METHODS: The Singapore Prostate Cancer Study is a hospital-based case-control study of 240 prostate cancer incident cases and 268 controls conducted in Singapore between April 2007 and May 2009. Detailed information on outdoor activities in the sun, skin colour, sun sensitivity and other possible risk factors were collected in personal interviews. Cases were further classified by Gleason scores and TNM staging. Odds ratios (OR) and 95% confidence intervals (CI) were calculated using unconditional logistic regression analysis, adjusted for age, ethnicity, education, family history of any cancers, BMI and skin colour.
RESULTS: We found that prostate cancer risk was increased in subjects with black/dark-brown eyes (OR 5.88, 95%CI 3.17-10.9), darker skin colour e.g. tan/dark brown/black (OR 7.62, 95%CI 3.41-17.0), frequent sunburn in lifetime (OR 4.30, 95%CI 1.7-11.2) and increased general sun exposure in adulthood per week (OR 2.03, 95%CI 1.09-3.81). The increased risk was consistent for high grade tumours and advanced stage prostate cancers.
CONCLUSION: The findings from this study suggest that excessive sun exposure is a risk factor for prostate cancer in Asians.
BACKGROUND: The Occlutech® PDA occluder is novel, self-shaping Nitinol wire device with PET (polyethylene terephthalate) patches integrated into the shank of the device to assure a better obturation of the ductus. The Occlutech® PDA occluder has undergone two design modifications.
METHODS: A prospective, non-randomized pilot study was started in November 2011. Thirty-three patients were included until April 2013. Patients weighing <6 kg or those with associated cardiac anomalies that required surgery were excluded. All patients were followed up by transthoracic echocardiography at 24 hr, 30 days, 90 days, 180 days, and 360 days after implantation. Residual shunt, left pulmonary artery (LPA) and descending aortic velocities were among the parameters assessed. All occluders were delivered via 6-8 F long sheaths and PDA closures were performed following standard techniques.
RESULTS: Thirty three patients (20 female/13 male), with a median age of 2 years (6 month to 38 years), and median weight of 9.3 kg (6-69.2 kg) were included. The narrowest median PDA diameter was 3mm (1.8-5.8 mm). All the 33 patients were closed successfully using Occlutech ductal occluder, 16 patients (48.4%) had immediate and complete closure on angiography. Within 24 hr, color Doppler revealed complete closure in 27patients (81.8%), 32patients (97%) at 30 days, and in 100% of patients at 90 days. All patients with a large PDA had immediate residual shunt which was closed at the 90-day follow-up. There was no device embolization, hemolysis, or obstruction to the LPA or descending aorta.
CONCLUSION: The new Occlutech® PDA is safe and effective. In patients with a large PDA complete closure tended to take longer time.