Displaying publications 1 - 20 of 249 in total

Abstract:
Sort:
  1. Panagiotopoulou O, Iriarte-Diaz J, Wilshin S, Dechow PC, Taylor AB, Mehari Abraha H, et al.
    Zoology (Jena), 2017 10;124:13-29.
    PMID: 29037463 DOI: 10.1016/j.zool.2017.08.010
    Finite element analysis (FEA) is a commonly used tool in musculoskeletal biomechanics and vertebrate paleontology. The accuracy and precision of finite element models (FEMs) are reliant on accurate data on bone geometry, muscle forces, boundary conditions and tissue material properties. Simplified modeling assumptions, due to lack of in vivo experimental data on material properties and muscle activation patterns, may introduce analytical errors in analyses where quantitative accuracy is critical for obtaining rigorous results. A subject-specific FEM of a rhesus macaque mandible was constructed, loaded and validated using in vivo data from the same animal. In developing the model, we assessed the impact on model behavior of variation in (i) material properties of the mandibular trabecular bone tissue and teeth; (ii) constraints at the temporomandibular joint and bite point; and (iii) the timing of the muscle activity used to estimate the external forces acting on the model. The best match between the FEA simulation and the in vivo experimental data resulted from modeling the trabecular tissue with an isotropic and homogeneous Young's modulus and Poisson's value of 10GPa and 0.3, respectively; constraining translations along X,Y, Z axes in the chewing (left) side temporomandibular joint, the premolars and the m1; constraining the balancing (right) side temporomandibular joint in the anterior-posterior and superior-inferior axes, and using the muscle force estimated at time of maximum strain magnitude in the lower lateral gauge. The relative strain magnitudes in this model were similar to those recorded in vivo for all strain locations. More detailed analyses of mandibular strain patterns during the power stroke at different times in the chewing cycle are needed.
    Matched MeSH terms: Biomechanical Phenomena
  2. Labens R, Khairuddin NH, Murray M, Jermyn K, Ahmad RS
    Vet Surg, 2019 Jan;48(1):96-104.
    PMID: 30403407 DOI: 10.1111/vsu.13123
    OBJECTIVE: To assess fracture gap reduction and stability of linear vs triangular 4.5-mm lag screw repair of experimental, uniarticular, and complete forelimb proximal phalanx (P1) fractures.

    STUDY DESIGN: Experimental.

    SAMPLE POPULATION: Fourteen equine cadaver limbs/horses.

    METHODS: Simulated fractures were repaired with 2 lag screws under 4-Nm insertion torque (linear repair). Computed tomography (CT) imaging was performed with the leg unloaded and loaded to forces generated while walking. The fracture repair was revised to include 3 lag screws placed with the same insertion torque (triangular repair) prior to CT. The width of the fracture gap was assessed qualitatively by 2 observers and graded on the basis of gap measurements relative to the average voxel size at dorsal, mid, and palmar P1 sites. Interobserver agreement was assessed with Cohen's κ. The effect of repair type, loading condition, and measurement site on fracture gap grades was evaluated by using Kendall's τ-b correlation coefficients and paired nonparametric tests. Significance was set at P ≤ .05.

    RESULTS: Agreement between loading and fracture gap widening was fair in triangular (κ = 0.53) and excellent in linear (κ = 0.81) repairs. Loading resulted in fracture gap distraction in linear repairs (Plinear  = .008). Triangular repairs reduced fractures better irrespective of loading (Punloaded  = .003; Ploaded  

    Matched MeSH terms: Biomechanical Phenomena
  3. Katijjahbe MA, Denehy L, Granger CL, Royse A, Royse C, Bates R, et al.
    Trials, 2017 06 23;18(1):290.
    PMID: 28645301 DOI: 10.1186/s13063-017-1974-8
    BACKGROUND: The routine implementation of sternal precautions to prevent sternal complications that restrict the use of the upper limbs is currently worldwide practice following a median sternotomy. However, evidence is limited and drawn primarily from cadaver studies and orthopaedic research. Sternal precautions may delay recovery, prolong hospital discharge and be overly restrictive. Recent research has shown that upper limb exercise reduces post-operative sternal pain and results in minimal micromotion between the sternal edges as measured by ultrasound. The aims of this study are to evaluate the effects of modified sternal precautions on physical function, pain, recovery and health-related quality of life after cardiac surgery.

    METHODS/DESIGN: This study is a phase II, double-blind, randomised controlled trial with concealed allocation, blinding of patients and assessors, and intention-to-treat analysis. Patients (n = 72) will be recruited following cardiac surgery via a median sternotomy. Sample size calculations were based on the minimal important difference (two points) for the primary outcome: Short Physical Performance Battery. Thirty-six participants are required per group to counter dropout (20%). All participants will be randomised to receive either standard or modified sternal precautions. The intervention group will receive guidelines encouraging the safe use of the upper limbs. Secondary outcomes are upper limb function, pain, kinesiophobia and health-related quality of life. Descriptive statistics will be used to summarise data. The primary hypothesis will be examined by repeated-measures analysis of variance to evaluate the changes from baseline to 4 weeks post-operatively in the intervention arm compared with the usual-care arm. In all tests to be conducted, a p value <0.05 (two-tailed) will be considered statistically significant, and confidence intervals will be reported.

    DISCUSSION: The Sternal Management Accelerated Recovery Trial (S.M.A.R.T.) is a two-centre randomised controlled trial powered and designed to investigate whether the effects of modifying sternal precautions to include the safe use of the upper limbs and trunk impact patients' physical function and recovery following cardiac surgery via median sternotomy.

    TRIAL REGISTRATION: Australian and New Zealand Clinical Trials Registry identifier: ACTRN12615000968572 . Registered on 16 September 2015 (prospectively registered).

    Matched MeSH terms: Biomechanical Phenomena
  4. Hoque ME, San WY, Wei F, Li S, Huang MH, Vert M, et al.
    Tissue Eng Part A, 2009 Oct;15(10):3013-24.
    PMID: 19331580 DOI: 10.1089/ten.TEA.2008.0355
    Synthetic polymers have attracted much attention in tissue engineering due to their ability to modulate biomechanical properties. This study investigated the feasibility of processing poly(epsilon-caprolactone) (PCL) homopolymer, PCL-poly(ethylene glycol) (PEG) diblock, and PCL-PEG-PCL triblock copolymers into three-dimensional porous scaffolds. Properties of the various polymers were investigated by dynamic thermal analysis. The scaffolds were manufactured using the desktop robot-based rapid prototyping technique. Gross morphology and internal three-dimensional structure of scaffolds were identified by scanning electron microscopy and micro-computed tomography, which showed excellent fusion at the filament junctions, high uniformity, and complete interconnectivity of pore networks. The influences of process parameters on scaffolds' morphological and mechanical characteristics were studied. Data confirmed that the process parameters directly influenced the pore size, porosity, and, consequently, the mechanical properties of the scaffolds. The in vitro cell culture study was performed to investigate the influence of polymer nature and scaffold architecture on the adhesion of the cells onto the scaffolds using rabbit smooth muscle cells. Light, scanning electron, and confocal laser microscopy showed cell adhesion, proliferation, and extracellular matrix formation on the surface as well as inside the structure of both scaffold groups. The completely interconnected and highly regular honeycomb-like pore morphology supported bridging of the pores via cell-to-cell contact as well as production of extracellular matrix at later time points. The results indicated that the incorporation of hydrophilic PEG into hydrophobic PCL enhanced the overall hydrophilicity and cell culture performance of PCL-PEG copolymer. However, the scaffold architecture did not significantly influence the cell culture performance in this study.
    Matched MeSH terms: Biomechanical Phenomena
  5. Anuar MA, Todo M, Nagamine R, Hirokawa S
    ScientificWorldJournal, 2014;2014:586921.
    PMID: 25133247 DOI: 10.1155/2014/586921
    The primary objective of this study is to distinguish between mobile bearing and fixed bearing posterior stabilized knee prostheses in the mechanics performance using the finite element simulation. Quantifying the relative mechanics attributes and survivorship between the mobile bearing and the fixed bearing prosthesis remains in investigation among researchers. In the present study, 3-dimensional computational model of a clinically used mobile bearing PS type knee prosthesis was utilized to develop a finite element and dynamic simulation model. Combination of displacement and force driven knee motion was adapted to simulate a flexion motion from 0° to 135° with neutral, 10°, and 20° internal tibial rotation to represent deep knee bending. Introduction of the secondary moving articulation in the mobile bearing knee prosthesis has been found to maintain relatively low shear stress during deep knee motion with tibial rotation.
    Matched MeSH terms: Biomechanical Phenomena
  6. El-Sayed AM, Hamzaid NA, Abu Osman NA
    ScientificWorldJournal, 2014;2014:297431.
    PMID: 25110727 DOI: 10.1155/2014/297431
    Several studies have presented technological ensembles of active knee systems for transfemoral prosthesis. Other studies have examined the amputees' gait performance while wearing a specific active prosthesis. This paper combined both insights, that is, a technical examination of the components used, with an evaluation of how these improved the gait of respective users. This study aims to offer a quantitative understanding of the potential enhancement derived from strategic integration of core elements in developing an effective device. The study systematically discussed the current technology in active transfemoral prosthesis with respect to its functional walking performance amongst above-knee amputee users, to evaluate the system's efficacy in producing close-to-normal user performance. The performances of its actuator, sensory system, and control technique that are incorporated in each reported system were evaluated separately and numerical comparisons were conducted based on the percentage of amputees' gait deviation from normal gait profile points. The results identified particular components that contributed closest to normal gait parameters. However, the conclusion is limitedly extendable due to the small number of studies. Thus, more clinical validation of the active prosthetic knee technology is needed to better understand the extent of contribution of each component to the most functional development.
    Matched MeSH terms: Biomechanical Phenomena
  7. Pirouzi G, Abu Osman NA, Eshraghi A, Ali S, Gholizadeh H, Wan Abas WA
    ScientificWorldJournal, 2014;2014:849073.
    PMID: 25197716 DOI: 10.1155/2014/849073
    Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressure measurement, and socket biomechanics. Literature was searched to find related keywords with transtibial amputation, socket-residual limb interface, socket measurement, socket design, modeling, computational modeling, and suspension system. In accordance with the selection criteria, 19 articles were selected for further analysis. It was revealed that pressure and stress have been studied in the last decaeds, but quantitative evaluations remain inapplicable in clinical settings. This study also illustrates prevailing systems, which may facilitate improvements in socket design for improved quality of life for individuals ambulating with transtibial prosthesis. It is hoped that the review will better facilitate the understanding and determine the clinical relevance of quantitative evaluations.
    Matched MeSH terms: Biomechanical Phenomena
  8. Ahmad M, Uzir Wahit M, Abdul Kadir MR, Mohd Dahlan KZ
    ScientificWorldJournal, 2012;2012:474851.
    PMID: 22666129 DOI: 10.1100/2012/474851
    Ultrahigh-molecular-weight polyethylene/high-density polyethylene (UHMWPE/HDPE) blends prepared using polyethylene glycol PEG as the processing aid and hydroxyapatite (HA) as the reinforcing filler were found to be highly processable using conventional melt blending technique. It was demonstrated that PEG reduced the melt viscosity of UHMWPE/HDPE blend significantly, thus improving the extrudability. The mechanical and bioactive properties were improved with incorporation of HA. Inclusion of HA from 10 to 50 phr resulted in a progressive increase in flexural strength and modulus of the composites. The strength increment is due to the improvement on surface contact between the irregular shape of HA and polymer matrix by formation of mechanical interlock. The HA particles were homogenously distributed even at higher percentage showed improvement in wetting ability between the polymer matrix and HA. The inclusion of HA enhanced the bioactivity properties of the composite by the formation of calcium phosphate (Ca-P) precipitates on the composite surface as proven from SEM and XRD analysis.
    Matched MeSH terms: Biomechanical Phenomena
  9. Jamal J, Roebuck MM, Lee SY, Frostick SP, Abbas AA, Merican AM, et al.
    Int J Biochem Cell Biol, 2020 09;126:105800.
    PMID: 32673644 DOI: 10.1016/j.biocel.2020.105800
    OBJECTIVES: To compare mechanobiological response of synovial fibroblasts (SFb) from OA patient cohorts under mechanical load and inflammatory stressors for better understanding of SFb homeostatic functions.

    METHODS: Primary SFb isolated from knee synovium of OA obese (OA-ob:SFb), OA-pre-obese (OA-Pob:SFb), non-OA arthroscopic (scope:SFb), and non-OA arthroscopic with cartilage damage (scope-CD:SFb) were exposed to OA-conditioned media (OACM), derived from OA obese (OA-ob:CM), OA-pre-obese (OA-Pob:CM), and mechanical stretch at either 0 %, 6 % or 10 % for 24 h. Differences in the mRNA levels of genes involved in extracellular matrix production, inflammation and secretory activity were measured.

    RESULTS: Despite the significant BMI differences between the OA-ob and OA-Pob groups, OA-Pob has more patients with underlying dyslipidaemia, and low-grade synovitis with higher levels of secreted proteins, CXCL8, COL4A1, CCL4, SPARC and FGF2 in OA-Pob:CM. All primary SFb exhibited anti-proliferative activity with both OA-CM. Mechanical stretch stimulated lubricin production in scope:SFb, higher TGFβ1 and COL1A1 expressions in scope-CD:SFb. OA-Pob:CM stimulated greater detrimental effects than the OA-ob:CM, with higher pro-inflammatory cytokines, IL1β, IL6, COX2 and proteases such as aggrecanases, ADAMTS4 and ADAMTS5, and lower ECM matrix, COL1A1 expressions in all SFb. OA-ob:SFb were unresponsive but expressed higher pro-inflammatory cytokines under OA-Pob:CM treatment.

    CONCLUSION: Both mechanical and inflammatory stressors regulate SFb molecular functions with heterogeneity in responses that are dependent on their pathological tissue of origins. While mechanical stretch promotes a favorable effect with enhanced lubricin production in scope:SFb and TGFβ1 and COL1A1 in scope-CD:SFb, the presence of excessively high OA-associated inflammatory mediators in OA-Pob:CM, predominantly SPARC, CXCL8 and FGF2 drive all SFb regardless of pathology, towards greater pro-inflammatory activities.

    Matched MeSH terms: Biomechanical Phenomena
  10. Hoque ME, Zainal NH, Syarif J
    Med J Malaysia, 2008 Jul;63 Suppl A:91-2.
    PMID: 19024999
    This study aims at investigating the mechanical properties of the contemporary metallic bone plates determining the effect of their length, width and thickness on the properties and compares with the composite bone plates. Three-points bending test was performed over the stainless steel plates of different length, width and thickness. The test results showed that different plates had different mechanical properties. However, the properties are still much higher than that of particular bones intended to be treated. Therefore, the reported findings strongly encourage developing composite bone plates with biocompatible polymers/fibers that would have modulated properties according to the requirements.
    Matched MeSH terms: Biomechanical Phenomena
  11. Mustaffa R, Besar I, Andanastuti M
    Med J Malaysia, 2008 Jul;63 Suppl A:95-6.
    PMID: 19025001
    In this study, porous hydroxyapatite (HA) samples were fabricated via sponge techniques with the aid of sago as part of the binder mixture. Development processes for the production of porous bone graft substitutes are studied using polyurethane sponge. To obtain the optimum amount of binder for successful fabrication of porous HA were done. Initially, porous HA powder was synthesized using calcium hydroxide and orthorphosphoric acid. Meanwhile, sago was mixed with PVA in a certain ratio to be used as binder for preparing the porous HA. After a series of investigative tests were conducted to characterize the sintered samples, the use of the sago and polymeric mixture was found to successfully aid the fabrication of porous HA samples. In this investigation, comparison of physical and mechanical characteristics between samples prepared using difference techniques was made.
    Matched MeSH terms: Biomechanical Phenomena
  12. Azlan AM, Mohammad AR, Ariffin AK
    Med J Malaysia, 2005 Jul;60 Suppl C:30-4.
    PMID: 16381280 MyJurnal
    This finite element analysis is aimed at comparing relative stiffness of three different posterior instrumentation constructs: the Hospital Universiti Kebangsaan Malaysia Spinal Instrumentation System (HUKM-SIS), the Cotrell-Dubousset Instrumentation (CDI) and Harrington Instrumentation System (HIS), used in the treatment of adolescent idiopathic scoliosis (AIS). The constructs were tested under various loads using MSC Patran 2001 r2a. Under increasing flexion loads, there was a linearly corresponding increase in deflection magnitudes for all constructs on the load-deflection curve. The CDI was the stiffest construct under axial, forward flexion and extension loads, followed by the HUKM-SIS and HIS. Under lateral bending loads, the HUKM-SIS construct was the stiffest followed by CDI and HIS. The HUKM-SIS construct was stiffer than HIS under torsional loads. We conclude that multiple pedicle screws increase the stiffness of posterior instrumentation constructs under all loads and inter-segmental spinous processes wiring increase the stiffness against lateral bending.
    Matched MeSH terms: Biomechanical Phenomena
  13. Loqman MY, Wong CM, Hair-Bejo M, Zuki AB, Hafeez YM
    Med J Malaysia, 2004 May;59 Suppl B:113-4.
    PMID: 15468844
    A study was conducted to investigate the effectiveness of freeze-dried bovine pericardium (FDBP) as a biomaterial in diaphragmatic herniorrhapy in dogs. Eight adult dogs were randomly selected and divided into two equal groups. In FDBP group, a diaphragmatic defect was induced and repaired with an identical size of FDBP. In the control group, a diaphragmatic wall was incised at three-side border creating a flap and sutured. Grossly, only mild intrathoracic adhesion was observed for most of the animals, and no herniation occured. Microscopically, the biomaterial incorporated into the host's tissue by ingrowth of young muscle fiber and massive new blood vessel formation in between the fibrous tissue.
    Matched MeSH terms: Biomechanical Phenomena
  14. Lai KL, Roziyanna A, Ogunniyi DS, Zainal AM, Azlan AA
    Med J Malaysia, 2004 May;59 Suppl B:61-2.
    PMID: 15468819
    Various blend ratios of high-density polyethylene (HDPE) and ultra high molecular weight polyethylene (UHMWPE) were prepared with the objective of determining their suitability as biomaterials. In the unfilled state, a blend of 50/50 (HDPE/UHMWPE) ratio by weight was found to yield optimum properties in terms of processability and mechanical properties. Hydroxyapatite (HA) was compounded with the optimum blend ratio. The effects of HA loading, varied from 0 to 50wt% for both filled and unfilled blends were tested for mechanical properties. It was found that the inclusion of HA in the blend led to a remarkable improvement of mechanical properties compared to the unfilled blend. In order to improve the bonding between the polymer blend and the filler, the HA used was chemically treated with a coupling agent known as 3-(trimethoxysiyl) propyl methacrylate and the treated HA was mixed into the blend. The effect of mixing the blend with silane-treated HA also led to an overall improvement of mechanical properties.
    Matched MeSH terms: Biomechanical Phenomena
  15. Nather A
    Med J Malaysia, 2004 May;59 Suppl B:37-8.
    PMID: 15468807
    Matched MeSH terms: Biomechanical Phenomena
  16. Darmawati MY, Ismarul N, Fuad Y, Fazan F
    Med J Malaysia, 2004 May;59 Suppl B:27-8.
    PMID: 15468802
    Linear polymers have been commonly used as dental composite. However the aim of this work is to use hyperbranched polymer in an attempt to produce dental composite. The reason is because the dendritic molecules have shown low viscosity at higher molecular weight compared to the linear counterparts. Therefore, this work attempts to substitute the linear polymer with as much of hyperbranched polymer in the dental composite that would pass the required ISO 4049:1998(E) "Dentistry - Resin-based filling material". Several formulations of dental composites were used, i.e. combinations of linear-linear and linear-hyperbranched polymers for comparison. Following this, physical and mechanical characterisation were conducted based on the ISO standards such as water sorption and water solubility. Other characterisation such as polymerisation shrinkage and Vickers hardness were also evaluated. It was found that different types of resins give different physical and mechanical properties. The maximum achievable hyperbranched polymer, which passes the required ISO standard, that can be incorporated in the linear polymer to form dental composite is 43% wt.
    Matched MeSH terms: Biomechanical Phenomena
  17. Mohamed SH, Arifin A, Mohd Ishak ZA, Nizam A, Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:25-6.
    PMID: 15468801
    The aim of this study was to evaluate the effect of powder-to-liquid ratio on the glass transition temperature (Tg) and the tensile properties of denture base material prepared from poly (methyl methacrylate) (PMMA) and hydroxyapatite (HA) previously treated with 3-trimethoxysilylpropyl methacrylate (gamma-MPS). Specimens for mechanical testing were prepared by adding composites powder (PMMA, BPO and HA) to the monomer (MMA and EGDMA) followed by hand mixing as in dental laboratory description usage. The glass transition temperature was studied by using differential scanning calorimetry (DSC). It was observed that the tensile properties and the Tg were affected by the powder-to-liquid ratio. The mechanical characterization of the materials were performed by using single edge notch-tension (SEN-T) specimens; the fracture toughness was slightly higher in formulation which contained HA filler compared to commercial denture base material.
    Matched MeSH terms: Biomechanical Phenomena
  18. Konduk BA, Ucisik AH
    Med J Malaysia, 2004 May;59 Suppl B:53-4.
    PMID: 15468815
    The effect of hemodialysis on the mechanical behavior of a cellulosic Hemophane ME-IOH and one Polysulfone type hollow fibers was investigated. Mechanical tests showed that the deformation of polysulfone type of hollow fibers is entirely different than that of the other dialyser for the samples used and unused in hemodialysis. All the samples exposed to the dialysis showed decreased in ductility. Fracture surface studies proved that there was some alignment on the fracture surface. XRD and DSC experiments revealed structural changes had occurred.
    Matched MeSH terms: Biomechanical Phenomena
  19. Samsudin OC, Aminuddin BS, Munirah S, Chua KH, Fuzina NH, Isa MR, et al.
    Med J Malaysia, 2004 May;59 Suppl B:15-6.
    PMID: 15468796
    Treatment of articular cartilage lesions remains a clinical challenge. The uses of prosthetic joint replace allograft and/or autograft transplant carry a risk of complications due to infection, loosening of its component, immunological rejection and morbidity at the donor site. There has been an increasing interest in the management of cartilage damages, owing to the introduction of new therapeutic options. Tissue engineering as a method for tissue restoration begins to provide a potential alternative therapy for autologous grafts transplantations. We aimed to evaluate how well a tissue engineered neocartilage implant, consist of human articular chondrocytes cultured with the presence of autologous serum and mixed in a fresh fibrin derived from patient, would perform in subcutaneous implantation in athymic mice.
    Matched MeSH terms: Biomechanical Phenomena
  20. Goh JC, Shao XX, Hutmacher D, Lee EH
    Med J Malaysia, 2004 May;59 Suppl B:17-8.
    PMID: 15468797
    Matched MeSH terms: Biomechanical Phenomena
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links