Displaying publications 1 - 20 of 76 in total

Abstract:
Sort:
  1. Norbäck D, Hashim JH, Hashim Z, Ali F
    Sci Total Environ, 2017 Aug 15;592:153-160.
    PMID: 28319702 DOI: 10.1016/j.scitotenv.2017.02.215
    This paper studied associations between volatile organic compounds (VOC), formaldehyde, nitrogen dioxide (NO2) and carbon dioxide (CO2) in schools in Malaysia and rhinitis, ocular, nasal and dermal symptoms, headache and fatigue among students. Pupils from eight randomly selected junior high schools in Johor Bahru, Malaysia (N=462), participated (96%). VOC, formaldehyde and NO2 were measured by diffusion sampling (one week) and VOC also by pumped air sampling during class. Associations were calculated by multi-level logistic regression adjusting for personal factors, the home environment and microbial compounds in the school dust. The prevalence of weekly rhinitis, ocular, throat and dermal symptoms were 18.8%, 11.6%, 15.6%, and 11.1%, respectively. Totally 20.6% had weekly headache and 22.1% fatigue. Indoor CO2 were low (range 380-690 ppm). Indoor median NO2 and formaldehyde concentrations over one week were 23μg/m3 and 2.0μg/m3, respectively. Median indoor concentration of toluene, ethylbenzene, xylene, and limonene over one week were 12.3, 1.6, 78.4 and 3.4μg/m3, respectively. For benzaldehyde, the mean indoor concentration was 2.0μg/m3 (median<1μg/m3). Median indoor levels during class of benzene and cyclohexane were 4.6 and 3.7μg/m3, respectively. NO2 was associated with ocular symptoms (p<0.001) and fatigue (p=0.01). Formaldehyde was associated with ocular (p=0.004), throat symptoms (p=0.006) and fatigue (p=0.001). Xylene was associated with fatigue (p<0.001) and benzaldehyde was associated with headache (p=0.03). In conclusion, xylene, benzaldehyde, formaldehyde and NO2 in schools can be risk factors for ocular and throat symptoms and fatigue among students in Malaysia. The indoor and outdoor levels of benzene were often higher than the EU standard of 5μg/m3.
    Matched MeSH terms: Air Pollution, Indoor/adverse effects*
  2. Sui, Sien Leong, Lihan, Samuel, Hwa, Chuan Chia
    MyJurnal
    The abuse of antibiotics usage in bird industry has resulted in the emerging antibiotic resistant Enterococci worldwide which has posed a threat clinically to human health. The present study was to screen and identify the potential virulence agents in antibiotic resistance E. faecalis in bird industry in Borneo. Enterococcus bacteria collected from the birds’ faeces and indoor air inside ten birdhouses were identified to species level and their antibiotic resistance was checked using antibiotic susceptibility discs. Specific primers using PCR assay were intended for the detection of four potential virulence genes (ace, AS, efaA, gelE). Out of the thirty-seven Enterococci faecal bacteria, the prevailing bacteria found were Enterococcus qallinacum (51%), Enterococcus faecalis (35%) and Enterococcus harae (8%). The airborne bacteria were reported as Enterococcus faecalis (5%) and Enterococcus qallinacum (1%). Twenty-seven percent of isolates were reported to have Multiple Antibiotic Resistance (MAR) index ≥ 0.2 with 9 distinct resistance patterns formed. E. faecalis showed higher resistance to vancomycin. Virulence genes were successfully reported in the 15 E. faecalis isolates. Sixty-seven percent of isolates were detected positive for four virulence genes, 27% possessed three (AS, efaA, gelE) genes and 6% possessed two (ace, AS) genes. Antibiotic resistance and virulence genes detection were significantly correlated. These virulence genes or antibiotic resistance genes were important in the pathogenesis of E. faecalis infections.
    Matched MeSH terms: Air Pollution, Indoor
  3. Nur Azfahani Ahmad, Zuraihana Ahmad Zawawi, Nazhatulzalkis Jamaludin, Khairulliza Ahmad Salleh
    Jurnal Inovasi Malaysia, 2019;2(2):55-70.
    MyJurnal
    A 1984 World Health Organization (WHO) Committee report highlighted that up to 30 per cent of buildings may have to face problems related to Indoor Air Quality (IAQ). Insufficient ventilation will lead to stagnant air and can cause stuffiness in buildings. This will then leads to a bigger problem, known as the Sick Building Syndrome (SBS). It is important to note that sick building syndrome may cause various illnesses including allergies, acute respiration problem, feeling of discomfort and other psychological impacts. The “Ventilation Flow Evaluation System for Sustainable Housing Development” is a PC-based database tool developed to access and measure ventilation flow in a new or remodelled building in order to prevent or mitigate this problem. The purpose of the system is to provide resources for building designers in solving Indoor Air Quality (IAQ) issues especially related to ventilation flow based on regulations provided in Malaysian Standard (MS 1525). The system will allow readily building plan to be measured and analysed based on ventilation data collected at site, in order to allow buildings to obtain healthy and sufficient air for breathing and comfort purposes. The system will also recommend suitable layout plan in the building to meet the ventilation purposes, namely cross-ventilation and stack-effect ventilation.
    Matched MeSH terms: Air Pollution, Indoor
  4. Vilcins D, Christofferson RC, Yoon JH, Nazli SN, Sly PD, Cormier SA, et al.
    Ann Glob Health, 2024;90(1):9.
    PMID: 38312715 DOI: 10.5334/aogh.4363
    BACKGROUND: The United Nations has declared that humans have a right to clean air. Despite this, many deaths and disability-adjusted life years are attributed to air pollution exposure each year. We face both challenges to air quality and opportunities to improve, but several areas need to be addressed with urgency.

    OBJECTIVE: This paper summarises the recent research presented at the Pacific Basin Consortium for Environment and Health Symposium and focuses on three key areas of air pollution that are important to human health and require more research.

    FINDINGS AND CONCLUSION: Indoor spaces are commonly places of exposure to poor air quality and are difficult to monitor and regulate. Global climate change risks worsening air quality in a bi-directional fashion. The rising use of electric vehicles may offer opportunities to improve air quality, but it also presents new challenges. Government policies and initiatives could lead to improved air and environmental justice. Several populations, such as older people and children, face increased harm from air pollution and should become priority groups for action.

    Matched MeSH terms: Air Pollution, Indoor*
  5. Yap HS, Roberts AC, Luo C, Tan Z, Lee EH, Thach TQ, et al.
    Indoor Air, 2021 11;31(6):2239-2251.
    PMID: 34096640 DOI: 10.1111/ina.12863
    Space is a resource that is constantly being depleted, especially in mega-cities. Underground workspaces (UGS) are increasingly being included in urban plans and have emerged as an essential component of vertical cities. While progress had been made on the engineering aspects associated with the development of high-quality UGS, public attitudes toward UGS as work environments (ie, the public's design concerns with UGS) are relatively unknown. Here, we present the first large-scale study examining preferences and attitudes toward UGS, surveying close to 2000 participants from four cities in three continents (Singapore, Shanghai, London, and Montreal). Contrary to previous beliefs, air quality (and not lack of windows) is the major concern of prospective occupants. Windows, temperature, and lighting emerged as additional important building performance aspects for UGS. Early adopters (ie, individuals more willing to accept UGS and thus more likely to be the first occupants) across all cities prioritized air quality. Present results suggest that (perceived) air quality is a key building performance aspect for UGS that needs to be communicated to prospective occupants as this will improve their attitudes and views toward UGS. This study highlights the importance of indoor air quality for the public.
    Matched MeSH terms: Air Pollution, Indoor*
  6. Othman M, Latif MT, Matsumi Y
    Ecotoxicol Environ Saf, 2019 Apr 15;170:739-749.
    PMID: 30583285 DOI: 10.1016/j.ecoenv.2018.12.042
    It is important to assess indoor air quality in school classrooms where the air quality may significantly influence school children's health and performance. This study aims to determine the concentrations of PM2.5 and dust chemical compositions in indoor and outdoor school classroom located in Kuala Lumpur City Centre. The PM2.5 concentration was measured from 19th September 2017-16th February 2018 using an optical PM2.5 sensor. Indoor and outdoor dust was also collected from the school classrooms and ion and trace metal concentrations were analysed using ion chromatography (IC) and inductively couple plasma-mass spectrometry (ICP-MS) respectively. This study showed that the average indoor and outdoor 24 h PM2.5 was 11.2 ± 0.45 µg m-3 and 11.4 ± 0.44 µg m-3 respectively. The 8 h PM2.5 concentration ranged between 3.2 and 28 µg m-3 for indoor and 3.2 and 19 µg m-3 for outdoor classrooms. The highest ion concentration in indoor dust was Ca2+ with an average concentration of 38.5 ± 35.0 µg g-1 while for outdoor dust SO42- recorded the highest ion concentration with an average concentration of 30.6 ± 9.37 µg g-1. Dominant trace metals in both indoor and outdoor dust were Al, Fe and Zn. Principle component analysis-multiple linear regression (PCA-MLR) demonstrated that the major source of indoor dust was road dust (69%), while soil dominated the outdoor dust (74%). Health risk assessment showed that the hazard quotient (HQ) value for non-carcinogenic trace metals was indoor and outdoor dust through dermal and inhalation pathways, but not the ingestion pathway. This study suggests indoor contributions of PM2.5 concentrations are due to the activities of the school children while the compositions of indoor and outdoor dust are greatly influenced by the soil/earth source plus industrial and traffic contribution.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
  7. Ooi SS, Mak JW, Chen DK, Ambu S
    Ind Health, 2017 Feb 07;55(1):35-45.
    PMID: 27476379 DOI: 10.2486/indhealth.2015-0218
    The free-living protozoan Acanthamoeba is an opportunistic pathogen that is ubiquitous in our environment. However, its role in affecting indoor air quality and ill-health of indoor occupants is relatively unknown. The present study investigated the presence of Acanthamoeba from the ventilation system and its correlation with other indoor air quality parameters, used in the industry code of practice and its potential as an indicator for indoor air quality. Indoor air quality assessments were carried out in nine commercial buildings with approval from the building management, and the parameters assessed were as recommended by the Department of Occupational Safety and Health. The presence of Acanthamoeba was determined through dust swabs from the ventilation system and indoor furniture. Logistic regression was performed to study the correlation between assessed parameters and occupants' complaints. A total of 107 sampling points were assessed and 40.2% of the supplying air diffuser and blowing fan and 15% of the furniture were positive for cysts. There was a significant correlation between Acanthamoeba detected from the ventilation system with ambient total fungus count (r=0.327; p=0.01) and respirable particulates (r=0.276; p=0.01). Occupants' sick building syndrome experience also correlated with the presence of Acanthamoeba in the ventilation system (r=0.361; p=0.01) and those detected on the furniture (r=0.290; p=0.01). Logistic regression showed that there was a five-fold probability of sick building syndrome among occupants when Acanthamoeba was detected in the ventilation system.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
  8. Khoshnava SM, Rostami R, Mohamad Zin R, Štreimikienė D, Mardani A, Ismail M
    PMID: 32290074 DOI: 10.3390/ijerph17072589
    Conventional building materials (CBMs) made from non-renewable resources are the main source of indoor air contaminants, whose impact can extend from indoors to outdoors. Given their sustainable development (SD) prospect, green building materials (GBMs) with non-toxic, natural, and organic compounds have the potential to reduce their overall impacts on environmental and human health. In this regard, biocomposites as GBMs are environmentally friendly, safe, and recyclable materials and their replacement of CBMs reduces environmental impacts and human health concerns. This study aims to develop a model of fully hybrid bio-based biocomposite as non-structural GBMs and compare it with fully petroleum-based composite in terms of volatile organic compound (VOC) emissions and human health impacts. Using a small chamber test (American Society for Testing and Materials (ASTM)-D5116) for VOC investigation and SimaPro software modeling with the ReCiPe method for evaluating human health impacts. Life cycle assessment (LCA) methodology is used, and the results indicate that switching the fully hybrid bio-based biocomposite with the fully petroleum-based composite could reduce more than 50% impacts on human health in terms of indoor and outdoor. Our results indicate that the usage of biocomposite as GBMs can be an environmentally friendly solution for reducing the total indoor and outdoor impacts on human health.
    Matched MeSH terms: Air Pollution, Indoor*
  9. Mohd Isa KN, Hashim Z, Jalaludin J, Lung Than LT, Hashim JH
    PMID: 32731346 DOI: 10.3390/ijerph17155413
    BACKGROUND: To explore the inflammation phenotypes following indoor pollutants exposure based on marker expression on eosinophils and neutrophils with the application of chemometric analysis approaches.

    METHODS: A cross-sectional study was undertaken among secondary school students in eight suburban and urban schools in the district of Hulu Langat, Selangor, Malaysia. The survey was completed by 96 students at the age of 14 by using the International Study of Asthma and Allergies in Children (ISAAC) and European Community Respiratory Health Survey (ECRHS) questionnaires. The fractional exhaled nitric oxide (FeNO) was measured, and an allergic skin prick test and sputum induction were performed for all students. Induced sputum samples were analysed for the expression of CD11b, CD35, CD63, and CD66b on eosinophils and neutrophils by flow cytometry. The particulate matter (PM2.5 and PM10), NO2, CO2, and formaldehyde were measured inside the classrooms.

    RESULTS: Chemometric and regression results have clustered the expression of CD63 with PM2.5, CD11b with NO2, CD66b with FeNO levels, and CO2 with eosinophils, with the prediction accuracy of the models being 71.88%, 76.04%, and 76.04%, respectively. Meanwhile, for neutrophils, the CD63 and CD66b clustering with PM2.5 and CD11b with FeNO levels showed a model prediction accuracy of 72.92% and 71.88%, respectively.

    CONCLUSION: The findings indicated that the exposure to PM2.5 and NO2 was likely associated with the degranulation of eosinophils and neutrophils, following the activation mechanisms that led to the inflammatory reactions.

    Matched MeSH terms: Air Pollution, Indoor/statistics & numerical data*
  10. Mohamad N, Latif MT, Khan MF
    Ecotoxicol Environ Saf, 2016 Feb;124:351-362.
    PMID: 26590697 DOI: 10.1016/j.ecoenv.2015.11.002
    This study aimed to investigate the chemical composition and potential sources of PM10 as well as assess the potential health hazards it posed to school children. PM10 samples were taken from classrooms at a school in Kuala Lumpur's city centre (S1) and one in the suburban city of Putrajaya (S2) over a period of eight hours using a low volume sampler (LVS). The composition of the major ions and trace metals in PM10 were then analysed using ion chromatography (IC) and inductively coupled plasma-mass spectrometry (ICP-MS), respectively. The results showed that the average PM10 concentration inside the classroom at the city centre school (82µg/m(3)) was higher than that from the suburban school (77µg/m(3)). Principal component analysis-absolute principal component scores (PCA-APCS) revealed that road dust was the major source of indoor PM10 at both school in the city centre (36%) and the suburban location (55%). The total hazard quotient (HQ) calculated, based on the formula suggested by the United States Environmental Protection Agency (USEPA), was found to be slightly higher than the acceptable level of 1, indicating that inhalation exposure to particle-bound non-carcinogenic metals of PM10, particularly Cr exposure by children and adults occupying the school environment, was far from negligible.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
  11. Lim FL, Hashim Z, Md Said S, Than LT, Hashim JH, Norbäck D
    Sci Total Environ, 2015 Dec 1;536:353-61.
    PMID: 26225741 DOI: 10.1016/j.scitotenv.2015.06.137
    There are few studies on sick building syndrome (SBS) including clinical measurements for atopy and fractional exhaled nitric oxide (FeNO). Our aim was to study associations between SBS symptoms, selected personal factors, office characteristics and indoor office exposures among office workers from a university in Malaysia. Health data were collected by a questionnaire (n=695), skin prick test (SPT) (n=463) and FeNO test (n=460). Office settled dust was vacuumed and analyzed for endotoxin, (1,3)-β-glucan and house dust mites (HDM) allergens group 1 namely Dermatophagoides pteronyssinus (Der p 1) and Dermatophagoides farinae (Der f 1). Office indoor temperature, relative air humidity (RH), carbon monoxide (CO) and carbon dioxide (CO2) were measured by a direct reading instrument. Associations were studied by two-levels multiple logistic regression with mutual adjustment and stratified analysis. The prevalence of weekly dermal, mucosal and general symptoms was 11.9%, 16.0% and 23.0% respectively. A combination of SPT positivity (allergy to HDM or cat) and high FeNO level (≥25 ppb) was associated with dermal (p=0.002), mucosal (p<0.001) and general symptoms (p=0.05). Der f1 level in dust was associated with dermal (p<0.001), mucosal (p<0.001) and general (p=0.02) symptoms. Among those with allergy to D. farinae, associations were found between Der f 1 levels in dust and dermal (p=0.003), mucosal (p=0.001) and general symptoms (p=0.007). Office-related symptoms were associated with Der f 1 levels in dust (p=0.02), low relative air humidity (p=0.04) and high office temperature (p=0.05). In conclusion, a combination of allergy to cat or HDM and high FeNO is a risk factor for SBS symptoms. Der f 1 allergen in dust can be a risk factor for SBS in the office environment, particularly among those sensitized to Der f 1 allergen.
    Matched MeSH terms: Air Pollution, Indoor/analysis*; Air Pollution, Indoor/statistics & numerical data
  12. Lee J, Lim S, Lee K, Guo X, Kamath R, Yamato H, et al.
    Int J Hyg Environ Health, 2010 Sep;213(5):348-51.
    PMID: 20542729 DOI: 10.1016/j.ijheh.2010.05.007
    Exposure to secondhand smoke (SHS) is a major threat to public health. Asian countries having the highest smoking prevalence are seriously affected by SHS. The objective of the study was to measure SHS levels in hospitality venues in seven Asian countries and to compare the SHS exposure to the levels in Western countries. The study was carried out in four types of related hospitality venues (restaurant, café, bar/club and entertainment) in China, India, Japan, Korea, Malaysia, Pakistan and Sri Lanka. Real-time measurement of particulate matter of <2.5microm aerodynamic diameter (PM(2.5)) was made during business hour using a handheld laser operated monitor. A total of 168 venues were measured in seven countries. The average indoor PM(2.5) level was 137microg/m(3), ranging from 46microg/m(3) in Malaysia to 207microg/m(3) in India. Bar/club had the highest PM(2.5) level of 191microg/m(3) and restaurants had the lowest PM(2.5) level of 92microg/m(3). The average indoor PM(2.5) level in smoking venues was 156micro/m(3), which was 3.6 times higher than non-smoking venues (43microg/m(3)). Indoor PM(2.5) levels were significantly associated with country, type of venue, smoking density and air exchange rate (p<0.05). In the seven Asian countries, PM(2.5) levels were high due to SHS in public places. The current levels are comparable to the levels in Western countries before the adoption of smoke-free policy. Since Asian country has high prevalence of SHS in public places, there is an urgent need for comprehensive smoke-free regulation in Asian countries.
    Matched MeSH terms: Air Pollution, Indoor/analysis; Air Pollution, Indoor/statistics & numerical data*
  13. Abidin EZ, Hashim Z, Semple S
    Asian Pac J Cancer Prev, 2013;14(11):6845-50.
    PMID: 24377615
    BACKGROUND: This study was performed to gather data on second-hand smoke (SHS) concentrations in a range of public venues following the implementation of partial Smoke-Free Legislation in Malaysia in 2004.

    MATERIALS AND METHODS: PM2.5 was measured as a marker of SHS levels in a total of 61 restaurants, entertainment centres, internet cafes and pubs in Kuala Lumpur, Malaysia.

    RESULTS: Under the current smoke-free laws smoking was prohibited in 42 of the 61 premises. Active smoking was observed in nearly one-third (n=12) of these. For premises where smoking was prohibited and no active smoking observed, the mean (standard deviation) indoor PM2.5 concentration was 33.4 (23.8) μg/m3 compared to 187.1 (135.1) μg/m3 in premises where smoking was observed The highest mean PM2.5 was observed in pubs [361.5 (199.3) μg/m3].

    CONCLUSIONS: This study provides evidence of high levels of SHS across a range of hospitality venues, including about one-third of those where smoking is prohibited, despite 8 years of smoke-free legislation. Compliance with the legislation appeared to be particularly poor in entertainment centres and internet cafes. Workers and non-smoking patrons continue to be exposed to high concentrations of SHS within the hospitality industry in Malaysia and there is an urgent need for increased enforcement of existing legislation and consideration of more comprehensive laws to protect health.

    Matched MeSH terms: Air Pollution, Indoor/analysis*; Air Pollution, Indoor/legislation & jurisprudence; Air Pollution, Indoor/prevention & control
  14. Sasnila Pakpahan, Bambang Wispriyono, Budi Hartono, Juliana Jalaludin
    MyJurnal
    Introduction: School environment represents an important microenvironment for students who spend 6-8 hours in classrooms. Indoor air quality is linked to several respiratory diseases in the school age group. This research aims to study indoor air quality of schools at different environmental characteristic and assess its health risks to students. Methods: This research measured air quality (PM2.5, PM10, CO2 , and HCHO) in three junior high schools and followed by health risk assessment. Results: This research found that the mean or median level of indoor PM2.5 and PM10 in all three schools exceeded the standard value with health risks (HQ> 1) for PM2.5 in all three schools and PM10 in two schools. Whereas carbon dioxide and formaldehyde concentrations were still safe and did not inflict health risks (HQ < 1). The scenario for managing the health risk of PM2.5 and PM10 exposure was to control the exposure at a safe threshold of PM2.5 0.035 mg/m3 ; 0.043 mg/m3 and PM10 0.144 mg/m3 for most of the population at normal school time. Conclusion: It was concluded that the level of indoor particulate matters indicates poor indoor air quality in all three schools at different environmental characteristic and inflicts health risk on students so that the health risk management is required.
    Matched MeSH terms: Air Pollution, Indoor
  15. Choo, C.M., Quah, B.S., Rostenberghe, H.V., Choo, K.E.
    MyJurnal
    A case control study was conducted to identify the risk factors for acute lower respiratory tract infections (ALRI) in hospitalised children in Kelantan. One hun-dred and twenty children aged one month to five years hospitalised for ALRI were matched by age with 120 children as controls. Data on demography and expo-sure to putative risk factors were collected by interview-ing parents or caretakers. Anthropometric measure-ments were also carried out to assess the nutritional sta-tus of the children. For each risk factor studied, the odds ratios for exposure and disease were calculated by using univariate analysis followed by multiple logistic regression analysis to determine those factors which remained significant.
    The presence of sibling(s) who coughed at home (OR 12.1, 95% CI 5.2-28.1), crowding in bedroom (OR 4.4, 95% CI 2.1-9.0), weight-for-age < 3rd percentile (OR 9.0, 95% CI 3.1-25.8), lack of breast feeding (OR 9.4, 95% CI 2.3-38.4) and incomplete immunisation (OR 4.5, 95% CI 1.7-12.1) were significant indepen-dent risk factors for ALRI. Other factors like poverty, maternal education level, male sex, low birth weight, history of atopy, family history of asthma and indoor air pollution were not associated with an increased risk of ALRI.
    This study showed that poor nutritional status, inap-propriate child care practices and poor living conditions, particularly those related to crowding, predispose to ALRI in Kelantanese children necessitating hospital admission. A change in these factors may reduce the morbidity and mortality of childhood ALRI in Kelantan.
    Matched MeSH terms: Air Pollution, Indoor
  16. Norbäck D, Hashim JH, Hashim Z, Cai GH, Sooria V, Ismail SA, et al.
    Sci Total Environ, 2017 Jan 15;577:148-154.
    PMID: 27802882 DOI: 10.1016/j.scitotenv.2016.10.148
    Few health studies exist on dampness and mould in schools in the tropics. We studied associations between fraction of exhaled nitric oxide (FeNO), respiratory symptoms and airway infections among students and dampness and fungal DNA in schools in Malaysia. A total of 368 randomly selected students from 32 classrooms in 8 secondary schools in Penang, Malaysia, participated (58% participation rate). Information on current respiratory symptoms and the home environment was collected by a standardised questionnaire. FeNO was measured by NIOX MINO (50ml/min). The classrooms were inspected and dust was collected by vacuuming on special filters and was analysed for five fungal DNA sequences by quantitative PCR. Linear mixed models and 3-level multiple logistic regression (school, classroom, student) were applied adjusting for demographic data and the home environment. Totally 10.3% reported doctor's diagnosed asthma, 15.1% current wheeze, 12.4% current asthma, 37.3% daytime breathlessness, 10.2% nocturnal breathlessness, 38.9% airway infections and 15.5% had pollen or furry pet allergy. The geometric mean of FeNO was 19.9ppb and 45% had elevated FeNO (>20ppb). Boys had higher levels of FeNO. Chinese had less daytime breathlessness than Malay (OR=0.30: p<0.001). Indoor carbon dioxide levels were low (380-720ppm). Dampness was observed in 18% of the classrooms and was associated with respiratory infections (OR=3.70; 95% CI 1.14-12.1) and FeNO (p=0.04). Aspergillus versicolor DNA was detected in 67% of the classrooms. Higher numbers of Aspergillus versicolor DNA in classroom dust were associated with wheeze (p=0.006), current asthma (p=0.002), respiratory infections (p=0.005) and elevated FeNO levels (p=0.02). In conclusion, respiratory symptoms were common among the students and the high FeNO levels indicate ongoing airway inflammation. Building dampness and the mould Aspergillus versicolor in schools in Malaysia can be risk factors for impaired respiratory health among the students.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
  17. Lim FL, Hashim Z, Than LTL, Md Said S, Hashim JH, Norbäck D
    Int J Tuberc Lung Dis, 2019 11 01;23(11):1171-1177.
    PMID: 31718753 DOI: 10.5588/ijtld.18.0668
    OBJECTIVE: To examine the associations between endotoxin and (1,3)-β-glucan concentrations in office dust and respiratory symptoms and airway inflammation among 695 office workers in Malaysia.METHODS: Health data were collected using a questionnaire, sensitisation testing and measurement of fractional exhaled nitric oxide (FeNO). Indoor temperature, relative air humidity (RH) and carbon dioxide (CO₂) were measured in the offices and settled dust was vacuumed and analysed for endotoxin and (1,3)-β-glucan concentrations. Associations were analysed by two level multiple logistic regression.RESULTS: Overall, 9.6% of the workers had doctor-diagnosed asthma, 15.5% had wheeze, 18.4% had daytime attacks of breathlessness and 25.8% had elevated FeNO (≥25 ppb). The median levels in office dust were 11.3 EU/mg endotoxin and 62.9 ng/g (1,3)-β-glucan. After adjusting for personal and home environment factors, endotoxin concentration in dust was associated with wheeze (P = 0.02) and rhinoconjunctivitis (P = 0.007). The amount of surface dust (P = 0.04) and (1,3)-β-glucan concentration dust (P = 0.03) were associated with elevated FeNO.CONCLUSION: Endotoxin in office dust could be a risk factor for wheeze and rhinoconjunctivitis among office workers in mechanically ventilated offices in a tropical country. The amount of dust and (1,3)-β-glucan (a marker of indoor mould exposure) were associated with Th2 driven airway inflammation.
    Matched MeSH terms: Air Pollution, Indoor/analysis
  18. Abdullah Mohd Noh, Nordin Ayoub, Siti Zurina Mat Noor, Norhafizah Zahari, Mardhiyati Mohd Yunus
    MyJurnal
    Radon exists naturally in the air. It can accumulate inside the buildings which may affect the indoor air quality. Radon is a radioactive gas that produces alpha particles during decay time. The alpha particles might cause harm to the human lungs and stomach. Inhalation of radon is one of the causes of lung cancer disease. Samples of inhaled radon in different rooms at the workplace were taken hourly through a passive diffusion chamber. The detection method was done using Alpha Spectrometry. The short term measurement was applied in the study to monitor the average weekly radon reading in different rooms in the Medical Imaging Laboratory of the University of Selangor (UNISEL). All tested rooms showed the existence of radon gas with different concentrations. Some of them showed the maximum reading of radon concentration which was higher than the radon action level of 148Bq/m3 or 4pCi/l. Their weekly average of radon concentration is contributing almost 50% of the accumulated radon concentration in the laboratory. It is highly recommended that monitoring the concentration of radon in indoor air is performed to ensure it is at a safe and healthy level.
    Matched MeSH terms: Air Pollution, Indoor
  19. Ismail B, Redzuwan Y, Chua RS, Shafiee W
    Appl Radiat Isot, 2001 Mar;54(3):393-7.
    PMID: 11214872
    The processing of amang (one of a number of tin-tailing products) for its valuable minerals has associated with the radiological and environmental problems. The processing and stockpiling of amang and ilmenite in open-air spaces, subject as it is to environmental influences, gives rise to a potential for affecting residents in adjacent area. A case study was carried out in a residential area neighbouring a typical amang plant to investigate the radiological impact to the residents. The average Effective Dose rates, calculated based on the contributions of Effective Dose rates from inhaled suspended radioactive dust, radon-thoron and their progeny, and external gamma radiation, were determined for selected houses. Results show that the occupants of those houses received Effective Dose rate, which cannot be differentiated from background. The major contributor to the average Effective Dose rate came from external radiation sources. Inhaled radon and its progeny was the second major contributor.
    Matched MeSH terms: Air Pollution, Indoor/adverse effects; Air Pollution, Indoor/analysis
  20. Goh JC, Juliana J, Malina O, Ngah ZU, Norhafizalena O
    Trop Biomed, 2007 Jun;24(1):37-46.
    PMID: 17568376 MyJurnal
    Indoor fungal reservoirs, particularly airborne Penicillium species, were identified throughout the ventilation system of the building and dissemination of fungi from those reservoirs was found to be occurring all the time. The objectives of this study were to determine the association between air concentration of indoor mould (Penicillium) and allergy symptoms among office workers. The study design used in this research was a cross-sectional study. Risk factors were identified through the questionnaire survey. Office workers were selected based on the proximity of their workstations to the microbiological air sampler used for the mould sampling. Results from the current study suggests that individual susceptibility of exposed subjects might be influenced by several factors associated with mould exposure; for example, inhaled mycotoxins or volatile organic compounds, which may, in some complex way, affect the immune response. This study provides the much needed preliminary baseline data for developing guidelines with validated findings that will be of use for policy decisions in Malaysia regarding indoor air quality. Results from this study are recommended for use in planning and implementing control measures in order to reduce the exposure to indoor mould and promote healthy working environment among the workers.
    Matched MeSH terms: Air Pollution, Indoor/adverse effects*