Displaying publications 1 - 20 of 28 in total

Abstract:
Sort:
  1. Lasekan O, Salva JT, Abbas K
    J Sci Food Agric, 2010 Apr 15;90(5):850-60.
    PMID: 20355122 DOI: 10.1002/jsfa.3895
    Considering the importance of malting and roasting on the quality of 'acha' beverages, a study was conducted to find optimum conditions for malting and the production of a high-quality roasted extract that could be used for an 'acha' beverage.
    Matched MeSH terms: Beverages/analysis*
  2. Kuswandi B, Irmawati T, Hidayat MA, Jayus, Ahmad M
    Sensors (Basel), 2014;14(2):2135-49.
    PMID: 24473284 DOI: 10.3390/s140202135
    A simple visual ethanol biosensor based on alcohol oxidase (AOX) immobilised onto polyaniline (PANI) film for halal verification of fermented beverage samples is described. This biosensor responds to ethanol via a colour change from green to blue, due to the enzymatic reaction of ethanol that produces acetaldehyde and hydrogen peroxide, when the latter oxidizes the PANI film. The procedure to obtain this biosensor consists of the immobilization of AOX onto PANI film by adsorption. For the immobilisation, an AOX solution is deposited on the PANI film and left at room temperature until dried (30 min). The biosensor was constructed as a dip stick for visual and simple use. The colour changes of the films have been scanned and analysed using image analysis software (i.e., ImageJ) to study the characteristics of the biosensor's response toward ethanol. The biosensor has a linear response in an ethanol concentration range of 0.01%-0.8%, with a correlation coefficient (r) of 0.996. The limit detection of the biosensor was 0.001%, with reproducibility (RSD) of 1.6% and a life time up to seven weeks when stored at 4 °C. The biosensor provides accurate results for ethanol determination in fermented drinks and was in good agreement with the standard method (gas chromatography) results. Thus, the biosensor could be used as a simple visual method for ethanol determination in fermented beverage samples that can be useful for Muslim community for halal verification.
    Matched MeSH terms: Beverages/analysis*
  3. Hashim AK, Hatif AR, Ahmed NM, Wadi IA, Al Qaaod AA
    Appl Radiat Isot, 2021 Jan;167:109410.
    PMID: 33065401 DOI: 10.1016/j.apradiso.2020.109410
    Radon and progeny concentration measurements in various drink samples are intrinsically important for assessing the health risks resulting from daily consumption of these drinks. In this study the comparison between two Solid State Nuclear Track Detectors (SSNTDs), the CR-39 and the CN-85 has been conducted for the purpose of evaluating the radon concentration, annual effective dose, the rate of exhalation of radon and the effective radium content in thirty-two different samples of soft drink, water, and milk available in the local Iraq markets. The results showed that there are significant differences in the measurement results for the two detectors. The annual effective dose of the investigated samples is still below the limit of International Commission on Radiological Protection (ICRP) recommendation in the measurements of both detectors.
    Matched MeSH terms: Beverages/analysis*
  4. Lawal A, Tan GH, Alsharif AM
    J AOAC Int, 2016 Nov 01;99(6):1383-1394.
    PMID: 27667201 DOI: 10.5740/jaoacint.16-0272
    Food quality and food safety are major challenges affecting agricultural and industrial aspects of production. Many contaminants from different sources contaminate foods and drinks, leading to disastrous health problems like gene mutations and cancer. Previously, many different methods have been used for the analysis of these contaminants. Liquid-liquid extraction (LLE) has been the most well-known conventional technique used, but its limitations are its tediousness, time required, and the use of large quantities of toxic organic solvents. These limitations have led to the search for other, efficient techniques that are more environmentally friendly. Hence, this review highlights recent advances in liquid-phase (single-drop, hollow fiber, and dispersive liquid-liquid) microextraction procedures for food and drink analyses. Such modifications can be justified for solving limitations associated with the traditional LLE method. The objective of this review is to serve as a reference platform for providing effective management tools for solving problems of pollution, clean-up, and control of food quality and safety globally.
    Matched MeSH terms: Beverages/analysis*
  5. Navarrete-Muñoz EM, Wark PA, Romaguera D, Bhoo-Pathy N, Michaud D, Molina-Montes E, et al.
    Am J Clin Nutr, 2016 Sep;104(3):760-8.
    PMID: 27510540 DOI: 10.3945/ajcn.116.130963
    BACKGROUND: The consumption of sweet beverages has been associated with greater risk of type 2 diabetes and obesity, which may be involved in the development of pancreatic cancer. Therefore, it has been hypothesized that sweet beverages may increase pancreatic cancer risk as well.

    OBJECTIVE: We examined the association between sweet-beverage consumption (including total, sugar-sweetened, and artificially sweetened soft drink and juice and nectar consumption) and pancreatic cancer risk.

    DESIGN: The study was conducted within the European Prospective Investigation into Cancer and Nutrition cohort. A total of 477,199 participants (70.2% women) with a mean age of 51 y at baseline were included, and 865 exocrine pancreatic cancers were diagnosed after a median follow-up of 11.60 y (IQR: 10.10-12.60 y). Sweet-beverage consumption was assessed with the use of validated dietary questionnaires at baseline. HRs and 95% CIs were obtained with the use of multivariable Cox regression models that were stratified by age, sex, and center and adjusted for educational level, physical activity, smoking status, and alcohol consumption. Associations with total soft-drink consumption were adjusted for juice and nectar consumption and vice versa.

    RESULTS: Total soft-drink consumption (HR per 100 g/d: 1.03; 95% CI: 0.99, 1.07), sugar-sweetened soft-drink consumption (HR per 100 g/d: 1.02; 95% CI: 0.97, 1.08), and artificially sweetened soft-drink consumption (HR per 100 g/d: 1.04; 95% CI: 0.98, 1.10) were not associated with pancreatic cancer risk. Juice and nectar consumption was inversely associated with pancreatic cancer risk (HR per 100 g/d: 0.91; 95% CI: 0.84, 0.99); this association remained statistically significant after adjustment for body size, type 2 diabetes, and energy intake.

    CONCLUSIONS: Soft-drink consumption does not seem to be associated with pancreatic cancer risk. Juice and nectar consumption might be associated with a modest decreased pancreatic cancer risk. Additional studies with specific information on juice and nectar subtypes are warranted to clarify these results.

    Matched MeSH terms: Beverages/analysis; Carbonated Beverages/analysis
  6. Tan TC, Cheng LH, Bhat R, Rusul G, Easa AM
    Food Chem, 2014 Jan 1;142:121-8.
    PMID: 24001821 DOI: 10.1016/j.foodchem.2013.07.040
    Composition, physicochemical properties and enzyme inactivation kinetics of coconut water were compared between immature (IMC), mature (MC) and overly-mature coconuts (OMC). Among the samples studied, pH, turbidity and mineral contents for OMC water was the highest, whereas water volume, titratable acidity, total soluble solids and total phenolics content for OMC water were the lowest. Maturity was found to affect sugar contents. Sucrose content was found to increase with maturity, and the reverse trend was observed for fructose and glucose. Enzyme activity assessment showed that polyphenol oxidase (PPO) in all samples was more heat resistant than peroxidase (POD). Compared to IMC and MC, PPO and POD from OMC water showed the lowest thermal resistance, with D83.3°C=243.9s (z=27.9°C), and D83.3°C=129.9s (z=19.5°C), respectively.
    Matched MeSH terms: Beverages/analysis*
  7. Mirhosseini H, Tan CP, Yusof S, Hamid NS
    Phytochem Anal, 2008 Sep-Oct;19(5):429-37.
    PMID: 18435528 DOI: 10.1002/pca.1068
    Solid-phase microextraction (SPME) coupled to gas chromatography has been applied for the headspace analysis (HS) of 12 target flavour compounds in a model orange beverage emulsion. The main volatile flavour compounds studied were: acetaldehyde, ethyl acetate, alpha-pinene, ethyl butyrate, beta-pinene, myrcene, limonene, gamma-terpinene, octanal, decanal, linalool and citral (neral plus geranial). After screening the fibre type, the effect of other HS-SPME variables such as adsorption temperature (25-55 degrees C), extraction time (10-40 min), sample concentration (1-100% w/w), sample amount (5-10 g) and salt amount (0-30% w/w) were determined using a two-level fractional factorial design (2(5-2)) that was expanded further to a central composite design. It was found that an extraction process using a carboxen-polydimethylsiloxane fibre coating at 15 masculineC for 50 min with 5 g of diluted emulsion 1% (w/w) and 30% (w/w) of sodium chloride under stirring mode resulted in the highest HS extraction efficiency. For all volatile flavour compounds, the linearity values were accurate in the concentration ranges studied (r(2) > 0.97). Average recoveries that ranged from 90.3 to 124.8% showed a good accuracy for the optimised method. The relative standard deviation for six replicates of all volatile flavour compounds was found to be less than 15%. For all volatile flavour compounds, the limit of detection ranged from 0.20 to 1.69 mg/L.
    Matched MeSH terms: Beverages/analysis*
  8. Loh SH, Sanagi MM, Wan Ibrahim WA, Hasan MN
    Talanta, 2013 Mar 15;106:200-5.
    PMID: 23598117 DOI: 10.1016/j.talanta.2012.12.032
    A new microextraction procedure termed multi-walled carbon nanotube-impregnated agarose film microextraction (MWCNT-AFME) has been developed. The method utilized multi-walled carbon nanotubes (MWCNTs) immobilized in agarose film to serve as adsorbent in solid phase microextraction (SPME). The film was prepared by mixing the MWCNTs in agarose solution and drying the mixture in oven. Extraction of selected polycyclic aromatic hydrocarbons was performed by inserting a needle through circular MWCNT-impregnated agarose films (5 mm diameter) and the assembly was dipped into an agitated sample solution prior to micro high performance liquid chromatography-ultraviolet analysis. Back extraction was then performed using ultrasonication of the films in 100 μL of solvent. The film was discarded after single use, thus avoiding any analyte carry-over effect. Due to the mesoporous nature of the agarose film, the MWCNTs were immobilized easily within the film and thus allowing for close contact between adsorbent and analytes. Under the optimized extraction conditions, the technique achieved trace LODs in the range of 0.1 to 50 ng L(-1) for the targeted analytes, namely fluoranthene, phenanthrene and benzo[a]pyrene. The method was successfully applied to the analysis of spiked green tea beverage samples with good relative recoveries in the range of 91.1 to 107.2%. The results supported the feasibility of agarose to serve as adsorbent holder in SPME which then minimizes the consumption of chemicals and disposal cost of organic wastes.
    Matched MeSH terms: Beverages/analysis*
  9. Tey SL, Van Helvoort A, Henry CJ
    Eur J Nutr, 2016 Dec;55(8):2493-2498.
    PMID: 26467048
    PURPOSE: A limited number of studies have compared the glycaemic index (GI) and glycaemic responses (GR) to solid foods between Caucasians and Asians. These studies have demonstrated that Asians have greater GI and GR values for solid foods than Caucasians. However, no study has compared the GI and GR to liquids among various Asian ethnic groups.

    METHODS: A total of forty-eight males and females (16 Chinese, 16 Indians, and 16 Malay) took part in this randomised, crossover study. Glycaemic response to the reference food (glucose beverage) was measured on three occasions, and GR to three liquids were measured on one occasion each. Liquids with different macronutrient ratio's and carbohydrate types were chosen to be able to evaluate the response to products with different GIs. Blood glucose concentrations were measured in duplicate at baseline (-5 and 0 min) and once at 15, 30, 45, 60, 90, and 120 min after the commencement of beverage consumption.

    RESULTS: There were statistically significant differences in GI and GR between the three liquids (P 

    Matched MeSH terms: Beverages/analysis
  10. Musa KH, Abdullah A, Kuswandi B, Hidayat MA
    Food Chem, 2013 Dec 15;141(4):4102-6.
    PMID: 23993591 DOI: 10.1016/j.foodchem.2013.06.112
    A stable chromogenic radical 2,2-diphenyl-1-picrylhydrazyl (DPPH) is commonly used for the determination of antioxidant activity. In this paper, DPPH was dried into 96 well microplate to produce DPPH dry reagent array plate, based on which the highly sensitive and high throughput determination of antioxidant activities was achieved. The spectrophotometric characterization of the microplate containing dried or fresh DPPH free radicals was reported. The response of the DPPH dry reagent array towards different standard antioxidants was studied. The reaction for DPPH in fresh or dry reagent array with Trolox was reported and compared. The DPPH dry reagent array was used to study the antioxidant activity of banana, green tea, pink guava, and honeydew and the results were compared to the samples reacted with freshly prepared DPPH. The proposed method is comparable to the classical DPPH method, more convenient, simple to operate with minimal solvent required and excellent sensitivity.
    Matched MeSH terms: Beverages/analysis*
  11. Ariffin F, Heong Chew S, Bhupinder K, Karim AA, Huda N
    J Sci Food Agric, 2011 Dec;91(15):2731-9.
    PMID: 21987075 DOI: 10.1002/jsfa.4454
    C. asiatica was exposed to various fermentations: no fermentation (0 min), partial fermentation (120 min) and full fermentation (24 h). Total phenolic content (TPC) and ferric-reducing antioxidant power (FRAP) of C. asiatica infusions were studied as a function of water temperature (60, 80 or 100 °C), the brewing stage (one, two or three) and the brewing time (1, 3, 5, 10, 15 or 20 min). The optimum brewing procedure was adopted to study the antioxidant properties and phenolic compounds in C. asiatica infusions.
    Matched MeSH terms: Beverages/analysis*
  12. Bhat R, Kamaruddin NS, Min-Tze L, Karim AA
    Ultrason Sonochem, 2011 Nov;18(6):1295-300.
    PMID: 21550834 DOI: 10.1016/j.ultsonch.2011.04.002
    Freshly squeezed kasturi lime fruit juice was sonicated (for 0, 30 and 60min at 20°C, 25kHz frequency) to evaluate its impact on selected physico-chemical and antioxidant properties, such as pH, °Brix, titratable acidity, Hunter color values (L(∗), a(∗), b(∗)), ascorbic acid, DPPH radical scavenging activity, total phenolics, antioxidant capacity, flavonoids and flavonols. Additionally, the effect of sonication treatments on the microbial load (TPC, yeast and mold) were also evaluated. Sonication of juice samples for 60min showed enhancement in most of the bioactive compounds compared to samples treated for 30min and control samples (untreated). Significant reductions in the microbial load corresponding to sonication time were also recorded. Results of the present study indicate that sonication may be employed as a suitable technique for kasturi lime juice processing, where antioxidant and other bioactive compound retention or enhancement is desired, along with the achievement of safety and quality standards.
    Matched MeSH terms: Beverages/analysis*
  13. Khayoon WS, Saad B, Salleh B, Manaf NH, Latiff AA
    Food Chem, 2014 Mar 15;147:287-94.
    PMID: 24206720 DOI: 10.1016/j.foodchem.2013.09.049
    A single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography-tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20mg; extraction time, 90 min; stirring speed, 1,000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1, AFB2 and AFB1, respectively were achieved. Good linearity and correlation coefficient was obtained over the concentration range of 0.4-50 ng g(-1) (r(2) 0.9988-0.9999). Good recoveries for AFs ranging from 86.0-109% were obtained. The method was applied to 40 samples involving malt beverage (19) and canned coffee (21). No AFs were detected in the selected samples.
    Matched MeSH terms: Beverages/analysis*
  14. Parthasarathy S, Ramanathan S, Murugaiyah V, Hamdan MR, Said MI, Lai CS, et al.
    Forensic Sci Int, 2013 Mar 10;226(1-3):183-7.
    PMID: 23385139 DOI: 10.1016/j.forsciint.2013.01.014
    Mitragyna speciosa, a native plant of Thailand and Malaysia known as 'ketum', is a plant of considerable interest. It exhibits strong antinociceptive effect and yet, acts like a psychostimulant. Due to the affordability and its ease of availability, the abuse of this plant as a substitute for other banned narcotics has become a major concern in many societies. In countries such as Thailand, Myanmar, Australia and Malaysia, the use of ketum is illegal. However, for a person to be charged for possessing or selling ketum, a reliable analytical method is needed in order to detect and identify the plant and its products. Mitragynine is the major alkaloid of ketum. This compound manifests its antinociceptive effects by acting on the opioid receptors. Since M. speciosa contain large quantity of mitragynine and it is exclusive to the species, the present analytical method is developed and validated for the purpose of screening ketum products based on this unique compound as the analytical marker. The method uses a HPLC-DAD system with Inertsil C8 (4.6 mm × 150 mm, 5 μm) as the column and a mixture of acetonitrile and formic acid, 50:50 (v/v), as the mobile phase. This method not only detects mitragynine, it can also be used to quantify the amount of mitragynine in the sample. The limit of detection is 0.25 μg/ml, while the limit of quantification is 0.50 μg/ml. The method is quick, simple and reliable with an accuracy of 97.27-101.74% and coefficient of variations of between 0.91 and 3.96%. The method has been tested and found suitable for the identification and quantification of mitragynine in dried plants, a variety of ketum extracts, as well as ketum drink obtained from the market.
    Matched MeSH terms: Beverages/analysis
  15. Saad B, Bee-Leng Y, Saleh MI, Rahman IA, Mansor SM
    J AOAC Int, 2001 8 15;84(4):1151-7.
    PMID: 11501917
    Potentiometric response characteristics were evaluated for quinine selective sensors based on a lipophilic ion-exchanger potassium tetrakis[3,5-bis(trifluoromethylphenyl)]borate (PTFB) immobilized together with plasticizing solvents in polyvinyl chloride membranes. The use of dioctyl phthalate (DOP), 2-nitrophenyl phenyl ether (NPPE), and bis(2-ethylhexyl)adipate (BEHA) plasticizers produced good quality quinine sensors that were sensitive and fast responding, and exhibited near Nernstian responses when used as batch-sensors. These membranes were further tested in a wall-jet flow-through potentiometric flow injection analysis (FIA) detector. Quinine sensors containing BEHA were the most suitable membrane, with no noticeable differences in sensitivity even after 5 h of continuous exposure to solutions. Interference by foreign species such as alkali, alkaline earth metal ions, sugars, and sodium benzoate was minimal in either the batch-mode (log selectivity coefficients
    Matched MeSH terms: Beverages/analysis*
  16. Singh D, Murugaiyah V, Hamid SBS, Kasinather V, Chan MSA, Ho ETW, et al.
    J Ethnopharmacol, 2018 Jul 15;221:30-36.
    PMID: 29626673 DOI: 10.1016/j.jep.2018.04.005
    ETHNOPHARMACOLOGICAL RELEVANCE: Mitragyna speciosa (Korth.) also known as kratom, is a native medicinal plant of Southeast Asia with opioid-like effects. Kratom tea/juice have been traditionally used as a folk remedy and for controlling opiate withdrawal in Malaysia. Long-term opioid use is associated with depletion in testosterone levels.

    AIM OF THE STUDY: Since kratom is reported to deform sperm morphology and reduce sperm motility, we aimed to clinically investigate the testosterone levels following long-term kratom tea/juice use in regular kratom users.

    METHODS: A total of 19 regular kratom users were recruited for this cross-sectional study. A full-blood test was conducted including determination of testosterone level, follicle stimulating hormone (FSH) and luteinizing hormone (LH) profile, as well as hematological and biochemical parameters of participants.

    RESULTS: We found long-term kratom tea/juice consumption with a daily mitragynine dose of 76.23-94.15 mg did not impair testosterone levels, or gonadotrophins, hematological and biochemical parameters in regular kratom users.

    CONCLUSION: Regular kratom tea/juice consumption over prolonged periods (>2 years) was not associated with testosterone impairing effects in humans.

    Matched MeSH terms: Beverages/analysis
  17. Burdon CA, Johnson NA, Chapman PG, Munir Che Muhamed A, O'Connor HT
    Int J Sport Nutr Exerc Metab, 2013 Aug;23(4):418-24.
    PMID: 23295183
    The aim of this study was to measure the effect of environmental conditions and aid-station beverage- cooling practices on the temperature of competitor beverages.
    Matched MeSH terms: Beverages/analysis*
  18. Sulaiman SF, Ooi KL
    J Agric Food Chem, 2014 Oct 1;62(39):9576-85.
    PMID: 25198055 DOI: 10.1021/jf502912t
    The present study compared pH, total soluble solids, vitamin C, and total phenolic contents, antioxidant activities, and α-glucosidase inhibitory activities of 40 fresh juices. The juice of Baccaurea polyneura showed the highest yield (74.17 ± 1.44%) and total soluble solids (32.83 ± 0.27 °Brix). The highest and lowest pH values were respectively measured from the juices of Dimocarpus longan (6.87 ± 0.01) and Averrhoa bilimbi (1.67 ± 0.67). The juice of Psidium guajava gave the highest total phenolic (857.24 ± 12.65 μg GAE/g sample) and vitamin C contents (590.31 ± 7.44 μg AAE/g sample). The juice of Phyllanthus acidus with moderate contents of total phenolics and vitamin C was found to exhibit the greatest scavenging (613.71 ± 2.59 μg VCEAC/g sample), reducing (2784.89 ± 3.93 μg TEAC/g sample), and α-glucosidase inhibitory activities (95.37 ± 0.15%). The juice of Barringtonia racemosa was ranked second in the activities and total phenolic content. Gallic and ellagic acids, which were quantified as the major phenolics of the respective juices, are suggested to be the main contributors to the antioxidant activities. The α-glucosidase inhibitory activity of the juices could be derived from myricetin and quercetin (that were previously reported as potent α-glucosidase inhibitors) in the hydrolyzed juice extracts. The juice of Syzygium samarangense, which was found to be highest in metal chelating activity (82.28 ± 0.10%), also was found to have these phenolics.
    Matched MeSH terms: Beverages/analysis*
  19. Abu-Bakar NB, Makahleh A, Saad B
    Talanta, 2014 Mar;120:47-54.
    PMID: 24468341 DOI: 10.1016/j.talanta.2013.11.081
    A fast and simple solvent microextraction technique using salting out-vortex-assisted liquid-liquid microextraction (salting out-VALLME) was developed for the extraction of furfurals (2-furfural (2-F), 3-furfural (3-F), 5-methylfurfural (5-MF) and 5-hydroxymethylfurfural (5-HMF)) and patulin (PAT) in fruit juice samples. The optimum extraction conditions for 5 mL sample were: extraction solvent, 1-hexanol; volume of extractant, 200 µL; vortex time, 45 s; salt addition, 20%. The simultaneous determination of the furfurals and PAT were investigated using high performance liquid chromatography coupled with diode array detector (HPLC-DAD). The separation was performed using ODS Hypersil C18 column (4.6 mm i.d × 250 mm, 5 μm) under gradient elution. The detection wavelengths used for all compounds were 280 nm except for 3-F (210 nm). The furfurals and PAT were successfully separated in less than 9 min. Good linearities (r(2)>0.99) were obtained within the range 1-5000 μg L(-1) for all compounds except for 3-F (10-5000 µg L(-1)) and PAT (0.5-100 μg L(-1)). The limits of detection (0.28-3.2 µg L(-1)) were estimated at S/N ratio of 3. The validated salting out-VALLME-HPLC method was applied for the analysis of furfurals and PAT in fruit juice samples (apple, mango and grape).
    Matched MeSH terms: Beverages/analysis*
  20. Lee TP, Saad B, Khayoon WS, Salleh B
    Talanta, 2012 Jan 15;88:129-35.
    PMID: 22265478 DOI: 10.1016/j.talanta.2011.10.021
    A simple, environmental friendly and selective sample preparation technique employing porous membrane protected micro-solid phase extraction (μ-SPE) loaded with molecularly imprinted polymer (MIP) for the determination of ochratoxin A (OTA) is described. After the extraction, the analyte was desorbed using ultrasonication and was analyzed using high performance liquid chromatography. Under the optimized conditions, the detection limits of OTA for coffee, grape juice and urine were 0.06 ng g(-1), 0.02 and 0.02 ng mL(-1), respectively while the quantification limits were 0.19 ng g(-1), 0.06 and 0.08 ng mL(-1), respectively. The recoveries of OTA from coffee spiked at 1, 25 and 50 ng g(-1), grape juice and urine samples at 1, 25 and 50 ng mL(-1) ranged from 90.6 to 101.5%. The proposed method was applied to thirty-eight samples of coffee, grape juice and urine and the presence of OTA was found in eighteen samples. The levels found, however, were all below the legal limits.
    Matched MeSH terms: Beverages/analysis*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links