Displaying publications 1 - 20 of 66 in total

Abstract:
Sort:
  1. Choong YS, Lee YV, Soong JX, Law CT, Lim YY
    Adv Exp Med Biol, 2017;1053:221-243.
    PMID: 29549642 DOI: 10.1007/978-3-319-72077-7_11
    The use of monoclonal antibody as the next generation protein therapeutics with remarkable success has surged the development of antibody engineering to design molecules for optimizing affinity, better efficacy, greater safety and therapeutic function. Therefore, computational methods have become increasingly important to generate hypotheses, interpret and guide experimental works. In this chapter, we discussed the overall antibody design by computational approches.
    Matched MeSH terms: Computer-Aided Design*
  2. Ibrahim MD, Amran SNA, Yunos YS, Rahman MRA, Mohtar MZ, Wong LK, et al.
    Appl Bionics Biomech, 2018;2018:7854321.
    PMID: 29853998 DOI: 10.1155/2018/7854321
    The skin of a fast swimming shark reveals riblet structures that help reduce the shark's skin friction drag, enhancing its efficiency and speed while moving in the water. Inspired by the structure of the shark skin denticles, our team has carried out a study as an effort in improving the hydrodynamic design of marine vessels through hull design modification which was inspired by this riblet structure of shark skin denticle. Our study covers on macroscaled design modification. This is an attempt to propose an alternative for a better economical and practical modification to obtain a more optimum cruising characteristics for marine vessels. The models used for this study are constructed using computer-aided design (CAD) software, and computational fluid dynamic (CFD) simulations are then carried out to predict the effectiveness of the hydrodynamic effects of the biomimetic shark skins on those models. Interestingly, the numerical calculated results obtained show that the presence of biomimetic shark skin implemented on the vessels give about 3.75% reduction of drag coefficient as well as reducing up to 3.89% in drag force experienced by the vessels. Theoretically, as force drag can be reduced, it can lead to a more efficient vessel with a better cruising speed. This will give better impact to shipping or marine industries around the world. However, it can be suggested that an experimental procedure is best to be conducted to verify the numerical result that has been obtained for further improvement on this research.
    Matched MeSH terms: Computer-Aided Design
  3. Alkhatib SE, Tarlochan F, Mehboob H, Singh R, Kadirgama K, Harun WSBW
    Artif Organs, 2019 Jul;43(7):E152-E164.
    PMID: 30805945 DOI: 10.1111/aor.13444
    The mismatch between stiffness of the femoral dense stem and host bone causes complications to patients, such as aseptic loosening and bone resorption. Three-dimensional finite-element models of homogeneous porous (HGP) and functionally graded porous (FGP) stems incorporating body-centered cubic (BCC) structures are proposed in this article as an alternative to the dense stems. The relationship between the porosity and strut thickness of the BCC structure was developed to construct the finite-element models. Three levels of porosities (20%, 50%, and 80%) were modeled in HGP and FGP stems. The porosity of the stems was decreased distally according to the sigmoid function (n = 0.1, n = 1 and n = 10) with 3 grading exponents. The results showed that FGP stems transferred 120%-170% higher stresses to the femur (Gruen zone 7) as compared to the solid stem. Conversely, the stresses in HGP and FGP stems were 12%-34% lower than the dense stem. The highest micromotions (105-147 µm) were observed for stems of 80% overall porosity, and the lowest (42-46 µm) was for stems of 20% overall porosity. Finally, FGP stems with a grading exponent of n = 10 resulted in an 11%-28% reduction in micromotions.
    Matched MeSH terms: Computer-Aided Design*
  4. Abdullah SJ, Shaikh Mohammed J
    Assist Technol, 2018;30(4):165-175.
    PMID: 28346064 DOI: 10.1080/10400435.2017.1293193
    Independent mobility is vital to individuals of all ages, and wheelchairs have proven to be great personal mobility devices. The tasks of opening and navigating through a door are trivial for healthy people, while the same tasks could be difficult for some wheelchair users. A wide range of intelligent wheelchair controllers and systems, robotic arms, or manipulator attachments integrated with wheelchairs have been developed for various applications, including manipulating door knobs. Unfortunately, the intelligent wheelchairs and robotic attachments are not widely available as commercial products. Therefore, the current manuscript presents the modeling and simulation of a novel but simple technology in the form of a passive wheelchair accessory (straight, arm-like with a single wheel, and arc-shaped with multiple wheels) for pushing doors open from a wheelchair. From the simulations using different wheel shapes and sizes, it was found that the arc-shaped accessory could push open the doors faster and with almost half the required force as compared to the arm-like accessory. Also, smaller spherical wheels were found to be best in terms of reaction forces on the wheels. Prototypes based on the arc-shaped accessory design will be manufactured and evaluated for pushing doors open and dodging or gliding other obstacles.
    Matched MeSH terms: Computer-Aided Design*
  5. Baharuddin MY, Salleh ShH, Zulkifly AH, Lee MH, Noor AM, A Harris AR, et al.
    PMID: 24484753 DOI: 10.1186/1471-2474-15-30
    Minimal available information concerning hip morphology is the motivation for several researchers to study the difference between Asian and Western populations. Current use of a universal hip stem of variable size is not the best option for all femur types. This present study proposed a new design process of the cementless femoral stem using a three dimensional model which provided more information and accurate analysis compared to conventional methods.
    Matched MeSH terms: Computer-Aided Design*
  6. Munusamy SM, Helen-Ng LC, Farook MS
    BMC Oral Health, 2024 Feb 01;24(1):162.
    PMID: 38302972 DOI: 10.1186/s12903-024-03905-7
    BACKGROUND: Computer-aided design/computer-aided manufacturing (CAD/CAM) dental composites were introduced with superior mechanical properties than conventional dental composites. However, little is known on effects of dietary solvents on microhardness or inorganic elemental composition of CAD/CAM composites.

    OBJECTIVES: The objectives of this study were to evaluate the degradation effects of each dietary solvent on the microhardness of the different CAD/CAM dental composites and to observe the degradation effects of dietary solvent on the inorganic elements of the dental composites investigated.

    METHODS: Fifty specimens with dimensions 12 mm x 14 mm x 1.5 mm were prepared for direct composite (Filtek Z350 XT [FZ]), indirect composite (Shofu Ceramage [CM]), and three CAD/CAM composites (Lava Ultimate [LU], Cerasmart [CS], and Vita Enamic [VE]). The specimens were randomly divided into 5 groups (n = 10) and conditioned for 1-week at 37°C in the following: air (control), distilled water, 0.02 N citric acid, 0.02 N lactic acid and 50% ethanol-water solution. Subsequently, the specimens were subjected to microhardness test (KHN) using Knoop hardness indenter. Air (control) and representative postconditioning specimens with the lowest mean KHN value for each material were analyzed using energy dispersive X-ray spectroscopy (EDX). Statistical analysis was done using one-way ANOVA and post hoc Bonferroni test at a significance level of p = 0.05.

    RESULTS: Mean KHN values ranged from 39.7 ± 2.7 kg/mm2 for FZ conditioned in 50% ethanol-water solution to 79.2 ± 3.4 kg/mm2 for VE conditioned in air (control). With exception to LU, significant differences were observed between materials and dietary solvents for other dental composites investigated. EDX showed stable peaks of the inorganic elements between air (control) and representative postconditioning specimens.

    CONCLUSIONS: The microhardness of dental composites was significantly affected by dietary solvents, except for one CAD/CAM composite [LU]. However, no changes were observed in the inorganic elemental composition of dental composites between air (control) and 1-week postconditioning.

    Matched MeSH terms: Computer-Aided Design
  7. Baharuddin MY, Salleh ShH, Hamedi M, Zulkifly AH, Lee MH, Mohd Noor A, et al.
    Biomed Res Int, 2014;2014:478248.
    PMID: 24800230 DOI: 10.1155/2014/478248
    Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA) is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM) to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing.
    Matched MeSH terms: Computer-Aided Design
  8. Ahmed N, Abbasi MS, Haider S, Ahmed N, Habib SR, Altamash S, et al.
    Biomed Res Int, 2021;2021:3194433.
    PMID: 34532499 DOI: 10.1155/2021/3194433
    Objective: Analyzing and comparing the fit and accuracy of removable partial denture (RPDs) frameworks fabricated with CAD/CAM and rapid prototyping methods with conventional techniques.

    Materials and Methods: The present systematic review was carried out according to PRISMA guidelines. The search was carried out on PubMed/MEDLINE, Cochrane collaboration, Science direct, and Scopus scientific engines using selected MeSH keywords. The articles fulfilling the predefined selection criteria based on the fit and accuracy of removable partial denture (RPD) frameworks constructed from digital workflow (CAD/CAM; rapid prototyping) and conventional techniques were included.

    Results: Nine full-text articles comprising 6 in vitro and 3 in vivo studies were included in this review. The digital RPDs were fabricated in all articles by CAD/CAM selective laser sintering and selective laser melting techniques. The articles that have used CAD/CAM and rapid prototyping technique demonstrated better fit and accuracy as compared to the RPDs fabricated through conventional techniques. The least gaps between the framework and cast (41.677 ± 15.546 μm) were found in RPDs constructed through digital CAD/CAM systems.

    Conclusion: A better accuracy was achieved using CAD/CAM and rapid prototyping techniques. The RPD frameworks fabricated by CAD/CAM and rapid prototyping techniques had clinically acceptable fit, superior precision, and better accuracy than conventionally fabricated RPD frameworks.

    Matched MeSH terms: Computer-Aided Design/trends
  9. Abd Razak NA, Abu Osman NA, Gholizadeh H, Ali S
    Biomed Eng Online, 2014 Apr 23;13:49.
    PMID: 24755242 DOI: 10.1186/1475-925X-13-49
    BACKGROUND: The design and performance of a new development prosthesis system known as biomechatronics wrist prosthesis is presented in this paper. The prosthesis system was implemented by replacing the Bowden tension cable of body powered prosthesis system using two ultrasonic sensors, two servo motors and microcontroller inside the prosthesis hand for transradial user.

    METHODS: The system components and hand prototypes involve the anthropometry, CAD design and prototyping, biomechatronics engineering together with the prosthetics. The modeler construction of the system develop allows the ultrasonic sensors that are placed on the shoulder to generate the wrist movement of the prosthesis. The kinematics of wrist movement, which are the pronation/supination and flexion/extension were tested using the motion analysis and general motion of human hand were compared. The study also evaluated the require degree of detection for the input of the ultrasonic sensor to generate the wrist movements.

    RESULTS: The values collected by the vicon motion analysis for biomechatronics prosthesis system were reliable to do the common tasks in daily life. The degree of the head needed to bend to give the full input wave was about 45°-55° of rotation or about 14 cm-16 cm. The biomechatronics wrist prosthesis gave higher degree of rotation to do the daily tasks but did not achieve the maximum degree of rotation.

    CONCLUSION: The new development of using sensor and actuator in generating the wrist movements will be interesting for used list in medicine, robotics technology, rehabilitations, prosthetics and orthotics.

    Matched MeSH terms: Computer-Aided Design
  10. Chan YJ, Chong MF, Law CL
    Bioresour Technol, 2012 Dec;125:145-57.
    PMID: 23026327 DOI: 10.1016/j.biortech.2012.08.118
    Thermophilic treatment of palm oil mill effluent (POME) was studied in a novel integrated anaerobic-aerobic bioreactor (IAAB). The IAAB was subjected to a program of steady-state operation over a range of organic loading rate (OLR)s, up to 30 g COD/L day in order to evaluate its treatment capacity. The thermophilic IAAB achieved high chemical oxygen demand (COD), biochemical oxygen demand (BOD) and total suspended solids (TSS) removal efficiencies of more than 99% for OLR up to 18.5 g COD/L day. High methane yield of 0.32 LCH(4) (STP)/g COD(removed) with compliance of the final treated effluent to the discharge limit were achieved. This is higher than that of the mesophilic system due to the higher maximum specific growth rate (μ(max)) of the thermophilic microorganisms. Besides, coupling the model of Grau second order model (anaerobic system) with the model of Monod (aerobic system) will completely define the IAAB system.
    Matched MeSH terms: Computer-Aided Design
  11. Rene ER, Kar S, Krishnan J, Pakshirajan K, López ME, Murthy DV, et al.
    Bioresour Technol, 2015 Aug;190:529-35.
    PMID: 25827361 DOI: 10.1016/j.biortech.2015.03.049
    The performance of a compost biofilter inoculated with mixed microbial consortium was optimized for treating a gas-phase mixture of benzene and toluene. The biofilter was acclimated to these VOCs for a period of ∼18d. The effects of concentration and flow rate on the removal efficiency (RE) and elimination capacity (EC) were investigated by varying the inlet concentration of benzene (0.12-0.95g/m(3)), toluene (0.14-1.48g/m(3)) and gas-flow rate (0.024-0.072m(3)/h). At comparable loading rates, benzene removal in the mixture was reduced in the range of 6.6-41% in comparison with the individual benzene degradation. Toluene removal in mixture was even more affected as observed from the reductions in REs, ranging from 18.4% to 76%. The results were statistically interpreted by performing an analysis of variance (ANOVA) to elucidate the main and interaction effects.
    Matched MeSH terms: Computer-Aided Design
  12. Goo CL, Tan KB
    Case Rep Dent, 2017;2017:9373818.
    PMID: 28396807 DOI: 10.1155/2017/9373818
    This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.
    Matched MeSH terms: Computer-Aided Design
  13. Mohd Faiz Nasruddin, Theocharospoulos, Antonios, Ray, Noel, Burke, Francis M.
    MyJurnal
    Fitting accuracy of dental prostheses is essential for clinical success. An ideal marginal and internal fit will minimize plaque accumulation, gingival irritation, cement dissolution and micro leakage as well as enhancing the mechanical behaviour of a fixed partial denture (FPD) (1). Unfortunately, there is disagreement about acceptable marginal and internal fit discrepancies of FPD’s (2) from 75-200μm. There are two main manufacturing routes of CAD/CAM FPD’s: the subtractive and the additive route. The subtractive route is a top-down approach which involves milling the desired article out of a block of the material of choice using a series of burs. This route is currently the most common CAD/CAM technique for the fabrication of metal alloy FPD’s. The additive route is a bottom-up approach where the desired article is fabricated layer by layer out of the material of choice. Examples include selective laser sintering and selective laser melting for metal alloy FPD’s.
    Matched MeSH terms: Computer-Aided Design
  14. Nik Zarina Nik Mahmood, Noor Hayaty Abu Kasim, Mamat Azuddin, Noor Lide Abu Kassim
    Compendium of Oral Science, 2015;2(1):21-31.
    MyJurnal
    Objective: To evaluate the effect of type of viscosity and groove on surface detail reproduction of elastomeric impression materials. Methods: Two polyvinylsiloxane and polyether elastomeric impression materials were investigated. An aluminium cylindrical reference block with V- and U-shaped grooves of 1 mm and 2 mm in depth was machined using CAD-CAM system. Impressions of the block were taken to produce 35 master dies. Each die was immersed in distilled water for 5 minutes prior to impression making. Surface topography of the dies and impressions were captured using Alicona Imaging System. Mean difference in depth between the mas-ter dies and corresponding impressions’ grooves were analyzed. Results: Type of viscosities and groove showed significant main effects on surface detail (p < .01), but no significant interaction was observed between the two (p > .01). Express™ putty/light exhibited the lowest mean difference in depth for all grooves. The highest mean difference for U1 (38.3μm ± 21.55), U2 (52.96μm ± 30.39),V1 (45.02μm ± 34.82) and V2 (58.44μm ± 44.19) was obtained from Impregum medium, Aquasil medium, Impregum™ heavy/light and Impregum™ heavy/light groups respectively. Conclusion: Express putty/light-bodied material produced the best surface detail, and U-shaped groove showed superior detail reproduction.
    Matched MeSH terms: Computer-Aided Design
  15. Farook TH, Jamayet NB, Abdullah JY, Asif JA, Rajion ZA, Alam MK
    Comput Biol Med, 2020 03;118:103646.
    PMID: 32174323 DOI: 10.1016/j.compbiomed.2020.103646
    OBJECTIVE: To design and compare the outcome of commercial (CS) and open source (OS) software-based 3D prosthetic templates for rehabilitation of maxillofacial defects using a low powered personal computer setup.

    METHOD: Medical image data for five types of defects were selected, segmented, converted and decimated to 3D polygon models on a personal computer. The models were transferred to a computer aided design (CAD) software which aided in designing the prosthesis according to the virtual models. Two templates were designed for each defect, one by an OS (free) system and one by CS. The parameters for analyses were the virtual volume, Dice similarity coefficient (DSC) and Hausdorff's distance (HD) and were executed by the OS point cloud comparison tool.

    RESULT: There was no significant difference (p > 0.05) between CS and OS when comparing the volume of the template outputs. While HD was within 0.05-4.33 mm, evaluation of the percentage similarity and spatial overlap following the DSC showed an average similarity of 67.7% between the two groups. The highest similarity was with orbito-facial prostheses (88.5%) and the lowest with facial plate prosthetics (28.7%).

    CONCLUSION: Although CS and OS pipelines are capable of producing templates which are aesthetically and volumetrically similar, there are slight comparative discrepancies in the landmark position and spatial overlap. This is dependent on the software, associated commands and experienced decision-making. CAD-based templates can be planned on current personal computers following appropriate decimation.

    Matched MeSH terms: Computer-Aided Design*
  16. Nejat P, Calautit JK, Abd Majid MZ, Hughes BR, Zeynali I, Jomehzadeh F
    Data Brief, 2016 Dec;9:448-452.
    PMID: 27709121
    The data presented in this article were the basis for the study reported in the research articles entitled "Evaluation of a two-sided windcatcher integrated with wing wall (as a new design) and comparison with a conventional windcatcher" (P. Nejat, J.K. Calautit, M.Z.A. Majid, B.R. Hughes, I. Zeynali, F. Jomehzadeh, 2016) [1] which presents the effect of wing wall on the air flow distribution under using the windcatchers as a natural ventilation equipment. Here, we detail the wind tunnel testing and numerical set-up used for obtaining the data on ventilation rates and indoor airflow distribution inside a test room with a two-sided windcatcher and wing wall. Three models were integrated with wing wall angled at 30°, 45° and 60° and another windcatcher was a conventional two-sided device. The computer-aided design (CAD) three-dimensional geometries which were produced using Solid Edge modeler are also included in the data article.
    Matched MeSH terms: Computer-Aided Design
  17. Kul E, Abdulrahim R, Bayındır F, Matori KA, Gül P
    Dent Med Probl, 2021 5 14;58(2):187-191.
    PMID: 33982454 DOI: 10.17219/dmp/126745
    BACKGROUND: If a temporary restoration is in the esthetic area and needs to be worn for a long time, the color stability of temporary materials becomes an important factor.

    OBJECTIVES: The aim of this in vitro study was to evaluate the long-term effects of various staining solutions on the color stability of different temporary materials produced with the computer-aided design and computer-aided manufacturing (CAD/CAM) technology.

    MATERIAL AND METHODS: In the study, the following materials were used: VITA CAD-Temp® (group 1); Ceramill® Temp (group 2); and Telio® CAD (group 3). Forty disk-shaped specimens (10 mm in diameter, 2 mm in thickness) of each material (N = 120) were produced with a CAD/CAM system. Staining solutions - of tea (A), of coffee (B) and cola (C) - and distilled water (D, control) were used, and color was evaluated before and after storing the samples in the solutions. Measurements were taken with a spectrophotometer and the color parameters (L*, a*, b*, and ΔE) were calculated according to the Commission internationale de l'éclairage system (CIELab). The results were evaluated with the two-way analysis of variance (ANOVA) and Tukey's tests (α = 0.05).

    RESULTS: Clinically perceivable (ΔE00 > 0.8) and statistically significant (p < 0.001) color differences were detected in all specimens. The highest ΔE00 value was found in the Ceramill Temp specimens. In addition, the highest ΔE00 values were noted for the specimens stored in cola and the coffee solution for all groups. The lowest ΔE00 value was observed for the groups stored in the tea solution.

    CONCLUSIONS: Clinically perceivable color changes were observed in all the specimens kept in the solutions. Color changes were greater for cola and coffee as compared to tea.

    Matched MeSH terms: Computer-Aided Design*
  18. Hassan LA, Goo CL
    Dent Mater J, 2021 Sep 30;40(5):1189-1195.
    PMID: 34078778 DOI: 10.4012/dmj.2020-408
    This research aimed to evaluate the effect of cement space on the marginal discrepancy and retention of computer-aided design/computer-aided manufacturing (CAD/CAM) crowns. A total of 30 premolar Frasaco teeth were machined to receive crowns with cement spaces of 70, 90, and 110 μm. The marginal discrepancy measurements were done before and after cementation. Pull-off test was conducted using universal testing machine (UTM). Data was analyzed using two-way mixed ANOVA with post-hoc Bonferroni test and Kruskal-Wallis test. The crowns with cement space of 70 μm showed a significantly higher absolute marginal discrepancy than those with 90 and 110 μm. No significant effect on the crown retention was found. Within the limitations of this study, modifying cement space to 90 μm and 110 μm may improve the marginal adaptation of CAD/CAM crown, whereas adjusting cement space from 70 to 110 μm did not significantly affect the crown retention.
    Matched MeSH terms: Computer-Aided Design
  19. Jalal Abdullah S, Shaikh Mohammed J
    Disabil Rehabil Assist Technol, 2019 11;14(8):849-858.
    PMID: 30556753 DOI: 10.1080/17483107.2018.1539130
    Purpose: Some wheelchair users continue to struggle in maneuvering a wheelchair and navigating through manual doors. Several smart wheelchairs and robotic manipulators were developed to minimize such challenges facing disabled people. Disappointingly, a majority of these high-tech solutions are restricted to laboratories and are not extensively available as commercial products. Previously, a low-tech wheelchair accessory (arc-shaped with many wheels) for pushing doors was modelled and simulated. This work demonstrates the fabrication and testing of the first-generation prototype of the accessory.Materials and methods: The accessory has side portions with a straight arrangement of wheels and a front portion with a straight-arc-straight arrangement of wheels. The accessory was fabricated using conventional manufacturing, off-the-shelf components, and 3D printed ABS fasteners. Stress analysis simulations were done for the fasteners that attach the front accessory to the wheelchair frame. The proof-of-concept of the prototype installed onto a powered wheelchair was tested with a door and an obstacle, each with ∼50 N resistance force.Results: Prototype tests demonstrate the ability of the accessory along with the mechanical robustness of the 3D printed fasteners to push open doors allowing easy navigation through doors and to push/glide against obstacles. The accessory is foldable and detachable.Conclusion: The low-cost of the accessory makes it affordable to many users intending to improve their quality of life. The current study provides an engineering perspective of the accessory, and a clinical perspective is crucial. Other potential applications of the wheelchair accessory include use with scooters, walkers and stretchers.Implications for rehabilitationLow-cost, low-tech accessory is foldable and detachable.Accessory is effective for pushing doors and pushing/gliding against obstacles.Protective nature of the front accessory could prove highly beneficial to some wheelchair users.
    Matched MeSH terms: Computer-Aided Design
  20. Abdul Hamid NF, Wan Bakar WZ, Ariffin Z
    Eur J Dent, 2019 Feb;13(1):17-21.
    PMID: 31170751 DOI: 10.1055/s-0039-1688740
    OBJECTIVE: This study was carried out to assess and compare the marginal gap of conventionally used metal onlays and new resin nanoceramic (RNC) (Lava Ultimate block) onlays.

    MATERIALS AND METHODS: This is an in vitro study using two extracted sound human mandibular molars. One tooth was prepared to receive the metal onlays and another one for the RNC onlays which were fabricated using the computer-aided design and computer-aided manufacturing (CAD/CAM) technology. Twelve metals and 12 ceramic onlays were fabricated before they were placed at their respective preparation and examined under the Leica stereomicroscope, M125C (Leica Microsystems, Wetzlar, Germany) for a marginal analysis. The gap width was measured at 10 predefined landmarks which included 3 points on the buccal and lingual surfaces each and 2 points each on the mesial and distal surfaces, respectively.

    STATISTICAL ANALYSIS: Mann-Whitney post hoc test was used for statistical analysis (P ≤ 0.05).

    RESULTS: Overall, the RNC onlays showed significant lower marginal gap with the exception of the landmarks 5 and 6 (on distolingual) and no significant difference at landmark 7 (on midlingual). It was observed that the marginal gap were all within the clinically acceptable limit of 120 μm.

    CONCLUSIONS: Based on the results obtained, it can be concluded that the RNC CAD/CAM onlays are a promising alternative to the metal onlays.

    Matched MeSH terms: Computer-Aided Design
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links