Displaying publications 1 - 20 of 76 in total

Abstract:
Sort:
  1. Baig MR, Rajan G, Yunus N
    Gerodontology, 2012 Jun;29(2):e1140-5.
    PMID: 21615782 DOI: 10.1111/j.1741-2358.2010.00433.x
    Dental rehabilitation of a completely edentulous geriatric patient has always been a challenge to the clinician, especially in treating those with higher expectations and demands. Treatment duration and the amount of residual alveolar bone available are often important considerations when planning for dental implant-based fixed treatment for these patients. With the introduction of zygomatic implants, a graftless alternative solution has emerged for deficient maxillary bone with provision for immediate loading. This article describes the treatment of a completely edentulous elderly patient using zygomatic implants in conjunction with conventional implants. The implants were immediately loaded using a definitive acrylic resin fixed denture reinforced with a cast metal framework, to provide function and aesthetics.
    Matched MeSH terms: Dental Implants*; Immediate Dental Implant Loading; Dental Implant-Abutment Design
  2. Apratim A, Eachempati P, Krishnappa Salian KK, Singh V, Chhabra S, Shah S
    J Int Soc Prev Community Dent, 2015 May-Jun;5(3):147-56.
    PMID: 26236672 DOI: 10.4103/2231-0762.158014
    Titanium has been the most popular material of choice for dental implantology over the past few decades. Its properties have been found to be most suitable for the success of implant treatment. But recently, zirconia is slowly emerging as one of the materials which might replace the gold standard of dental implant, i.e., titanium.
    Matched MeSH terms: Dental Implants
  3. Chai WL, Brook IM, Emanuelsson L, Palmquist A, van Noort R, Moharamzadeh K
    J Biomed Mater Res A, 2012 Feb;100(2):269-77.
    PMID: 22045611 DOI: 10.1002/jbm.a.33245
    A three dimensional tissue-engineered human oral mucosal model (3D OMM) used in the investigation of implant-soft tissue interface was recently reported. The aim of this study was to examine the ultrastructural features of soft tissue attachment to various titanium (Ti) implant surfaces based on the 3D OMM. Two techniques, that is, focus ion beam (FIB) and electropolishing techniques were used to prepare specimens for transmission electron microscopic (TEM) analysis of the interface. The 3D OM consisting of both epithelial and connective tissue layers was constructed by co-culturing human oral keratinocytes and fibroblasts onto an acellular dermis scaffold. Four types of Ti surface topographies were tested: polished, machined (turned), sandblasted, and TiUnite. The specimens were then processed for TEM examination using FIB (Ti remained) and electropolishing (Ti removed) techniques. The FIB sections showed some artifact and lack of details of ultrastructural features. In contrast, the ultrathin sections prepared from the electropolishing technique showed a residual Ti oxide layer, which preserved the details for intact ultrastructural interface analysis. There was evidence of hemidesmosome-like structures at the interface on the four types of Ti surfaces, which suggests that the tissue-engineered oral mucosa formed epithelial attachments on the Ti surfaces.
    Matched MeSH terms: Dental Implants*
  4. Lim D, Parumo R, Chai MB, Shanmuganathan J
    J Oral Implantol, 2017 Jun;43(3):228-231.
    PMID: 27996585 DOI: 10.1563/aaid-joi-D-16-00172
    Displacement of dental implants into the maxillary sinus is a rare complication. This article presents a case of displaced dental implant into maxillary sinus. Retrieval of the dental implant from left maxillary sinus was performed via endoscopic sinus surgery. This case highlighted a delayed referral of a 53-year-old male by a general dental practitioner for management of a dislodged dental implant into the left maxillary antrum. The implant was dislodged during placement of a healing abutment 4 months after implant insertion to replace missing 25. Cone beam computerized tomography revealed the displaced implant was located at the ostium of the left nose. A sudden change in sinonasal pressure when the patient took a deep breath during the procedure may have created a negative pressure and suction effect causing the implant to be dislodged and embedded at the ostium. In view of its position, a referral to an otorhinolaryngologist was made for endoscopic removal of the displaced implant. This case also highlighted the need for inter disciplinary cooperation in the management of such a complication for the best interest of the patients.
    Matched MeSH terms: Dental Implants*
  5. Yunus N, Abdullah H, Hanapiah F
    J Prosthet Dent, 2001 Jun;85(6):540-3.
    PMID: 11404753
    This article describes the occlusal rehabilitation of a partially edentulous patient who did not want a removable partial denture. Implants and extensive fixed restorations were used to restore posterior support and treat severely worn dentition, respectively. The treatment offered the patient a functional and esthetic result.
    Matched MeSH terms: Dental Implantation, Endosseous; Dental Implants*
  6. Wey MC, Shim CN, Lee MY, Jamaluddin M, Ngeow WC
    Aust Orthod J, 2012 May;28(1):17-21.
    PMID: 22866589
    This study aimed to establish a safety zone for the placement of mini-implants in the buccal surface between the second maxillary premolar (PM2) and first maxillary molar (M1) of Mongoloids.
    Matched MeSH terms: Dental Implants
  7. Bapat RA, Dharmadhikari S, Chaubal TV, Amin MCIM, Bapat P, Gorain B, et al.
    Heliyon, 2019 Oct;5(10):e02544.
    PMID: 31687479 DOI: 10.1016/j.heliyon.2019.e02544
    Dendrimers are hyperbranched nanoparticle structures along with its surface modifications can to be used in dental biomaterials for biomimetic remineralisation of enamel and dentin. The review highlights the therapeutic applications of dendrimers in the field of dentistry. It addresses the possible mechanisms of enhancement of mechanical properties of adhesives and resins structure. Dendrimers due to its unique construction of possessing inner hydrophobic and outer hydrophilic structure can act as drug carrier for delivery of antimicrobial drugs for treatment of periodontal diseases and at peripheral dental implant areas. Dendrimers due to its hyperbranched structures can provides a unique drug delivery vehicle for delivery of a drug at specific site for sustained release for therapeutic effects. Thus, dendrimers can be one of the most important constituents which can be incorporated in dental biomaterials for better outcomes in dentistry.
    Matched MeSH terms: Dental Implants
  8. Kumar SR, Patil PG, Choy CS, Veerakumarasivam A
    Indian J Dent Res, 2020 5 22;31(2):197-202.
    PMID: 32436897 DOI: 10.4103/ijdr.IJDR_553_17
    Background: The location of the inferior alveolar nerve (IAN) is generally constant in fully grown mandibles. If we know its average distance from the lower border of the mandible, available bone length from the crest of the edentulous ridge can be estimated by physical measurement of the whole length of mandible in that area. This study aimed to measure the superio-inferior distance of the inferior alveolar nerve (SIDIAN) from the base of the mandible in posterior regions on the right and left side based on cone-beam-computed tomography (CBCT) scans and to evaluate gender and ethnicity-related variations in the Malaysian population.

    Materials and Methods: A total of 100 CBCT-Digital Imaging and Communications in Medicine files of the patients of 3 ethnic populations (Malay, Chinese and Indian) between the ages of 18 and 80 years were selected for the study. The files were imported onto the iCAT software. The measurements of the SIDIAN to the lower border of the mandible in molar regions were done on both sides. The data was analysed using t-test, one-way analysis of variance test, and correlation coefficient test via the SPSS software.

    Results: Statistically significant positive correlations were identified between the SIDIAN from the lower border of the mandible in the first and second molar regions within the same side as well as between both sides of the mandible (r ≈ 0.8). There were no statistically significant differences between genders. However, there were statistically significant differences on both molar regions and on both sides in all three ethnic groups (P < 0.05). In general, the SIDIAN from the lower border of the mandible was greatest amongst Chinese and smallest amongst Indians.

    Conclusions: The strong positive correlations on both sides of the mandible indicate the presence of symmetry. Ethnicity-related variations exist in terms of the location of the IAN in the mandible.

    Matched MeSH terms: Dental Implants*
  9. Ahmed P, Bukhari IA, Albaijan R, Sheikh SA, Vohra F
    Photodiagnosis Photodyn Ther, 2020 Dec;32:102077.
    PMID: 33157330 DOI: 10.1016/j.pdpdt.2020.102077
    AIM: The current clinical trial aimed to assess the effectiveness of adjunctive photodynamic therapy (aPDT) and adjunctive antibiotic gel therapy (aAGT) to treat peri-implantitis among patients with type 2 diabetes mellitus (T2DM).

    METHODS: Selected T2DM participants with peri-implantitis were distributed into 3 groups: Group-1: received a single session of adjunctive (aPDT); Group-2: received a single session of adjunctive (aAGT) (metronidazole 400 mg and amoxicillin 500 mg); and Group-3: received MD alone. Clinical (probing depth [PD], bleeding on probing [BOP], and plaque scores [PS]) and radiographic (crestal bone loss [CBL]) peri-implant variables were recorded. Levels of interleukin (IL)-6 and tumor necrosis factor-alpha (TNF-α) were assessed after the collection of peri-implant sulcular fluid (PISF). All the evaluations were carried out at baseline, 3- and 6-months. The significance level was set to p < 0.05.

    RESULTS: At 3-and 6-months of follow-up, all the three groups showed significant alleviation in PS (p < 0.05), BOP (p < 0.05), and PD (p < 0.05) when compared with the baseline. At baseline, no significant variation was observed in all clinical and radiographic peri-implant parameters among all three research groups. At 3-months follow-up, a considerable alleviation of in PS, BOP, PD, and CBL was noticeable in group-1 patients when compared with the baseline. At 6-months follow-up, a comparable difference was observed in BOP, PD, and CBL between group-1 and group-2. At baseline, no significant variation was observed in the PISF levels of IL-6 and TNF-α among all three research groups. At 3- and 6-months follow-up, a considerable alleviation of TNF-α and IL-6 levels was observed in group-1 and group-2 patients, respectively, when compared with the baseline.

    CONCLUSION: The application of aPDT demonstrated improved clinical, radiographic, and immunological peri-implant parameters for the treatment of peri-implantitis among T2DM patients.

    Matched MeSH terms: Dental Implants*
  10. Al-Juboori MJ, AbdulRahaman SB, Hassan A
    Implant Dent, 2013 Aug;22(4):351-5.
    PMID: 23811720 DOI: 10.1097/ID.0b013e318296583d
    To detect the correlation between crestal bone resorption and implant stability during healing period using resonance frequency analysis (RFA).
    Matched MeSH terms: Dental Implantation, Endosseous/methods; Dental Implants*
  11. Chai WL, Brook IM, Palmquist A, van Noort R, Moharamzadeh K
    J R Soc Interface, 2012 Dec 7;9(77):3528-38.
    PMID: 22915635 DOI: 10.1098/rsif.2012.0507
    For dental implants, it is vital that an initial soft tissue seal is achieved as this helps to stabilize and preserve the peri-implant tissues during the restorative stages following placement. The study of the implant-soft tissue interface is usually undertaken in animal models. We have developed an in vitro three-dimensional tissue-engineered oral mucosal model (3D OMM), which lends itself to the study of the implant-soft tissue interface as it has been shown that cells from the three-dimensional OMM attach onto titanium (Ti) surfaces forming a biological seal (BS). This study compares the quality of the BS achieved using the three-dimensional OMM for four types of Ti surfaces: polished, machined, sandblasted and anodized (TiUnite). The BS was evaluated quantitatively by permeability and cell attachment tests. Tritiated water (HTO) was used as the tracing agent for the permeability test. At the end of the permeability test, the Ti discs were removed from the three-dimensional OMM and an Alamar Blue assay was used for the measurement of residual cells attached to the Ti discs. The penetration of the HTO through the BS for the four types of Ti surfaces was not significantly different, and there was no significant difference in the viability of residual cells that attached to the Ti surfaces. The BS of the tissue-engineered oral mucosa around the four types of Ti surface topographies was not significantly different.
    Matched MeSH terms: Dental Implants*
  12. Mahmood, W.A., Watkinson, A.C., Rooney, J.
    Ann Dent, 2000;7(1):-.
    MyJurnal
    The CO2 laser has been actively used clinically for soft tissue surgery. The advantages have been widely acknowledged. In implant related tissue surgery, the use .6f CO2 laser has been debated on whether the heat generated during the procedure would be detrimental to the bone thus losing the implants through disosseointegration. In this preliminary work, CO2 laser was used to perform a simulated gingivectomy of tissue surrounding plasma coated titanium implants. The purpose was to observe the pattern of heat generated at different levels of the implant body. The safe power range and standard precaution was also identified. The results suggested that power output between 6 Watt to 8 Watt in repeated pulsed mode with duration of 5 seconds is considered safe. With this mode the operator
    Matched MeSH terms: Dental Implants
  13. Aljunid S, AlSiweedi S, Nambiar P, Chai WL, Ngeow WC
    J Oral Implantol, 2016 Aug;42(4):349-52.
    PMID: 27078072 DOI: 10.1563/aaid-joi-D-16-00011
    The mandibular canal is a conduit that allows the inferior alveolar neurovascular bundle to transverse the mandible to supply the dentition, jawbone, and soft tissue around the lower lip. It is now acknowledged that the mandibular canal is not a single canal but an anatomical structure with multiple branches and variations. Iatrogenic injury to branches of the mandibular canal that carry a neurovascular bundle has been reported to cause injury to the main canal as severe as if the main canal itself is traumatized. These injuries include bleeding, neurosensory disturbance, or the formation of traumatic neuroma, and so far, they have involved cases with the bifid mandibular canal. This current report presents a case of neurosensory disturbance that resulted from the impingement of a branch of a trifid mandibular canal during implant insertion. Its management included analgesics, reexamination, and reinserting a shorter implant.
    Matched MeSH terms: Dental Implants*
  14. Qabbani AA, Razak NHA, Kawas SA, Sheikh Abdul Hamid S, Wahbi S, Samsudin AR
    J Craniofac Surg, 2017 Jun;28(4):e318-e325.
    PMID: 28230596 DOI: 10.1097/SCS.0000000000003569
    The aim of this study was to determine the efficacy of immediate implant placement with alveolar bone augmentation on socket preservation following atraumatic tooth extraction and comparing it with a tooth alveolar socket that was allowed to heal in a conventional way.Twenty medically fit patients (8 males and 12 females aged between 18 and 40 years) who needed noncomplicated tooth extraction of mandibular premolar teeth were divided randomly and equally into 2 groups. In Group I, the empty extraction socket was left untreated and allowed to heal in a conventional way. In Group II, the immediate implant was placed and the gap between the implant and the inner buccal plate surface of the socket wall was filled with lyophilized bovine bone granules and the wound was covered with pericardium membrane. The patients were followed up clinically and radiologically for regular reviews at 1 week, 3 months, and 9 months postoperative. Cone beam computerized tomography images of the alveolar ridge and socket were analyzed to determine the structural changes of the alveolar ridge. Resonance frequency analysis was measured at 9 months for Group II to assess the degree of secondary stability of the implants by using Osstell machine.A significant difference of bone resorption of 1.49 mm (confidence interval, CI 95%, 0.63-2.35) was observed within the control group at 3 months, and 1.84 mm (P ≤ 0.05) at 9 months intervals. No significant changes of bone resorption were observed in Group II. Comparison between groups showed a highly significant difference at 3 months; 2.56 mm (CI 95% 4.22-0.90) and at 9 months intervals; 3.2 mm (CI 95%, 4.70-1.62) P ≤ 0.001 between Group I and II. High resonance frequency analysis values were observed at 9 months postoperative in Group II.In conclusion, the insertion of immediate implants in fresh extraction sockets together with grafting the circumferential gap between the bony socket wall and the implant surface with bovine bone granules was able to preserve a greater amount of alveolar ridge volume when compared with an extraction socket that was left to heal in a conventional way.
    Matched MeSH terms: Dental Implants, Single-Tooth*
  15. Daood U, Bandey N, Qasim SB, Omar H, Khan SA
    Acta Odontol Scand, 2011 Nov;69(6):367-73.
    PMID: 21449690 DOI: 10.3109/00016357.2011.569507
    To investigate the failure of 15 dental implants (Paragon/Zimmer) in relation to their surface quality.
    Matched MeSH terms: Dental Implants*
  16. Nurul Ain Mohamed Yusof, Mohd Salman Masri, Erni Noor
    Compendium of Oral Science, 2018;5(1):46-53.
    MyJurnal
    Introduction: High survival rates of dental implants were commonly reported even after 10 years of follow up. Nevertheless, complications and failure may occur and the implant would need to be removed. In recent years, the use of autogenous blood products in dental surgery has increased due to its ability to aid the healing of the soft and hard tissues. Clinical case: The case demonstrated the utilisation of concentrated growth factor (CGF) from the patient’s blood for healing following conservative removal of a failed dental implant. Subsequently, the patient showed satisfactory recovery without any infections and clinical complaints. Conclusion: This explantation procedure, together with the use of CGF, may prevent the normal bone resorption and accelerate soft tissue healing. As it is biological in nature having originated from the patient’s blood, it is more readily accepted by the tissues and the risk of infection is low.
    Matched MeSH terms: Dental Implants
  17. Kohli S, Bhatia S, Al-Haddad A, Pulikkotil SJ, Jamayet NB
    J Prosthodont, 2022 Feb;31(2):102-114.
    PMID: 34516686 DOI: 10.1111/jopr.13433
    PURPOSE: This is a systematic review to identify the incidence of pulp necrosis and/or periapical changes among vital teeth which are used as an abutment for crown and fixed partial dentures (FPDs).

    MATERIALS AND METHODS: Two reviewers independently searched two electronic databases, PubMed and Scopus. The search was complemented from references of included studies and published reviews. Studies published in the English language through January 2021 that had assessed and documented the clinical and radiographic failure of crown or FPD in vital permanent teeth due to pulpal or periapical pathology with a follow-up of at least 12 months were selected. Data screening, data collection and extraction of data was performed. Quality of studies involved was analyzed using the Newcastle-Ottawa Quality Assessment Scale for cohort studies. Meta-analysis was done using random effects model. Publication bias was assessed using funnel plots.

    RESULTS: Electronic searches provided 10,075 records among which 20 studies were selected for systematic review and 7 studies were selected for meta-analysis. With respect to quality assessment, all the studies involved were considered as high quality as the score in scale ranged between 6 and 9 as per the Newcastle-Ottawa Quality Assessment Scale for cohort studies. The meta-analyses showed that there was no statistically significant difference in the incidence of the loss of pulp vitality or pulp necrosis through clinical and radiographic examination with the follow up period of 5 years: p < 0.001, 95% CI: 0.96-1.00, I2 = 77.84%; 10 years: p < 0.001, 95% CI: 0.88-0.95, I2 = 93.59%; 15 years: p < 0.001, 95% CI: 0.92-0.96, I2 = 94.83%; and 20 years: p < 0.001, 95% CI: 0.94-0.96, I2 = 95.01%.

    CONCLUSIONS: The meta-analysis revealed clinical and radiographic success rate ranging between 92% to 98% at different follow up periods ranging between 5 years and 20 years. Future high-quality randomized clinical controlled trials with a larger population are required to confirm the evidence as only observational studies were considered in this paper.

    Matched MeSH terms: Dental Implants*
  18. Al-Juboori MJ
    PMID: 25678816 DOI: 10.2147/CCIDE.S76637
    The displacement of a dental implant into the maxillary sinus may lead to implant failure due to exposure of the apical third or the tip of the implant beyond the bone, resulting in soft tissue growth. This case report discusses dental implant placement in the upper first molar area with maxillary sinus involvement of approximately 2 mm. A new technique for progressive implant loading was used, involving immediately loaded implants with maxillary sinus perforation and low primary stability. Follow-up was performed with resonance frequency analysis and compared with an implant placed adjacent in the upper second premolar area using a conventional delayed loading protocol. Implants with maxillary sinus involvement showed increasing stability during the healing period. We found that progressive implant loading may be a safe technique for the placement of immediately loaded implants with maxillary sinus involvement.
    Matched MeSH terms: Dental Implants
  19. Kassim ZH, Nor Hisham ND, Dardiri NA, Goot Heah K, Hazwani Baharuddin I, De Angelis N
    Minerva Stomatol, 2019 Dec;68(6):291-296.
    PMID: 32052617 DOI: 10.23736/S0026-4970.19.04242-0
    BACKGROUND: The aims of this study were to enumerate the primary implant stability quotient (ISQ) value of self-tapping dual etched implants and to explore the influence of parameters such as implant length, implant diameter, age, gender, implant location and osteotomy preparation on the ISQ value.

    METHODS: Retrospective data from clinical worksheets given to participants during two implant courses held between the periods of 2013 to 2014 were evaluated. A total of 61 implants were considered based on the inclusion criteria. The effects of parameters such as implant diameter, implant length, age, gender, implant location and osteotomy protocol on ISQ values were analyzed.

    RESULTS: Mean ISQ value for all implants was 67.21±9.13. Age of patients (P=0.016) and location of implants (P=0.041) had a significant linear relationship with the ISQ values. Within the age limit of the patients in this study, it was found that an increase in one year of patient's age results in 0.20 decrease in ISQ value (95% CI: -0.36, -0.04). However, placing an implant in the posterior maxilla may negatively affect the ISQ with a likely decrease in primary stability by 6.76 ISQ value (95% CI: -13.22, -0.30).

    CONCLUSIONS: The results suggest that the mean ISQ achieved by the participants were comparable with the range reported for this particular type of implants. The patient's age and location of implants were elucidated as the determinant factors of primary implant stability.

    Matched MeSH terms: Dental Implantation, Endosseous*; Dental Implants*
  20. Hassan MH
    Med J Malaysia, 2004 May;59 Suppl B:164-5.
    PMID: 15468869
    There has been, and is still, concern about the high elastic modulus of Ti alloys compared to bone. Any reduction in the Young's modulus value of the implant is expected to enhance stress redistribution to the adjacent bone tissues, minimize stress shielding and eventually prolong device lifetime. Dynamic Monte Carlo simulation is used to predict the gradual reduction in Young's modulus values between the bulk of Ti alloys and the modified surface layers due to Ca ion implantation. The simulation can be used as a screening step when applying new alloys and/or coatings.
    Matched MeSH terms: Dental Implants*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links