Displaying publications 1 - 20 of 151 in total

Abstract:
Sort:
  1. Jones CR, Ovenell SM
    J. Chromatogr., 1979 Jun 11;163(2):179-85.
    PMID: 541369
    A high-performance liquid chromatographic method was developed to enable dapsone, monoacetyl dapsone and pyrimethamine to be measured simultaneously in plasma samples from volunteers in England and Malaysia who had been dosed with Maloprim. Mean half-lives of 25 and 80 h were calculated for dapsone and pyrimethamine, respectively, but there was wide individual variation. All subjects were found to be classifiable as "slow acetylators".
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  2. Ramanathan S, Nair NK, Mansor SM, Navaratnam V
    J Chromatogr B Biomed Appl, 1994 May 13;655(2):269-73.
    PMID: 8081473
    A rapid and selective high-performance liquid chromatographic (HPLC) method for the simultaneous determination of the antifilarial drug UMF-078 (I) and its metabolites UMF-060 (II) and flubendazole (III) is described. After a simple extraction from whole blood, the compounds were determined by HPLC using a C18 Inertsil ODS-2 reversed-phase column with methanol-0.05M ammonium acetate (pH 4.0) as the mobile phase and ultraviolet detection at 291 nm. The average recoveries of I, II and III over the concentration range 20-500 ng ml-1 were 69.9 +/- 4.7, 85.6 +/- 4.4 and 85.1 +/- 6.0%, respectively. The minimum detectable concentrations in whole blood for I, II and III were 10, 7 and 7 ng ml-1, respectively. This method was found to be suitable for pharmacokinetic studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  3. Harrison LJ, Sia GL, Sim KY, Tan HT, Connolly JD, Lavaud C, et al.
    Phytochemistry, 1995 Apr;38(6):1497-500.
    PMID: 7786481
    A novel derivative of sucrose, beta-(3,6-di-O-feruloyl)-fructofuranosyl-alpha-(2,3,4,6-tetra-O-ac etyl)- glucopyranoside, was isolated from the wood of Bhesa paniculata. Its structure was determined by a combination of 2D 1H-1H and 1H-13C correlation NMR spectroscopy. The known compounds, glycerol 1-9',12'-octadecadienoate, beta-sitosterol, (+/-)-pinoresinol, methyl 3,4-dihydroxybenzoate, 4-hydroxy-3-methoxybenzoic acid, anofinic acid and 2-(1'-methylethenyl)-benzofuran-5-carboxylic acid were also isolated.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  4. Navaratnam V, Mansor SM, Chin LK, Mordi MN, Asokan M, Nair NK
    J Chromatogr B Biomed Appl, 1995 Jul 21;669(2):289-94.
    PMID: 7581905
    A selective reproducible high-performance liquid chromatographic assay for the simultaneous quantitative determination of the antimalarial compound artemether (ARM), dihydroartemisinin (DQHS) and artemisinin (QHS), as internal standard, is described. After extraction from plasma, ARM and DQHS were analysed using a Lichrocart/Lichrosphere 100 CN stainless-steel column and a mobile phase of acetonitrile-0.05 M acetic acid (15:85, v/v) adjusted to pH 5.0, and electrochemical detection in the reductive mode. The mean recovery of ARM and DQHS over a concentration range of 30-120 ng/ml was 81.6% and 93.4%, respectively. The within-day coefficients of variation were 0.89-7.01% for ARM and 3.45-8.11% for DQHS. The day-to-day coefficients of variation were 2.06-8.43% and 3.22-6.33%, respectively. The minimum detectable concentration for ARM and DQHS in plasma was 2.5 and 1.25 ng/ml for both compounds. The method was found to be suitable for use in clinical pharmacological studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  5. Zakiah I, Ashikin YN, Aisiah SM, Ismail HI
    PMID: 8629092
    The Malaysian level of health care has greatly improved so that many of the infectious diseases are now under control. However, perinatal death or death due to unknown childhood diseases remains high (10.3%) being second on the list of causes of death amongst Malaysians. Could inborn metabolic diseases be the main cause of death among these children? Recently, with our success in the development of confirmatory techniques for amino acid disorders using high performance liquid chromatography (HPLC), we have examined 404 samples received from all over the country in 1993. Each specimen with abnormal findings from screening tests by one-dimensional thin layer chromatography was confirmed using HPLC. 41% had generalized aminoacidurias and 4.2% had maple syrup urine disease (MSUD). Patients were aged between 11 days to 6 years. Most of them were Malay males and presented with a history suggestive of MSUD. With this preliminary finding, further studies will be carried out in order to have an investigation and management protocol for the diseases and more importantly to formulate a strategy of screening for the country.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  6. Yahya NA, Ismail Z, Embong KH, Mohamad SA
    PMID: 8629091
    High performance liquid chromatography (HPLC) with phenylisothiocyanate (PITC) is recently used for confirming the diagnosis of inborn errors of metabolism (IEM) especially amino acid disorders in Malaysian children. The method of HPLC used is a precolumn derivatization of amino acids with phenylisothiocyanate and is separated by reversed phase chromatography using 3.9 x 300 mm free amino acid columns and is detected by a UV/Vis detector. The samples are obtained from cases suspected of inborn errors of metabolism, especially of amino acid disorders, which are detected clinically by pediatricians. Initially, samples from patients suspected of inborn errors of metabolism, either urine or serum, are run on one-dimensional thin layer chromatography and supplementary chemical tests to detect the abnormal bands and associated abnormalities respectively. Positive samples are further run on HPLC to determine the specific amino acids abnormality. An examples of a case of maple syrup urine disease is discussed, based on the thin layer chromatography findings and HPLC findings.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  7. Mansor SM, Navaratnam V, Yahaya N, Nair NK, Wernsdorfer WH, Degen PH
    J Chromatogr B Biomed Appl, 1996 Jul 12;682(2):321-5.
    PMID: 8844426
    A rapid and selective high-performance liquid chromatographic assay for determination of a new antimalarial drug (benflumetol, BFL) is described. After extraction with hexane-diethyl ether (70:30, v/v) from plasma, BFL was analysed using a C18 Partisil 10 ODS-3 reversed-phase stainless steel column and a mobile phase of acetonitrile-0.1 M ammonium acetate (90:10, v/v) adjusted to pH 4.9 with ultraviolet detection at 335 nm. The mean recovery of BFL over a concentration range of 50-400 ng/ml was 96.8 +/- 5.2%. The within-day and day-to-day coefficients of variation were 1.8-4.0 and 1.8-4.2%, respectively. The minimum detectable concentration in plasma for BFL was 5 ng/ml with a C.V. of less than 10%. This method was found to be suitable for clinical pharmacokinetic studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  8. Chan KL, Yuen KH, Jinadasa S, Peh KK, Toh WT
    Planta Med, 1997 Feb;63(1):66-9.
    PMID: 9063097
    A high-performance liquid chromatography assay equipped with a glassy carbon electrode for electrochemical detection (HPLC-ECD) was developed at reductive mode for the analysis of artemisinin, the antimalarial drug from Artemisia annua (Asteraceae) in human plasma. This method was selective, sensitive, and produced satisfactory recovery, precision, and accuracy. Analysis of plasma samples from 8 male volunteers given 10 mg kg-1 of artemisinin orally as an aqueous suspension showed a mean peak plasma concentration (Cmax) of 580.89 ng ml-1 +/- 88.64 SD at 2.5 h +/- 0.5 SD after dosing, and the mean area under the plasma concentration-time curve (AUC0-infinity) was 2227.57 ng h ml-1 +/- 677.22 SD. In addition, the elimination rate constant (Ke), elimination half-life (t1/2), and apparent volume of distribution (Vd) were calculated to be 0.2971 h-1 +/- 0.0644 SD, 2.42 h +/- 0.46 SD, and 16.26 l kg-1 +/- 3.44 SD, respectively.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  9. Kah Hay Yuen, Kok Khiang Peh
    J Chromatogr B Biomed Sci Appl, 1998 Jun 12;710(1-2):243-6.
    PMID: 9686895
    A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of metformin in human plasma. The method entailed direct injection of the plasma sample after deproteination using perchloric acid. The mobile phase comprised 0.01 M potassium dihydrogen orthophosphate (pH 3.5) and acetonitrile (60:40, v/v). Analyses were run at a flow-rate of 1.0 ml/min with the detector operating at a detection wavelength of 234 nm. The method is specific and sensitive, with a quantification limit of approximately 60 ng/ml and a detection limit of 15 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery value was about 97%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The calibration curve was linear over a concentration range of 62.5-4000 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  10. Yuen KH, Peh KK
    J Chromatogr B Biomed Sci Appl, 1998 Sep 18;715(2):436-40.
    PMID: 9792531
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of ketoconazole in human plasma. The method entailed direct injection of the plasma sample after deproteinization using acetonitrile. The mobile phase comprised 0.05 M disodium hydrogen orthophosphate and acetonitrile (50:50, v/v) adjusted to pH 6. Analysis was run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 260 nm and an emission wavelength of 375 nm. The method is specific and sensitive with a quantification limit of approximately 60 ng/ml and a detection limit of 40 ng/ml at a signal-to-noise ratio of 3:1. Mean absolute recovery value was about 105%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 14%. The calibration curve was linear over a concentration range of 62.5-8000 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  11. Jia Woei Wong, Kah Hay Yuen, Kok Khiang Peh
    J Chromatogr B Biomed Sci Appl, 1998 Sep 25;716(1-2):387-91.
    PMID: 9824257
    A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of pentoxifylline in human plasma. Prior to analysis, pentoxifylline and the internal standard (chloramphenicol) were extracted from plasma sample using dichloromethane. The mobile phase comprised 0.02 M phosphoric acid adjusted to pH 4, methanol and tetrahydrofuran (55:45:1, v/v). Analysis was run at a flow-rate of 1.4 ml/min with the detector operated at a wavelength of 273 nm. The method was specific and sensitive with a detection limit of approximately 3.0 ng/ml at a signal to noise ratio of 3:1, while the limit of quantification was 12.5 ng/ml. Mean recovery value of the extraction procedure was about 99.9%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 10.0%. The calibration curve was linear over a concentration range of 12.5-400.0 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  12. Wong CF, Peh KK, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1998 Oct 23;718(1):205-10.
    PMID: 9832378
    A simple high-performance liquid chromatographic method was developed for the determination of ranitidine in human plasma. Prior to analysis, ranitidine and the internal standard (metoprolol) were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M potassium dihydrogenphosphate-acetonitrile (88:12, v/v) adjusted to pH 6.5. Analysis was run at a flow-rate of 1.3 ml/min and at a detection wavelength of 229 nm. The method is sensitive with a detection limit of 1 ng/ml at a signal-to-noise ratio of 3:1, while the quantification limit was set at 15 ng/ml. The calibration curve was linear over a concentration range of 15-2000 ng/ml. Mean recovery value of the extraction procedure was about 90%, while the within-day and between-day coefficients of variation and percent error values of the assay method were all less than 15%.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  13. Ali N, Hashim NH, Yoshizawa T
    Food Addit Contam, 1999 Jul;16(7):273-80.
    PMID: 10656052
    For application to the analysis of aflatoxins (AF) in commercial peanut and corn products, the ISOLUTE multimode column (IMC, solid phase multifunctional column) method was validated by comparing with the modified Florisil column (MFC) method. Twenty-two peanut and eight corn products from Malaysia and the Philippines were analysed for AFB1, AFB2, AFG1 and AFG2 firstly by the MFC method and then by the IMC method. For peanut products, 14 out of 22 samples were positive by the two methods in the range of 1-378 micrograms/kg of AF, and correlation coefficients (r) for AFB1 and AFB2 were 0.987 and 0.997, respectively. For corn and corn products, all the samples were positive in the range of 1-130 micrograms/kg, and r values were 0.992 and 0.805 for AFB1 and AFB2 respectively. Thus, the results were significantly (p < 0.01) in close agreement, particularly for lower range of 1-50 micrograms/kg of AF concentrations in all the samples. For the occurrence of AF, 11 (65%) of peanut products from Malaysia were contaminated with AF at a mean level of 50 micrograms/kg (maximum 180 micrograms/kg) and two (40% products from the Philippines were contaminated with as high as 375 micrograms/kg and 177 micrograms/kg of AF, respectively. All the corn products from the Philippines were contaminated with AF at a mean level of 44 micrograms/kg (maximum 130 micrograms/kg). Contamination of commercial foods with high levels of AF is a very important issue to both the countries since these foods are very popular among children.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  14. Julianto T, Yuen KH, Noor AM
    J Chromatogr B Biomed Sci Appl, 1999 Sep 10;732(1):227-31.
    PMID: 10517240
    A simple high-performance liquid chromatographic method using UV detection was developed for the determination of alpha-tocopherol in human plasma. The method entailed direct injection of the plasma sample after deproteinization using acetonitrile-tetrahydrofuran (3:2). The mobile phase comprised methanol-tetrahydrofuran (94:6) and analysis was run at a flow-rate of 1.5 ml/min with the detector operating at 292 nm. A Crestpak C18S (5 microm, 250 mm x 4.6 mm ID) was used for the chromatographic separation. The method had a mean recovery of 93%, while the within-day and between-day coefficients of variation and percentage errors were all less than 7%. The speed, specificity, sensitivity and reproducibility of this method make it particularly suitable for routine determination of alpha-tocopherol in human plasma. Moreover, only a small sample plasma volume (100 microl) is required for the analysis.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  15. Yap SP, Julianto T, Wong JW, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1999 Dec 10;735(2):279-83.
    PMID: 10670741
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of vitamin E especially delta-, gamma- and alpha-tocotrienols in human plasma. The method entailed direct injection of plasma sample after deproteinization using a 3:2 mixture of acetonitrile-tetrahydrofuran. The mobile phase comprised 0.5% (v/v) of distilled water in methanol. Analyses were run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 296 nm and emission wavelength of 330 nm. This method is specific and sensitive, with a quantification limit of approximately 40, 34 and 16 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. The mean absolute recovery values were about 98% while the within-day and between-day relative standard deviation and percent error values of the assay method were all less than 12.0% for alpha-, gamma- and delta-tocotrienol. The calibration curve was linear over a concentration range of 40-2500, 30-4000 and 16-1000 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. Application of the method in a bioavailability study for determination of the above compounds was also demonstrated.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  16. Xu ZQ, Norris KJ, Weinberg DS, Kardatzke J, Wertz P, Frank P, et al.
    J Chromatogr B Biomed Sci Appl, 2000 Jun 09;742(2):267-75.
    PMID: 10901131
    A HPLC method was validated for quantification of (+)-calanolide A (1), a novel anti-HIV agent, in rat, dog and human plasma. The synthetic intermediate (+/-)-12-oxocalanolide A (2) was found to be a suitable internal standard. Compounds were extracted from plasma using a solid-phase C(18) cartridge and quantified over the assay range of 12.5 to 800 ng/ml. The method was utilized to determine (+)-calanolide A pharmacokinetics in rats, dogs and humans. This is the first report of a validated HPLC assay for determination of (+)-calanolide A concentrations in rat and dog plasma as well as human plasma obtained from clinical trials. There was no evidence of in vivo epimerization of (+)-calanolide A to its inactive epimer (+)-calanolide B (3).
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  17. Cheah PY, Yuen KH, Liong ML
    J Chromatogr B Biomed Sci Appl, 2000 Aug 18;745(2):439-43.
    PMID: 11043762
    A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25-100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25-100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  18. Yuen KH, Choy WP, Tan HY, Wong JW, Yap SP
    J Pharm Biomed Anal, 2001 Feb;24(4):715-9.
    PMID: 11272330
    A simple high-performance liquid chromatographic method was developed for the determination of omeprazole in human plasma. Omeprazole and the internal standard, chloramphenicol, were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M Na2HPO4-ACN (65:35, v/v) adjusted to pH 6.5. Analysis was run at a flow rate of 1.0 ml/min at a detection wavelength of 302 nm. The method was specific and sensitive with a detection limit of 2.5 ng/ml at a signal-to-noise ratio of 4:1. The limit of quantification was set at 5 ng/ml. The calibration curve was linear over a concentration range of 5-1280 ng/ml. Mean recovery value of the extraction procedure was about 96%, while the within and between day coefficient of variation and percent error values of the assay method were all less than 14%.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  19. Kósa A, Cserháti T, Forgács E, Morais H, Mota T, Ramos AC
    J Chromatogr A, 2001 Apr 27;915(1-2):149-54.
    PMID: 11358243
    The colour pigments of five chili powders of different origins were separated and quantified by reversed-phase high-performance liquid chromatography (RP-HPLC). The similarities and dissimilarities of pigment composition of chili powders were elucidated by principal component analysis (PCA). RP-HPLC separated 50-100 pigment fractions depending on the detection wavelength and on the origin of chili powder. It was found that the pigment composition of chili powders from Malaysia and China and from India and Pakistan show marked similarities while the composition of colour pigments of chili powder from Thailand was different. It was further established that the chromatograms are similar in the first 5-35 min of development, they are highly different between 35 and 75 min and moderately different at the end of the chromatograms. It was concluded that RP-HPLC followed by PCA can be successfully used for the identification of chili powders according to the composition of their colour pigments.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  20. Ching LS, Mohamed S
    J Agric Food Chem, 2001 Jun;49(6):3101-5.
    PMID: 11410015
    Vitamin E was determined by the high-performance liquid chromatography (HPLC) method. All the plants tested showed differences in their alpha-tocopherol content and the differences were significant (p < 0.05). The highest alpha-tocopherol content was in Sauropus androgynus leaves (426.8 mg/kg edible portion), followed by Citrus hystrix leaves (398.3 mg/kg), Calamus scipronum (193.8 mg/kg), starfruit leaves Averrhoa belimbi (168.3 mg/kg), red pepper Capsicum annum (155.4 mg/kg), local celery Apium graveolens (136.4 mg/kg), sweet potato shoots Ipomoea batatas (130.1 mg/kg), Pandanus odorus (131.5 mg/kg), Oenanthe javanica (146.8 mg/kg), black tea Camelia chinensis (183.3 mg/kg),papaya Carica papaya shoots (111.3 mg/kg), wolfberry leaves Lycium chinense (94.4 mg/kg), bird chili Capsicum frutescens leaves (95.4 mg/kg), drumstick Moringa oleifera leaves (90.0 mg/kg), green chili Capsicum annum (87 mg/kg), Allium fistulosum leaves (74.6 mg/kg), and bell pepper Capsicum annum (71.0 mg/kg). alpha-Tocopherol was not detected in Brassica oleracea, Phaeomeria speciosa, Pachyrrhizus speciosa, Pleurotus sajor-caju, and Solanum melongena.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links