme to collect the much-needed data for the framing of a good IAQ guideline for Malaysia.
    Matched MeSH terms: Air Pollution, Indoor
  5. Mariana A, Ho TM, Sofian-Azirun M, Wong AL
    PMID: 11414418
    Allergy to house dust mites (HDM) is an important cause of asthma and rhinitis in Malaysia. This study was carried out to evaluate the dust mite fauna in the Klang Valley. Dust samples were collected from 20 houses from March 1994 to February 1995. Thirty-three dust samples from mattresses were examined monthly for the occurrence of HDM. A total of 22 species in 9 families of HDM was identified. The most common and densely populated species was Blomia tropicalis with an average density of 8,934 mites/g of dust. Dermatophagoides pteronyssinus was the next in abundance, followed by Malayoglyphus intermedius. All houses surveyed were found to be infested with HDM and every house had at least 6 species of HDM. B. tropicalis and D. pteronyssinus were found in all mattresses. HDM in the Klang Valley were found to be highly prevalent and present in high densities. In this study, counts of D. pteronyssinus was found to exceed the proposed exposure threshold of 500 mites/g dust, for triggering acute asthma. Although counts of B. tropicalis exceeded D. pteronyssinus, no conclusion could be made because there is currently no exposure threshold for triggering acute asthma, for this species. Monthly distribution of B. tropicalis and D. pteronyssinus showed 2 peaks and 4 peaks, respectively. The major peak for D. pteronysinus was in January 1995 whereas for B. tropicalis, the major peak was more variable and occurred between November 1994 to January 1995. Both the species showed minor peak in April 1994.
    Matched MeSH terms: Air Pollution, Indoor
  6. Norbäck D, Hashim JH, Hashim Z, Cai GH, Sooria V, Ismail SA, et al.
    Sci Total Environ, 2017 Jan 15;577:148-154.
    PMID: 27802882 DOI: 10.1016/j.scitotenv.2016.10.148
    Few health studies exist on dampness and mould in schools in the tropics. We studied associations between fraction of exhaled nitric oxide (FeNO), respiratory symptoms and airway infections among students and dampness and fungal DNA in schools in Malaysia. A total of 368 randomly selected students from 32 classrooms in 8 secondary schools in Penang, Malaysia, participated (58% participation rate). Information on current respiratory symptoms and the home environment was collected by a standardised questionnaire. FeNO was measured by NIOX MINO (50ml/min). The classrooms were inspected and dust was collected by vacuuming on special filters and was analysed for five fungal DNA sequences by quantitative PCR. Linear mixed models and 3-level multiple logistic regression (school, classroom, student) were applied adjusting for demographic data and the home environment. Totally 10.3% reported doctor's diagnosed asthma, 15.1% current wheeze, 12.4% current asthma, 37.3% daytime breathlessness, 10.2% nocturnal breathlessness, 38.9% airway infections and 15.5% had pollen or furry pet allergy. The geometric mean of FeNO was 19.9ppb and 45% had elevated FeNO (>20ppb). Boys had higher levels of FeNO. Chinese had less daytime breathlessness than Malay (OR=0.30: p<0.001). Indoor carbon dioxide levels were low (380-720ppm). Dampness was observed in 18% of the classrooms and was associated with respiratory infections (OR=3.70; 95% CI 1.14-12.1) and FeNO (p=0.04). Aspergillus versicolor DNA was detected in 67% of the classrooms. Higher numbers of Aspergillus versicolor DNA in classroom dust were associated with wheeze (p=0.006), current asthma (p=0.002), respiratory infections (p=0.005) and elevated FeNO levels (p=0.02). In conclusion, respiratory symptoms were common among the students and the high FeNO levels indicate ongoing airway inflammation. Building dampness and the mould Aspergillus versicolor in schools in Malaysia can be risk factors for impaired respiratory health among the students.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
  7. Norbäck D, Hashim JH, Hashim Z, Sooria V, Ismail SA, Wieslander G
    Int J Hyg Environ Health, 2017 06;220(4):697-703.
    PMID: 28254266 DOI: 10.1016/j.ijheh.2017.01.016
    BACKGROUND: There are few studies on ocular effects of indoor mould exposure in schools, especially in the tropics OBJECTIVE: To study associations between eye symptoms and tear film break up time (BUT) in students and demographic data and fungal DNA in schools.

    METHODS: A school environment study was performed among randomly selected students in eight randomly selected secondary schools in Penang, Malaysia. Information on eye symptoms and demographic data was collected by a standardised questionnaire. BUT was measured by two methods, self-reported BUT (SBUT) and by the non-invasive Tearscope (NIBUT). Dust was collected by vacuuming in 32 classrooms and analysed for five fungal DNA sequences. Geometric mean (GM) for total fungal DNA was 7.31*104 target copies per gram dust and for Aspergillus/Penicillium DNA 3.34*104 target copies per gram dust. Linear mixed models and 3-level multiple logistic regression were applied adjusting for demographic factors.

    RESULTS: A total of 368 students (58%) participated and 17.4% reported weekly eye symptoms the last 3 months. The median SBUT and TBUT were 15 and 12s, respectively. Students wearing glasses (OR 2.41, p=0.01) and with a history of atopy (OR=2.67; p=0.008) had more eye symptoms. Girls had less eye symptoms than boys (OR=0.34; p=0.006) Indoor carbon dioxide in the classrooms was low (range 380-720ppm), temperature was 25-30°C and relative air humidity 70-88%. Total fungal DNA in vacuumed dust was associated with shorter SBUT (4s shorter per 105 target copies per gram dust; p=0.04) and NIBUT (4s shorter per 105 target copies per gram dust; p<0.001). Aspergillus/Penicillium DNA was associated with shorter NIBUT (5s shorter per 105 target copies per gram dust; p=0.01).

    CONCLUSION: Fungal contamination in schools in a tropical country can be a risk factor for impaired tear film stability among students.

    Matched MeSH terms: Air Pollution, Indoor/analysis*
  8. Abdullah S, Abd Hamid FF, Ismail M, Ahmed AN, Wan Mansor WN
    Data Brief, 2019 Aug;25:103969.
    PMID: 31198825 DOI: 10.1016/j.dib.2019.103969
    The aim of the measurement of this data is to evaluate the Indoor Air Quality (IAQ) in terms of chemical and physical parameters. Data were collected at three different kindergartens having different surrounding activities (industrial, institutional, residential area). The chemical parameters measured were respirable suspended particulates of PM10, PM2.5, PM1, carbon monoxide and carbon dioxide, and the concentrations are within the acceptable limit. Physical parameters of wind speed are within the standard, while temperature and relative humidity exceeded the acceptable limit. A strong correlation was found between the chemical IAQ parameters with thermal comfort parameters (temperature and relative humidity). The concentration of IAQ pollutants is higher in order of residential > institutional > industrial.
    Matched MeSH terms: Air Pollution, Indoor
  9. Tian Y
    J Health Popul Nutr, 2023 Nov 08;42(1):125.
    PMID: 37941052 DOI: 10.1186/s41043-023-00465-4
    The creation of a welcoming hospital atmosphere is necessary to improve patient wellbeing and encourage healing. The goal of this study was to examine the variables affecting hospitalised patients' comfort. The study procedure included a thorough search of the Web of Science and Scopus databases, as well as the use of software analytic tools to graphically map enormous literature data, providing a deeper understanding of the linkages within the literature and its changing patterns. Insights from a range of disciplines, including engineering, psychology, immunology, microbiology, and environmental science, were included into our study using content analysis and clustering approaches. The physical environment and the social environment are two crucial factors that are related to patient comfort. The study stress the need of giving patient comfort a top priority as they heal, especially by tackling indoor air pollution. Our research also emphasises how important hospital care and food guidelines are for improving patient comfort. Prioritising patients who need specialised care and attention, especially those who have suffered trauma, should be the focus of future study. Future research in important fields including trauma, communication, hospital architecture, and nursing will be built on the findings of this study. To enhance research in these crucial areas, worldwide collaboration between experts from other nations is also advised. Although many studies stress the significance of patient comfort, few have drawn conclusions from a variety of disciplines, including medicine, engineering, immunology, microbiology, and environmental science, the most crucial issue of thoroughly researching the improvement of patient comfort has not been addressed. Healthcare workers, engineers, and other professions will benefit greatly from this study's investigation of the connection between hospital indoor environments and patient comfort.
    Matched MeSH terms: Air Pollution, Indoor*
  10. Amir Abdullah, M.D., Leman, A.M., Norhidayah, A., Syafiq Syazwan, M.M.
    MyJurnal
    A poor Indoor Air Quality (IAQ) is a crucial problem which produces by the improper maintenance of Mechanical Ventilation and Air Conditioning (MVAC) ducting. A budget constraint intimidates for the practise of monitoring of the MVAC ducting. Thus IAQ measurements were conducted at the room where the air supplied by centralized air conditioning. It has been performed at four different offices that supply by two different Air Handling Unit (AHU). Walkthrough survey was conducted and the area samplings were selected for data collection. This paper examines the result of comparison of air ducting and air quality at academic office building, Universiti Tun Hussein Onn Malaysia (UTHM). The parameters involved were Temperature (°C), Relative Humidity (RH), Carbon Dioxide (CO2) and Carbon Monoxide (CO). Pictures were also captured to demonstrate the real conditions inside the ducting by using Mechanical Robot. Thus, duct cleaning was recommended to be an exceptional platform for the IAQ improvement.
    Matched MeSH terms: Air Pollution, Indoor
  11. Vilcins D, Christofferson RC, Yoon JH, Nazli SN, Sly PD, Cormier SA, et al.
    Ann Glob Health, 2024;90(1):9.
    PMID: 38312715 DOI: 10.5334/aogh.4363
    BACKGROUND: The United Nations has declared that humans have a right to clean air. Despite this, many deaths and disability-adjusted life years are attributed to air pollution exposure each year. We face both challenges to air quality and opportunities to improve, but several areas need to be addressed with urgency.

    OBJECTIVE: This paper summarises the recent research presented at the Pacific Basin Consortium for Environment and Health Symposium and focuses on three key areas of air pollution that are important to human health and require more research.

    FINDINGS AND CONCLUSION: Indoor spaces are commonly places of exposure to poor air quality and are difficult to monitor and regulate. Global climate change risks worsening air quality in a bi-directional fashion. The rising use of electric vehicles may offer opportunities to improve air quality, but it also presents new challenges. Government policies and initiatives could lead to improved air and environmental justice. Several populations, such as older people and children, face increased harm from air pollution and should become priority groups for action.

    Matched MeSH terms: Air Pollution, Indoor*
  12. Ismail B, Redzuwan Y, Chua RS, Shafiee W
    Appl Radiat Isot, 2001 Mar;54(3):393-7.
    PMID: 11214872
    The processing of amang (one of a number of tin-tailing products) for its valuable minerals has associated with the radiological and environmental problems. The processing and stockpiling of amang and ilmenite in open-air spaces, subject as it is to environmental influences, gives rise to a potential for affecting residents in adjacent area. A case study was carried out in a residential area neighbouring a typical amang plant to investigate the radiological impact to the residents. The average Effective Dose rates, calculated based on the contributions of Effective Dose rates from inhaled suspended radioactive dust, radon-thoron and their progeny, and external gamma radiation, were determined for selected houses. Results show that the occupants of those houses received Effective Dose rate, which cannot be differentiated from background. The major contributor to the average Effective Dose rate came from external radiation sources. Inhaled radon and its progeny was the second major contributor.
    Matched MeSH terms: Air Pollution, Indoor/adverse effects; Air Pollution, Indoor/analysis
  13. Abidin EZ, Hashim Z, Semple S
    Asian Pac J Cancer Prev, 2013;14(11):6845-50.
    PMID: 24377615
    BACKGROUND: This study was performed to gather data on second-hand smoke (SHS) concentrations in a range of public venues following the implementation of partial Smoke-Free Legislation in Malaysia in 2004.

    MATERIALS AND METHODS: PM2.5 was measured as a marker of SHS levels in a total of 61 restaurants, entertainment centres, internet cafes and pubs in Kuala Lumpur, Malaysia.

    RESULTS: Under the current smoke-free laws smoking was prohibited in 42 of the 61 premises. Active smoking was observed in nearly one-third (n=12) of these. For premises where smoking was prohibited and no active smoking observed, the mean (standard deviation) indoor PM2.5 concentration was 33.4 (23.8) μg/m3 compared to 187.1 (135.1) μg/m3 in premises where smoking was observed The highest mean PM2.5 was observed in pubs [361.5 (199.3) μg/m3].

    CONCLUSIONS: This study provides evidence of high levels of SHS across a range of hospitality venues, including about one-third of those where smoking is prohibited, despite 8 years of smoke-free legislation. Compliance with the legislation appeared to be particularly poor in entertainment centres and internet cafes. Workers and non-smoking patrons continue to be exposed to high concentrations of SHS within the hospitality industry in Malaysia and there is an urgent need for increased enforcement of existing legislation and consideration of more comprehensive laws to protect health.

    Matched MeSH terms: Air Pollution, Indoor/analysis*; Air Pollution, Indoor/legislation & jurisprudence; Air Pollution, Indoor/prevention & control
  14. Lee J, Lim S, Lee K, Guo X, Kamath R, Yamato H, et al.
    Int J Hyg Environ Health, 2010 Sep;213(5):348-51.
    PMID: 20542729 DOI: 10.1016/j.ijheh.2010.05.007
    Exposure to secondhand smoke (SHS) is a major threat to public health. Asian countries having the highest smoking prevalence are seriously affected by SHS. The objective of the study was to measure SHS levels in hospitality venues in seven Asian countries and to compare the SHS exposure to the levels in Western countries. The study was carried out in four types of related hospitality venues (restaurant, café, bar/club and entertainment) in China, India, Japan, Korea, Malaysia, Pakistan and Sri Lanka. Real-time measurement of particulate matter of <2.5microm aerodynamic diameter (PM(2.5)) was made during business hour using a handheld laser operated monitor. A total of 168 venues were measured in seven countries. The average indoor PM(2.5) level was 137microg/m(3), ranging from 46microg/m(3) in Malaysia to 207microg/m(3) in India. Bar/club had the highest PM(2.5) level of 191microg/m(3) and restaurants had the lowest PM(2.5) level of 92microg/m(3). The average indoor PM(2.5) level in smoking venues was 156micro/m(3), which was 3.6 times higher than non-smoking venues (43microg/m(3)). Indoor PM(2.5) levels were significantly associated with country, type of venue, smoking density and air exchange rate (p<0.05). In the seven Asian countries, PM(2.5) levels were high due to SHS in public places. The current levels are comparable to the levels in Western countries before the adoption of smoke-free policy. Since Asian country has high prevalence of SHS in public places, there is an urgent need for comprehensive smoke-free regulation in Asian countries.
    Matched MeSH terms: Air Pollution, Indoor/analysis; Air Pollution, Indoor/statistics & numerical data*
  15. Ibrahim F, Samsudin EZ, Ishak AR, Sathasivam J
    Front Public Health, 2022;10:1067764.
    PMID: 36424957 DOI: 10.3389/fpubh.2022.1067764
    Indoor air quality (IAQ) has recently gained substantial traction as the airborne transmission of infectious respiratory disease becomes an increasing public health concern. Hospital indoor environments are complex ecosystems and strategies to improve hospital IAQ require greater appreciation of its potentially modifiable determinants, evidence of which are currently limited. This mini-review updates and integrates findings of previous literature to outline the current scientific evidence on the relationship between hospital IAQ and building design, building operation, and occupant-related factors. Emerging evidence has linked aspects of building design (dimensional, ventilation, and building envelope designs, construction and finishing materials, furnishing), building operation (ventilation operation and maintenance, hygiene maintenance, access control for hospital users), and occupants' characteristics (occupant activities, medical activities, adaptive behavior) to hospital IAQ. Despite the growing pool of IAQ literature, some important areas within hospitals (outpatient departments) and several key IAQ elements (dimensional aspects, room configurations, building materials, ventilation practices, adaptive behavior) remain understudied. Ventilation for hospitals continues to be challenging, as elevated levels of carbon monoxide, bioaerosols, and chemical compounds persist in indoor air despite having mechanical ventilation systems in place. To curb this public health issue, policy makers should champion implementing hospital IAQ surveillance system for all areas of the hospital building, applying interdisciplinary knowledge during the hospital design, construction and operation phase, and training of hospital staff with regards to operation, maintenance, and building control manipulation. Multipronged strategies targeting these important determinants are believed to be a viable strategy for the future control and improvement of hospital IAQ.
    Matched MeSH terms: Air Pollution, Indoor*
  16. Chong KC, Lai SO, Lau WJ, Thiam HS, Ismail AF, Roslan RA
    Polymers (Basel), 2018 Jan 28;10(2).
    PMID: 30966162 DOI: 10.3390/polym10020126
    Air pollution is a widely discussed topic amongst the academic and industrial spheres as it can bring adverse effects to human health and economic loss. As humans spend most of their time at the office and at home, good indoor air quality with enriched oxygen concentration is particularly important. In this study, polysulfone (PSF) hollow fiber membranes fabricated by dry-jet wet phase inversion method were coated by a layer of polydimethylsiloxane (PDMS) or poly(ether block amide) (PEBAX) at different concentrations and used to evaluate their performance in gas separation for oxygen enrichment. The surface-coated membranes were characterized using SEM and EDX to determine the coating layer thickness and surface chemical properties, respectively. Results from the gas permeation study revealed that the PSF membrane coated with PDMS offered higher permeance and selectivity compared to the membrane coated with PEBAX. The best performing PDMS-coated membrane demonstrated oxygen and nitrogen gas permeance of 18.31 and 4.01 GPU, respectively with oxygen/nitrogen selectivity of 4.56. Meanwhile, the PEBAX-coated membrane only showed 12.23 and 3.11 GPU for oxygen and nitrogen gas, respectively with a selectivity of 3.94. It can be concluded the PDMS coating is more promising for PSF hollow fiber membrane compared to the PEBAX coating for the oxygen enrichment process.
    Matched MeSH terms: Air Pollution, Indoor
  17. Jeevananthan C, Muhamad NA, Jaafar MH, Hod R, Ab Ghani RM, Md Isa Z, et al.
    BMJ Open, 2020 11 04;10(11):e039623.
    PMID: 33148753 DOI: 10.1136/bmjopen-2020-039623
    INTRODUCTION: The current global pandemic of the virus that emerged from Hubei province in China has caused coronavirus disease in 2019 (COVID-19), which has affected a total number of 900 036 people globally, involving 206 countries and resulted in a cumulative of 45 693 deaths worldwide as of 3 April 2020. The mode of transmission is identified through airdrops from patients' body fluids such as during sneezing, coughing and talking. However, the relative importance of environmental effects in the transmission of the virus has not been vastly studied. In addition, the role of temperature and humidity in air-borne transmission of infection is presently still unclear. This study aims to identify the effect of temperature, humidity and air quality in the transmission of SARS-CoV-2.

    METHODS AND ANALYSIS: We will systematically conduct a comprehensive literature search using various databases including PubMed, EMBASE, Scopus, CENTRAL and Google Scholar to identify potential studies. The search will be performed for any eligible articles from the earliest published articles up to latest available studies in 2020. We will include all the observational studies such as cohort case-control and cross-sectional studies that explains or measures the effects of temperature and/or humidity and/or air quality and/or anthropic activities that is associated with SARS-CoV-2. Study selection and reporting will follow the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and Meta-Analysis of Observational Studies in Epidemiology guideline. All data will be extracted using a standardised data extraction form and quality of the studies will be assessed using the Newcastle-Ottawa Scale guideline. Descriptive and meta-analysis will be performed using a random effect model in Review Manager File.

    ETHICS AND DISSEMINATION: No primary data will be collected, and thus no formal ethical approval is required. The results will be disseminated through a peer-reviewed publication and conference presentation.

    PROSPERO REGISTRATION NUMBER: CRD42020176756.

    Matched MeSH terms: Air Pollution, Indoor
  18. Yue X, Ma NL, Sonne C, Guan R, Lam SS, Van Le Q, et al.
    J Hazard Mater, 2021 03 05;405:124138.
    PMID: 33092884 DOI: 10.1016/j.jhazmat.2020.124138
    Indoor air pollution with toxic volatile organic compounds (VOCs) and fine particulate matter (PM2.5) is a threat to human health, causing cancer, leukemia, fetal malformation, and abortion. Therefore, the development of technologies to mitigate indoor air pollution is important to avoid adverse effects. Adsorption and photocatalytic oxidation are the current approaches for the removal of VOCs and PM2.5 with high efficiency. In this review we focus on the recent development of indoor air pollution mitigation materials based on adsorption and photocatalytic decomposition. First, we review on the primary indoor air pollutants including formaldehyde, benzene compounds, PM2.5, flame retardants, and plasticizer: Next, the recent advances in the use of adsorption materials including traditional biochar and MOF (metal-organic frameworks) as the new emerging porous materials for VOCs absorption is reviewed. We review the mechanism for mitigation of VOCs using biochar (noncarbonized organic matter partition and adsorption) and MOF together with parameters that affect indoor air pollution removal efficiency based on current mitigation approaches including the mitigation of VOCs using photocatalytic oxidation. Finally, we bring forward perspectives and directions for the development of indoor air mitigation technologies.
    Matched MeSH terms: Air Pollution, Indoor
  19. Syazwan A, Rafee BM, Hafizan J, Azman A, Nizar A, Izwyn Z, et al.
    PMID: 22570579 DOI: 10.2147/RMHP.S26567
    To meet the current diversified health needs in workplaces, especially in nonindustrial workplaces in developing countries, an indoor air quality (IAQ) component of a participatory occupational safety and health survey should be included.
    Matched MeSH terms: Air Pollution, Indoor
  20. Shoffian Amin Jaafar, Suhaily Amran, Mohd Norhafsham Maghpor, Ahmad Sayuti Zainal, Nurzuhairah Jamil, Naemah Tajul Arus, et al.
    MyJurnal
    Indoor air quality is a term which refers to the air quality in and around buildings and structures, in which it
    is related to the health and comfort of those who are in the building. The study aims to identify the relationship
    between environmental factors with microbe growth by investigating the concentration of airborne bacteria and
    fungi at National Institute of Occupational Safety and Health (NIOSH) and to determine whether indoor bacteria and
    fungi concentration were associated with environmental factors such as temperature relative humidity and carbon
    dioxide concentration. This research was conducted concurrently with indoor air quality sampling as per requirement
    under the Malaysian Code of Practice of Indoor Air Quality (COP IAQ). The COP IAQ requires minimum of one
    sample to be taken from each area. If an area consists of a few separated rooms, each room is sampled and measured
    independently. Also this approach was used to determine whether there is a difference of indoor bacteria and fungi
    in different microenvironments. Results show that there is a significant correlation between humidity and bacteria
    concentration and fungi concentration; and between temperature and bacteria concentration. However, there is no
    significant correlation between temperature and fungi concentration. This study has also established significant
    difference on bacteria concentration and fungi concentration between microenvironments.
    Matched MeSH terms: Air Pollution, Indoor
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links