Displaying publications 1 - 20 of 82 in total

Abstract:
Sort:
  1. Gupta K, Singh S, Singh S
    J Contemp Dent Pract, 2019 Aug 01;20(8):907-914.
    PMID: 31797846
    AIM: Assessing the accuracy of surgical guides generated with the help of a simple chair side ridge mapping technique by comparing the planned implant position with the achieved implant position on post-op computerized tomography scans.

    MATERIALS AND METHODS: In this study, 20 implant sites in patients were selected. Ridge mapping was done through a vacuum press template at three buccal (B1, B2, B3), three lingual (L1, L2, L3), and one crestal (C) points for each implant site. Readings were transferred onto the cast, and surgical guides were fabricated for implant placement. Postoperative cone beam computerized tomography (CBCT) was done to assess planned and achieved implant position. Comparison was done between soft tissue depths and implant distance from the crest of alveolar bone determined by the ridge mapping technique with measurements done on CBCT. The points used for ridge mapping were used as the reference for measurements. The data were analyzed using paired t test. p < 0.05 was considered to be statistically significant.

    RESULTS: On comparing the mean values of soft tissue depths from the ridge mapping and CBCT data, insignificant differences were found at B1, B2, L1, L2, L3, and C, but significant differences were found at B3. On comparing the implant distances from alveolar bone from both the data, insignificant differences were found at B, B2, B3, L1, L2, and L3 and significant difference was found at the crest in the mean values.

    CONCLUSION: Under the limitations of the above study, it can be concluded that a simple chairside procedure like ridge mapping can be used as an effective way for guided implant placement in sufficient available alveolar bone.

    Matched MeSH terms: Cone-Beam Computed Tomography*
  2. Yusof MYPM, Mah MC, Reduwan NH, Kretapirom K, Affendi NHK
    Saudi Dent J, 2020 Dec;32(8):396-402.
    PMID: 33304083 DOI: 10.1016/j.sdentj.2019.10.010
    Objective: Knowledge and evaluation of the blood supply within the maxillary sinus before sinus augmentation are vital to avoid surgical complications. The lateral maxilla is supplied by branches of the posterior superior alveolar artery and infraorbital artery forming intraosseous anastomoses (IA) within the bony lateral antral wall. This study was undertaken to (i) measure mean diameter of IA and its distance from the alveolar ridge within dentate and posteriorly edentulous subjects and, (ii) qualitatively display the relationship of IA throughout its course within the lateral maxillary sinus in cone beam computed tomography (CBCT).

    Method: Maxillary CBCT images of two-hundred-and-fifty-seven consecutive patients (163 men, 94 women, mean age 42 years) were analyzed. Samples were later divided into dentate (n = 142) and posteriorly edentulous (n = 115) jaws. Using both alveolar ridge and tooth location as reference points, the distance and diameter of IA were assessed.

    Result: The IA was seen in 63.7% of all sinuses with 68.2% in dentate and 62.4% in edentulous. Mean distance and diameter of IA across the posterior tooth locations were 17.9 ± 3.0 mm and 1.4 ± 0.5 mm (dentate) and 15.1 ± 3.0 mm and 1.0 ± 0.5 mm (posteriorly edentulous), respectively. In each sample, there were no significant differences in distance-alveolar ridge and no significant correlations in diameter-tooth location. A statistically significant Pearson coefficient correlation between diameter and distance in dentate state was observed (r = -0.6).

    Conclusion: This study reveals that dentate maxillary jaws present larger diameters as compared to posteriorly edentulous jaws, although the IA course remains the same. As these canal structures contain neurovascular bundles with diameters that may be large enough to cause clinically substantial complications, a thorough pre-surgical planning is therefore highly advisable.

    Matched MeSH terms: Cone-Beam Computed Tomography; Spiral Cone-Beam Computed Tomography
  3. Tan WY, Ng JZL, Ajit Bapat R, Vijaykumar Chaubal T, Kishor Kanneppedy S
    J Prosthet Dent, 2021 May;125(5):766.e1-766.e8.
    PMID: 33752904 DOI: 10.1016/j.prosdent.2021.02.018
    STATEMENT OF PROBLEM: Lingual plate perforation can be life-threatening when vital structures are damaged during implant placement. Knowledge of the anatomy of lingual concavities is imperative for safe implant surgery.

    PURPOSE: The purpose of this clinical study was to determine the prevalence of type of posterior mandibular ridge morphology in a Malaysian population and to evaluate the buccolingual width of the alveolar ridge (Wb and Wc); alveolar ridge height (Vcb); and concavity angle, length, and depth for both left and right first and second molars in different age groups and sexes by using cone beam computed tomography (CBCT).

    MATERIAL AND METHODS: Bilateral posterior mandibular lingual concavities at the first and second molars were retrospectively studied in cross-sectional views of 150 CBCT scans (n=600 sites evaluated). The sample size was calculated at a power of 80%, confidence interval of 95%, and margin of error of .05. The buccolingual width from the base and crest of the ridge and the ridge height were measured to determine the type of ridge. For the U-shaped ridge, the concavity angle, length, and depth were assessed. The independent t test was used to compare mean values of CBCT measurements between sexes and tooth type, while the ANOVA and Pearson chi-squared test were used to determine the correlations with age groups and types of ridge morphology, respectively. To compare the left and right readings for first and second molars in the same patient, the paired t test was performed (α=.05 for all tests).

    RESULTS: The Pearson correlation showed a strong agreement between the 2 examiners with an interobserver reliability of 87.3%. Significant difference was noted in all dimensional measurements when comparing right and left first and second molars (P

    Matched MeSH terms: Cone-Beam Computed Tomography*
  4. Voon YS, Patil PG
    J Prosthet Dent, 2018 Apr;119(4):568-573.
    PMID: 28838820 DOI: 10.1016/j.prosdent.2017.05.011
    STATEMENT OF PROBLEM: The genial tubercle is a clinically palpable landmark in the mandible and can be identified in cone beam computed tomography (CBCT). Its location can be used to measure the safe zone in the interforaminal region of the mandible. These measurements may be helpful for implant treatment planning in patients with complete edentulism.

    PURPOSE: The purpose of this clinical study was to evaluate the safe distance in the interforaminal region of the mandible measured from the genial tubercle level for implant osteotomy in a Chinese-Malaysian population.

    MATERIAL AND METHODS: A total of 201 Digital Imaging and Communications in Medicine (DICOM) files were selected for the study from the CBCTs of dentate or edentulous Chinese-Malaysian adult patients with ongoing or completed treatments. Measurements were made with implant planning software. The anatomy of the whole mandible was assessed in the coronal cross-sectional, horizontal view and in panoramic view. Measurements were obtained in millimeters on one side by locating and marking a genial tubercle and then marking the mesial margin of the mental foramen and the anterior loop of the inferior alveolar nerve. The corresponding points of these landmarks were identified on the crest of the mandibular ridge to measure the linear distances. All the measurement steps were repeated on the other side. The linear distance of 2 mm was deducted from the total distance between the genial tubercle and the anterior loop separately for left and right side measurements to identify the safe zone. The mixed 2-way analysis of variance (ANOVA) test was used to analyze side and sex-related variations.

    RESULTS: The mean safe zone measured at the crestal level from the genial tubercle site on the left side of the mandible was 21.12 mm and 21.67 mm on the right side. A statistically significant (P

    Matched MeSH terms: Cone-Beam Computed Tomography*
  5. Wong SK, Patil PG
    J Prosthet Dent, 2018 Aug;120(2):210-213.
    PMID: 29551376 DOI: 10.1016/j.prosdent.2017.10.019
    STATEMENT OF PROBLEM: The inferior alveolar nerve (IAN) frequently loops backward before exiting from the mental foramen and spreads several millimeters medially to the foramen. Implant placement in this area may damage the nerve if the anterior loop area is not carefully identified in a radiographic or computed tomography (CT) evaluation.

    PURPOSE: The purpose of this observational study was to measure the prevalence of the presence of the anterior loop and to estimate sex and ethnicity-related variations in anterior loop length in the Malaysian population.

    MATERIAL AND METHODS: A total of 100 cone beam computed tomography (CBCT) Digital Imaging and Communications in Medicine (DICOM) files were selected from a pool of 810 ongoing or completed patients in 3 different ethnic groups: Malay (33), Indian (33), and Chinese (34). The DICOM data were imported into commercial software. The IAN was traced with software along with the anterior loop and part of the incisive nerve. The vertical length of the nerve was estimated from the canal to the opening of the mental foramen from the cross-sectional view and translated to the panoramic view. Measurement was made from this point to the most anterior point of the anterior loop by following the trajectory of the nerve and was repeated on the opposite side. A 2-way mixed analysis of variance (ANOVA) test was carried out to evaluate the sex- and ethnicity-related variations (α=.05).

    RESULTS: The anterior loop was present in 94% of the 100 participants. Overall anterior loop length (AnLL) ranged between 0.73 and 7.99 mm with a mean length of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side. Among all participants, no statistically significant differences were found between the left and right sides of the mandible (P=.379). Overall, no significant main effect of ethnicity (P=.869) or sex (P=.576) was found on AnLL measurements. Also, with multiple comparisons, no significant effect was found between each pair of ethnic groups. Men in all 3 ethnic groups had greater AnLL than women.

    CONCLUSIONS: The anterior loop was present in 94% of the 100 participants among the 3 major ethnic groups of Malaysia. Overall AnLL ranged between 0.73 and 7.99 mm and mean lengths of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side, with no significant ethnicity- or sex-related variations.

    Matched MeSH terms: Cone-Beam Computed Tomography/methods
  6. Lim D, Parumo R, Chai MB, Shanmuganathan J
    J Oral Implantol, 2017 Jun;43(3):228-231.
    PMID: 27996585 DOI: 10.1563/aaid-joi-D-16-00172
    Displacement of dental implants into the maxillary sinus is a rare complication. This article presents a case of displaced dental implant into maxillary sinus. Retrieval of the dental implant from left maxillary sinus was performed via endoscopic sinus surgery. This case highlighted a delayed referral of a 53-year-old male by a general dental practitioner for management of a dislodged dental implant into the left maxillary antrum. The implant was dislodged during placement of a healing abutment 4 months after implant insertion to replace missing 25. Cone beam computerized tomography revealed the displaced implant was located at the ostium of the left nose. A sudden change in sinonasal pressure when the patient took a deep breath during the procedure may have created a negative pressure and suction effect causing the implant to be dislodged and embedded at the ostium. In view of its position, a referral to an otorhinolaryngologist was made for endoscopic removal of the displaced implant. This case also highlighted the need for inter disciplinary cooperation in the management of such a complication for the best interest of the patients.
    Matched MeSH terms: Cone-Beam Computed Tomography
  7. Qabbani AA, Razak NHA, Kawas SA, Sheikh Abdul Hamid S, Wahbi S, Samsudin AR
    J Craniofac Surg, 2017 Jun;28(4):e318-e325.
    PMID: 28230596 DOI: 10.1097/SCS.0000000000003569
    The aim of this study was to determine the efficacy of immediate implant placement with alveolar bone augmentation on socket preservation following atraumatic tooth extraction and comparing it with a tooth alveolar socket that was allowed to heal in a conventional way.Twenty medically fit patients (8 males and 12 females aged between 18 and 40 years) who needed noncomplicated tooth extraction of mandibular premolar teeth were divided randomly and equally into 2 groups. In Group I, the empty extraction socket was left untreated and allowed to heal in a conventional way. In Group II, the immediate implant was placed and the gap between the implant and the inner buccal plate surface of the socket wall was filled with lyophilized bovine bone granules and the wound was covered with pericardium membrane. The patients were followed up clinically and radiologically for regular reviews at 1 week, 3 months, and 9 months postoperative. Cone beam computerized tomography images of the alveolar ridge and socket were analyzed to determine the structural changes of the alveolar ridge. Resonance frequency analysis was measured at 9 months for Group II to assess the degree of secondary stability of the implants by using Osstell machine.A significant difference of bone resorption of 1.49 mm (confidence interval, CI 95%, 0.63-2.35) was observed within the control group at 3 months, and 1.84 mm (P ≤ 0.05) at 9 months intervals. No significant changes of bone resorption were observed in Group II. Comparison between groups showed a highly significant difference at 3 months; 2.56 mm (CI 95% 4.22-0.90) and at 9 months intervals; 3.2 mm (CI 95%, 4.70-1.62) P ≤ 0.001 between Group I and II. High resonance frequency analysis values were observed at 9 months postoperative in Group II.In conclusion, the insertion of immediate implants in fresh extraction sockets together with grafting the circumferential gap between the bony socket wall and the implant surface with bovine bone granules was able to preserve a greater amount of alveolar ridge volume when compared with an extraction socket that was left to heal in a conventional way.
    Matched MeSH terms: Cone-Beam Computed Tomography/methods
  8. Beh YH, Farook TH, Jamayet NB, Dudley J, Rashid F, Barman A, et al.
    Cleft Palate Craniofac J, 2021 03;58(3):386-390.
    PMID: 32808548 DOI: 10.1177/1055665620950074
    OBJECTIVE: The virtual cone beam computed tomography-derived 3-dimensional model was compared with the scanned conventional model used in the fabrication of a palatal obturator for a patient with a large palatal defect.

    DESIGN: A digitally derived 3-dimensional maxillary model incorporating the palatal defect was generated from the patient's existing cone beam computerized tomography data and compared with the scanned cast from the conventional impression for linear dimensions, area, and volume. The digitally derived cast was 3-dimensionally printed and the obturator fabricated using traditional techniques. Similarly, an obturator was fabricated from the conventional cast and the fit of both final obturator bulbs were compared in vivo.

    RESULTS: The digitally derived model produced more accurate volumes and surface areas within the defect. The defect margins and peripheries were overestimated which was reflected clinically.

    CONCLUSION: The digitally derived model provided advantages in the fabrication of the palatal obturator; however, further clinical research is required to refine consistency.

    Matched MeSH terms: Cone-Beam Computed Tomography
  9. Ananda GK, Nambiar P, Mutalik S, Shanmuhasuntharam P
    Surg Radiol Anat, 2015 Nov;37(9):1099-108.
    PMID: 25850735 DOI: 10.1007/s00276-015-1473-0
    With the advent of cone-beam computed tomography (CBCT) for maxillofacial imaging, there has been a paradigm shift from two dimensional panoramic radiography to three dimensional imaging. This study investigated the microanatomy of the maxillary permanent first molar socket and its relationship to the floor of the maxillary sinus, especially for immediate or early implant placement.
    Matched MeSH terms: Cone-Beam Computed Tomography
  10. Azizah Ahmad Fauzi, Mohamed Ebrahim Parker, Norval E., Phrabhakaran N
    Sains Malaysiana, 2017;46:59-65.
    Cone-beam-computed-tomography (CBCT) has been useful in providing insights of relevant anatomy prior to surgical
    procedures, including the assessment of the proximity of impacted mandibular-third-molar to the inferior-alveolar-canal
    (IAC). It is important to understand the reliability of conventional panoramic-radiograph in the assessment of this criterion
    since it is more commonly used as first line radiographic approach due to its availability and lower radiation dose. This
    study aimed to investigate the reliability of conventional panoramic-radiograph in the evaluation of the proximity of
    impacted mandibular-third-molar root tip to the IAC by correlating the results with CBCT. A total of 65 root tips of impacted
    mandibular-third-molars that had both panoramic radiographs and CBCT images were included in this retrospective study.
    Two trained observers participated in all image evaluations. A prepared standard 1 cm ruler was used to measure the
    proximity of the third-molar root apices to the IACs. Measurements recorded in this study were categorized into positive
    (root apex above a roof of IAC), zero (root apex was superimposed on IAC) and negative (root apex below a roof of IAC).
    Data analysis was carried out using student t-test. In this study, both observers recorded statistically significant differences
    in the measurement between third-molars root apices and the IAC from panoramic radiographs and CBCT images. The low
    reliability of panoramic radiograph to assess the vertical proximity between these two anatomical structures suggests
    the importance of additional assessment with CBCT in cases where panoramic radiograph shows superimposition of the
    third molar root on the roof of the canal and presence of root below the roof of the IAC.
    Matched MeSH terms: Cone-Beam Computed Tomography
  11. Asif MK, Nambiar P, Khan IM, Aziz ZABCA, Noor NSBM, Shanmuhasuntharam P, et al.
    Radiol Case Rep, 2019 Dec;14(12):1545-1549.
    PMID: 31719943 DOI: 10.1016/j.radcr.2019.10.001
    A patient was referred to the Oral and Maxillofacial Imaging Division and the attending dental specialist suspected a foreign object at the anterior region of the maxilla. The region was scanned using Kodak 9000 3D cone-beam computed tomography (CBCT) extraoral imaging system (Carestream Health, Inc.) to determine the type and morphometric characteristic of foreign object. The CBCT images failed to determine the identity and nature of the foreign object. CBCT images were then exported to the Materialise Interactive Medical Image Control System (Mimics) software to evaluate whether this software can help in enhancing the visualization of the foreign object in the maxillofacial region. The findings showed that there was an improved visualization of the foreign body and the type of the object could be determined with certainty. The object was identified as an endodontic file and was clearly visible when visualized as a reconstructed 3D model in Mimics software. Although the identification of abnormalities has been dramatically improved using 3D scans, the visualization can be further enhanced using image processing software like Mimics.
    Matched MeSH terms: Cone-Beam Computed Tomography
  12. Rabba JA, Suhaimi FM, Mat Jafri MZ, Jaafar HA, Osman ND
    Radiography (Lond), 2023 May;29(3):533-538.
    PMID: 36913788 DOI: 10.1016/j.radi.2023.02.028
    INTRODUCTION: The daily image quality assessment involves large datasets that consume a lot of time and effort. This study aims to evaluate a proposed automated calculator for image distortion analysis in 2-dimensional (2D) panoramic imaging mode for a dental cone beam computed tomography (CBCT) system in comparison with present manual calculations.

    METHODS: A ball phantom was scanned using panoramic mode of the Planmeca ProMax 3D Mid CBCT unit (Planmeca, Helsinki, Finland) with standard exposure settings used in clinical practice (60 kV, 2 mA, and maximum FOV). An automated calculator algorithm was developed in MATLAB platform. Two parameters associated with panoramic image distortion such as balls diameter and distance between middle and tenth balls were measured. These automated measurements were compared with manual measurement using the Planmeca Romexis and ImageJ software.

    RESULTS: The findings showed smaller deviation in distance difference measurements by proposed automated calculator (ranged 3.83 mm) as compared to manual measurements (ranged 5.00 for Romexis and 5.12 mm for ImageJ software). There was a significant difference (p 

    Matched MeSH terms: Cone-Beam Computed Tomography/methods; Spiral Cone-Beam Computed Tomography*
  13. Cheng CS, Jong WL, Ung NM, Wong JHD
    Radiat Prot Dosimetry, 2017 Jul 01;175(3):357-362.
    PMID: 27940494 DOI: 10.1093/rpd/ncw357
    This work evaluated and compared the absorbed doses to selected organs in the head and neck region from the three image guided radiotherapy systems: cone-beam computed tomography (CBCT) and kilovoltage (kV) planar imaging using the On-board Imager® (OBI) as well as the ExacTrac® X-ray system, all available on the Varian Novalis TX linear accelerator. The head and neck region of an anthropomorphic phantom was used to simulate patients' head within the imaging field. Nanodots optically stimulated luminescent dosemeters were positioned at selected sites to measure the absorbed doses. CBCT was found to be delivering the highest dose to internal organs while OBI-2D gave the highest doses to the eye lenses. The setting of half-rotation in CBCT effectively reduces the dose to the eye lenses. Daily high-quality CBCT verification was found to increase the secondary cancer risk by 0.79%.
    Matched MeSH terms: Cone-Beam Computed Tomography*
  14. Abuzaid MM, Elshami W, Tekin HO, Sulieman A, Bradley DA
    Radiat Prot Dosimetry, 2021 Nov 03;196(1-2):10-16.
    PMID: 34423365 DOI: 10.1093/rpd/ncab125
    The present study compares three different multidetector CT (MDCT) scanners for routine brain imaging in terms of image quality and radiation doses. The volume CT dose index (CTDIvol), dose-length product (DLP), and effective dose (E) were calculated. Subjective image assessment was obtained based on a scale ranging from 1 (unacceptable) to 5 (optimum). All images scored 3.5 or over, with the 160-slice MDCT images being favoured. For the 4-, 16- and 160-slice MDCT scanners, the respective median values for CTDIvol were 57 mGy, 41 mGy, and 28 mGy; DLP values were 901 mGy.cm, 680 mGy.cm, and 551 mGy.cm; and effective doses were 2 mSv, 1.5 mSv, and 1 mSv, respectively. Compared to the 160-slice MDCT, the dose values for the 4- and 16-slice units were significantly greater. In practice, the CT modality used must be carefully selected to avoid elevated radiation doses and maintain image quality.
    Matched MeSH terms: Cone-Beam Computed Tomography
  15. Arora S, Kanneppady SK, Banavar SR, Jnanendrappa N
    QJM, 2019 Aug 01;112(8):615-616.
    PMID: 31120127 DOI: 10.1093/qjmed/hcz117
    Matched MeSH terms: Cone-Beam Computed Tomography
  16. Al-Amery SM, Nambiar P, Jamaludin M, John J, Ngeow WC
    PLoS One, 2015;10(2):e0117251.
    PMID: 25679505 DOI: 10.1371/journal.pone.0117251
    The maxillary incisive canal connects the roof of the oral cavity with the floor of nasal cavity and has the incisive and nasal foramina respectively at its two opposite ends. Its close proximity with the anterior incisors affects one's ability to place immediate implants in ideal position.
    Matched MeSH terms: Cone-Beam Computed Tomography*
  17. Purmal K, Alam MK, Pohchi A, Abdul Razak NH
    PLoS One, 2013;8(12):e84202.
    PMID: 24367643 DOI: 10.1371/journal.pone.0084202
    Intermaxillary (IMF) screws feature several advantages over other devices used for intermaxillary fixation, but using cone beam computed tomography (CBCT) scans to determine the safe and danger zones to place these devices for all patients can be expensive. This study aimed to determine the optimal interradicular and buccopalatal/buccolingual spaces for IMF screw placement in the maxilla and mandible. The CBCT volumetric data of 193 patients was used to generate transaxial slices between the second molar on the right to the second molar on the left in both arches. The mean interradicular and buccopalatal/buccolingual distances and standard deviation values were obtained at heights of 2, 5, 8 and 11 mm from the alveolar bone crest. An IMF screw with a diameter of 1.0 mm and length of 7 mm can be placed distal to the canines (2 - 11 mm from the alveolar crest) and less than 8 mm between the molars in the maxilla. In the mandible, the safest position is distal to the first premolar (more than 5 mm) and distal to the second premolar (more than 2 mm). There was a significant difference (p<0.05) between the right and left quadrants. The colour coding 3D template showed the safe and danger zones based on the mesiodistal, buccopalatal and buccolingual distances in the maxilla and mandible.The safest sites for IMF screw insertion in the maxilla were between the canines and first premolars and between the first and second molars. In the mandible, the safest sites were between the first and second premolars and between the second premolar and first molar. However, the IMF screw should not exceed 1.0 mm in diameter and 7 mm in length.
    Matched MeSH terms: Cone-Beam Computed Tomography*
  18. Al-koshab M, Nambiar P, John J
    PLoS One, 2015;10(3):e0121682.
    PMID: 25803868 DOI: 10.1371/journal.pone.0121682
    INTRODUCTION: Proper imaging allows practitioners to evaluate an asymptomatic tempormandibular joint (TMJ) for potential degenerative changes prior to surgical and orthodontic treatment. The recently developed cone-beam computed tomography (CBCT) allows measurement of TMJ bony structures with high accuracy. A study was undertaken to determine the morphology, and its variations, of the mandibular condyle and glenoid fossa among Malay and Chinese Malaysians.

    METHODS: CBCT was used to assess 200 joints in 100 subjects (mean age, 30.5 years). i-CAT CBCT software and The Mimics 16.0 software were employed to measure the volume, metrical size, position of each condyle sample and the thickness of the roof of the glenoid fossa (RGF).

    RESULTS: No significant gender differences were noted in thickness of the RGF and condylar length; however condylar volume, width, height and the joint spaces were significantly greater among males. With regards to comparison of both TMJs, the means of condylar volume, width and length of the right TMJ were significantly higher, while the means of the left condylar height and thickness of RGF were higher. When comparing the condylar measurements and the thickness of RGF between the two ethnic groups, we found no significant difference for all measurements with exception of condylar height, which is higher among Chinese.

    CONCLUSION: The similarity in measurements for Malays and Chinese may be due to their common origin. This information can be clinically useful in establishing the diagnostic criteria for condylar volume, metrical size, and position in the Malaysian East Asians population.

    Matched MeSH terms: Cone-Beam Computed Tomography/methods*
  19. Martin CJ, Kron T, Vassileva J, Wood TJ, Joyce C, Ung NM, et al.
    Phys Med, 2021 Oct;90:53-65.
    PMID: 34562809 DOI: 10.1016/j.ejmp.2021.09.004
    Improvements in delivery of radiation dose to target tissues in radiotherapy have increased the need for better image quality and led to a higher frequency of imaging patients. Imaging for treatment planning extends to function and motion assessment and devices are incorporated into medical linear accelerators (linacs) so that regions of tissue can be imaged at time of treatment delivery to ensure dose distributions are delivered as accurately as possible. A survey of imaging in 97 radiotherapy centres in nine countries on six continents has been undertaken with an on-line questionnaire administered through the International Commission on Radiological Protection mentorship programme to provide a snapshot of imaging practices. Responses show that all centres use CT for planning treatments and many utilise additional information from magnetic resonance imaging and positron emission tomography scans. Most centres have kV cone beam CT attached to at least some linacs and use this for the majority of treatment fractions. The imaging options available declined with the human development index (HDI) of the country, and the frequency of imaging during treatment depended more on country than treatment site with countries having lower HDIs imaging less frequently. The country with the lowest HDI had few kV imaging facilities and relied on MV planar imaging intermittently during treatment. Imaging protocols supplied by vendors are used in most centres and under half adapt exposure conditions to individual patients. Recording of patient doses, a knowledge of which is important in optimisation of imaging protocols, was limited primarily to European countries.
    Matched MeSH terms: Cone-Beam Computed Tomography
  20. Kamaruddin N, Daud F, Yusof A, Aziz ME, Rajion ZA
    PeerJ, 2019;7:e6319.
    PMID: 30697493 DOI: 10.7717/peerj.6319
    Background: Visualization and calculation of the airway dimensions are important because an increase of airway resistance may lead to life-threatening emergencies. The visualization and calculation of the airway are possible using radiography technique with their advance software. The aim of this study was to compare and to test the reliability of the measurement of the upper airway volume and minimum area using airway analysis function in two software.

    Methods: The sample consisted of 11 cone-beam computed tomography (CBCT) scans data, evaluated using the Invivo5 (Anatomage) and Romexis (version 3.8.2.R, Planmeca) software which afford image reconstruction, and airway analysis. The measurements were done twice with one week gap between the two measurements. The measurement obtained was analyzed with t-tests and intraclass correlation coefficient (ICC), with confidence intervals (CI) was set at 95%.

    Results: From the analysis, the mean reading of volume and minimum area is not significantly different between Invivo5 and Romexis. Excellent intrarater reliability values were found for the both measurement on both software, with ICC values ranging from 0.940 to 0.998.

    Discussion: The results suggested that both software can be used in further studies to investigate upper airway, thereby contributing to the diagnosis of upper airway obstructions.

    Matched MeSH terms: Cone-Beam Computed Tomography
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links