Displaying publications 1 - 20 of 24 in total

Abstract:
Sort:
  1. Treasure T, Austin C, Kenny LA, Pepper J
    Curr Opin Cardiol, 2022 Nov 01;37(6):454-458.
    PMID: 36094493 DOI: 10.1097/HCO.0000000000000990
    PURPOSE OF REVIEW: To bring together and annotate publications about personalised external aortic root support reported in the 18 months preceding submission.

    RECENT FINDINGS: The total number of personalised external aortic root support (PEARS) operations is now approaching 700 in 30 centres in Australia, Belgium, Brazil, Czech Republic, Great Britain, Greece, Ireland, Malaysia, Netherlands, New Zealand, Poland and Slovakia. There are continued reports of stability of aortic dimensions and aortic valve function with the only exceptions known being where the surgeon has deviated from the instructions for use of the device. The median root diameter of Marfan patients having PEARS was 47 mm suggesting that the existing criterion of 50 mm is due for reconsideration. The peri-operative mortality currently estimated to be less than 0.3%. The first recipient remains alive and well after 18 years. The use of PEARS as an adjunct to the Ross operation to support the pulmonary autograft is being explored in several centres.

    SUMMARY: The operation requires proctoring and adherence to a strict operative protocol and with those precautions excellent results are attained. The evidence and opinions provided in the cited publications indicate that PEARS is a proven and successful prophylactic operation for aortic root aneurysm.

    Matched MeSH terms: Autografts
  2. Murugan K, Faisham WI, Zulmi W
    Malays Orthop J, 2021 Mar;15(1):93-99.
    PMID: 33880154 DOI: 10.5704/MOJ.2103.014
    Introduction: Mega endoprosthesis replacement for resection of primary malignant bone tumour requires immediate and long-term stability, particularly in the young and active patient. Extracortical bone bridge interface (EBBI) is a technique whereby autograft is wrapped around the interface junction of bone and porous-coated implant to induce and enhance bone formation for biological incorporation. This procedure increases the mean torsional stiffness and the mean maximum torque, which eventually improves the implant's long-term survival.

    Material and methods: The extracortical bone bridge interface's radiological parameter was evaluated at the prosthesis bone junction two years after surgery utilising a picture archiving and communication system (PACS). The radiograph's anteroposterior and lateral view was analysed for both thickness and length in all four cortices. The analysis was done in SPSS Version 24 using One-Way ANOVA and independent T-Test. Results were presented as mean and standard deviation and considered significant when the p-value was < 0.05.

    Results: The mean average thickness was 2.2293mm (SD 1.829), and the mean average length was 31.95% (SD 24.55). We observed that the thickness and length of EBBI were superior in the young patient or patients with giant cell tumour that did not receive chemotherapy, compared to patients treated for osteosarcoma. The distal femur also had better EBBI compared to the proximal tibia. However, the final multivariable statistical analysis showed no significant difference in all variables. EBBI thickness was significantly and positively correlated with EBBI Length (p<0.001). We conclude that, for each 1mm increase in EBBI thickness, the length will increase by 0.06% on average. About 17.2% of patients out of the 29 showed no radiological evidence of EBBI.

    Conclusion: From our study, there were no factors that significantly contributed to the formation and incorporation of EBBI.

    Matched MeSH terms: Autografts
  3. Anandan V, Goh TC, Zamri KS
    Cureus, 2020 Dec 23;12(12):e12243.
    PMID: 33500862 DOI: 10.7759/cureus.12243
    Objective To compare long-term functional results of ACL reconstruction with a single bundle (SB) and double bundle (DB). Methods Sixty patients who underwent ACL reconstructions from January 2007 to December 2008 were retrospectively evaluated (30 SB and 30 DB ACL reconstructions). Clinical and functional outcomes were measured pre- and postoperatively in terms of anterior drawer test, Lachman's test, pivot shift test, KT1000 side-to-side difference, range of motion, International Knee Documentation Committee Scoring, Lysholm knee scoring scale (LKS), and Tegner activity level scale. The period of follow-up was 10 years. Results Clinical outcome measured showed that anterior drawer test result were equally normal for both groups (93.3%; p > 0.995); however, the Lachman test was 76.7% in the DB group and 56.7% in the SB group (p > 0.100), the pivot shift was 83% in the DB group and 50% in the SB group (p < 0.001), and KT1000 was 76.7% in the DB group and 56.7% in the SB group (p > 0.100). Regarding the functional outcome, it favored the DB group of patients, with the LKS being statistically significant (p < 0.007) and the Tegner activity level scale p-value being <0.001 Conclusions DB ACL reconstruction produces better rotational stability and gives superior functional outcome in terms of return to pre-injury activity level in comparison to SB reconstruction. DB ACL reconstruction using hamstring tendon autograft produces better functional results at 10 years follow-up.
    Matched MeSH terms: Autografts
  4. Moshiri A, Tekyieh Maroof N, Mohammad Sharifi A
    Iran J Basic Med Sci, 2020 Nov;23(11):1426-1438.
    PMID: 33235700 DOI: 10.22038/ijbms.2020.46228.10707
    Objectives: We investigated the role of various biomaterials on cell viability and in healing of an experimentally induced femoral bone hole model in rats.

    Materials and Methods: Cell viability and cytotoxicity of gelatin (Gel; 50 µg/µl), chitosan (Chi; 20 µg/µl), hydroxyapatite (HA; 50 µg/µl), nanohydroxyapatite (nHA; 10 µg/µl), three-calcium phosphate (TCP; 50 µg/µl) and strontium carbonate (Sr; 10 µg/µl) were evaluated on hADSCs via MTT assay. In vivo femoral drill-bone hole model was produced in rats that were either left untreated or treated with autograft, Gel, Chi, HA, nHA, TCP and Sr, respectively. The animals were euthanized after 30 days. Their bone holes were evaluated by gross-pathology, histopathology, SEM and radiography. Also, their dry matter, bone ash and mineral density were measured.

    Results: Both the Gel and Chi showed cytotoxicity, while nHA had no role on cytotoxicity and cell-viability. All the HA, TCP and Sr significantly improved cell viability when compared to controls (P<0.05). Both the Gel and Chi had no role on osteoconduction and osteoinduction. Compared to HA, nHA showed superior role in increasing new bone formation, mineral density and ash (P<0.05). In contrast to HA and nHA, both the TCP and Sr showed superior morphological, radiographical and biochemical properties on bone healing (P<0.05). TCP and Sr showed the most effective osteoconduction and osteoinduction, respectively. In the Sr group, the most mature type of osteons formed.

    Conclusion: Various biomaterials have different in vivo efficacy during bone regeneration. TCP was found to be the best material for osteoconduction and Sr for osteoinduction.

    Matched MeSH terms: Autografts
  5. Hussin HM, Lawi MM, Haflah NHM, Kassim AYM, Idrus RBH, Lokanathan Y
    Tissue Eng Regen Med, 2020 04;17(2):237-251.
    PMID: 32036567 DOI: 10.1007/s13770-019-00235-6
    BACKGROUND: Centella asiatica (L.) is a plant with neuroprotective and neuroregenerative properties; however, its effects on the neurodifferentiation of mesenchymal stem cells (MSCs) and on peripheral nerve injury are poorly explored. This study aimed to investigate the effects of C. asiatica (L.)-neurodifferentiated MSCs on the regeneration of peripheral nerve in a critical-size defect animal model.

    METHODS: Nerve conduit was developed using decellularised artery seeded with C. asiatica-neurodifferentiated MSCs (ndMSCs). A 1.5 cm sciatic nerve injury in Sprague-Dawley rat was bridged with reversed autograft (RA) (n = 3, the gold standard treatment), MSC-seeded conduit (MC) (n = 4) or ndMSC-seeded conduit (NC) (n = 4). Pinch test and nerve conduction study were performed every 2 weeks for a total of 12 weeks. At the 12th week, the conduits were examined by histology and transmission electron microscopy.

    RESULTS: NC implantation improved the rats' sensory sensitivity in a similar manner to RA. At the 12th week, nerve conduction velocity was the highest in NC compared with that of RA and MC. Axonal regeneration was enhanced in NC and RA as shown by the expression of myelin basic protein (MBP). The average number of myelinated axons was significantly higher in NC than in MC but significantly lower than in RA. The myelin sheath thickness was higher in NC than in MC but lower than in RA.

    CONCLUSION: NC showed promising effects on nerve regeneration and functional restoration similar to those of RA. These findings revealed the neuroregenerative properties of C. asiatica and its potential as an alternative strategy for the treatment of critical size nerve defect.

    Matched MeSH terms: Autografts
  6. Samal P, Mohapatra NC, Mishra J, Mylarappa A, Das P
    Malays Orthop J, 2020 Mar;14(1):84-87.
    PMID: 32296488 DOI: 10.5704/MOJ.2003.014
    Giant cell tumour of tendon sheath is a benign soft tissue lesion most commonly found in the flexor aspect of hand and wrist. However, it is uncommon in foot and ankle and rare in bilateral achilles tendon. We report a case of 17-year-old female who presented with progressive enlargement of bilateral achilles tendon for six months. MRI findings showed that most of the tumour had intermediate to low signal intensity. Histopathology confirmed the diagnosis of giant cell tumour of tendon sheath. To help the patient regain the strength of the achilles tendon and walking abilities, a large area of tendon tumour was excised, followed by reconstruction with transfer of the peroneus brevis (PB) and posterior tibial (PT) tendon autograft. At two years follow-up, functional result was satisfactory.
    Matched MeSH terms: Autografts
  7. Ahmed N, Shihabudin M.T, Ab Rahman S
    MyJurnal
    Introduction: Hamstring tendon (HT) and bone patellar tendon bone (BPTB) are the commonly used
    autograft in an anterior cruciate ligament reconstruction surgery. The BPTB is said to have more incidence of
    anterior knee pain compared to HT. The study aimed to compare the severity of knee pain during Islamic
    prayer kneeling. Methods: A cross sectional cohort analysis of patients undergoing ACL reconstruction surgery
    using BPTB with HT autografts was conducted to determine differences in postoperative pain while kneeling
    and ability to pray in normal position. Kneeling during prayer and the ability to sit while performing prayer
    were assessed at 3rd, 4th, 5th and 6th month. Results: There were no significant differences in mean pain score
    while kneeling at 3rd, 4th, 5th and 6th month. The mean difference of patient’s ability to perform normal
    prayers for BPTB (3.56+1.16) and HT (3.30+1.05) was found insignificant. The average number of patients in
    both groups was able to pray between 3 to 4 months post operatively as full range of motion of knee is
    allowed within this period. Total 49 patients (BPTB 23, HT 26) out of 60 were able to pray normally within 4
    months post-operation. Mostly delayed due to anterior knee pain. Conclusion: There is no different in term of
    knee pain during kneeling while performing Islamic prayer between those who had their ACL reconstructed
    either using BPTB or HT autograft.
    Matched MeSH terms: Autografts
  8. Leong YC, Muhammad-Suhairi J
    Malays Orthop J, 2019 Jul;13(2):45-48.
    PMID: 31467652 DOI: 10.5704/MOJ.1907.009
    Treatment of chronic Rockwood's type V Acromioclavicular (AC) joint dislocation remains controversial. We describe a surgical technique to reduce and maintain AC joint using a combination of gracilis autograft with GraftMax™ button (Conmed Inc, Utica, NY). Graft was prepared using running whip stitch technique with No. 5 Hi-Fi high strength suture (ConMed Linvatec, Largo, FL). Our technique reduces intraoperative clavicular and coracoid tunnel fracture and restores anatomical coracoclavicular ligament. At sixth week and third month postoperatively, the patient demonstrated good clinical and radiographic outcome.
    Matched MeSH terms: Autografts
  9. Mohd Asihin MA, Bajuri MY, Ahmad J, Syed Kamaruddin SF
    Ceylon Med J, 2018 03 31;63(1):11-16.
    PMID: 29754479
    Objectives: To evaluate the feasibility of ultrasonographic examination in predicting 4-strand semitendinosus and gracilis tendon (4S-STG) autograft size preoperatively in anterior cruciate ligament reconstruction and to evaluate the use of anthropometric measurement to predict the 4-strand semitendinosus and gracilis tendons (4S-STG) autograft size pre-operatively in anterior cruciate ligament reconstruction.

    Method: Twenty-seven patients were included in this study conducted from 1st January to 31st December 2013. All patients were skeletally mature and scheduled to undergo primary anterior cruciate ligament reconstruction using 4S-STG autograft. Ultrasonographic examination of semitendinosus and gracilis tendons to measure the cross sectional area was conducted and anthropometric data (weight, height, leg length and thigh circumference) was measured one day prior to surgery. True autograft diameters were measured intraoperatively using closed-hole sizing block in 0.5 mm incremental size.

    Results: There is a statistically significant correlation between the measured combined cross sectional area (semitendinosus and gracilis tendons) and 4S-STG autograft diameter (p = 0.023). An adequate autograft size (at least 7 mm) can be obtained when the combined cross sectional area is at least 15 mm2. There was no correlation with the anthropometric data except for thigh circumference (p = 0.037). Autograft size of at least 7 mm can be obtained when the thigh circumference is at least 41 mm.

    Conclusions: Both combined cross sectional area (semitendinosus and gracilis tendons) and thigh circumference can be used to predict an adequate 4S-STG autograft size.

    Matched MeSH terms: Autografts/anatomy & histology; Autografts/transplantation
  10. Choi JR, Yong KW, Choi JY
    J Cell Physiol, 2018 Mar;233(3):1913-1928.
    PMID: 28542924 DOI: 10.1002/jcp.26018
    Today, articular cartilage damage is a major health problem, affecting people of all ages. The existing conventional articular cartilage repair techniques, such as autologous chondrocyte implantation (ACI), microfracture, and mosaicplasty, have many shortcomings which negatively affect their clinical outcomes. Therefore, it is essential to develop an alternative and efficient articular repair technique that can address those shortcomings. Cartilage tissue engineering, which aims to create a tissue-engineered cartilage derived from human mesenchymal stem cells (MSCs), shows great promise for improving articular cartilage defect therapy. However, the use of tissue-engineered cartilage for the clinical therapy of articular cartilage defect still remains challenging. Despite the importance of mechanical loading to create a functional cartilage has been well demonstrated, the specific type of mechanical loading and its optimal loading regime is still under investigation. This review summarizes the most recent advances in the effects of mechanical loading on human MSCs. First, the existing conventional articular repair techniques and their shortcomings are highlighted. The important parameters for the evaluation of the tissue-engineered cartilage, including chondrogenic and hypertrophic differentiation of human MSCs are briefly discussed. The influence of mechanical loading on human MSCs is subsequently reviewed and the possible mechanotransduction signaling is highlighted. The development of non-hypertrophic chondrogenesis in response to the changing mechanical microenvironment will aid in the establishment of a tissue-engineered cartilage for efficient articular cartilage repair.
    Matched MeSH terms: Autografts/cytology
  11. Mohd S, Yusof N, Ramalingam S, Ng WM, Mansor A
    Malays Orthop J, 2017 Jul;11(2):1-6.
    PMID: 29021871 MyJurnal DOI: 10.5704/MOJ.1707.004
    Despite increasing use of bone graft in Malaysia, there was still lack of data to quantify knowledge level on bone banking among orthopaedic community who are involved in transplantation related work. Therefore, a survey on awareness in tissue banking specifically bone banking, usage and choice of bone grafts was conducted. From 80 respondents, 82.5% were aware about tissue banking however only 12.5% knew of the existence of tissue banks in Malaysia. Femoral head was the bone allograft most often used as a substitute to autograft. Only 34.8% respondents preferred irradiated bone grafts whilst 46.9% preferred nonirradiated, indicating the need to educate the importance of radiation for sterilising tissues. Exhibition was the most preferred medium for awareness programme to disseminate information about bone banking in the orthopaedic community. The professional awareness is necessary to increase the knowledge on the use of bone graft, hence to increase bone transplantation for musculoskeletal surgeries in the country.
    Matched MeSH terms: Autografts
  12. Nadarajah G, Ratnalingam VH, Mohd Isa H
    Cornea, 2017 Apr;36(4):452-456.
    PMID: 27941383 DOI: 10.1097/ICO.0000000000001106
    PURPOSE: To evaluate graft stability and recurrence rate between fibrin glue and autologous blood in pterygium conjunctival autograft surgery.

    METHODS: A prospective, randomized, single-blinded clinical trial to assess the efficacy of autologous blood in place of fibrin glue in pterygium surgery. A total of 120 eyes of 111 patients were randomized according to pterygium morphology, to undergo pterygium surgery with autografting using either autologous blood or fibrin glue. All patients were operated by a single surgeon; 58 eyes were operated using fibrin glue and 62 eyes had a conjunctival autograft with autologous blood. Patients were seen on postoperative day 1, 1 week, 1 month, 6 months, and 1 year after surgery. Graft stability and pterygium recurrence were graded by an independent observer who was masked to the method of treatment.

    RESULTS: All 120 eyes completed the 1-year follow-up. Graft loss was seen only in the autologous blood group. Of the 62 eyes in this group, a total of 15 (24.2%) grafts dislodged. Recurrence was calculated after excluding grafts that were dislodged. Of the 105 patients, there were a total of 7 recurrences, 2 (3.4%) from the fibrin adhesive method and 5 (10.6%) from the autologous blood method. This was not statistically significant (P = 0.238).

    CONCLUSIONS: Autologous blood does not exhibit similar graft stability seen with fibrin glue. Although the recurrence rate may not be significant, careful patient selection and a standard method needs to be laid out before the use of this method is widely accepted.

    Matched MeSH terms: Autografts
  13. Issaragrisil S, Cheng-Hwai T, Bunworasate U, Su-Peng Y, Hung LY, Tee GY, et al.
    Bone Marrow Transplant, 2017 02;52(2):299-300.
    PMID: 27841857 DOI: 10.1038/bmt.2016.245
    Matched MeSH terms: Autografts
  14. Romano V, Cruciani M, Conti L, Fontana L
    Cochrane Database Syst Rev, 2016 12 02;12:CD011308.
    PMID: 27911983 DOI: 10.1002/14651858.CD011308.pub2
    BACKGROUND: Pterygium, a growth of the conjunctiva over the cornea, is a progressive disease leading in advanced stages to visual impairment, restriction of ocular motility, chronic inflammation and cosmetic concerns. Surgical removal is the treatment of choice, but recurrence can be a problem. Currently the best surgical option in terms of recurrence is conjunctival autograft. To date the most common surgical methods of attaching conjunctival autografts to the sclera are through suturing or fibrin glue. Each method presents its own advantages and disadvantages. Sutures require considerable skill from the surgeon and can be associated with a prolonged operation time, postoperative discomfort and suture-related complications, whereas fibrin glue may give a decreased operation time, improve postoperative comfort and avoid suture-related problems.

    OBJECTIVES: To assess the effectiveness of fibrin glue compared to sutures in conjunctival autografting for the surgical treatment of pterygium.

    SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 9), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to October 2016), Embase (January 1980 to October 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 14 October 2016.

    SELECTION CRITERIA: We included randomised controlled trials (RCTs) in any setting where fibrin glue was compared with sutures to treat people with pterygium.

    DATA COLLECTION AND ANALYSIS: Two review authors independently screened the search results, assessed trial quality, and extracted data using standard methodological procedures expected by Cochrane. Our primary outcome was recurrence of pterygium defined as any re-growth of tissue from the area of excision across the limbus onto the cornea. The secondary outcomes were surgical time and complication rate. We graded the certainty of the evidence using GRADE.

    MAIN RESULTS: We included 14 RCTs conducted in Brazil, China, Egypt, India, Malaysia, New Zealand, Philippines, Saudi Arabia, Sweden and Turkey. The trials were published between 2004 and 2016, and were assessed as a mixture of unclear and low risk of bias with three studies at high risk of attrition bias. Only adults were enrolled in these studies.Using fibrin glue for the conjunctival autograft may result in less recurrence of pterygium compared with using sutures (risk ratio (RR) 0.47, 95% CI 0.27 to 0.82, 762 eyes, 12 RCTs; low-certainty evidence). If pterygium recurs after approximately 10 in every 100 surgeries with sutures, then using fibrin glue may result in approximately 5 fewer cases of recurrence in every 100 surgeries (95% CI 2 fewer to 7 fewer cases). Using fibrin glue may lead to more complications compared with sutures (RR 1.92; 95% CI 1.22 to 3.02, 11 RCTs, 673 eyes, low-certainty evidence). The most common complications reported were: graft dehiscence, graft retraction and granuloma. On average using fibrin glue may mean that surgery is quicker compared with suturing (mean difference (MD) -17.01 minutes 95% CI -20.56 to -13.46), 9 RCTs, 614 eyes, low-certainty evidence).

    AUTHORS' CONCLUSIONS: The meta-analyses, conducted on people with pterygium in a hospital or outpatient setting, show fibrin glue may result in less recurrence and may take less time than sutures for fixing the conjunctival graft in place during pterygium surgery. There was low-certainty evidence to suggest a higher proportion of complications in the fibrin glue group.

    Matched MeSH terms: Autografts*
  15. Hanifi N, Halim AS, Aleas CF, Singh J, Marzuki M, Win TT, et al.
    Exp Clin Transplant, 2015 Jun;13(3):273-8.
    PMID: 26086837
    Skin grafting has been evolving as an important application in reconstructive surgery. Mixed reports about the survival of allogeneic and xenogeneic keratinocytes require further substantiation to determine the role of these cells in wound healing.
    Matched MeSH terms: Autografts
  16. Yasin NF, Ajit Singh V, Saad M, Omar E
    BMC Cancer, 2015;15:289.
    PMID: 25884718 DOI: 10.1186/s12885-015-1234-9
    Limb salvage surgery is a treatment of choice for sarcomas of the extremities. One of the options in skeletal reconstruction after tumour resection is by using a recycled bone autograft. The present accepted methods of recycling bone autografts include autoclaving, pasteurization and irradiation. At the moment there is lack of studies that compare the effectiveness of various sterilization methods used for recycling bone autografts and their effects in terms of bone incorporation. This study was performed to determine the effects of different methods of sterilization on bone autografts in rabbit by radiological, biomechanical and histopathological evaluations.
    Matched MeSH terms: Autografts/transplantation*
  17. Ariff, M.S., Faisham, W.I., Krishnan, J., Zulmi, W.
    MyJurnal
    Ewing sarcoma is a primary bone malignancy that rarely occurs in the hand. Resection and reconstruction will usually result in reduced or loss of thumb function. We describe a case of successful transplantation of non- vascularized osteoarticular second metatarsal autograft following wide resection of Ewing sarcoma of first metacarpal in an 11-year-old girl. The capsule of the graft’s metatarso-phalangeal joint was repaired to achieve mobility of the joint. This enabled preservation of thumb function by a relatively simple surgical technique. Detailed surgical procedures and excellence function after 2 years following surgery are described.
    Matched MeSH terms: Autografts
  18. Safinaz MK, Norzana AG, Hairul Nizam MH, Ropilah AR, Faridah HA, Chua KH, et al.
    Cell Tissue Bank, 2014 Dec;15(4):619-26.
    PMID: 24633432 DOI: 10.1007/s10561-014-9436-y
    The purpose of this study was to compare the use of autologous fibrin to human amniotic membrane (HAM) as a scaffold in cultivating autologous conjunctiva for transplantation in treatment of conjunctival defect. An experimental study was performed using 18 adult New Zealand white strain rabbits which were divided into 3 groups. Each group consists of 6 rabbits. The conjunctiva on the temporal site was excised to create a conjunctival epithelial defect. The excised area in the Group 1 was transplanted with autologous conjunctiva cultivated on autologous fibrin; Group 2 was transplanted with autologous conjunctiva cultivated on HAM and Group 3 was left bare. The rabbits were followed up at regular intervals until 6 weeks. The mean period of complete conjunctival epithelization was 11.50 ± 8.22 days for the autologous fibrin group, 15.33 ± 11.80 days for the HAM group and 25.33 ± 5.32 days in the bare sclera group. The epithelization rate for the autologous fibrin group was faster compared to the other two groups. However all the results were not statistically significant (p value >0.05). There were no postoperative complications noted during the follow up. Autologous fibrin is comparable to HAM as a scaffold for cultivation of conjunctiva in the treatment of conjunctival defect.
    Matched MeSH terms: Autografts*
  19. Siow SL, Mahendran HA
    Surg Laparosc Endosc Percutan Tech, 2014 Apr;24(2):134-9.
    PMID: 24686348 DOI: 10.1097/SLE.0b013e31828fa951
    We propose a standardized technique of repair and lavage with the outcomes of 50 consecutive patients treated at our institution. The perforation was closed primarily and reinforced with omental patch. It was then followed by peritoneal lavage in a focused sequential manner that involved quadrant to quadrant lavage with tilting of operating table and changing of position between the surgeon and the camera surgeon. None of our patients had postoperative intra-abdominal complications, but unfortunately 1 patient succumbed to respiratory complications. Respiratory complications was the most common postoperative complication in our series (9 patients), whereas 2 patients had ileus. There were no leaks or reoperations in our series. Laparoscopic repair and sutured omentoplasty, followed by focused sequential lavage in a systematic manner, if performed diligently, will yield good outcomes.
    Matched MeSH terms: Autografts
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links