Displaying publications 1 - 20 of 75 in total

Abstract:
Sort:
  1. Suppian R, Vegandraj S, Kandaiya S
    Int J Rad Appl Instrum A, 1992 Jul;43(7):937-8.
    PMID: 1321104
    Pumping air through a soft tissue which acts as a membrane is a relatively easy and quick method to collect and measure radon/thoron and its daughter nuclides in air. Analysis of the activity of the radionuclides can be calculated using an alpha counter which has been calibrated. In this method the activity of radon/thoron cannot be separated from the activity of radionuclides already present in the aerosol or dust particles.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
  2. Azizi BHO, Zulkifli HI, Kasim S
    J Asthma, 1995;32(6):413-8.
    PMID: 7592244 DOI: 10.3109/02770909409077752
    We performed a hospital-based study to examine a hypothesis that indoor air pollution was associated with acute asthma in young children living in Kuala Lumpur City. A total of 158 children aged 1 month to 5 years hospitalized for the first time for asthma were recruited as cases. Controls were 201 children of the same age group who were hospitalized for causes other than a respiratory illness. Information was obtained from mothers using a standardized questionnaire. Univariate analysis identified two indoor pollution variables as significant factors. Sharing a bedroom with an adult smoker and exposure to mosquito coil smoke at least three nights in a week were both associated with increased risk for asthma. Logistic regression analysis confirmed that sharing a bedroom with an adult smoker (OR = 1.91, 95% CI 1.13, 3.21) and exposure to mosquito coil smoke (OR = 1.73, 95% CI 1.02, 2.93) were independent risk factors. Other factors independently associated with acute asthma were previous history of allergy, history of asthma in first-degree relatives, low birth weight, and the presence of a coughing sibling. There was no association between asthma and exposure to kerosene stove, wood stove, aerosol mosquito repellent, type of housing, or crowding. We conclude that indoor air pollution is an avoidable factor in the increasing morbidity due to asthma in children in a tropical environment.
    Matched MeSH terms: Air Pollution, Indoor/adverse effects*
  3. Choo, C.M., Quah, B.S., Rostenberghe, H.V., Choo, K.E.
    MyJurnal
    A case control study was conducted to identify the risk factors for acute lower respiratory tract infections (ALRI) in hospitalised children in Kelantan. One hun-dred and twenty children aged one month to five years hospitalised for ALRI were matched by age with 120 children as controls. Data on demography and expo-sure to putative risk factors were collected by interview-ing parents or caretakers. Anthropometric measure-ments were also carried out to assess the nutritional sta-tus of the children. For each risk factor studied, the odds ratios for exposure and disease were calculated by using univariate analysis followed by multiple logistic regression analysis to determine those factors which remained significant.
    The presence of sibling(s) who coughed at home (OR 12.1, 95% CI 5.2-28.1), crowding in bedroom (OR 4.4, 95% CI 2.1-9.0), weight-for-age < 3rd percentile (OR 9.0, 95% CI 3.1-25.8), lack of breast feeding (OR 9.4, 95% CI 2.3-38.4) and incomplete immunisation (OR 4.5, 95% CI 1.7-12.1) were significant indepen-dent risk factors for ALRI. Other factors like poverty, maternal education level, male sex, low birth weight, history of atopy, family history of asthma and indoor air pollution were not associated with an increased risk of ALRI.
    This study showed that poor nutritional status, inap-propriate child care practices and poor living conditions, particularly those related to crowding, predispose to ALRI in Kelantanese children necessitating hospital admission. A change in these factors may reduce the morbidity and mortality of childhood ALRI in Kelantan.
    Matched MeSH terms: Air Pollution, Indoor
  4. Mariana A, Ho TM, Sofian-Azirun M, Wong AL
    PMID: 11414418
    Allergy to house dust mites (HDM) is an important cause of asthma and rhinitis in Malaysia. This study was carried out to evaluate the dust mite fauna in the Klang Valley. Dust samples were collected from 20 houses from March 1994 to February 1995. Thirty-three dust samples from mattresses were examined monthly for the occurrence of HDM. A total of 22 species in 9 families of HDM was identified. The most common and densely populated species was Blomia tropicalis with an average density of 8,934 mites/g of dust. Dermatophagoides pteronyssinus was the next in abundance, followed by Malayoglyphus intermedius. All houses surveyed were found to be infested with HDM and every house had at least 6 species of HDM. B. tropicalis and D. pteronyssinus were found in all mattresses. HDM in the Klang Valley were found to be highly prevalent and present in high densities. In this study, counts of D. pteronyssinus was found to exceed the proposed exposure threshold of 500 mites/g dust, for triggering acute asthma. Although counts of B. tropicalis exceeded D. pteronyssinus, no conclusion could be made because there is currently no exposure threshold for triggering acute asthma, for this species. Monthly distribution of B. tropicalis and D. pteronyssinus showed 2 peaks and 4 peaks, respectively. The major peak for D. pteronysinus was in January 1995 whereas for B. tropicalis, the major peak was more variable and occurred between November 1994 to January 1995. Both the species showed minor peak in April 1994.
    Matched MeSH terms: Air Pollution, Indoor
  5. Ismail B, Redzuwan Y, Chua RS, Shafiee W
    Appl Radiat Isot, 2001 Mar;54(3):393-7.
    PMID: 11214872
    The processing of amang (one of a number of tin-tailing products) for its valuable minerals has associated with the radiological and environmental problems. The processing and stockpiling of amang and ilmenite in open-air spaces, subject as it is to environmental influences, gives rise to a potential for affecting residents in adjacent area. A case study was carried out in a residential area neighbouring a typical amang plant to investigate the radiological impact to the residents. The average Effective Dose rates, calculated based on the contributions of Effective Dose rates from inhaled suspended radioactive dust, radon-thoron and their progeny, and external gamma radiation, were determined for selected houses. Results show that the occupants of those houses received Effective Dose rate, which cannot be differentiated from background. The major contributor to the average Effective Dose rate came from external radiation sources. Inhaled radon and its progeny was the second major contributor.
    Matched MeSH terms: Air Pollution, Indoor/adverse effects; Air Pollution, Indoor/analysis
  6. Liu W, Zhang J, Hashim JH, Jalaludin J, Hashim Z, Goldstein BD
    Environ Health Perspect, 2003 Sep;111(12):1454-60.
    PMID: 12948883
    Burning mosquito coils indoors generates smoke that can control mosquitoes effectively. This practice is currently used in numerous households in Asia, Africa, and South America. However, the smoke may contain pollutants of health concern. We conducted the present study to characterize the emissions from four common brands of mosquito coils from China and two common brands from Malaysia. We used mass balance equations to determine emission rates of fine particles (particulate matter < 2.5 microm in diameter; PM(2.5)), polycyclic aromatic hydrocarbons (PAHs), aldehydes, and ketones. Having applied these measured emission rates to predict indoor concentrations under realistic room conditions, we found that pollutant concentrations resulting from burning mosquito coils could substantially exceed health-based air quality standards or guidelines. Under the same combustion conditions, the tested Malaysian mosquito coils generated more measured pollutants than did the tested Chinese mosquito coils. We also identified a large suite of volatile organic compounds, including carcinogens and suspected carcinogens, in the coil smoke. In a set of experiments conducted in a room, we examined the size distribution of particulate matter contained in the coil smoke and found that the particles were ultrafine and fine. The findings from the present study suggest that exposure to the smoke of mosquito coils similar to the tested ones can pose significant acute and chronic health risks. For example, burning one mosquito coil would release the same amount of PM(2.5) mass as burning 75-137 cigarettes. The emission of formaldehyde from burning one coil can be as high as that released from burning 51 cigarettes.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
  7. Assunta M, Fields N, Knight J, Chapman S
    Tob Control, 2004 Dec;13 Suppl 2:ii4-12.
    PMID: 15564219
    STUDY OBJECTIVE: To review the tobacco industry's Asian environmental tobacco smoke (ETS) consultants programme, focusing on three key nations: China, Hong Kong, and Malaysia.
    METHODS: Systematic keyword and opportunistic website searches of formerly private internal industry documents.
    MAIN RESULTS: The release of the 1986 US Surgeon General's report on second hand smoke provoked tobacco companies to prepare for a major threat to their industry. Asian programme activities included conducting national/international symposiums, consultant "road shows" and extensive lobbying and media activities. The industry exploited confounding factors said to be unique to Asian societies such as diet, culture and urban pollution to downplay the health risks of ETS. The industry consultants were said to be "..prepared to do the kinds of things they were recruited to do".
    CONCLUSIONS: The programme was successful in blurring the science on ETS and keeping the controversy alive both nationally and internationally. For the duration of the project, it also successfully dissuaded national policy makers from instituting comprehensive bans on smoking in public places.
    Matched MeSH terms: Air Pollution, Indoor/adverse effects
  8. Rohani A, Zamree I, Lim LH, Rahini H, David L, Kamilan D
    PMID: 17333767
    The bioefficacy of indoor residual-sprayed deltamethrin wettable granule (WG) formulation at 25 mg a.i./m2 and 20 mg a.i./m2 for the control of malaria was compared with the current dose of 20 mg/m2 deltamethrin wettable powder (WP) in aboriginal settlements in Kuala Lipis, Pahang, Malaysia. The malaria vector has been previously identified as Anopheles maculatus. The assessment period for the 20 mg/m2 dosage was six months, but for the 25 mg/m2 dosage, the period was 9 months. Collections of mosquitoes using the bare-leg techniques were carried out indoors and outdoors from 7:00 PM to 7:00 AM. All mosquitoes were dissected for sporozoites and parity. Larval collections were carried out at various locations to assess the extent and distribution of breeding of vectors. A high incidence of human feeds was detected during May 2005 and a low incidence during January 2005 for all the study areas. Our study showed that deltamethrin WG at 25 mg/m2 suppressed An. maculatus biting activity. More An. maculatus were caught in outdoor landing catches than indoor landing catches for all the study areas. The results indicate that 25 mg/m2 WG is good for controlling malaria for up to 9 months. Where residual spraying is envisaged, the usual two spraying cycles per year with 20 mg/m2 deltamethrin may be replaced with 25 mg/m2 deltamethrin WG every 9 months.
    Matched MeSH terms: Air Pollution, Indoor
  9. Goh JC, Juliana J, Malina O, Ngah ZU, Norhafizalena O
    Trop Biomed, 2007 Jun;24(1):37-46.
    PMID: 17568376 MyJurnal
    Indoor fungal reservoirs, particularly airborne Penicillium species, were identified throughout the ventilation system of the building and dissemination of fungi from those reservoirs was found to be occurring all the time. The objectives of this study were to determine the association between air concentration of indoor mould (Penicillium) and allergy symptoms among office workers. The study design used in this research was a cross-sectional study. Risk factors were identified through the questionnaire survey. Office workers were selected based on the proximity of their workstations to the microbiological air sampler used for the mould sampling. Results from the current study suggests that individual susceptibility of exposed subjects might be influenced by several factors associated with mould exposure; for example, inhaled mycotoxins or volatile organic compounds, which may, in some complex way, affect the immune response. This study provides the much needed preliminary baseline data for developing guidelines with validated findings that will be of use for policy decisions in Malaysia regarding indoor air quality. Results from this study are recommended for use in planning and implementing control measures in order to reduce the exposure to indoor mould and promote healthy working environment among the workers.
    Matched MeSH terms: Air Pollution, Indoor/adverse effects*
  10. Masitah Alias, Zaini Hamzah
    MyJurnal
    The growing concern over the workers safety and health has lead many factories and organizations do the air monitoring to ensure the airborne at their workplace is safe for the worker’s health and complying the Occupational Safety and Health Act 1994 (Act 514). In this study, the monitoring covers an indoor air quality and chemical exposure to the workers in one of the power plant repair shop. A few workers from different sections namely blasting, welding, grinding, fitting and maintenance area were chosen to assist in the personal monitoring for 8 hours measurement. PM10 were measured at a few sampling points to collect dusts for 24 hours duration. The samples were brought back to the laboratory for gravimetric and SEM-EDAX analysis. The results were certainly exceed the limit for air quality, and many elements were detected such as Fe, Ni, Al, Si, Ca, K, Ba, S, Cr, Zn and Cl. The present of these elements shows that exposure to these particulate matters is quite risky and some measure needs to be taken for remedial action.
    Matched MeSH terms: Air Pollution, Indoor
  11. Abdul Rahman HI, Shah SA, Alias H, Ibrahim HM
    Asian Pac J Cancer Prev, 2008 Oct-Dec;9(4):649-52.
    PMID: 19256754
    BACKGROUND: In Malaysia, acute leukemia is the most common cancer among children below the age of 15. A case-control study was here conducted for cases from the Klang Valley, Malaysia, who received treatment at the National University of Malaysia Hospital (HUKM) and Kuala Lumpur General Hospital (GHKL). The main objective was to determine any association with environmental factors.

    METHODS: Case subjects were children aged below 15 years and diagnosed with acute leukemia in HUKM and GHKL between January 1, 2001 and May 30, 2007. Control subjects were children aged below 15 years who were diagnosed with any non-cancerous acute illnesses in these hospitals. A total of 128 case subjects and 128 control subjects were enrolled in this study. The information was collected using a structured questionnaire and a global positioning system (GPS) device. All factors were analyzed using unmatched logistic regression.

    RESULTS: The analysis showed that the occurrence of acute leukemia among children was strongly determined by the following factors: family income (odds ratio (OR) 0.19, 95% confidence interval (CI): 0.09-0.42), father with higher social contact (OR 7.61, 95% CI: 3.78-15.4), number of elder siblings (OR 0.36, 95% CI: 0.18-0.77), father who smokes (OR 2.78, 95% CI: 1.49-5.16), and the distance of the house from a power line (OR 2.30, 95% CI: 1.18-4.49).

    CONCLUSIONS: Some socioeconomic, demographic, and environmental factors are strong predictors of the occurrence of acute leukemia among children in Klang Valley, Malaysia. In terms of environmental factors, it is recommended that future housing areas should be developed at least 200 m away from power lines.
    Matched MeSH terms: Air Pollution, Indoor/statistics & numerical data*
  12. Ambu, Stephen, Chu, Wan-Loy, Mak, Joon-Wah, Wong, Shew-Fung, Chan, Li-Li, Wong, Siew-Tung
    MyJurnal
    Malaysia has good environmental laws to protect the outdoor environment and public health. However there are no laws governing indoor air quality (IAQ) and the knowledge among the public about its importance is also lacking. Environmental professionals think it is not a priority and this influences the policy decisions in the country. Therefore there is a need to create awareness by way of research, education and other promotional activities. What is much needed at this time is the establishment of standards for the conduct of risk assessment studies. To establish standards we need reliable data which can be used to develop appropriate guidelines for the purpose of mitigation and adaptation programmes. IAQ can have significant influence on health resulting in drop in productivity and economy of a country. It has been estimated that in the US, building related illnesses (BRI) symptoms have a relationship with decrease (3 to 5%) in work performance in an affected population resulting in an annual loss of US$60 billion in revenue. However, based on efficient management programmes they have also projected that the potential annual savings can be in the region of US$10 to 30 billion. This establishes that fact that good management programmes based on efficient guidelines is of economic value to a country and wellbeing of the population. The IMU has embarked on a research programme to collect the much-needed data for the framing of a good IAQ guideline for Malaysia.
    Matched MeSH terms: Air Pollution, Indoor
  13. Edimansyah BA, Rusli BN, Naing L, Azwan BA, Aziah BD
    PMID: 19323052
    The purpose of this study was to determine the indoor air quality (IAQ) status of an automotive assembly plant in Rawang, Selangor, Malaysia using selected IAQ parameters, such as carbon dioxide (CO2), carbon monoxide (CO), temperature, relative humidity (RH) and respirable particulate matter (PM10). A cross-sectional study was conducted in the paint shop and body shop sections of the plant in March 2005. The Q-TRAK Plus IAQ Monitor was used to record the patterns of CO, CO2, RH and temperature; whilst PM10 was measured using DUSTTRAK Aerosol Monitor over an 8-hour time weight average (8-TWA). It was found that the average temperatures, RH and PM10 in the paint shop section and body shop sections exceeded the Department of Safety and Health (DOSH) standards. The average concentrations of RH and CO were slightly higher in the body shop section than in the paint shop section, while the average concentrations of temperature and CO2 were slightly higher in the paint shop section than in the body shop section. There was no difference in the average concentrations of PM10 between the two sections.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
  14. Mirmohammadi M, Hakimi Ibrahim M, Ahmad A, Kadir MO, Mohammadyan M, Mirashrafi SB
    Environ Monit Assess, 2010 Jun;165(1-4):341-7.
    PMID: 19444630 DOI: 10.1007/s10661-009-0950-5
    Today, many raw materials used in factories may have a dangerous effect on the physiological system of workers. One of them which is widely used in the polyurethane factories is diisocyanates. These compounds are widely used in surface coatings, polyurethane foams, adhesives, resins, elastomers, binders, and sealants. Exposure to diisocyanates causes irritation to the skin, mucous membranes, eyes, and respiratory tract. Hexamethylene diamine (HDA) is metabolite of hexamethylene diisocyanate (HDI). It is an excretory material by worker's urine who is exposed to HDI. Around 100 air samples were collected from five defined factories by midget impinger which contained dimethyl sulfoxide absorbent as a solvent and tryptamine as reagent. Samples were analyzed by high-performance liquid chromatography with EC\UV detector using NIOSH 5522 method of sampling. Also, 50 urine samples collected from workers were also analyzed using William's biological analysis method. The concentration of HDI into all air samples were more than 88 microg/m(3), and they have shown high concentration of pollutant in the workplaces in comparison with NIOSH standard, and all of the workers' urine were contaminated by HDA. The correlation and regression test were used to obtain statistical model for HDI and HDA, which is useful for the prediction of diisocyanates pollution situation in the polyurethane factories.
    Matched MeSH terms: Air Pollution, Indoor*
  15. Lee J, Lim S, Lee K, Guo X, Kamath R, Yamato H, et al.
    Int J Hyg Environ Health, 2010 Sep;213(5):348-51.
    PMID: 20542729 DOI: 10.1016/j.ijheh.2010.05.007
    Exposure to secondhand smoke (SHS) is a major threat to public health. Asian countries having the highest smoking prevalence are seriously affected by SHS. The objective of the study was to measure SHS levels in hospitality venues in seven Asian countries and to compare the SHS exposure to the levels in Western countries. The study was carried out in four types of related hospitality venues (restaurant, café, bar/club and entertainment) in China, India, Japan, Korea, Malaysia, Pakistan and Sri Lanka. Real-time measurement of particulate matter of <2.5microm aerodynamic diameter (PM(2.5)) was made during business hour using a handheld laser operated monitor. A total of 168 venues were measured in seven countries. The average indoor PM(2.5) level was 137microg/m(3), ranging from 46microg/m(3) in Malaysia to 207microg/m(3) in India. Bar/club had the highest PM(2.5) level of 191microg/m(3) and restaurants had the lowest PM(2.5) level of 92microg/m(3). The average indoor PM(2.5) level in smoking venues was 156micro/m(3), which was 3.6 times higher than non-smoking venues (43microg/m(3)). Indoor PM(2.5) levels were significantly associated with country, type of venue, smoking density and air exchange rate (p<0.05). In the seven Asian countries, PM(2.5) levels were high due to SHS in public places. The current levels are comparable to the levels in Western countries before the adoption of smoke-free policy. Since Asian country has high prevalence of SHS in public places, there is an urgent need for comprehensive smoke-free regulation in Asian countries.
    Matched MeSH terms: Air Pollution, Indoor/analysis; Air Pollution, Indoor/statistics & numerical data*
  16. Al-Shamiry, Faisal Mohammed Seif, Desa Ahmad
    MyJurnal
    Natural ventilation is defined as the number of air exchanges per hour per unit floor area necessary
    to reduce high indoor air temperature and humidity. In addition, it maintains the concentration of carbon dioxide. Natural ventilation is preferred in mechanical system as the ventilation opening is built into the greenhouse, with lower construction cost and no energy and maintenance inputs are required. A mathematical model to quantify natural ventilation rates was developed and verified in large-scale greenhouse structures. For this purpose, four Naturally Ventilated Tropical Greenhouse Structures were designed and constructed at the Malaysian Agricultural Research and Development Institute (MARDI). These were single, double, triple, and quadruple span structures with floor areas of 500 m2, 1000 m2, 1500 m2 and 2000 m2, respectively. This paper presents the validation of a mathematical model which was developed to quantify natural ventilation rates which are very crucial to reduce high in-house temperature built up in the tropics. Regression equations of natural ventilation against wind speed were found to be Φw = 0.0632V, Φw= 0.0395V, Φw= 0.0316Vand Φw=0.0276V for the single, double, triple and quadruple spans, respectively. Meanwhile, coefficients of determination showed strong relationships between ventilation rate and wind speed, with R2 = 0.9999 for all structures. Larger floor area was found to have higher in-house temperature than smaller ones. Ventilation rate inside the single-span structure was found to be higher compared to the multi-span structures, which increased linearly with the increasing wind speed at the eaves of structure.
    Matched MeSH terms: Air Pollution, Indoor
  17. Cai GH, Hashim JH, Hashim Z, Ali F, Bloom E, Larsson L, et al.
    Pediatr Allergy Immunol, 2011 May;22(3):290-7.
    PMID: 21457336 DOI: 10.1111/j.1399-3038.2010.01127.x
    While there is a large variation of prevalence of asthma symptoms worldwide, what we do know is that it is on the rise in developing countries. However, there are few studies on allergens, moulds and mycotoxin exposure in schools in tropical countries. The aims were to measure selected fungal DNA, furry pet allergens and mycotoxins in dust samples from schools in Malaysia and to study associations with pupils' respiratory health effects. Eight secondary schools and 32 classrooms in Johor Bahru, Malaysia were randomly selected. A questionnaire with standardized questions was used for health assessment in 15 randomly selected pupils from each class. The school buildings were inspected and both indoor and outdoor climate were measured. Dust samples were collected by cotton swabs and Petri dishes for fungal DNA, mycotoxins and allergens analysis. The participation rate was 96% (462/480 invited pupils), with a mean age of 14 yr (range 14-16). The pupils mostly reported daytime breathlessness (41%), parental asthma or allergy (22%), pollen or pet allergy (21%) and doctor-diagnosed asthma (13%) but rarely reported night-time breathlessness (7%), asthma in the last 12 months (3%), medication for asthma (4%) or smoking (5%). The inspection showed that no school had any mechanical ventilation system, but all classrooms had openable windows that were kept open during lectures. The mean building age was 16 yr (range 3-40) and the mean indoor and outdoor CO(2) levels were 492 ppm and 408 ppm, respectively. The mean values of indoor and outdoor temperature and relative humidity were the same, 29°C and 70% respectively. In cotton swab dust samples, the Geometric Mean (GM) value for total fungal DNA and Aspergillus/Penicillium (Asp/Pen) DNA in swab samples (Cell Equivalents (CE)/m(2)) was 5.7*10(8) and 0.5*10(8), respectively. The arithmetic mean (CE/m(2)) for Aspergillus versicolor DNA was 8780, Stachybotrys chartarum DNA was 26 and Streptomyces DNA was 893. The arithmetic means (pg/m(2)) for the mycotoxins sterigmatocystin and verrucarol were 2547 and 17, respectively. In Petri dish dust samples, the GM value for total fungal DNA and Asp/Pen DNA (CE/m(2) per day) was 9.2*10(6) and 1.6*10(6), respectively. The arithmetic mean (CE/m(2) per day) for A. versicolor DNA was 1478, S. chartarum DNA was 105 and Streptomyces DNA was 1271, respectively. The GM value for cat (Fel d1) allergen was 5.9 ng/m(2) per day. There were positive associations between A. versicolor DNA, wheeze and daytime breathlessness and between Streptomyces DNA and doctor-diagnosed asthma. However, the associations were inverse between S. chartarum DNA and daytime breathlessness and between verrucarol and daytime breathlessness. In conclusion, fungal DNA and cat allergen contamination were common in schools from Malaysia and there was a high prevalence of respiratory symptoms among pupils. Moreover, there were associations between levels of some fungal DNA and reported respiratory health in the pupils.
    Matched MeSH terms: Air Pollution, Indoor/analysis
  18. Jie Y, Ismail NH, Jie X, Isa ZM
    J Formos Med Assoc, 2011 Sep;110(9):555-63.
    PMID: 21930065 DOI: 10.1016/j.jfma.2011.07.003
    This review summarizes the results of epidemiological studies focusing on the detrimental effects of home environmental factors on asthma morbidity in adults. We reviewed the literature on indoor air quality (IAQ), physical and sociodemographic factors, and asthma morbidity in homes, and identified commonly reported asthma, allergic, and respiratory symptoms involving the home environment. Reported IAQ and asthma morbidity data strongly indicated positive associations between indoor air pollution and adverse health effects in most studies. Indoor factors most consistently associated with asthma and asthma-related symptoms in adults included fuel combustion, mold growth, and environmental tobacco smoke. Environmental exposure may increase an adult's risk of developing asthma and also may increase the risk of asthma exacerbations. Evaluation of present IAQ levels, exposure characteristics, and the role of exposure to these factors in relation to asthma morbidity is important for improving our understanding, identifying the burden, and for developing and implementing interventions aimed at reducing asthma morbidity.
    Matched MeSH terms: Air Pollution, Indoor/adverse effects*
  19. Latif MT, Baharudin NH, Velayutham P, Awang N, Hamdan H, Mohamad R, et al.
    Environ Monit Assess, 2011 Oct;181(1-4):479-89.
    PMID: 21181256 DOI: 10.1007/s10661-010-1843-3
    The renovation of a building will certainly affect the quality of air in the vicinity of where associated activities were undertaken, this includes the quality of air inside the building. Indoor air pollutants such as particulate matter, heavy metals, and fine fibers are likely to be emitted during renovation work. This study was conducted to determine the concentration of heavy metals, asbestos and suspended particulates in the Biology Building, at the Universiti Kebangsaan, Malaysia (UKM). Renovation activities were carried out widely in the laboratories which were located in this building. A low-volume sampler was used to collect suspended particulate matter of a diameter size less than 10 μm (PM₁₀) and an air sampling pump, fitted with a cellulose ester membrane filter, were used for asbestos sampling. Dust was collected using a small brush and scope. The concentration of heavy metals was determined through the use of inductively coupled plasma-mass spectroscopy and the fibers were counted through a phase contrast microscope. The concentrations of PM₁₀ recorded in the building during renovation action (ranging from 166 to 542 μg m⁻³) were higher than the value set by the Department of Safety and Health for respirable dust (150 μg m⁻³). Additionally, they were higher than the value of PM₁₀ recorded in indoor environments from other studies. The composition of heavy metals in PM₁₀ and indoor dust were found to be dominated by Zn and results also showed that the concentration of heavy metals in indoor dust and PM₁₀ in this study was higher than levels recorded in other similar studies. The asbestos concentration was 0.0038 ± 0.0011 fibers/cc. This was lower than the value set by the Malaysian Department of Occupational, Safety and Health (DOSH) regulations of 0.1 fibers/cc, but higher than the background value usually recorded in indoor environments. This study strongly suggests that renovation issues need to be considered seriously by relevant stakeholders within the university in order to ensure that the associated risks toward humans and indoor environment are eliminated, or where this is not feasible, minimized as far as possible.
    Matched MeSH terms: Air Pollution, Indoor/statistics & numerical data*
  20. Nor Mohd Razif Noraini, Leman, A.M., Ahmad Sayuti Zainal Abidin
    MyJurnal
    A preliminary study has been conducted in a new constructed 8 stories building (2 level of Hostels facility, 3 level of Training Room, 2 Level of Offices and 1 level of Exhibition Halls and Rooms) in Bandar Baru Bangi, Selangor. The Hostels facility is a floor tile and furnished with build in locker and use split air conditioning system while the Training Room and Exhibition Rooms used floor tile. The Offices and Exhibition Hall are carpeted furnished. All these spaces were using centralized air conditioning systems. A pre-commissioning assessment on 5 chemical parameters of indoor air pollutants such Total Volatile Organic Compounds (TVOC), Formaldehyde, Respirable Particulates (PM!
    Matched MeSH terms: Air Pollution, Indoor
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links