Displaying publications 1 - 20 of 76 in total

Abstract:
Sort:
  1. Abdulhadi LM
    Chin J Dent Res, 2010;13(1):61-6.
    PMID: 20936194
    A 70-year-old man who suffered from extensive extra and intraoral defects was rehabilitated with a prosthesis using multiple retaining means. The treatment was performed in two parts: externally involving the construction of an episthesis supported only by the remaining intact boundaries of the defect and retained by mini-dental implants and spectacle frame with a modified ear hook; and intraorally by an acrylic resin obturator to restore the function of the hemi-sectioned hard and soft palate. The episthesis was securely retained with minimal movement and/or dislodgment of the prosthesis during function. Multiple retentive techniques may be used to fix heavy external prostheses as an alternative to conventional implants or biological adhesives.
    Matched MeSH terms: Dental Implants
  2. Kher U, Patil PG, Tunkiwala A, Advani P
    J Prosthet Dent, 2020 08;124(2):248-249.
    PMID: 31810615 DOI: 10.1016/j.prosdent.2019.09.020
    Matched MeSH terms: Dental Implants*; Dental Implants, Single-Tooth*
  3. Al-Juboori MJ
    PMID: 25678816 DOI: 10.2147/CCIDE.S76637
    The displacement of a dental implant into the maxillary sinus may lead to implant failure due to exposure of the apical third or the tip of the implant beyond the bone, resulting in soft tissue growth. This case report discusses dental implant placement in the upper first molar area with maxillary sinus involvement of approximately 2 mm. A new technique for progressive implant loading was used, involving immediately loaded implants with maxillary sinus perforation and low primary stability. Follow-up was performed with resonance frequency analysis and compared with an implant placed adjacent in the upper second premolar area using a conventional delayed loading protocol. Implants with maxillary sinus involvement showed increasing stability during the healing period. We found that progressive implant loading may be a safe technique for the placement of immediately loaded implants with maxillary sinus involvement.
    Matched MeSH terms: Dental Implants
  4. Rahman SA, Muhammad H, Haque S, Alam MK
    J Contemp Dent Pract, 2019 Feb 01;20(2):173-178.
    PMID: 31058631
    AIM: The aim of this study was to evaluate the changes in the peri-implant hard and soft tissues and implant stability and to assess the correlation of bone loss and peri-implant probing depth with implant stability.

    MATERIALS AND METHODS: Twenty-one patients with implants were included in this study and implants were assessed by resonance frequency analysis (RFA). Bone levels of the implants were assessed by measuring mesial and distal bone levels from the periapical radiograph, and soft tissue was assessed from probing depth using a periodontal probe. Implants were assessed for stability and probing depth at pre-loading, at 3 months and 6 months post-loading. RFA and probing depth were statistically compared from different time points. Correlation of probing depth and marginal bone loss with implant stability was also determined.

    RESULTS: The average change in implant stability quotient (ISQ) measurements from pre-loading to 6 months post-loading was found to be statistically significant (p <0.005). The average probing depth reduced from 1.767 mm at pre-loading to 1.671 mm at post-loading 3 months, and 1.600 mm at post-loading 6 months. At 6 months of function, radiographic examination yielded 0.786 mm mesial bone loss and 0.8 mm distal bone loss. It was found to be statistically significant (p <0.005) but within an acceptable range. No significant correlation was found between implant stability and bone loss; and implant stability and probing depth.

    CONCLUSION: The study revealed an increasing trend in implant stability values with the time that indicates successful osseointegration. Increasing mean values for mesial and distal bone loss were also found.

    CLINICAL SIGNIFICANCE: The success of dental implants is highly dependent on the quality of bone and implant-bone interface, i.e., osseointegration. The most important factors that influence the survival rate of an implant is initial stability. The present study found the changes in the peri-implant hard and soft tissues and implant stability. This article, while being a prospective study, may show the evidence of successful osseointegration by increasing trend in implant stability (RFA) values with time which can help to the clinician in the long-term management of implants.

    Matched MeSH terms: Dental Implantation, Endosseous; Dental Implants*
  5. Sghaireen MG, Alduraywish AA, Srivastava KC, Shrivastava D, Patil SR, Al Habib S, et al.
    PMID: 32708165 DOI: 10.3390/ijerph17145253
    Diabetes mellitus is known to compromise the various aspects of homeostasis, including the immune response and the composition of oral microflora. One of the oral manifestations of diabetes mellitus is tooth loss and the survival rate of dental implants chosen as a treatment modality for its rehabilitation is controversial. The current study aims to evaluate and compare the failure rate of dental implants between well-controlled diabetic and healthy patients. A retrospective study of case-control design was conceptualized with 121 well-controlled diabetic and 136 healthy individuals. Records of subjects who had undergone oral rehabilitation with dental implants between the periods of January 2013 to January 2016 were retrieved. Post-operative evaluation was carried out for all patients for about three years to assess the immediate and long-term success of the procedure. From a total of 742 dental implants, 377 were placed in well-controlled diabetic patients (case group) and 365 in healthy subjects (control group). A comparable (9.81%), but non-significant (p = 0.422) failure rate was found in the case group in comparison to the control group (9.04%). A non-significant (p = 0.392) raised number (4.98%) of failure cases were reported among females in comparison to males (4.44%). In respect to arch, the mandibular posterior region was reported as the highest failure cases (3.09%; p = 0.411), with 2.29% of cases reported in the mandibular anterior (p = 0.430) and maxillary posterior (p = 0.983) each. The maxillary anterior region was found to have the least number (1.75%; p = 0.999) of failure cases. More (4.98%; p = 0.361) cases were reported to fail during the functional loading stage in contrast to osseointegration (4.44%; p = 0.365). A well-controlled diabetic status does not impose any additional risk for individuals undergoing dental implant therapy.
    Matched MeSH terms: Dental Implants
  6. Farook TH, Jamayet NB, Abdullah JY, Rajion ZA, Alam MK
    J Stomatol Oral Maxillofac Surg, 2020 Jun;121(3):268-277.
    PMID: 31610244 DOI: 10.1016/j.jormas.2019.10.003
    A systematic review was conducted in early 2019 to evaluate the articles published that dealt with digital workflow, CAD, rapid prototyping and digital image processing in the rehabilitation by maxillofacial prosthetics. The objective of the review was to primarily identify the recorded cases of orofacial rehabilitation made by maxillofacial prosthetics using computer assisted 3D printing. Secondary objectives were to analyze the methods of data acquisition recorded with challenges and limitations documented with various software in the workflow. Articles were searched from Scopus, PubMed and Google Scholar based on the predetermined eligibility criteria. Thirty-nine selected papers from 1992 to 2019 were then read and categorized according to type of prosthesis described in the papers. For nasal prostheses, Common Methods of data acquisition mentioned were computed tomography, photogrammetry and laser scanners. After image processing, computer aided design (CAD) was used to design and merge the prosthesis to the peripheral healthy tissue. Designing and printing the mold was more preferred. Moisture and muscle movement affected the overall fit especially for prostheses directly designed and printed. For auricular prostheses, laser scanning was most preferred. For unilateral defects, CAD was used to mirror the healthy tissue over to the defect side. Authors emphasized on the need of digital library for prostheses selection, especially for bilateral defects. Printing the mold and conventionally creating the prosthesis was most preferred due to issues of proper fit and color matching. Orbital prostheses follow a similar workflow as auricular prosthesis. 3D photogrammetry and laser scans were more preferred and directly printing the prosthesis was favored in various instance. However, ocular prostheses fabrication was recorded to be a challenge due to difficulties in appropriate volume reconstruction and inability to mirror healthy globe. Only successful cases of digitally designed and printed iris were noted.
    Matched MeSH terms: Dental Implants*
  7. Chai WL, Moharamzadeh K, van Noort R, Emanuelsson L, Palmquist A, Brook IM
    J Periodontal Res, 2013 Oct;48(5):663-70.
    PMID: 23442017 DOI: 10.1111/jre.12062
    Studies of peri-implant soft tissue on in vivo models are commonly based on histological sections prepared using undecalcified or 'fracture' techniques. These techniques require the cutting or removal of implant during the specimen preparation process. The aim of this study is to explore a new impression technique that does not require any cutting or removal of implant for contour analysis of soft tissue around four types of titanium (Ti) surface roughness using an in vitro three-dimensional oral mucosal model (3D OMM).
    Matched MeSH terms: Dental Implants*
  8. Sivakumar I, Arunachalam S, Choudhary S, Buzayan MM
    J Prosthet Dent, 2021 Jun;125(6):862-869.
    PMID: 32694022 DOI: 10.1016/j.prosdent.2020.04.001
    STATEMENT OF PROBLEM: Immunosuppression and coinfections associated with human immunodeficiency virus (HIV) infection pose a relative contraindication for dental implant therapy. However, although implants have been placed in patients with HIV with reasonable success, how HIV infection affects their survival is unclear.

    PURPOSE: The purpose of this systematic review of the literature and meta-analysis was to analyze the data on the survival of dental implants in patients with HIV.

    MATERIAL AND METHODS: A search for relevant articles published up to November 2019 was performed in PubMed/Medline and Cochrane databases, Clinicaltrials.gov, and Google Scholar. Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were adopted for the conduct of the systematic review. The most pertinent data were extracted and pooled for qualitative and quantitative analyses with 95% confidence intervals. Heterogeneity was analyzed by using I-squared statistics.

    RESULTS: A total of 8 studies involving 411 individuals with HIV and 1109 implants were included in the meta-analysis. The mean follow-up period was 2.8 years. A pooled estimate of 95% of implant survival rate with 95% confidence interval(92% to 96%) was noted. Heterogeneity across the 8 studies was found to be 41% with moderate true variability.

    CONCLUSIONS: This systematic review demonstrated that HIV infection does not pose a serious threat to implant survival on short-term evaluation, but the evidence is of low quality.

    Matched MeSH terms: Dental Implantation, Endosseous; Dental Implants*
  9. Chai, W.L.
    Ann Dent, 2009;16(1):24-30.
    MyJurnal
    This systematic review focuses on the management of two types of osseous defects, i.e. dehiscence and fenestration that arise during the placement of dental implant in the edentulous area (delayed implant placement). A systematic online search of main database from 1975 to 2009 was made. Five randomised controlled trials have been identified based on the inclusion criteria. Different management procedures were identified, in which guided bone regeneration procedure was most commonly advocated. Resorbable and non-resorbable m'embranes were compared, in which resorbable membrane was preferred as it caused less complicatiQn of membrane exposure or risk of infection. The benefit of using bone substitute along with membrane in rypairing bony defects cannot be concluded.
    Matched MeSH terms: Dental Implants
  10. Kassim ZH, Nor Hisham ND, Dardiri NA, Goot Heah K, Hazwani Baharuddin I, De Angelis N
    Minerva Stomatol, 2019 Dec;68(6):291-296.
    PMID: 32052617 DOI: 10.23736/S0026-4970.19.04242-0
    BACKGROUND: The aims of this study were to enumerate the primary implant stability quotient (ISQ) value of self-tapping dual etched implants and to explore the influence of parameters such as implant length, implant diameter, age, gender, implant location and osteotomy preparation on the ISQ value.

    METHODS: Retrospective data from clinical worksheets given to participants during two implant courses held between the periods of 2013 to 2014 were evaluated. A total of 61 implants were considered based on the inclusion criteria. The effects of parameters such as implant diameter, implant length, age, gender, implant location and osteotomy protocol on ISQ values were analyzed.

    RESULTS: Mean ISQ value for all implants was 67.21±9.13. Age of patients (P=0.016) and location of implants (P=0.041) had a significant linear relationship with the ISQ values. Within the age limit of the patients in this study, it was found that an increase in one year of patient's age results in 0.20 decrease in ISQ value (95% CI: -0.36, -0.04). However, placing an implant in the posterior maxilla may negatively affect the ISQ with a likely decrease in primary stability by 6.76 ISQ value (95% CI: -13.22, -0.30).

    CONCLUSIONS: The results suggest that the mean ISQ achieved by the participants were comparable with the range reported for this particular type of implants. The patient's age and location of implants were elucidated as the determinant factors of primary implant stability.

    Matched MeSH terms: Dental Implantation, Endosseous*; Dental Implants*
  11. Nurul Ain Mohamed Yusof, Mohd Salman Masri, Erni Noor
    Compendium of Oral Science, 2018;5(1):46-53.
    MyJurnal
    Introduction: High survival rates of dental implants were commonly reported even after 10 years of follow up. Nevertheless, complications and failure may occur and the implant would need to be removed. In recent years, the use of autogenous blood products in dental surgery has increased due to its ability to aid the healing of the soft and hard tissues. Clinical case: The case demonstrated the utilisation of concentrated growth factor (CGF) from the patient’s blood for healing following conservative removal of a failed dental implant. Subsequently, the patient showed satisfactory recovery without any infections and clinical complaints. Conclusion: This explantation procedure, together with the use of CGF, may prevent the normal bone resorption and accelerate soft tissue healing. As it is biological in nature having originated from the patient’s blood, it is more readily accepted by the tissues and the risk of infection is low.
    Matched MeSH terms: Dental Implants
  12. Ling BC, Gillings BR
    Asian J Aesthet Dent, 1995;3:17-21.
    PMID: 9063105
    With the prognosis of dental implant replacement of missing teeth becoming better each year, practitioners are focusing their attention on the aesthetic aspects of implantology. However, improvement in aesthetics is only possible with the improvement in implant technology, surgical techniques and prosthodontic procedures. This study aimed at evaluating the effects of various physical and chemical agents on the implant surface; with the view of obtaining increased surface area and biocompatibility. The study found that the treatment of air-aluminum oxide blasted implants using a mixture of 30% HNO3-5% HF acids produced a surface which meets the consideration of aesthetics for implants placed in the anterior maxillary region.
    Matched MeSH terms: Dental Implants*
  13. Baig MR, Gunaseelan R
    J Oral Implantol, 2012 Apr;38(2):149-53.
    PMID: 20932151 DOI: 10.1563/AAID-JOI-D-09-00089
    Passive fit of a long-span screw-retained implant prosthesis is an important criteria for the success of the restoration. This article describes a technique for fabricating a ceramometal implant fixed dental prosthesis (FDP) for a long-span partially edentulous situation by altering the conventional screw-retained design. The possibility of a passive fit is maximized by intraoral luting of the cast frame to milled abutments, and the potential framework distortion during fabrication is compensated to a major extent. Retrievability is ensured by screw retention of the prosthesis to the implants. Compared with conventional porcelain fused to metal screw-retained FDP, this prosthesis is relatively inexpensive to fabricate.
    Matched MeSH terms: Dental Implantation, Endosseous; Dental Implants*; Dental Implant-Abutment Design
  14. Garg R, Mishra N, Alexander M, Gupta SK
    Ann Maxillofac Surg, 2017 Jul-Dec;7(2):237-244.
    PMID: 29264292 DOI: 10.4103/ams.ams_87_17
    Introduction: With introduction of the term "ossteointegration of dental implant" by Branemark, advancement in implantology from 1957 to 2017 has come a long way with modification in implant type and in loading time. This study aims to evaluate the survival of endo-osseous immediate loading (IL) implant and basal IL implants in atrophic jaws with objective to compare implant survival in atrophic jaws for full mouth rehabilitation between endo-osseous IL versus endo-osseous delayed loading (DL) versus basal IL during 3-year follow-up.

    Materials and Methods: Fifty-two (34 endo-osseous and 18 basal) implants were placed in 4 patients requiring full mouth rehabilitation in atrophic jaws. Case 1: Endo-osseous DL implants in upper and lower arch, Case 2: Endo-osseous IL implants in upper and lower arch, Case 3: Basal IL implant in upper and lower arch, and Case 4: Endo-osseous DL in upper arch and basal IL implant in the lower arch. Intraoperative evaluation was done on the basis of pain (visual analog scale [VAS]), operative time, and initial primary implant stability. Postoperative evaluation was done on pain (VAS), infection, radiographically successful implant (orthopantomogram), and patient satisfaction (Grade 0-10).

    Results: All cases showed satisfactory results but more amount of intra- and post-operative pain was felt with immediate basal implants.

    Conclusion: We believe that clinicians should comply with patient requests, and for this reason, we agree with some authors to use minimally invasive techniques and to avoid when possible esthetic or functional problems associated with the use of removable prosthesis after teeth extractions.
    Matched MeSH terms: Dental Implants
  15. Yunus N, Abdullah H, Hanapiah F
    J Prosthet Dent, 2001 Jun;85(6):540-3.
    PMID: 11404753
    This article describes the occlusal rehabilitation of a partially edentulous patient who did not want a removable partial denture. Implants and extensive fixed restorations were used to restore posterior support and treat severely worn dentition, respectively. The treatment offered the patient a functional and esthetic result.
    Matched MeSH terms: Dental Implantation, Endosseous; Dental Implants*
  16. Al-Juboori MJ, AbdulRahaman SB, Hassan A
    Implant Dent, 2013 Aug;22(4):351-5.
    PMID: 23811720 DOI: 10.1097/ID.0b013e318296583d
    To detect the correlation between crestal bone resorption and implant stability during healing period using resonance frequency analysis (RFA).
    Matched MeSH terms: Dental Implantation, Endosseous/methods; Dental Implants*
  17. Hassan MH
    Med J Malaysia, 2004 May;59 Suppl B:164-5.
    PMID: 15468869
    There has been, and is still, concern about the high elastic modulus of Ti alloys compared to bone. Any reduction in the Young's modulus value of the implant is expected to enhance stress redistribution to the adjacent bone tissues, minimize stress shielding and eventually prolong device lifetime. Dynamic Monte Carlo simulation is used to predict the gradual reduction in Young's modulus values between the bulk of Ti alloys and the modified surface layers due to Ca ion implantation. The simulation can be used as a screening step when applying new alloys and/or coatings.
    Matched MeSH terms: Dental Implants*
  18. Isa, Z.M., Hobkirk, J.A.
    Ann Dent, 2000;7(1):-.
    MyJurnal
    Currently many dental implant systems with varied and numerous components are available commercially, and with new implant systems and designs emerging, it is essential that the user understands that any system selected should be based on sound scientific principles and capable of osseoil!tegration. This has been defined in many different ways, with biomaterial, biological and biomechanical factors being the main considerations. The final restoration is based on both biological tissue and mechanical components. As the success of osseointegration is based on the clinical outcome, clinicians must ensure that the stresses that the superstructure, implant, and surrounding bone are subjected to are within the tolerable limits of the various components, even though the degree of tolerance has not yet been fully defined.
    Matched MeSH terms: Dental Implants
  19. Wahab NFAC, Kannan TP, Mahmood Z, Rahman IA, Ismail H
    Toxicol In Vitro, 2018 Mar;47:207-212.
    PMID: 29247761 DOI: 10.1016/j.tiv.2017.12.002
    Biphasic Calcium Phosphate (BCP) with a ratio of 20/80 Hydroxyapatite (HA)/Beta-tricalcium phosphate (β-TCP) promotes the differentiation of human dental pulp cells (HDPCs). In the current study, the genotoxicity of locally produced BCP of modified porosity (65%) with a mean pore size of 300micrometer (μm) was assessed using Comet and Ames assays. HDPCs were treated with BCP extract at three different inhibitory concentrations which were obtained based on cytotoxicity test conducted with concurrent negative and positive controls. The tail moment of HDPCs treated with BCP extract at all three concentrations showed no significant difference compared to negative control (p>0.05), indicating that BCP did not induce DNA damage to HDPCs. The BCP was evaluated using five tester strains of Salmonella typhimurium TA98, TA100, TA102, TA1537 and TA1538. Each strain was incubated with BCP extract with five different concentrations in the presence and absence of metabolic activation system (S9) mix. Concurrently, negative and positive controls were included. The average number of revertant colonies per plate treated with the BCP extract was less than double as compared to the number of revertant colonies in negative control plate and no dose-related increase was observed. Results from both assays suggested that the BCP of modified porosity did not exhibit any genotoxic effect under the present test conditions.
    Matched MeSH terms: Dental Implants/adverse effects*
  20. Farook TH, Barman A, Abdullah JY, Jamayet NB
    J Prosthodont, 2021 Jun;30(5):420-429.
    PMID: 33200429 DOI: 10.1111/jopr.13286
    PURPOSE: Mesh optimization reduces the texture quality of 3D models in order to reduce storage file size and computational load on a personal computer. This study aims to explore mesh optimization using open source (free) software in the context of prosthodontic application.

    MATERIALS AND METHODS: An auricular prosthesis, a complete denture, and anterior and posterior crowns were constructed using conventional methods and laser scanned to create computerized 3D meshes. The meshes were optimized independently by four computer-aided design software (Meshmixer, Meshlab, Blender, and SculptGL) to 100%, 90%, 75%, 50%, and 25% levels of original file size. Upon optimization, the following parameters were virtually evaluated and compared; mesh vertices, file size, mesh surface area (SA), mesh volume (V), interpoint discrepancies (geometric similarity based on virtual point overlapping), and spatial similarity (volumetric similarity based on shape overlapping). The influence of software and optimization on surface area and volume of each prosthesis was evaluated independently using multiple linear regression.

    RESULTS: There were clear observable differences in vertices, file size, surface area, and volume. The choice of software significantly influenced the overall virtual parameters of auricular prosthesis [SA: F(4,15) = 12.93, R2 = 0.67, p < 0.001. V: F(4,15) = 9.33, R2 = 0.64, p < 0.001] and complete denture [SA: F(4,15) = 10.81, R2 = 0.67, p < 0.001. V: F(4,15) = 3.50, R2 = 0.34, p = 0.030] across optimization levels. Interpoint discrepancies were however limited to <0.1mm and volumetric similarity was >97%.

    CONCLUSION: Open-source mesh optimization of smaller dental prostheses in this study produced minimal loss of geometric and volumetric details. SculptGL models were most influenced by the amount of optimization performed.

    Matched MeSH terms: Dental Implants*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links