Displaying publications 1 - 20 of 249 in total

Abstract:
Sort:
  1. Mehrali M, Moghaddam E, Shirazi SF, Baradaran S, Mehrali M, Latibari ST, et al.
    ACS Appl Mater Interfaces, 2014 Mar 26;6(6):3947-62.
    PMID: 24588873 DOI: 10.1021/am500845x
    Calcium silicate (CaSiO3, CS) ceramics are promising bioactive materials for bone tissue engineering, particularly for bone repair. However, the low toughness of CS limits its application in load-bearing conditions. Recent findings indicating the promising biocompatibility of graphene imply that graphene can be used as an additive to improve the mechanical properties of composites. Here, we report a simple method for the synthesis of calcium silicate/reduced graphene oxide (CS/rGO) composites using a hydrothermal approach followed by hot isostatic pressing (HIP). Adding rGO to pure CS increased the hardness of the material by ∼40%, the elastic modulus by ∼52%, and the fracture toughness by ∼123%. Different toughening mechanisms were observed including crack bridging, crack branching, crack deflection, and rGO pull-out, thus increasing the resistance to crack propagation and leading to a considerable improvement in the fracture toughness of the composites. The formation of bone-like apatite on a range of CS/rGO composites with rGO weight percentages ranging from 0 to 1.5 has been investigated in simulated body fluid (SBF). The presence of a bone-like apatite layer on the composite surface after soaking in SBF was demonstrated by X-ray diffraction (XRD) and field emission scanning electron microscopy (FESEM). The biocompatibility of the CS/rGO composites was characterized using methyl thiazole tetrazolium (MTT) assays in vitro. The cell adhesion results showed that human osteoblast cells (hFOB) can adhere to and develop on the CS/rGO composites. In addition, the proliferation rate and alkaline phosphatase (ALP) activity of cells on the CS/rGO composites were improved compared with the pure CS ceramics. These results suggest that calcium silicate/reduced graphene oxide composites are promising materials for biomedical applications.
    Matched MeSH terms: Biomechanical Phenomena
  2. Fauzi, R., Salazar, D.M., Kadzim, R.M., Hussin, A., Burbano, L.
    ASM Science Journal, 2009;3(2):161-167.
    MyJurnal
    In this project, a Geographic Information System (GIS) was used to collect and compile various field data in the Pedro Vicente Maldonado Ecuadorian Scientific Station Antarctica Base area. The main source of data was obtained from a global positioning system (GPS) survey using kinematic GPS (GPS-RTK) which allowed continuous point mapping in the terrain. GPS units were utilized in the collection of spatial data for all field work. The co-ordinates obtained were used to produce a point map which was then exported into GIS software where the proximity of cartographic phenomena and boundaries were mapped. All the collected data were subsequently gathered to develop the GIS database which was then used to generate and compile different maps to test for spatial and temporal relationships. The output of the project comprises a GIS database, spatial maps and 3D terrain model of the area. The developed GIS database can be used with other ecological datasets to provide biogeographical information, potential range distribution and sampling adequacy. The database is also applicable to geographical management and multi-disciplinary research projects.
    Matched MeSH terms: Biomechanical Phenomena
  3. Moo EK, Osman NA, Pingguan-Murphy B, Abas WA, Spence WD, Solomonidis SE
    Acta Bioeng Biomech, 2009;11(4):37-43.
    PMID: 20405814
    Conventionally, patellar tendon-bearing (PTB) sockets, which need high dexterity of prosthetist, are widely used. Lack of chartered and experienced prosthetist has often led to painful experience of wearing prosthesis and this will in turn deter the patients to wear the prosthesis, which will further aggravate stump shrinkage. Thus, the hydrostatic socket which demands relatively lower level of fabricating skill is proposed to replace the PTB socket in order to produce the equivalent, if not better, quality of support to the amputee patients. Both sockets' pressure profiles are studied and compared using finite element analysis (FEA) software. Three-dimensional models of both sockets were developed using MIMICS software. The analysis results showed that hydrostatic socket did exhibit more uniform pressure profiles than that of PTB socket. PTB socket showed pressure concentration near the proximal brim of the socket and also at the distal fibula. It was also found that the pressure magnitude in hydrostatic socket is relatively lower than that of PTB socket.
    Matched MeSH terms: Biomechanical Phenomena
  4. Fazreena Othman N, Salleh Basaruddin K, Hanafi Mat Som M, Shukry Abdul Majid M, Razak Sulaiman A
    Acta Bioeng Biomech, 2019;21(1):55-62.
    PMID: 31197285
    PURPOSE: The aim of this study was to examine the joint contact forces (JCF) between each limb as the LLD magnitude increases during walking activity.

    METHODS: Eighteen male healthy subjects volunteered to participate in the experiment. Walking gait analysis was conducted with eight different levels of insole to simulate the LLD, starting from 0 cm until 4.0 cm with 0.5 cm increment. Qualisys Track Manager System and C-motion Visual 3D biomechanical tools were used to analyse the results. Four joints (ankle, knee, hip, and pelvis) of lower limb of two legs were investigated. The increment of insoles was placed on the right leg to represent the long leg.

    RESULTS: The results suggest that the mean contact forces for all joints in the short leg were increased as the increment level increased. On the contrary, the mean contact forces in the long leg decreased when the LLD level increased. Among these four joints, JCF in hip shows a positive increment based on the ASI value. Means that hip shows the most affected joint as the LLD level increase.

    CONCLUSIONS: The result obtained in this study might help clinicians treat patients with a structural LLD for treatment plan including surgical intervention.

    Matched MeSH terms: Biomechanical Phenomena
  5. Mat S, Tan MP, Kamaruzzaman SB, Ng CT
    Age Ageing, 2015 Jan;44(1):16-24.
    PMID: 25149678 DOI: 10.1093/ageing/afu112
    INTRODUCTION: osteoarthritis (OA) of knee has been reported as a risk factor for falls and reduced balance in the elderly. This systematic review evaluated the effectiveness of physical therapies in improving balance and reducing falls risk among patients with knee OA.
    METHODS: a computerised search was performed to identify relevant studies up to November 2013. Two investigators identified eligible studies and extracted data independently. The quality of the included studies was assessed by the PeDro score.
    RESULTS: a total of 15 randomised controlled trials involving 1482 patients were identified. The mean PeDro score was 7. The pooled standardised mean difference in balance outcome for strength training = 0.3346 (95% CI: 0.3207-0.60, P = 0.01 < 0.00001, P for heterogeneity = 0.85, I(2) = 0%). Tai Chi = 0.7597 (95% CI: 0.5130-1.2043, P<=0.0014, P for heterogeneity = 0.26, I(2) = 0%) and aerobic exercises = 0.6880 (95% CI: 0.5704-1.302, P < 0.00001, P for heterogeneity = 0.71, I(2) = 0%). While pooled results for falls risk outcomes in, strength training, Tai chi and aerobics also showed a significant reduction in reduced risk of falls significantly with pooled result 0.55 (95% CI: 0.41-0.68, P < 0.00001, P for heterogeneity = 0.39, I(2) = 6%).
    CONCLUSION: strength training, Tai Chi and aerobics exercises improved balance and falls risk in older individuals with knee OA, while water-based exercises and light treatment did not significantly improve balance outcomes. Strength training, Tai Chi and aerobics exercises can therefore be recommended as falls prevention strategies for individuals with OA. However, a large randomised controlled study using actual falls outcomes is recommended to determine the appropriate dosage and to measure the potential benefits in falls reduction.
    KEYWORDS: Tai Chi; elderly; exercises; falls; older people; osteoarthritis
    Matched MeSH terms: Biomechanical Phenomena
  6. Ng CT, Tan MP
    Age Ageing, 2013 Sep;42(5):561-6.
    PMID: 23864423 DOI: 10.1093/ageing/aft070
    Osteoarthritis and falls are common conditions affecting older individuals which are associated with disability and escalating health expenditure. It has been widely assumed that osteoarthritis is an established risk factor for falls in older people. The relationship between osteoarthritis and falls has, quite surprisingly, not been adequately elucidated, and published reports have been conflicting. Our review of the existing literature has found limited evidence supporting the current assumption that the presence of osteoarthritis is associated with increased risk of falls with suggestions that osteoarthritis may actually be protective against falls related fractures. In addition, joint arthroplasty appears to increase the risk of falls in individuals with osteoarthritis.
    Matched MeSH terms: Biomechanical Phenomena
  7. Eshraghi A, Abu Osman NA, Gholizadeh H, Ali S, Abas WA
    Am J Phys Med Rehabil, 2015 Jan;94(1):1-10.
    PMID: 24919079 DOI: 10.1097/PHM.0000000000000134
    This study aimed to compare the effects of different suspension methods on the interface stress inside the prosthetic sockets of transtibial amputees when negotiating ramps and stairs.
    Matched MeSH terms: Biomechanical Phenomena
  8. Abd Razak NA, Abu Osman NA, Kamyab M, Wan Abas WA, Gholizadeh H
    Am J Phys Med Rehabil, 2014 May;93(5):437-44.
    PMID: 24429510 DOI: 10.1097/PHM.0b013e3182a51fc2
    This report compares wrist supination and pronation and flexion and extension movements with the common body-powered prosthesis and a new biomechatronics prosthesis with regard to patient satisfaction and problems experienced with the prosthesis. Fifteen subjects with traumatic transradial amputation who used both prosthetic systems participated in this study. Each subject completed two questionnaires to evaluate their satisfaction and problems experienced with the two prosthetic systems. Satisfaction and problems with the prosthetic's wrist movements were analyzed in terms of the following: supination and pronation; flexion and extension; appearance; sweating; wounds; pain; irritation; pistoning; smell; sound; durability; and the abilities to open a door, hold a cup, and pick up or place objects. This study revealed that the respondents were more satisfied with the biomechatronics wrist prosthesis with regard to supination and pronation, flexion and extension, pain, and the ability to open a door. However, satisfaction with the prosthesis showed no significant differences in terms of sweating, wounds, irritation, pistoning, smell, sound, and durability. The abilities to hold a cup and pick up or place an object were significantly better with the body-powered prosthesis. The results of the survey suggest that satisfaction and problems with wrist movements in persons with transradial amputation can be improved with a biomechatronics wrist prosthesis compared with the common body-powered prosthesis.
    Matched MeSH terms: Biomechanical Phenomena
  9. Wan Ab Naim WN, Ganesan P, Al Abed A, Lim E
    PMID: 23365977 DOI: 10.1109/EMBC.2012.6346016
    The effects of curvature and tapering on the flow progression in the aorta were studied using numerical simulations on a realistic geometrical model of the aorta and three different versions of the ideal aorta models. The results showed that tapering increases velocity magnitude and wall shear stress while local curvatures affect the skewness of the velocity profile, the thickness of the boundary layer as well as the recirculation regions. Wall shear stress distribution in the aorta serves as an important determinant in the progression of arterial disease.
    Matched MeSH terms: Biomechanical Phenomena
  10. Kouhi M, Jayarama Reddy V, Ramakrishna S
    Appl Biochem Biotechnol, 2019 Jun;188(2):357-368.
    PMID: 30456599 DOI: 10.1007/s12010-018-2922-0
    Bioceramic nanoparticles with high specific surface area often tend to agglomerate in the polymer matrix, which results in undesirable mechanical properties of the composites and poor cell spreading and attachment. In the present work, bredigite (BR) nanoparticles were modified with an organosilane coupling agent, 3-glycidoxypropyltrimethoxysilane (GPTMS), to enhance its dispersibility in the polymer matrix. The polyhydroxybutyrate-co-hydroxyvaletare (PHBV) nanofibrous scaffolds containing either bredigite or GPTMS-modified bredigite (G-BR) nanoparticles were fabricated using electrospinning technique and characterized using scanning electron microscopy, transmission electron microscopy, and tensile strength. Results demonstrated that modification of bredigite was effective in enhancing nanoparticle dispersion in the PHBV matrix. PHBV/G-BR scaffold showed improved mechanical properties compared to PHBV and PHBV/BR, especially at the higher concentration of nanoparticles. In vitro bioactivity assay performed in the simulated body fluid (SBF) indicated that composite PHBV scaffolds were able to induce the formation of apatite deposits after incubation in SBF. From the results of in vitro biological assay, it is concluded that the synergetic effect of BR and GPTMS provided an enhanced hFob cells attachment and proliferation. The developed PHBV/G-BR nanofibrous scaffolds may be considered for application in bone tissue engineering.
    Matched MeSH terms: Biomechanical Phenomena
  11. Abdul Yamin NAA, Basaruddin KS, Salleh AF, Salim MS, Wan Muhamad WZA
    Appl Bionics Biomech, 2021;2021:8842591.
    PMID: 33603827 DOI: 10.1155/2021/8842591
    Objective: The aim of this study was to investigate the effects of surface stiffness on multisegment foot kinematics and temporal parameters during running.

    Methods: Eighteen male subjects ran on three different surfaces (i.e., concrete, artificial grass, and rubber) in both heeled running shoes (HS) and minimal running shoes (MS). Both these shoes had dissimilar sole profiles. The heeled shoes had a higher sole at the heel, a thick base, and arch support, whereas the minimal shoes had a flat base sole. Indeed, the studied biomechanical parameters responded differently in the different footwear during running. Subjects ran in recreational mode speed while 3D foot kinematics (i.e., joint rotation and peak medial longitudinal arch (MLA) angle) were determined using a motion capture system (Qualysis, Gothenburg, Sweden). Information on stance time and plantar fascia strain (PFS) was also collected.

    Results: Running on different surface stiffness was found to significantly affect the peak MLA angles and stance times for both HS and MS conditions. However, the results showed that the joint rotation angles were not sensitive to surface stiffness. Also, PFS showed no relationship with surface stiffness, as the results were varied as the surface stiffness was changed.

    Conclusion: The surface stiffness significantly contributed towards the effects of peak MLA angle and stance time. These findings may enhance the understanding of biomechanical responses on various running surfaces stiffness in different shoe conditions.

    Matched MeSH terms: Biomechanical Phenomena
  12. Azizan NA, Basaruddin KS, Salleh AF
    Appl Bionics Biomech, 2018;2018:5156348.
    PMID: 30116295 DOI: 10.1155/2018/5156348
    Various studies have examined body posture stability, including postural sway and associated biomechanical parameters, to assess the severity effects of leg length discrepancy (LLD). However, various viewpoints have been articulated on the results of these studies because of certain drawbacks in the comprehensive analysis of the effect of variations in LLD magnitude. Therefore, this systematic review was performed to help focus on the current findings to help identify which biomechanical parameters are most relevant, commonly used, and able to distinguish and/or have specific clinical relevance to the effect of variations in LLD magnitude during static (standing) and dynamic (walking) conditions. Several electronic databases containing studies from the year 1983 to 2016 (Scopus, ScienceDirect, PubMed, PMC, and ProQuest) were obtained in our literature search. The search process yielded 22 published articles that fulfilled our criteria. We found most of the published data that we analyzed to be inconsistent, and very little data was obtained on the correlation between LLD severity and changes in body posture stability during standing and walking. However, the results of the present review study are in line with previous observational studies, which describe asymmetry in the lower limbs corresponding to biomechanical parameters such as gait kinematics, kinetics, and other parameters described during static (standing) postural balance. In future investigations, we believe that it might be useful to use and exploit other balance-related factors that may potentially influence body posture stability.
    Matched MeSH terms: Biomechanical Phenomena
  13. Harith HH, Mohd MF, Nai Sowat S
    Appl Ergon, 2021 Sep;95:103455.
    PMID: 33991852 DOI: 10.1016/j.apergo.2021.103455
    Manual harvesting is still prevalent in the agricultural industry. Accordingly, it is one of the largest contributors toward work-related musculoskeletal disorder. The cutting task in oil palm harvesting uses a long pole and involves repetitive and forceful motion of the upper limbs. Exoskeleton technology is increasingly explored to assist manual tasks performance in manufacturing and heavy industries, mainly for reducing discomfort and injuries, and improving productivity. This paper reports an initial investigation on the feasibility of using an upper limb exoskeleton to assist oil palm harvesting tasks. Previous studies highlighted that exoskeletons for agricultural activities should be adaptable to changing field tasks, tools and equipment. The immediate difference in the activity of three muscles were analyzed for a range of harvesting-simulated tasks. Lower activities were observed for tasks involving overhead work when using the prototype. Nevertheless, users' feedback highlighted that its design should be optimized for better acceptance.
    Matched MeSH terms: Biomechanical Phenomena
  14. Kondo E, Merican AM, Yasuda K, Amis AA
    Arthroscopy, 2014 Mar;30(3):335-43.
    PMID: 24581258 DOI: 10.1016/j.arthro.2013.12.003
    The purpose of this study was to clarify the changes in the kinematics of the knee that result from isolated deficiency of the anteromedial (AM) or posterolateral (PL) bundle.
    Matched MeSH terms: Biomechanical Phenomena
  15. Abbas SS, Nasif MS, Al-Waked R, Meor Said MA
    Artif Organs, 2020 Feb;44(2):E20-E39.
    PMID: 31378963 DOI: 10.1111/aor.13536
    Platelet activation induced by shear stresses and non-physiological flow field generated by bileaflet mechanical heart valves (BMHVs) leads to thromboembolism, which can cause fatal consequences. One of the causes of platelet activation could be intermittent regurgitation, which arises due to asynchronous movement and rebound of BMHV leaflets during the valve closing phase. In this numerical study, the effect of intermittent regurgitation on the platelet activation potential of BMHVs was quantified by modeling a BMHV in the straight and anatomic aorta at implantation tilt angles 0°, 5°, 10°, and 20°. A fully implicit Arbitrary Lagrangian-Eulerian-based Fluid-Structure Interaction formulation was adopted with blood modeled as a multiphase, non-Newtonian fluid. Results showed that the intermittent regurgitation and consequently the platelet activation level increases with the increasing implantation tilt of BMHV. For the straight aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 20° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 8.5°, 3°, and 0°, respectively. For the anatomic aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 24° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 14°, 10°, and 7°, respectively. For all the implantation orientations of BMHVs, intermittent regurgitation and platelet activation were always higher in the anatomic aorta than in the straight aorta. The study concludes that the pivot axis of BMHV must be implanted parallel to the aortic root's curvature to minimize intermittent regurgitation and platelet activation.
    Matched MeSH terms: Biomechanical Phenomena
  16. Alkhatib SE, Tarlochan F, Mehboob H, Singh R, Kadirgama K, Harun WSBW
    Artif Organs, 2019 Jul;43(7):E152-E164.
    PMID: 30805945 DOI: 10.1111/aor.13444
    The mismatch between stiffness of the femoral dense stem and host bone causes complications to patients, such as aseptic loosening and bone resorption. Three-dimensional finite-element models of homogeneous porous (HGP) and functionally graded porous (FGP) stems incorporating body-centered cubic (BCC) structures are proposed in this article as an alternative to the dense stems. The relationship between the porosity and strut thickness of the BCC structure was developed to construct the finite-element models. Three levels of porosities (20%, 50%, and 80%) were modeled in HGP and FGP stems. The porosity of the stems was decreased distally according to the sigmoid function (n = 0.1, n = 1 and n = 10) with 3 grading exponents. The results showed that FGP stems transferred 120%-170% higher stresses to the femur (Gruen zone 7) as compared to the solid stem. Conversely, the stresses in HGP and FGP stems were 12%-34% lower than the dense stem. The highest micromotions (105-147 µm) were observed for stems of 80% overall porosity, and the lowest (42-46 µm) was for stems of 20% overall porosity. Finally, FGP stems with a grading exponent of n = 10 resulted in an 11%-28% reduction in micromotions.
    Matched MeSH terms: Biomechanical Phenomena
  17. Ahamed NU, Sundaraj K, Ahmad B, Rahman M, Ali MA, Islam MA
    Australas Phys Eng Sci Med, 2014 Mar;37(1):83-95.
    PMID: 24477560 DOI: 10.1007/s13246-014-0245-1
    Cricket bowling generates forces with torques on the upper limb muscles and makes the biceps brachii (BB) muscle vulnerable to overuse injury. The aim of this study was to investigate whether there are differences in the amplitude of the EMG signal of the BB muscle during fast and spin delivery, during the seven phases of both types of bowling and the kinesiological interpretation of the bowling arm for muscle contraction mechanisms during bowling. A group of 16 male amateur bowlers participated in this study, among them 8 fast bowlers (FB) and 8 spin bowlers (SB). The root mean square (EMGRMS), the average sEMG (EMGAVG), the maximum peak amplitude (EMGpeak), and the variability of the signal were calculated using the coefficient of variance (EMGCV) from the BB muscle of each bowler (FB and SB) during each bowling phase. The results demonstrate that, (i) the BB muscle is more active during FB than during SB, (ii) the point of ball release and follow-through generated higher signals than the other five movements during both bowling categories, (iii) the BB muscle variability is higher during SB compared with FB, (iv) four statistically significant differences (p<0.05) found between the bowling phases in fast bowling and three in spin bowling, and (v) several arm mechanics occurred for muscle contraction. There are possible clinical significances from the outcomes; like, recurring dynamic contractions on BB muscle can facilitate to clarify the maximum occurrence of shoulder pain as well as biceps tendonitis those are medically observed in professional cricket bowlers, and treatment methods with specific injury prevention programmes should focus on the different bowling phases with the maximum muscle effect. Finally, these considerations will be of particular importance in assessing different physical therapy on bowler's muscle which can improve the ball delivery performance and stability of cricket bowlers.
    Matched MeSH terms: Biomechanical Phenomena/physiology
  18. Tam YJ, Allaudin ZN, Lila MA, Bahaman AR, Tan JS, Rezaei MA
    BMC Biotechnol, 2012;12:70.
    PMID: 23039947 DOI: 10.1186/1472-6750-12-70
    Cell disruption strategies by high pressure homogenizer for the release of recombinant Hepatitis B surface antigen (HBsAg) from Pichia pastoris expression cells were optimized using response surface methodology (RSM) based on the central composite design (CCD). The factors studied include number of passes, biomass concentration and pulse pressure. Polynomial models were used to correlate the above mentioned factors to project the cell disruption capability and specific protein release of HBsAg from P. pastoris cells.
    Matched MeSH terms: Biomechanical Phenomena
  19. Mohd Effendy N, Abdullah S, Yunoh MF, Shuid AN
    BMC Complement Altern Med, 2015 Mar 12;15:58.
    PMID: 25887391 DOI: 10.1186/s12906-015-0567-x
    BACKGROUND: Post-menopausal osteoporosis has long been treated and prevented by estrogen replacement therapy (ERT). Despite its effectiveness, ERT is associated with serious adverse effects. Labisia pumila var. alata (LP) is a herb with potential as an alternative agent to ERT due to its phytoestrogenic, antioxidative and anti-inflammatory effects on bone. This study aimed to determine the effects of LP supplementation on bone biomechanical strength of postmenopausal osteoporosis rat model.

    METHODS: Ninety-six female Sprague-Dawley rats aged 4 to 5 months old were randomly divided into six groups; six rats in the baseline group (BL) and eighteen rats in each group of; Sham- operated (Sham), ovariectomised control (OVXC) and ovariectomised with daily oral gavages of Premarin at 64.5 μg/kg (ERT), LP at 20 mg/kg (LP20) and LP at 100 mg/kg (LP100) respectively. These groups were subdivided into three, six and nine weeks of treatment periods. Rats in BL group were euthanized before the start of the study, while other rats were euthanized after completion of their treatments. Femora were dissected out for biomechanical strength analysis using Instron Universal Model 5848 Micro Tester.

    RESULTS: OVXC group showed deterioration in the bone biomechanical strength with time. Both ERT and LP supplemented rats showed improvements in bone strength parameters such as maximum load, displacement, stiffness, stress, and Young Modulus. The most improved bone strength was seen in rats given LP at the dose of 100 mg/kg for nine weeks.

    CONCLUSION: LP supplementation at 100 mg/kg was more effective than ERT in reversing ovariectomy-induced bone biomechanical changes.
    Matched MeSH terms: Biomechanical Phenomena
  20. Choy WJ, Phan K, Diwan AD, Ong CS, Mobbs RJ
    BMC Musculoskelet Disord, 2018 Aug 16;19(1):290.
    PMID: 30115053 DOI: 10.1186/s12891-018-2213-5
    BACKGROUND: Lumbar intervertebral disc herniation is a common cause of lower back and leg pain, with surgical intervention (e.g. discectomy to remove the herniated disc) recommended after an appropriate period of conservative management, however the existing or increased breach of the annulus fibrosus persists with the potential of reherniation. Several prosthesis and techniques to reduce re-herniation have been proposed including implantation of an annular closure device (ACD) - Barricaid™ and an annular tissue repair system (AR) - Anulex-Xclose™. The aim of this meta-analysis is to assist surgeons determine a potential approach to reduce incidences of recurrent lumbar disc herniation and assess the current devices regarding their outcomes and complications.

    METHODS: Four electronic full-text databases were systematically searched through September 2017. Data including outcomes of annular closure device/annular repair were extracted. All results were pooled utilising meta-analysis with weighted mean difference and odds ratio as summary statistics.

    RESULTS: Four studies met inclusion criteria. Three studies reported the use of Barricaid (ACD) while one study reported the use of Anulex (AR). A total of 24 symptomatic reherniation were reported among 811 discectomies with ACD/AR as compared to 51 out of 645 in the control group (OR: 0.34; 95% CI: 0.20,0.56; I2 = 0%; P 

    Matched MeSH terms: Biomechanical Phenomena
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links