Displaying publications 1 - 20 of 604 in total

Abstract:
Sort:
  1. Ab Aziz NA, Mubin M, Mohamad MS, Ab Aziz K
    ScientificWorldJournal, 2014;2014:123019.
    PMID: 25121109 DOI: 10.1155/2014/123019
    In the original particle swarm optimisation (PSO) algorithm, the particles' velocities and positions are updated after the whole swarm performance is evaluated. This algorithm is also known as synchronous PSO (S-PSO). The strength of this update method is in the exploitation of the information. Asynchronous update PSO (A-PSO) has been proposed as an alternative to S-PSO. A particle in A-PSO updates its velocity and position as soon as its own performance has been evaluated. Hence, particles are updated using partial information, leading to stronger exploration. In this paper, we attempt to improve PSO by merging both update methods to utilise the strengths of both methods. The proposed synchronous-asynchronous PSO (SA-PSO) algorithm divides the particles into smaller groups. The best member of a group and the swarm's best are chosen to lead the search. Members within a group are updated synchronously, while the groups themselves are asynchronously updated. Five well-known unimodal functions, four multimodal functions, and a real world optimisation problem are used to study the performance of SA-PSO, which is compared with the performances of S-PSO and A-PSO. The results are statistically analysed and show that the proposed SA-PSO has performed consistently well.
    Matched MeSH terms: Computer Simulation
  2. Low WS, Kadri NA, Abas WA
    ScientificWorldJournal, 2014;2014:961301.
    PMID: 25136701 DOI: 10.1155/2014/961301
    We propose a strategy for optimizing distribution of flow in a typical benchtop microfluidic chamber for dielectrophoretic application. It is aimed at encouraging uniform flow velocity along the whole analysis chamber in order to ensure DEP force is evenly applied to biological particle. Via the study, we have come up with a constructive strategy in improving the design of microfluidic channel which will greatly facilitate the use of DEP system in laboratory and primarily focus on the relationship between architecture and cell distribution, by resorting to the tubular structure of blood vessels. The design was validated by hydrodynamic flow simulation using COMSOL Multiphysics v4.2a software. Simulations show that the presence of 2-level bifurcation has developed portioning of volumetric flow which produced uniform flow across the channel. However, further bifurcation will reduce the volumetric flow rate, thus causing undesirable deposition of cell suspension around the chamber. Finally, an improvement of microfluidic design with rounded corner is proposed to encourage a uniform cell adhesion within the channel.
    Matched MeSH terms: Computer Simulation
  3. Oshkour AA, Abu Osman NA, Yau YH, Tarlochan F, Abas WA
    Proc Inst Mech Eng H, 2013 Jan;227(1):3-17.
    PMID: 23516951
    This study aimed to develop a three-dimensional finite element model of a functionally graded femoral prosthesis. The model consisted of a femoral prosthesis created from functionally graded materials (FGMs), cement, and femur. The hip prosthesis was composed of FGMs made of titanium alloy, chrome-cobalt, and hydroxyapatite at volume fraction gradient exponents of 0, 1, and 5, respectively. The stress was measured on the femoral prosthesis, cement, and femur. Stress on the neck of the femoral prosthesis was not sensitive to the properties of the constituent material. However, stress on the stem and cement decreased proportionally as the volume fraction gradient exponent of the FGM increased. Meanwhile, stress became uniform on the cement mantle layer. In addition, stress on the femur in the proximal part increased and a high surface area of the femoral part was involved in absorbing the stress. As such, the stress-shielding area decreased. The results obtained in this study are significant in the design and longevity of new prosthetic devices because FGMs offer the potential to achieve stress distribution that more closely resembles that of the natural bone in the femur.
    Matched MeSH terms: Computer Simulation
  4. Al-Mishmish H, Akhayyat A, Rahim HA, Hammood DA, Ahmad RB, Abbasi QH
    Sensors (Basel), 2018 Oct 28;18(11).
    PMID: 30373314 DOI: 10.3390/s18113661
    Wireless Body Area Networks (WBANs) are single-hop network systems, where sensors gather the body's vital signs and send them directly to master nodes (MNs). The sensors are distributed in or on the body. Therefore, body posture, clothing, muscle movement, body temperature, and climatic conditions generally influence the quality of the wireless link between sensors and the destination. Hence, in some cases, single hop transmission ('direct transmission') is not sufficient to deliver the signals to the destination. Therefore, we propose an emergency-based cooperative communication protocol for WBAN, named Critical Data-based Incremental Cooperative Communication (CD-ICC), based on the IEEE 802.15.6 CSMA standard but assuming a lognormal shadowing channel model. In this paper, a complete study of a system model is inspected in the terms of the channel path loss, the successful transmission probability, and the outage probability. Then a mathematical model is derived for the proposed protocol, end-to-end delay, duty cycle, and average power consumption. A new back-off time is proposed within CD-ICC, which ensures the best relays cooperate in a distributed manner. The design objective of the CD-ICC is to reduce the end-to-end delay, the duty cycle, and the average power transmission. The simulation and numerical results presented here show that, under general conditions, CD-ICC can enhance network performance compared to direct transmission mode (DTM) IEEE 802.15.6 CSMA and benchmarking. To this end, we have shown that the power saving when using CD-ICC is 37.5% with respect to DTM IEEE 802.15.6 CSMA and 10% with respect to MI-ICC.
    Matched MeSH terms: Computer Simulation
  5. Teo J, Abbass HA
    Evol Comput, 2004;12(3):355-94.
    PMID: 15355605
    In this paper, we investigate the use of a self-adaptive Pareto evolutionary multi-objective optimization (EMO) approach for evolving the controllers of virtual embodied organisms. The objective of this paper is to demonstrate the trade-off between quality of solutions and computational cost. We show empirically that evolving controllers using the proposed algorithm incurs significantly less computational cost when compared to a self-adaptive weighted sum EMO algorithm, a self-adaptive single-objective evolutionary algorithm (EA) and a hand-tuned Pareto EMO algorithm. The main contribution of the self-adaptive Pareto EMO approach is its ability to produce sufficiently good controllers with different locomotion capabilities in a single run, thereby reducing the evolutionary computational cost and allowing the designer to explore the space of good solutions simultaneously. Our results also show that self-adaptation was found to be highly beneficial in reducing redundancy when compared against the other algorithms. Moreover, it was also shown that genetic diversity was being maintained naturally by virtue of the system's inherent multi-objectivity.
    Matched MeSH terms: Computer Simulation
  6. Baharuddin MY, Salleh ShH, Zulkifly AH, Lee MH, Noor AM, A Harris AR, et al.
    PMID: 24484753 DOI: 10.1186/1471-2474-15-30
    Minimal available information concerning hip morphology is the motivation for several researchers to study the difference between Asian and Western populations. Current use of a universal hip stem of variable size is not the best option for all femur types. This present study proposed a new design process of the cementless femoral stem using a three dimensional model which provided more information and accurate analysis compared to conventional methods.
    Matched MeSH terms: Computer Simulation
  7. Wan Hassan WN, Othman SA, Chan CS, Ahmad R, Ali SN, Abd Rohim A
    Am J Orthod Dentofacial Orthop, 2016 Nov;150(5):886-895.
    PMID: 27871715 DOI: 10.1016/j.ajodo.2016.04.021
    INTRODUCTION: In this study we aimed to compare measurements on plaster models using a digital caliper, and on 3-dimensional (3D) digital models, produced using a structured-light scanner, using 3D software.

    METHODS: Fifty digital models were scanned from the same plaster models. Arch and tooth size measurements were made by 2 operators, twice. Calibration was done on 10 sets of models and checked using the Pearson correlation coefficient. Data were analyzed by error variances, repeatability coefficient, repeated-measures analysis of variance, and Bland-Altman plots.

    RESULTS: Error variances ranged between 0.001 and 0.044 mm for the digital caliper method, and between 0.002 and 0.054 mm for the 3D software method. Repeated-measures analysis of variance showed small but statistically significant differences (P <0.05) between the repeated measurements in the arch and buccolingual planes (0.011 and 0.008 mm, respectively). There were no statistically significant differences between methods and between operators. Bland-Altman plots showed that the mean biases were close to zero, and the 95% limits of agreement were within ±0.50 mm. Repeatability coefficients for all measurements were similar.

    CONCLUSIONS: Measurements made on models scanned by the 3D structured-light scanner were in good agreement with those made on conventional plaster models and were, therefore, clinically acceptable.

    Matched MeSH terms: Computer Simulation*
  8. Lee CS, Abd Shukor SR
    Environ Sci Pollut Res Int, 2023 Dec;30(60):124790-124805.
    PMID: 36961637 DOI: 10.1007/s11356-023-26358-x
    The controllable intensified process has received immense attention from researchers in order to deliver the benefit of process intensification to be operated in a desired way to provide a more sustainable process toward reduction of environmental impact and improvement of intrinsic safety and process efficiency. Despite numerous studies on gain and phase margin approach on conventional process systems, it is yet to be tested on intensified systems as evidenced by the lack of available literature, to improve the controller performance and robustness. Thus, this paper proposed the exact gain and phase margin (EGPM) through analytical method to develop suitable controller design for intensified system using Proportional-Integral-Derivative (PID) controller formulation, and it was compared to conventional Direct Synthesis methods (DS), Internal Model Control (IMC), and Industrial IMC method in terms of the performance and stability analysis. Simulation results showed that EGPM method provides good setpoint tracking and disturbance rejection as compared to DS, IMC, and Industrial IMC while retaining overall performance stability as time delay increases. The Bode Stability Criterion was used to determine the stability of the open-loop transfer function of each method and the result demonstrated decrease in stability as time delay increases for controllers designed using DS, IMC, and Industrial IMC, and hence control performance degrades. However, the proposed EGPM controller maintains the overall robustness and control performance throughout the increase of time delay and outperform other controller design methods at higher time delay with [Formula: see text] uncertainty test. Additionally, the proposed EGPM controller design method provides overall superior control performance with lower overshoot and shorter rise time compared to other controllers when process time constant is smaller in magnitude ([Formula: see text]) than the instrumentation element, which is one of the major concerns during the design of intensified controllers, resulting overall system with a higher order. The desired selection of gain margin and phase margin were suggested at 2.5 to 4 and 60 °-70 [Formula: see text], respectively, for a wide range of control conditions for intensified processes where higher instrumentation dynamic would be possible to achieve robust control as well. The proposed EGPM method controller is thought to be a more reliable design strategy for maintaining the overall robustness and performance of higher order and complex systems that are highly affected by time delay and high dynamic response of intensified processes.
    Matched MeSH terms: Computer Simulation
  9. Johari NH, Osman K, Helmi NH, Abdul Kadir MA
    PMID: 23521065 DOI: 10.1080/10255842.2013.776548
    Efforts to model the human upper respiratory system have undergone many phases. Geometrical proximity to the realistic shape has been the subject of many research projects. In this study, three different geometries of the trachea and main bronchus were modelled, which were reconstructed from computed tomography (CT) scan images. The geometrical variations were named realistic, simplified and oversimplified. Realistic refers to the lifelike image taken from digital imaging and communications in medicine format CT scan images, simplified refers to the reconstructed image based on natural images without realistic details pertaining to the rough surfaces, and oversimplified describes the straight wall geometry of the airway. The characteristics of steady state flows with different flow rates were investigated, simulating three varied physical activities and passing through each model. The results agree with previous studies where simplified models are sufficient for providing comparable results for airflow in human airways. This work further suggests that, under most exercise conditions, the idealised oversimplified model is not favourable for simulating either airflow regimes or airflow with particle depositions. However, in terms of immediate analysis for the prediction of abnormalities of various dimensions of human airways, the oversimplified techniques may be used.
    Matched MeSH terms: Computer Simulation*
  10. Helal MH, Al-Mudaris ZA, Al-Douh MH, Osman H, Wahab HA, Alnajjar BO, et al.
    Int J Oncol, 2012 Aug;41(2):504-10.
    PMID: 22614449 DOI: 10.3892/ijo.2012.1491
    Molecules that target the deoxyribonucleic acid (DNA) minor groove are relatively sequence specific and they can be excellent carrier structures for cytotoxic chemotherapeutic compounds which can help to minimize side effects. Two novel isomeric derivatives of diaminobenzene Schiff base [N,N'-bis (2-hydroxy-3-methoxybenzylidene)-1,2-diaminobenzene (2MJ) and N,N'-bis(2-hydroxy-3-methoxybenzylidene)-1,3-diaminobenzene (2MH)] were analyzed for their DNA minor groove binding (MGB) ability using viscometry, UV and fluorescence spectroscopy, computational modeling and clonogenic assay. The result shows that 2MJ and 2MH are strong DNA MGBs with the latter being more potent. 2MH can form interstrand hydrogen bond linkages at its oxygens with N3 of adenines. Changing the 2-hydroxy-3-methoxybenzylidene binding position to the 1,3 location on the diaminobenzene structure (2MJ) completely removed any viable hydrogen bond formation with the DNA and caused significant decrease in binding strength and minor groove binding potency. Neither compound showed any significant cytotoxicity towards human breast, colon or liver cancer cell lines.
    Matched MeSH terms: Computer Simulation
  11. Baharuddin MY, Salleh ShH, Hamedi M, Zulkifly AH, Lee MH, Mohd Noor A, et al.
    Biomed Res Int, 2014;2014:478248.
    PMID: 24800230 DOI: 10.1155/2014/478248
    Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA) is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM) to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing.
    Matched MeSH terms: Computer Simulation
  12. Jaddi NS, Abdullah S, Abdul Malek M
    PLoS One, 2017;12(1):e0170372.
    PMID: 28125609 DOI: 10.1371/journal.pone.0170372
    Artificial neural networks (ANNs) have been employed to solve a broad variety of tasks. The selection of an ANN model with appropriate weights is important in achieving accurate results. This paper presents an optimization strategy for ANN model selection based on the cuckoo search (CS) algorithm, which is rooted in the obligate brood parasitic actions of some cuckoo species. In order to enhance the convergence ability of basic CS, some modifications are proposed. The fraction Pa of the n nests replaced by new nests is a fixed parameter in basic CS. As the selection of Pa is a challenging issue and has a direct effect on exploration and therefore on convergence ability, in this work the Pa is set to a maximum value at initialization to achieve more exploration in early iterations and it is decreased during the search to achieve more exploitation in later iterations until it reaches the minimum value in the final iteration. In addition, a novel master-leader-slave multi-population strategy is used where the slaves employ the best fitness function among all slaves, which is selected by the leader under a certain condition. This fitness function is used for subsequent Lévy flights. In each iteration a copy of the best solution of each slave is migrated to the master and then the best solution is found by the master. The method is tested on benchmark classification and time series prediction problems and the statistical analysis proves the ability of the method. This method is also applied to a real-world water quality prediction problem with promising results.
    Matched MeSH terms: Computer Simulation
  13. Abedi Karjiban R, Abdul Rahman MB, Basri M, Salleh AB, Jacobs D, Abdul Wahab H
    Protein J, 2009 Jan;28(1):14-23.
    PMID: 19130194 DOI: 10.1007/s10930-008-9159-7
    Molecular Dynamics (MD) simulations have been used to understand how protein structure, dynamics, and flexibility are affected by adaptation to high temperature for several years. We report here the results of the high temperature MD simulations of Bacillus stearothermophilus L1 (L1 lipase). We found that the N-terminal moiety of the enzyme showed a high flexibility and dynamics during high temperature simulations which preceded and followed by clear structural changes in two specific regions; the small domain and the main catalytic domain or core domain of the enzyme. These two domains interact with each other through a Zn(2+)-binding coordination with Asp-61 and Asp-238 from the core domain and His-81 and His-87 from the small domain. Interestingly, the His-81 and His-87 were among the highly fluctuated and mobile residues at high temperatures. The results appear to suggest that tight interactions of Zn(2+)-binding coordination with specified residues became weak at high temperature which suggests the contribution of this region to the thermostability of the enzyme.
    Matched MeSH terms: Computer Simulation
  14. Ibrahim S, Abdul Wahab N
    Water Sci Technol, 2024 Apr;89(7):1701-1724.
    PMID: 38619898 DOI: 10.2166/wst.2024.099
    Hyperparameter tuning is an important process to maximize the performance of any neural network model. This present study proposed the factorial design of experiment for screening and response surface methodology to optimize the hyperparameter of two artificial neural network algorithms. Feed-forward neural network (FFNN) and radial basis function neural network (RBFNN) are applied to predict the permeate flux of palm oil mill effluent. Permeate pump and transmembrane pressure of the submerge membrane bioreactor system are the input variables. Six hyperparameters of the FFNN model including four numerical factors (neuron numbers, learning rate, momentum, and epoch numbers) and two categorical factors (training and activation function) are used in hyperparameter optimization. RBFNN includes two numerical factors such as a number of neurons and spreads. The conventional method (one-variable-at-a-time) is compared in terms of optimization processing time and the accuracy of the model. The result indicates that the optimal hyperparameters obtained by the proposed approach produce good accuracy with a smaller generalization error. The simulation results show an improvement of more than 65% of training performance, with less repetition and processing time. This proposed methodology can be utilized for any type of neural network application to find the optimum levels of different parameters.
    Matched MeSH terms: Computer Simulation
  15. Naderipour A, Nowdeh SA, Babanezhad M, Najmi ES, Kamyab H, Abdul-Malek Z
    Environ Sci Pollut Res Int, 2023 Jun;30(28):71754-71765.
    PMID: 34499303 DOI: 10.1007/s11356-021-16342-8
    In this paper, the technical-economic framework for designing of water pumping system based on photovoltaic clean energy with water tank storage is presented to supply drinking water of customers for remote areas. The objective function is to minimize the net present cost (NPC) (as economic index) including initial investment costs, maintenance, and replacement costs, and reliability constraint is defined as customer's water not supplied probability (CWNSP) as technical index. A meta-heuristic intelligent water drops algorithm (IWDA) is proposed to optimize the solar water pumping system considering NPC and CWNSP with high accuracy and speed of optimization in achieving the global solution. The simulation results show that the proposed method is capable of responding to customer's water demand by optimally sizing components and water storage tank based on IWDA which is inspired based on flowing the water drops in rivers by achieving the lowest cost with optimal reliability. The NPC of the system with CWNSP equal to 3.17 % is obtained 0.24 M$ for 6-m-high water extraction. The results showed that with increasing the water extraction height, the NPC increased, and the reliability also weakened. Moreover, the superiority of the IWDA is confirmed compared with particle swarm optimization (PSO) in designing a water pumping system with the lowest NPC.
    Matched MeSH terms: Computer Simulation
  16. Ismail MA, Deris S, Mohamad MS, Abdullah A
    PLoS One, 2015;10(5):e0126199.
    PMID: 25961295 DOI: 10.1371/journal.pone.0126199
    This paper presents an in silico optimization method of metabolic pathway production. The metabolic pathway can be represented by a mathematical model known as the generalized mass action model, which leads to a complex nonlinear equations system. The optimization process becomes difficult when steady state and the constraints of the components in the metabolic pathway are involved. To deal with this situation, this paper presents an in silico optimization method, namely the Newton Cooperative Genetic Algorithm (NCGA). The NCGA used Newton method in dealing with the metabolic pathway, and then integrated genetic algorithm and cooperative co-evolutionary algorithm. The proposed method was experimentally applied on the benchmark metabolic pathways, and the results showed that the NCGA achieved better results compared to the existing methods.
    Matched MeSH terms: Computer Simulation*
  17. Idrose AM, Adnan WA, Villa GF, Abdullah AH
    Emerg Med J, 2007 Jan;24(1):7-11.
    PMID: 17183034
    There is a dire need to have complementary form of disaster training which is cost effective, relatively easy to conduct, comprehensive, effective and acceptable. This will complement field drills training. A classroom-based training and simulation module was built by combining multiple tools: Powerpoint lectures, simulations utilising the Kuala Lumpur International Airport (KLIA) schematic module into 'floortop' model and video show of previous disaster drill. 76 participants made up of medical responders, categorised as Level 1 (specialists and doctors), Level 2 (paramedics), Level 3 (assistant paramedics) and Level 4 (health attendants and drivers) were trained using this module. A pre-test with validated questions on current airport disaster plans was carried out before the training. At the end of training, participants answered similar questions as post-test. Participants also answered questionnaire for assessment of training's acceptance. There was a mean rise from 47.3 (18.8%) to 84.0 (18.7%) in post-test (p<0.05). For Levels 1, 2, 3 and 4 the scores were 94.8 (6.3)%, 90.1 (11)%, 80.3 (20.1)% and 65 (23.4)% respectively. Nevertheless Level 4 group gained most increase in knowledge rise from baseline pre-test score (51.4%). Feedback from the questionnaire showed that the training module was highly acceptable. A classroom-based training can be enhanced with favourable results. The use of classroom training and simulation effectively improves the knowledge of disaster plan significantly on the back of its low cost, relatively-easy to conduct, fun and holistic nature. All Levels of participants (from specialists to drivers) can be grouped together for training. Classroom training and simulation can overcome the problem of "dead-document" phenomenon or "paper-plan syndrome".
    Matched MeSH terms: Computer Simulation*
  18. Givehchi S, Wong YH, Yeong CH, Abdullah BJJ
    Minim Invasive Ther Allied Technol, 2018 Apr;27(2):81-89.
    PMID: 28612670 DOI: 10.1080/13645706.2017.1330757
    PURPOSE: To investigate the effect of radiofrequency ablation (RFA) electrode trajectory on complete tumor ablation using computational simulation.

    MATERIAL AND METHODS: The RFA of a spherical tumor of 2.0 cm diameter along with 0.5 cm clinical safety margin was simulated using Finite Element Analysis software. A total of 86 points inside one-eighth of the tumor volume along the axial, sagittal and coronal planes were selected as the target sites for electrode-tip placement. The angle of the electrode insertion in both craniocaudal and orbital planes ranged from -90° to +90° with 30° increment. The RFA electrode was simulated to pass through the target site at different angles in combination of both craniocaudal and orbital planes before being advanced to the edge of the tumor.

    RESULTS: Complete tumor ablation was observed whenever the electrode-tip penetrated through the epicenter of the tumor regardless of the angles of electrode insertion in both craniocaudal and orbital planes. Complete tumor ablation can also be achieved by placing the electrode-tip at several optimal sites and angles.

    CONCLUSIONS: Identification of the tumor epicenter on the central slice of the axial images is essential to enhance the success rate of complete tumor ablation during RFA procedures.

    Matched MeSH terms: Computer Simulation*
  19. Umair M, Hidayat NM, Sukri Ahmad A, Nik Ali NH, Mawardi MIM, Abdullah E
    PLoS One, 2024;19(2):e0297376.
    PMID: 38422065 DOI: 10.1371/journal.pone.0297376
    Developing novel EV chargers is crucial for accelerating Electric Vehicle (EV) adoption, mitigating range anxiety, and fostering technological advancements that enhance charging efficiency and grid integration. These advancements address current challenges and contribute to a more sustainable and convenient future of electric mobility. This paper explores the performance dynamics of a solar-integrated charging system. It outlines a simulation study on harnessing solar energy as the primary Direct Current (DC) EV charging source. The approach incorporates an Energy Storage System (ESS) to address solar intermittencies and mitigate photovoltaic (PV) mismatch losses. Executed through MATLAB, the system integrates key components, including solar PV panels, the ESS, a DC charger, and an EV battery. The study finds that a change in solar irradiance from 400 W/m2 to 1000 W/m2 resulted in a substantial 47% increase in the output power of the solar PV system. Simultaneously, the ESS shows a 38% boost in output power under similar conditions, with the assessments conducted at a room temperature of 25°C. The results emphasize that optimal solar panel placement with higher irradiance levels is essential to leverage integrated solar energy EV chargers. The research also illuminates the positive correlation between elevated irradiance levels and the EV battery's State of Charge (SOC). This correlation underscores the efficiency gains achievable through enhanced solar power absorption, facilitating more effective and expedited EV charging.
    Matched MeSH terms: Computer Simulation
  20. Javed E, Faye I, Malik AS, Abdullah JM
    J Neurosci Methods, 2017 11 01;291:150-165.
    PMID: 28842191 DOI: 10.1016/j.jneumeth.2017.08.020
    BACKGROUND: Simultaneous electroencephalography (EEG) and functional magnetic resonance image (fMRI) acquisitions provide better insight into brain dynamics. Some artefacts due to simultaneous acquisition pose a threat to the quality of the data. One such problematic artefact is the ballistocardiogram (BCG) artefact.

    METHODS: We developed a hybrid algorithm that combines features of empirical mode decomposition (EMD) with principal component analysis (PCA) to reduce the BCG artefact. The algorithm does not require extra electrocardiogram (ECG) or electrooculogram (EOG) recordings to extract the BCG artefact.

    RESULTS: The method was tested with both simulated and real EEG data of 11 participants. From the simulated data, the similarity index between the extracted BCG and the simulated BCG showed the effectiveness of the proposed method in BCG removal. On the other hand, real data were recorded with two conditions, i.e. resting state (eyes closed dataset) and task influenced (event-related potentials (ERPs) dataset). Using qualitative (visual inspection) and quantitative (similarity index, improved normalized power spectrum (INPS) ratio, power spectrum, sample entropy (SE)) evaluation parameters, the assessment results showed that the proposed method can efficiently reduce the BCG artefact while preserving the neuronal signals.

    COMPARISON WITH EXISTING METHODS: Compared with conventional methods, namely, average artefact subtraction (AAS), optimal basis set (OBS) and combined independent component analysis and principal component analysis (ICA-PCA), the statistical analyses of the results showed that the proposed method has better performance, and the differences were significant for all quantitative parameters except for the power and sample entropy.

    CONCLUSIONS: The proposed method does not require any reference signal, prior information or assumption to extract the BCG artefact. It will be very useful in circumstances where the reference signal is not available.

    Matched MeSH terms: Computer Simulation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links