With the prognosis of dental implant replacement of missing teeth becoming better each year, practitioners are focusing their attention on the aesthetic aspects of implantology. However, improvement in aesthetics is only possible with the improvement in implant technology, surgical techniques and prosthodontic procedures. This study aimed at evaluating the effects of various physical and chemical agents on the implant surface; with the view of obtaining increased surface area and biocompatibility. The study found that the treatment of air-aluminum oxide blasted implants using a mixture of 30% HNO3-5% HF acids produced a surface which meets the consideration of aesthetics for implants placed in the anterior maxillary region.
Endoseous Implant insertion for the replacement of missing teeth is the state of the art at present times. An understanding of the biology of the perimplant tissues is imperative for the overall success in the dental rehabilitation of a patient with fixture supported prosthesis. The dental implant tissue interface comprises bone, both cortical and cancellous bone; supracrestal connective tissue and the epithelial attachment. A comprehensive review of the response of bone during the postoperative or healing phase, the loading or remodelling phase and during the steady phase is described.
Tissue-integrated oral implants have opened-up a new perspective in oral rehabilitation of tumour patients who had undergone surgery. The present case demonstrated a simple approach to rehabilitate a patient who had subtotal maxillectomy using dental implant. The use of an implant in combination with a natural abutment tooth was shown to improve the retention and stability of the obturator. Magnetic attachment and telescopic restoration were the retainers of choice and they provided good aesthetic result.
Currently many dental implant systems with varied and numerous components are available commercially, and with new implant systems and designs emerging, it is essential that the user understands that any system selected should be based on sound scientific principles and capable of osseoil!tegration. This has been defined in many different ways, with biomaterial, biological and biomechanical factors being the main considerations. The final restoration is based on both biological tissue and mechanical components. As the success of osseointegration is based on the clinical outcome, clinicians must ensure that the stresses that the superstructure, implant, and surrounding bone are subjected to are within the tolerable limits of the various components, even though the degree of tolerance has not yet been fully defined.
The CO2 laser has been actively used clinically for soft tissue surgery. The advantages have been widely acknowledged. In implant related tissue surgery, the use .6f CO2 laser has been debated on whether the heat generated during the procedure would be detrimental to the bone thus losing the implants through disosseointegration. In this preliminary work, CO2 laser was used to perform a simulated gingivectomy of tissue surrounding plasma coated titanium implants. The purpose was to observe the pattern of heat generated at different levels of the implant body. The safe power range and standard precaution was also identified. The results suggested that power output between 6 Watt to 8 Watt in repeated pulsed mode with duration of 5 seconds is considered safe. With this mode the operator
This article describes the occlusal rehabilitation of a partially edentulous patient who did not want a removable partial denture. Implants and extensive fixed restorations were used to restore posterior support and treat severely worn dentition, respectively. The treatment offered the patient a functional and esthetic result.
Today, one critical goal in implant placement is the achievement of optimal soft tissue integration. Reports thus far have demonstrated successful soft tissue preservation in delayed loaded implants placed in anterior jaws. The aim of this study was to histomorphometrically examine the soft tissues around immediately loaded implants placed in the macaque posterior mandible.
There has been, and is still, concern about the high elastic modulus of Ti alloys compared to bone. Any reduction in the Young's modulus value of the implant is expected to enhance stress redistribution to the adjacent bone tissues, minimize stress shielding and eventually prolong device lifetime. Dynamic Monte Carlo simulation is used to predict the gradual reduction in Young's modulus values between the bulk of Ti alloys and the modified surface layers due to Ca ion implantation. The simulation can be used as a screening step when applying new alloys and/or coatings.
This article describes the rehabilitation of a completely edentulous patient using a milled titanium implant framework and cemented crowns. This combined approach significantly offsets unsuitable implant position, alignment, or angulation, while ensuring the easy retrievability, repair, and maintenance of the prosthesis. Hence, the dual advantage of cemented-retained crowns reproducing appropriate esthetics and function, irrespective of where the screw access openings are located in the substructure, can be obtained, along with the splinting effect and management of soft and hard tissue deficits achievable with a screw-retained framework.
The purpose of this study was to compare bone healing and coronal bone remodeling following both immediate and delayed placement of titanium dental implants in extraction sockets.
This systematic review focuses on the management of two types of osseous defects, i.e. dehiscence and fenestration that arise during the placement of dental implant in the edentulous area (delayed implant placement). A systematic online search of main database from 1975 to 2009 was made. Five randomised controlled trials have been identified based on the inclusion criteria. Different management procedures were identified, in which guided bone regeneration procedure was most commonly advocated. Resorbable and non-resorbable m'embranes were compared, in which resorbable membrane was preferred as it caused less complicatiQn of membrane exposure or risk of infection. The benefit of using bone substitute along with membrane in rypairing bony defects cannot be concluded.
In dental implant treatment, the long-term prognosis is dependent on the biologic seal formed by the soft tissue around the implant. The in vitro investigation of the implant-soft tissue interface is usually carried out using a monolayer cell-culture model that lacks a polarized-cell phenotype. This study developed a tissue-engineered three-dimensional oral mucosal model (3D OMM) to investigate the implant-soft tissue interface.
Abstract This article describes the clinical and laboratory procedures involved in the fabrication of laboratory-processed, provisional, screw-retained, implant-supported maxillary and mandibular fixed complete dentures incorporating a cast metal reinforcement for immediate loading of implants. Precise fit is achieved by intraoral luting of the cast frame to milled abutments. Effective splinting of all implants is attained by the metal substructure and retrievability is provided by the screw-retention of the prosthesis.
Treatment of patients with aggressive periodontitis has always been a challenge to the clinician. Both young and old are known to be affected by this progressive destructive condition of the supporting dental structures. Although dental implants have been offered as a viable treatment alternative for such patients, additional procedures (like bone grafting) and delayed protocols have limited their usage. This case report describes the treatment of a young patient with aggressive periodontitis using a graftless implant solution. Zygoma implants in conjunction with conventional implants were used with immediate loading.
A 70-year-old man who suffered from extensive extra and intraoral defects was rehabilitated with a prosthesis using multiple retaining means. The treatment was performed in two parts: externally involving the construction of an episthesis supported only by the remaining intact boundaries of the defect and retained by mini-dental implants and spectacle frame with a modified ear hook; and intraorally by an acrylic resin obturator to restore the function of the hemi-sectioned hard and soft palate. The episthesis was securely retained with minimal movement and/or dislodgment of the prosthesis during function. Multiple retentive techniques may be used to fix heavy external prostheses as an alternative to conventional implants or biological adhesives.
The success of dental implant treatment depends on the healing of both hard and soft tissues. While osseointegration provides initial success, the biological seal of the peri-implant soft tissue is crucial for maintaining the long term success of implants. Most studies of the biological seal of peri-implant tissues are based on animal or monolayer cell culture models. To understand the mechanisms of soft tissue attachment and the factors affecting the integrity of the soft tissue around the implants, it is essential to obtain good quality histological sections for microscopic examination. The nature of the specimens, however, which consist of both metal implant and soft peri-implant tissues, poses difficulties in preparing the specimens for histomorphometric analysis of the implant-soft tissue interface. We review various methods that have been used for the implant-tissue interface investigation with particular focus on the soft tissue. The different methods are classified and the advantages and limitations of the different techniques are highlighted.
A three dimensional tissue-engineered human oral mucosal model (3D OMM) used in the investigation of implant-soft tissue interface was recently reported. The aim of this study was to examine the ultrastructural features of soft tissue attachment to various titanium (Ti) implant surfaces based on the 3D OMM. Two techniques, that is, focus ion beam (FIB) and electropolishing techniques were used to prepare specimens for transmission electron microscopic (TEM) analysis of the interface. The 3D OM consisting of both epithelial and connective tissue layers was constructed by co-culturing human oral keratinocytes and fibroblasts onto an acellular dermis scaffold. Four types of Ti surface topographies were tested: polished, machined (turned), sandblasted, and TiUnite. The specimens were then processed for TEM examination using FIB (Ti remained) and electropolishing (Ti removed) techniques. The FIB sections showed some artifact and lack of details of ultrastructural features. In contrast, the ultrathin sections prepared from the electropolishing technique showed a residual Ti oxide layer, which preserved the details for intact ultrastructural interface analysis. There was evidence of hemidesmosome-like structures at the interface on the four types of Ti surfaces, which suggests that the tissue-engineered oral mucosa formed epithelial attachments on the Ti surfaces.
A stable oral mucosa is crucial for long-term survival and biofunctionality of implants. Most of this evidence is derived from clinical and animal studies based solely on implant-supported prosthesis. Much less is known about the dimensions and relationships of this soft tissue complex investing tooth-implant-supported bridgework (TISB). The aim here was to obtain experimental evidence on the dimensional characteristics of oral mucosa around TISB with two different abutment designs.
Passive fit of a long-span screw-retained implant prosthesis is an important criteria for the success of the restoration. This article describes a technique for fabricating a ceramometal implant fixed dental prosthesis (FDP) for a long-span partially edentulous situation by altering the conventional screw-retained design. The possibility of a passive fit is maximized by intraoral luting of the cast frame to milled abutments, and the potential framework distortion during fabrication is compensated to a major extent. Retrievability is ensured by screw retention of the prosthesis to the implants. Compared with conventional porcelain fused to metal screw-retained FDP, this prosthesis is relatively inexpensive to fabricate.