Displaying publications 1 - 20 of 76 in total

Abstract:
Sort:
  1. Chai, W.L.
    Ann Dent, 2009;16(1):24-30.
    MyJurnal
    This systematic review focuses on the management of two types of osseous defects, i.e. dehiscence and fenestration that arise during the placement of dental implant in the edentulous area (delayed implant placement). A systematic online search of main database from 1975 to 2009 was made. Five randomised controlled trials have been identified based on the inclusion criteria. Different management procedures were identified, in which guided bone regeneration procedure was most commonly advocated. Resorbable and non-resorbable m'embranes were compared, in which resorbable membrane was preferred as it caused less complicatiQn of membrane exposure or risk of infection. The benefit of using bone substitute along with membrane in rypairing bony defects cannot be concluded.
    Matched MeSH terms: Dental Implants
  2. Chai WL, Moharamzadeh K, Brook IM, Van Noort R
    Biotech Histochem, 2011 Aug;86(4):242-54.
    PMID: 20392135 DOI: 10.3109/10520291003707916
    The success of dental implant treatment depends on the healing of both hard and soft tissues. While osseointegration provides initial success, the biological seal of the peri-implant soft tissue is crucial for maintaining the long term success of implants. Most studies of the biological seal of peri-implant tissues are based on animal or monolayer cell culture models. To understand the mechanisms of soft tissue attachment and the factors affecting the integrity of the soft tissue around the implants, it is essential to obtain good quality histological sections for microscopic examination. The nature of the specimens, however, which consist of both metal implant and soft peri-implant tissues, poses difficulties in preparing the specimens for histomorphometric analysis of the implant-soft tissue interface. We review various methods that have been used for the implant-tissue interface investigation with particular focus on the soft tissue. The different methods are classified and the advantages and limitations of the different techniques are highlighted.
    Matched MeSH terms: Dental Implants/adverse effects*
  3. Farook TH, Jamayet NB, Abdullah JY, Rajion ZA, Alam MK
    J Stomatol Oral Maxillofac Surg, 2020 Jun;121(3):268-277.
    PMID: 31610244 DOI: 10.1016/j.jormas.2019.10.003
    A systematic review was conducted in early 2019 to evaluate the articles published that dealt with digital workflow, CAD, rapid prototyping and digital image processing in the rehabilitation by maxillofacial prosthetics. The objective of the review was to primarily identify the recorded cases of orofacial rehabilitation made by maxillofacial prosthetics using computer assisted 3D printing. Secondary objectives were to analyze the methods of data acquisition recorded with challenges and limitations documented with various software in the workflow. Articles were searched from Scopus, PubMed and Google Scholar based on the predetermined eligibility criteria. Thirty-nine selected papers from 1992 to 2019 were then read and categorized according to type of prosthesis described in the papers. For nasal prostheses, Common Methods of data acquisition mentioned were computed tomography, photogrammetry and laser scanners. After image processing, computer aided design (CAD) was used to design and merge the prosthesis to the peripheral healthy tissue. Designing and printing the mold was more preferred. Moisture and muscle movement affected the overall fit especially for prostheses directly designed and printed. For auricular prostheses, laser scanning was most preferred. For unilateral defects, CAD was used to mirror the healthy tissue over to the defect side. Authors emphasized on the need of digital library for prostheses selection, especially for bilateral defects. Printing the mold and conventionally creating the prosthesis was most preferred due to issues of proper fit and color matching. Orbital prostheses follow a similar workflow as auricular prosthesis. 3D photogrammetry and laser scans were more preferred and directly printing the prosthesis was favored in various instance. However, ocular prostheses fabrication was recorded to be a challenge due to difficulties in appropriate volume reconstruction and inability to mirror healthy globe. Only successful cases of digitally designed and printed iris were noted.
    Matched MeSH terms: Dental Implants*
  4. Kher U, Patil PG, Tunkiwala A, Advani P
    J Prosthet Dent, 2020 08;124(2):248-249.
    PMID: 31810615 DOI: 10.1016/j.prosdent.2019.09.020
    Matched MeSH terms: Dental Implants*; Dental Implants, Single-Tooth*
  5. Baig MR, Buzayan MM, Yunus N
    J Investig Clin Dent, 2018 May;9(2):e12320.
    PMID: 29349910 DOI: 10.1111/jicd.12320
    AIM: The aim of the present study was to assess the accuracy of multi-unit dental implant casts obtained from two elastomeric impression materials, vinyl polyether silicone (VPES) and polyether (PE), and to test the effect of splinting of impression copings on the accuracy of implant casts.

    METHODS: Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05.

    RESULTS: The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05).

    CONCLUSIONS: The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions.

    Matched MeSH terms: Dental Implants*
  6. Khalid T, Yunus N, Ibrahim N, Saleh NBM, Goode D, Masood M
    J Prosthet Dent, 2020 Dec;124(6):674-681.
    PMID: 31952858 DOI: 10.1016/j.prosdent.2019.08.005
    STATEMENT OF PROBLEM: Wearers of mandibular complete dentures (CDs) often complain of retention and stability problems resulting in poor masticatory function. Evidence suggests that a mandibular overdenture (MOD) stabilized by 2 implants represents the treatment of choice to improve stability and masticatory function. Measurements are needed of the improvement in masticatory function after providing mandibular implant-stabilized overdentures.

    PURPOSE: The purpose of this prospective clinical study was to evaluate the changes in masticatory function from baseline (T0) to 3 months (T1) and 3 years (T2) in participants with MODs and to assess the effect of baseline mandibular bone height and volume on masticatory function after 3 years.

    MATERIAL AND METHODS: Participants were assessed for masticatory function by using masticatory performance involving paraffin wax cubes as an objective measure and by using masticatory ability involving a questionnaire as a subjective measure. Edentulous individuals presenting for replacement dentures were provided with conventional mucosa-supported prostheses and evaluated for masticatory function after a 3-month settling-in period (baseline measure). Before implant placement, baseline measures of bone height and volume were recorded from cone beam computed tomography (CBCT) images. The prostheses were then converted to implant-stabilized mandibular overdentures while any maxillary prostheses remained supported by the mucosa. Masticatory function was reassessed at 3 months and 3 years after insertion of the mandibular overdentures, and the mean changes from baseline were analyzed with the Wilcoxon signed-rank test. The effect of variables on masticatory function was determined by using multivariate linear regression analyses.

    RESULTS: A total of 23 participants were included in the study, with only 1 participant not completing the 3-year assessment. Significant improvement was observed in the masticatory performance (mixing ability index) (P

    Matched MeSH terms: Dental Implants*
  7. Patil PG, Seow LL, Uddanwadikar R, Ukey PD
    J Prosthet Dent, 2021 Jan;125(1):138.e1-138.e8.
    PMID: 33393474 DOI: 10.1016/j.prosdent.2020.09.015
    STATEMENT OF PROBLEM: Mini implants (<3 mm in diameter) are being used as an alternative to standard implants for implant-retained mandibular overdentures; however, they may exhibit higher stresses at the crestal level.

    PURPOSE: The purpose of this finite element analysis study was to evaluate the biomechanical behavior (stress distribution pattern) in the mandibular overdenture, mucosa, bone, and implants when retained with 2 standard implants or 2 mini implants under unilateral or bilateral loading conditions.

    MATERIAL AND METHODS: A patient with edentulous mandible and his denture was scanned with cone beam computed tomography (CBCT), and a 3D mandibular model was created in the Mimics software program by using the CBCT digital imaging and communications in medicine (DICOM) images. The model was transferred to the 3Matics software program to form a 2-mm-thick mucosal layer and to assemble the denture DICOM file. A 12-mm-long standard implant (Ø3.5 mm) and a mini dental implant (Ø2.5 mm) along with the LOCATOR male attachments (height 4 mm) were designed by using the SOLIDWORKS software program. Two standard or 2 mini implants in the canine region were embedded separately in the 3D assembled model. The base of the mandible was fixed, and vertical compressive loads of 100 N were applied unilaterally and bilaterally in the first molar region. The material properties for acrylic resin (denture), titanium (implants), mucosa (tissue), and bone (mandible) were allocated. Maximum von Mises stress and strain values were obtained and analyzed.

    RESULTS: Maximum stresses of 9.78 MPa (bilaterally) and 11.98 MPa (unilaterally) were observed in 2 mini implants as compared with 3.12 MPa (bilaterally) and 3.81 MPa (unilaterally) in 2 standard implants. The stress values in the mandible were observed to be almost double the mini implants as compared with the standard implants. The stresses in the denture were in the range of 3.21 MPa and 3.83 MPa and in the mucosa of 0.68 MPa and 0.7 MPa for 2 implants under unilateral and bilateral loading conditions. The strain values shown similar trends with both implant types under bilateral and unilateral loading.

    CONCLUSIONS: Two mini implants generated an average of 68.15% more stress than standard implants. The 2 standard implant-retained overdenture showed less stress concentration in and around implants than mini implant-retained overdentures.

    Matched MeSH terms: Dental Implants*
  8. Ling BC, Gillings BR
    Asian J Aesthet Dent, 1995;3:17-21.
    PMID: 9063105
    With the prognosis of dental implant replacement of missing teeth becoming better each year, practitioners are focusing their attention on the aesthetic aspects of implantology. However, improvement in aesthetics is only possible with the improvement in implant technology, surgical techniques and prosthodontic procedures. This study aimed at evaluating the effects of various physical and chemical agents on the implant surface; with the view of obtaining increased surface area and biocompatibility. The study found that the treatment of air-aluminum oxide blasted implants using a mixture of 30% HNO3-5% HF acids produced a surface which meets the consideration of aesthetics for implants placed in the anterior maxillary region.
    Matched MeSH terms: Dental Implants*
  9. Qabbani AA, Bayatti SWA, Hasan H, Samsudin AB, Kawas SA
    J Craniofac Surg, 2020 1 3;31(3):e233-e236.
    PMID: 31895847 DOI: 10.1097/SCS.0000000000006106
    To evaluate the ability of the maxillary sinus membrane to produce bone after internal sinus lifting and implant placement without adding exogenous bone graft, and to assess the quality of bone that has been produced 6 months postoperatively.In this retrospective study, 10 subjects who underwent maxillary sinus floor lifting and met the inclusion criteria were selected and then subdivided into: Group-A underwent internal sinus elevation and placement of implants without the use of bone graft and Group-B underwent classical internal sinus lifting and placement of bovine bone particles and then placement of the implant as a control group. Radiofrequency analysis (RFA) values for measuring the Implant Stability Quotient (ISQ) of all implants were measured by Osstell device. CBCT was performed involving linear measurements of the site of sinus lifting for both groups.High RFA values demonstrating excellent biomechanical stability were observed in Group-A compared to Group-B at 6 months postoperatively. Group-A showed a median of ISQ value;78 (8), 77(12), 79(3.5) and 77(4.50). Group-A was significantly higher in ISQ values than Group-B, which showed median and interquartile range (IQR) of ISQ value of [51(12.50), 54(14.50), 55(9), and 55(7.50)]. However, the amount of bone available in group B was significantly higher than group A; [3.5 mm (0.75) and 3.8 mm (0.69)].Internal sinus lifting without bone graft has the ability of bone formation by osteogenic potential of the sinus membrane. Nevertheless, the high quality of bone being produced is of high importance for the success of an implant without the need for an exogenous bone graft. The newly formed bone was significantly of a better quality in Group-A. Thus, it is recommended to perform internal sinus lifting, without adding bone graft material and allow the osteogenic potential of the maxillary sinus membrane to produce its own osteogenic cells.
    Matched MeSH terms: Dental Implantation, Endosseous; Dental Implants*
  10. Mahat NS, Shetty NY, Kohli S, Jamayet NB, Patil P
    Evid Based Dent, 2023 Sep;24(3):142.
    PMID: 37369705 DOI: 10.1038/s41432-023-00904-5
    OBJECTIVE: To analyze the clinical outcomes of implant-supported prostheses and tooth-supported fixed prostheses, fabricated from digital and conventional impression.

    MATERIALS AND METHODS: The literature search was carried out on two electronic databases (PubMed and Cochrane Library). Randomized controlled trials (RCT) published from January 2011 to September 2022 were included. The bias risk was evaluated using Cochrane Risk of Bias Tool 2.0. Further screening was done for meta-analysis according to modified Newcastle-Ottawa scoring criteria. Forest plot was generated using a statistical method of inverse variance of random effect with 95% confidence interval.

    RESULTS: A total of 8 randomized controlled trials were included for systematic review out of which four studies were based on tooth-supported fixed prosthesis and remaining four were based on implant-supported prosthesis. Further screening was conducted and three studies were eligible for meta-analysis. Tooth-supported fixed prosthesis fabricated from digital impression showed no significant difference in the marginal fit in any region measured, except for occlusal region where conventional impression showed more favorable marginal fit. Implant-supported prosthesis fabricated from digital impression showed survival rates ranging from 97.3 to 100% and there was no statistically significant difference in marginal bone loss (p = 0.14).

    CONCLUSION: Implant-supported prostheses fabricated from digital and conventional impressions show no significant differences in their clinical outcomes. Tooth-supported fixed prostheses fabricated from digital impression have shown favorable findings in terms of marginal fit. Despite that, there is still lack of clinical trials with larger sample size and longer follow-up periods. Future studies that fulfill these two criteria are deemed necessary.

    Matched MeSH terms: Dental Implants*
  11. Sghaireen MG, Alduraywish AA, Srivastava KC, Shrivastava D, Patil SR, Al Habib S, et al.
    PMID: 32708165 DOI: 10.3390/ijerph17145253
    Diabetes mellitus is known to compromise the various aspects of homeostasis, including the immune response and the composition of oral microflora. One of the oral manifestations of diabetes mellitus is tooth loss and the survival rate of dental implants chosen as a treatment modality for its rehabilitation is controversial. The current study aims to evaluate and compare the failure rate of dental implants between well-controlled diabetic and healthy patients. A retrospective study of case-control design was conceptualized with 121 well-controlled diabetic and 136 healthy individuals. Records of subjects who had undergone oral rehabilitation with dental implants between the periods of January 2013 to January 2016 were retrieved. Post-operative evaluation was carried out for all patients for about three years to assess the immediate and long-term success of the procedure. From a total of 742 dental implants, 377 were placed in well-controlled diabetic patients (case group) and 365 in healthy subjects (control group). A comparable (9.81%), but non-significant (p = 0.422) failure rate was found in the case group in comparison to the control group (9.04%). A non-significant (p = 0.392) raised number (4.98%) of failure cases were reported among females in comparison to males (4.44%). In respect to arch, the mandibular posterior region was reported as the highest failure cases (3.09%; p = 0.411), with 2.29% of cases reported in the mandibular anterior (p = 0.430) and maxillary posterior (p = 0.983) each. The maxillary anterior region was found to have the least number (1.75%; p = 0.999) of failure cases. More (4.98%; p = 0.361) cases were reported to fail during the functional loading stage in contrast to osseointegration (4.44%; p = 0.365). A well-controlled diabetic status does not impose any additional risk for individuals undergoing dental implant therapy.
    Matched MeSH terms: Dental Implants
  12. Chai WL, Moharamzadeh K, van Noort R, Emanuelsson L, Palmquist A, Brook IM
    J Periodontal Res, 2013 Oct;48(5):663-70.
    PMID: 23442017 DOI: 10.1111/jre.12062
    Studies of peri-implant soft tissue on in vivo models are commonly based on histological sections prepared using undecalcified or 'fracture' techniques. These techniques require the cutting or removal of implant during the specimen preparation process. The aim of this study is to explore a new impression technique that does not require any cutting or removal of implant for contour analysis of soft tissue around four types of titanium (Ti) surface roughness using an in vitro three-dimensional oral mucosal model (3D OMM).
    Matched MeSH terms: Dental Implants*
  13. Vohra F, Al-Kheraif AA, Ab Ghani SM, Abu Hassan MI, Alnassar T, Javed F
    J Prosthet Dent, 2015 Sep;114(3):351-7.
    PMID: 26047803 DOI: 10.1016/j.prosdent.2015.03.016
    STATEMENT OF PROBLEM: Zirconia implants have been used for oral rehabilitation; however, evidence of their ability to maintain crestal bone and periimplant soft tissue health is not clear.

    PURPOSE: The purpose of this systematic review was to evaluate crestal bone loss (CBL) around zirconia dental implants and clinical periimplant inflammatory parameters.

    MATERIAL AND METHODS: The focus question addressed was, "Do zirconia implants maintain crestal bone levels and periimplant soft tissue health?" Databases were searched for articles from 1977 through September 2014 with different combinations of the following MeSH terms: "dental implants," "zirconium," "alveolar bone loss," "periodontal attachment loss," "periodontal pocket," "periodontal index." Letters to the editor, case reports, commentaries, review articles, and articles published in languages other than English were excluded.

    RESULTS: Thirteen clinical studies were included. In 8 of the studies, the CBL around zirconia implants was comparable between baseline and follow-up. In the other 5 studies, the CBL around zirconia implants was significantly higher at follow-up. Among the studies that used titanium implants as controls, 2 studies showed significantly higher CBL around zirconia implants, and in 1 study, the CBL around zirconia and titanium implants was comparable. The reported implant survival rates for zirconia implants ranged between 67.6% and 100%. Eleven studies selectively reported the periimplant inflammatory parameters.

    CONCLUSIONS: Because of the variations in study design and methodology, it was difficult to reach a consensus regarding the efficacy of zirconia implants in maintaining crestal bone levels and periimplant soft tissue health.

    Matched MeSH terms: Dental Implants*
  14. Patil PG, Seow LL
    J Prosthet Dent, 2020 May;123(5):710-716.
    PMID: 31558274 DOI: 10.1016/j.prosdent.2019.07.015
    STATEMENT OF PROBLEM: Single-implant-retained overdentures are an alternative treatment option for an edentulous mandible. However, evaluation of their clinical performance with an immediate loading protocol is lacking.

    PURPOSE: The purpose of this prospective randomized controlled clinical study was to evaluate crest bone-level changes and patient satisfaction with mandibular overdentures retained by 1 or 2 titanium-zirconium (Ti-Zr) implants with immediate loading protocols after 1 year.

    MATERIAL AND METHODS: Thirty-six Ti-Zr implants were placed in 24 participants (single central implant in 12 participants and 2 interforaminal implants in 11 participants) by a single operator. LOCATOR attachments were used to retain the mandibular overdentures with an immediate loading protocol, and observations were made at 1 month and 1 year. Changes to the crestal bone level were evaluated with digital periapical radiographs. A 100-mm visual analog scale (VAS) was used to evaluate patient satisfaction. The Mann-Whitney U test was used to analyze the data.

    RESULTS: At 1 month, the mean crestal bone loss was 0.23 mm in the 2-implant group (n=22) and 0.39 mm (P=.181) in the single-implant group (n=11). At 1 year, the bone loss was 0.67 mm in the 2-implant group and 0.88 mm (P=.248) in the single-implant group. The mean VAS score for patient satisfaction level increased from 38.3% to 49.7% for single-implant participants and from 40.5% to 54.8% for 2-implant participants 1 month after implant placement (P=.250) and from 38.3% to 54.5% for single-implant participants and from 40.5% to 58.9% for 2-implant participants after 1 year (P=.341).

    CONCLUSIONS: Single-implant-retained mandibular overdentures with an immediate loading protocol may represent a viable treatment option considering crestal bone-level changes and patient satisfaction compared with 2-implant-retained mandibular overdentures after 1 year of follow-up.

    Matched MeSH terms: Dental Implants*; Immediate Dental Implant Loading*
  15. Patil PG, Seow LL, Uddanwadikar R, Pau A, Ukey PD
    J Prosthet Dent, 2024 Feb;131(2):281.e1-281.e9.
    PMID: 37985307 DOI: 10.1016/j.prosdent.2023.10.023
    STATEMENT OF PROBLEM: The 2-implant mandibular overdenture (2IMO) is a popular treatment for patients with mandibular edentulism. However, information on the influence of implant positions on crestal strain is lacking.

    PURPOSE: The purpose of this in vitro study was to evaluate the crestal strain around 2 implants to support mandibular overdentures when placed at different positions.

    MATERIAL AND METHODS: Edentulous mandibles were 3-dimensionally (3D) designed separately with 2 holes for implant placement at similar distances of 5, 10, 15, and 20 mm from the midline, resulting in 4 study conditions. The complete denture models were 3D designed and printed from digital imaging and communications in medicine (DICOM) images after scanning the patient's denture. Two 4.3×12-mm dummy implants were placed in the preplanned holes. Two linear strain gauges were attached on the crest of the mesial and distal side of each implant (CH1, CH2, CH3, and CH4) and connected to a computer to record the electrical signals. Male LOCATOR attachments were attached, the mucosal layer simulated, and the denture picked up with pink female nylon caps. A unilateral and bilateral force of 100 N was maintained for 10 seconds for each model in a universal testing machine while recording the maximum strains in the DCS-100A KYOWA computer software program. Data were analyzed by using 1-way analysis of variance, the Tukey post hoc test, and the paired t test (α=.05).

    RESULTS: Under bilateral loading, the strain values indicated a trend with increasing distance between the implants with both right and left distal strain gauges (CH4 and CH1). The negative (-ve) values indicated the compressive force, and the positive (+ve) values indicated the tensile force being applied on the strain gauges. The strain values for CH4 ranged between -166.08 for the 5-mm and -251.58 for the 20-mm position; and for CH1 between -168.08 for the 5-mm and -297.83 for the 20-mm position. The remaining 2 mesial strain gauges for all 4 implant positions remained lower than for CH4 and CH1. Under unilateral-right loading, only the right-side distal strain gauge CH4 indicated the increasing trend in the strain values with -147.5 for the 5-mm, -157.17 for the 10-mm, -209.33 for the 15-mm, and -234.75 for the 20 mm position. The remaining 3 strain gauges CH3, CH2, and CH1 ranged between -28.33 and -107.17. For each position for both implants, significantly higher (P

    Matched MeSH terms: Dental Implants*
  16. Tan SJ, Baharin B, Nabil S, Mohd N, Zhu Y
    J Evid Based Dent Pract, 2021 Jun;21(2):101543.
    PMID: 34391557 DOI: 10.1016/j.jebdp.2021.101543
    OBJECTIVES: To comprehensively evaluate implant survival, clinical and biochemical parameters, as well as possible dose-response relationship with hemoglobin A1c (HbA1c) in patients with differing diabetic control.

    METHODOLOGY: Five electronic databases were searched for studies that compared implant outcomes in patients with differing HbA1c values. Research quality was evaluated using Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool. Narrative synthesis and meta-analysis were performed for survival rate, plaque index (PI), bleeding on probing (BOP), probing pocket depth, and marginal bone loss (MBL). Categorical dose-response meta-analysis (DRMA) was conducted according to length of follow-up.

    RESULTS: Twenty-two studies met the inclusion criteria. Prospective studies were mostly of moderate quality, but non-prospective papers had serious to critical risk of bias. Survival rate was high for the first 3 years (92.6%-100%) for patients with HbA1c less than 8%. Meta-analysis revealed worsening clinical parameters with increasing HbA1c. DRMA further established a significant dose-response relationship between glycemic control with BOP (10% more bleeding, 95% CI 0.05-0.16, P = .008) and MBL (0.05 mm more bone loss, 95% CI 0.01-0.09, P = .002) per HbA1c category, but no association with probing pocket depth. Osseointegration progressed at a slower rate, and inflammatory cytokines and bone biomarkers were adversely affected in patients with HbA1c above 8%.

    CONCLUSION: Moderate evidence suggests a high short-term survival but possible dose-response trend of worsening BOP and MBL in association with glycemic control. Clinically, HbA1c values must be considered for risk assessment before placement and throughout the lifespan of the implant placed in a patient with diabetes.

    Matched MeSH terms: Dental Implants*
  17. Taiyeb Ali, T.B.
    Ann Dent, 1997;4(1):-.
    MyJurnal
    Endoseous Implant insertion for the replacement of missing teeth is the state of the art at present times. An understanding of the biology of the perimplant tissues is imperative for the overall success in the dental rehabilitation of a patient with fixture supported prosthesis. The dental implant tissue interface comprises bone, both cortical and cancellous bone; supracrestal connective tissue and the epithelial attachment. A comprehensive review of the response of bone during the postoperative or healing phase, the loading or remodelling phase and during the steady phase is described.
    Matched MeSH terms: Dental Implants
  18. Alam MK, Rahman SA, Rahaman SA, Basri R, Sing Yi TT, Si-Jie JW, et al.
    PLoS One, 2015;10(10):e0140438.
    PMID: 26465146 DOI: 10.1371/journal.pone.0140438
    The aim of this study is to evaluate the satisfaction of patients with posterior implants in relation to the clinical success criteria and surface electromyography (sEMG) findings of the masseter and temporalis muscles. Total 42 subjects were investigated. Twenty one subjects with posterior dental implants were interviewed using a questionnaire and the clinical success criteria were determined based on The International Congress of Oral Implantologists. The myofunction of the masticatory muscles were assessed using sEMG (21 subjects) and compared to the control group of subjects without implants (21 subjects). Out of 21 subjects, all were satisfied with the aesthetics of their implant. Twenty of them (95.2%) were satisfied with its function and stability. As for clinical criteria, 100% (50) of the implants were successful with no pain, mobility or exudates. sEMG findings showed that patients have significantly lower (p<0.01) basal or resting median power frequency but with muscle burst. During chewing, control subjects showed faster chewing action. There was no difference in reaction and recovery time of clenching for both groups. In conclusion, the satisfaction of implant patients was high, and which was in relation to the successful clinical success criteria and sEMG findings.
    Matched MeSH terms: Dental Implants*
  19. Isa, Z.M., Hobkirk, J.A.
    Ann Dent, 2000;7(1):-.
    MyJurnal
    Currently many dental implant systems with varied and numerous components are available commercially, and with new implant systems and designs emerging, it is essential that the user understands that any system selected should be based on sound scientific principles and capable of osseoil!tegration. This has been defined in many different ways, with biomaterial, biological and biomechanical factors being the main considerations. The final restoration is based on both biological tissue and mechanical components. As the success of osseointegration is based on the clinical outcome, clinicians must ensure that the stresses that the superstructure, implant, and surrounding bone are subjected to are within the tolerable limits of the various components, even though the degree of tolerance has not yet been fully defined.
    Matched MeSH terms: Dental Implants
  20. Mehrali M, Shirazi FS, Mehrali M, Metselaar HS, Kadri NA, Osman NA
    J Biomed Mater Res A, 2013 Oct;101(10):3046-57.
    PMID: 23754641 DOI: 10.1002/jbm.a.34588
    Functionally graded material (FGM) is a heterogeneous composite material including a number of constituents that exhibit a compositional gradient from one surface of the material to the other subsequently, resulting in a material with continuously varying properties in the thickness direction. FGMs are gaining attention for biomedical applications, especially for implants, owing to their reported superior composition. Dental implants can be functionally graded to create an optimized mechanical behavior and achieve the intended biocompatibility and osseointegration improvement. This review presents a comprehensive summary of biomaterials and manufacturing techniques researchers employ throughout the world. Generally, FGM and FGM porous biomaterials are more difficult to fabricate than uniform or homogenous biomaterials. Therefore, our discussion is intended to give the readers about successful and obstacles fabrication of FGM and porous FGM in dental implants that will bring state-of-the-art technology to the bedside and develop quality of life and present standards of care.
    Matched MeSH terms: Dental Implants*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links