Displaying publications 1 - 20 of 34 in total

Abstract:
Sort:
  1. Al-Hashedi AA, Taiyeb-Ali TB, Yunus N
    Aust Dent J, 2016 06;61(2):208-18.
    PMID: 25966305 DOI: 10.1111/adj.12337
    BACKGROUND: Short dental implants can be an alternative to bone augmentation procedures at sites of reduced alveolar bone. Most studies on short implants are retrospective or multicentre reports that lack controlled and consistent comparison between different systems. This study aimed to compare clinical and radiographic outcomes of short implants in two different systems in the posterior mandible.

    METHODS: Twenty patients with two adjacent missing posterior teeth were recruited. Patients were assigned equally and randomly into two groups; Bicon(®) (6 or 8 mm) and Ankylos(®) (8 mm) implants. A two-stage surgical approach and single crowns were used for implant placement and loading. Outcomes included peri-implant clinical parameters, implant stability (Periotest values; PTVs) and peri-implant bone changes, which were assessed at baseline, 2, 6 and 12 months post-loading.

    RESULTS: No implant loss was encountered up to 12 months post-loading. No significant difference in the clinical or radiographic parameters was observed except for PTVs (p < 0.05) that was lower in Ankylos(®) implants.

    CONCLUSIONS: The use of short dental implants was associated with excellent 12 months clinical and radiographic outcomes. Ankylos(®) and Bicon(®) implants demonstrated similar peri-implant soft tissue and alveolar bone changes. However, Ankylos(®) implants demonstrated better implant stability at all evaluation intervals.

    Matched MeSH terms: Dental Prosthesis Design
  2. Siar CH, Toh CG, Ali TB, Seiz D, Ong ST
    Clin Oral Implants Res, 2012 Apr;23(4):438-46.
    PMID: 21435011 DOI: 10.1111/j.1600-0501.2010.02145.x
    A stable oral mucosa is crucial for long-term survival and biofunctionality of implants. Most of this evidence is derived from clinical and animal studies based solely on implant-supported prosthesis. Much less is known about the dimensions and relationships of this soft tissue complex investing tooth-implant-supported bridgework (TISB). The aim here was to obtain experimental evidence on the dimensional characteristics of oral mucosa around TISB with two different abutment designs.
    Matched MeSH terms: Dental Prosthesis Design
  3. Hassan LA, Goo CL
    Dent Mater J, 2021 Sep 30;40(5):1189-1195.
    PMID: 34078778 DOI: 10.4012/dmj.2020-408
    This research aimed to evaluate the effect of cement space on the marginal discrepancy and retention of computer-aided design/computer-aided manufacturing (CAD/CAM) crowns. A total of 30 premolar Frasaco teeth were machined to receive crowns with cement spaces of 70, 90, and 110 μm. The marginal discrepancy measurements were done before and after cementation. Pull-off test was conducted using universal testing machine (UTM). Data was analyzed using two-way mixed ANOVA with post-hoc Bonferroni test and Kruskal-Wallis test. The crowns with cement space of 70 μm showed a significantly higher absolute marginal discrepancy than those with 90 and 110 μm. No significant effect on the crown retention was found. Within the limitations of this study, modifying cement space to 90 μm and 110 μm may improve the marginal adaptation of CAD/CAM crown, whereas adjusting cement space from 70 to 110 μm did not significantly affect the crown retention.
    Matched MeSH terms: Dental Prosthesis Design*
  4. Lui JL
    Dent Traumatol, 2001 Oct;17(5):227-30.
    PMID: 11678543
    The composite reinforcement technique has been used clinically to salvage damaged root-filled teeth compromised by caries, trauma, developmental abnormalities, internal resorption and iatrogenic causes. This clinical case report describes the use of the technique to reattach a fractured fragment in a compromised endodontically treated root besides reinforcing it for continued function in the mouth. Factors of clinical importance related to this additional application; including reattachment of tooth fragments, post crown retention, coronal microleakage and fracture resistance and strength, are also briefly discussed.
    Matched MeSH terms: Dental Prosthesis Design
  5. Baig MR, Rajan G
    Indian J Dent Res, 2010 Apr-Jun;21(2):311-3.
    PMID: 20657109 DOI: 10.4103/0970-9290.66635
    This article describes the immediate placement and loading of implants in the aesthetic zone using an implant-retained, fixed prosthesis with a modified design. One section of the implant prosthesis has cemented crowns and the other section is the conventional screw-retained. This combined approach significantly offsets the unsuitable implant position, alignment or angulation, while ensuring the easy retrievability, repair and maintenance of the prosthesis at the same time.
    Matched MeSH terms: Dental Prosthesis Design
  6. Rajan G, Baig MR, Nesan J, Subramanian J
    Indian J Dent Res, 2010 Jan-Mar;21(1):125-8.
    PMID: 20427922 DOI: 10.4103/0970-9290.62801
    Treatment of patients with aggressive periodontitis has always been a challenge to the clinician. Both young and old are known to be affected by this progressive destructive condition of the supporting dental structures. Although dental implants have been offered as a viable treatment alternative for such patients, additional procedures (like bone grafting) and delayed protocols have limited their usage. This case report describes the treatment of a young patient with aggressive periodontitis using a graftless implant solution. Zygoma implants in conjunction with conventional implants were used with immediate loading.
    Matched MeSH terms: Dental Prosthesis Design
  7. Ishak MI, Abdul Kadir MR, Sulaiman E, Abu Kasim NH
    Int J Oral Maxillofac Surg, 2012 Sep;41(9):1077-89.
    PMID: 22575179 DOI: 10.1016/j.ijom.2012.04.010
    The aim of this study was to compare two different types of surgical approaches, intrasinus and extramaxillary, for the placement of zygomatic implants to treat atrophic maxillae. A computational finite element simulation was used to analyze the strength of implant anchorage for both approaches in various occlusal loading locations. Three-dimensional models of the craniofacial structures surrounding a region of interest, soft tissue and framework were developed using computed tomography image datasets. The implants were modelled using computer-aided design software. The bone was assumed to be linear isotropic with a stiffness of 13.4 GPa, and the implants were assumed to be made of titanium with a stiffness of 110 GPa. Masseter forces of 300 N were applied at the zygomatic arch, and occlusal loads of 150 N were applied vertically onto the framework surface at different locations. The intrasinus approach demonstrated more satisfactory results and could be a viable treatment option. The extramaxillary approach could also be recommended as a reasonable treatment option, provided some improvements are made to address the cantilever effects seen with that approach.
    Matched MeSH terms: Dental Prosthesis Design/methods*
  8. Mehrali M, Shirazi FS, Mehrali M, Metselaar HS, Kadri NA, Osman NA
    J Biomed Mater Res A, 2013 Oct;101(10):3046-57.
    PMID: 23754641 DOI: 10.1002/jbm.a.34588
    Functionally graded material (FGM) is a heterogeneous composite material including a number of constituents that exhibit a compositional gradient from one surface of the material to the other subsequently, resulting in a material with continuously varying properties in the thickness direction. FGMs are gaining attention for biomedical applications, especially for implants, owing to their reported superior composition. Dental implants can be functionally graded to create an optimized mechanical behavior and achieve the intended biocompatibility and osseointegration improvement. This review presents a comprehensive summary of biomaterials and manufacturing techniques researchers employ throughout the world. Generally, FGM and FGM porous biomaterials are more difficult to fabricate than uniform or homogenous biomaterials. Therefore, our discussion is intended to give the readers about successful and obstacles fabrication of FGM and porous FGM in dental implants that will bring state-of-the-art technology to the bedside and develop quality of life and present standards of care.
    Matched MeSH terms: Dental Prosthesis Design
  9. Saidin S, Abdul Kadir MR, Sulaiman E, Abu Kasim NH
    J Dent, 2012 Jun;40(6):467-74.
    PMID: 22366313 DOI: 10.1016/j.jdent.2012.02.009
    The aim of this study was to analyse micromotion and stress distribution at the connections of implants and four types of abutments: internal hexagonal, internal octagonal, internal conical and trilobe.
    Matched MeSH terms: Dental Prosthesis Design*
  10. Omar H, Atta O, El-Mowafy O, Khan SA
    J Dent, 2010;38 Suppl 2:e95-9.
    PMID: 20493232 DOI: 10.1016/j.jdent.2010.05.006
    To determine the effect of thickness of porcelain veneers constructed from CAD-CAM on their final color when two resin cements were used.
    Matched MeSH terms: Dental Prosthesis Design/instrumentation*; Dental Prosthesis Design/methods
  11. Baig MR, Buzayan MM, Yunus N
    J Investig Clin Dent, 2018 May;9(2):e12320.
    PMID: 29349910 DOI: 10.1111/jicd.12320
    AIM: The aim of the present study was to assess the accuracy of multi-unit dental implant casts obtained from two elastomeric impression materials, vinyl polyether silicone (VPES) and polyether (PE), and to test the effect of splinting of impression copings on the accuracy of implant casts.

    METHODS: Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05.

    RESULTS: The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05).

    CONCLUSIONS: The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions.

    Matched MeSH terms: Dental Prosthesis Design*
  12. Chai WL, Moharamzadeh K, van Noort R, Emanuelsson L, Palmquist A, Brook IM
    J Periodontal Res, 2013 Oct;48(5):663-70.
    PMID: 23442017 DOI: 10.1111/jre.12062
    Studies of peri-implant soft tissue on in vivo models are commonly based on histological sections prepared using undecalcified or 'fracture' techniques. These techniques require the cutting or removal of implant during the specimen preparation process. The aim of this study is to explore a new impression technique that does not require any cutting or removal of implant for contour analysis of soft tissue around four types of titanium (Ti) surface roughness using an in vitro three-dimensional oral mucosal model (3D OMM).
    Matched MeSH terms: Dental Prosthesis Design*
  13. Chai WL, Moharamzadeh K, Brook IM, Emanuelsson L, Palmquist A, van Noort R
    J. Periodontol., 2010 Aug;81(8):1187-95.
    PMID: 20450401 DOI: 10.1902/jop.2010.090648
    In dental implant treatment, the long-term prognosis is dependent on the biologic seal formed by the soft tissue around the implant. The in vitro investigation of the implant-soft tissue interface is usually carried out using a monolayer cell-culture model that lacks a polarized-cell phenotype. This study developed a tissue-engineered three-dimensional oral mucosal model (3D OMM) to investigate the implant-soft tissue interface.
    Matched MeSH terms: Dental Prosthesis Design
  14. Buzayan MM, Ariffin YT, Yunus N
    J Prosthodont, 2013 Oct;22(7):591-5.
    PMID: 23551843 DOI: 10.1111/jopr.12036
    A method is described for the fabrication of a closed hollow bulb obturator prosthesis using a hard thermoforming splint material and heat-cured acrylic resin. The technique allowed the thickness of the thermoformed bulb to be optimized for weight reduction, while the autopolymerized seal area was covered in heat-cured acrylic resin, thus eliminating potential leakage and discoloration. This technique permits the obturator prosthesis to be processed to completion from the wax trial denture without additional laboratory investing, flasking, and processing.
    Matched MeSH terms: Dental Prosthesis Design*
  15. AL-Makramani BM, Razak AA, Abu-Hassan MI
    J Prosthodont, 2009 Aug;18(6):484-8.
    PMID: 19694015
    PURPOSE: This study investigated the occlusal fracture resistance of Turkom-Cerafused alumina compared to Procera AllCeram and In-Ceram all-ceramic restorations.

    MATERIALS AND METHODS: Sixmaster dies were duplicated from the prepared maxillary first premolar tooth using nonprecious metal alloy (Wiron 99). Ten copings of 0.6 mm thickness were fabricated from each type of ceramic, for a total of thirty copings. Two master dies were used for each group, and each of them was used to lute five copings. All groups were cemented with resin luting cement Panavia F according to manufacturer's instructions and received a static load of 5 kg during cementation. After 24 hours of distilled water storage at 37 degrees C, the copings were vertically compressed using a universal testing machine at a crosshead speed of 1 mm/min.

    RESULTS: The results of the present study showed the following mean loads at fracture: Turkom-Cera (2184 +/- 164 N), In-Ceram (2042 +/- 200 N), and Procera AllCeram (1954 +/- 211 N). ANOVA and Scheffe's post hoc test showed that the mean load at fracture of Turkom-Cera was significantly different from Procera AllCeram (p < 0.05). Scheffe's post hoc test showed no significant difference between the mean load at fracture of Turkom-Cera and In-Ceram or between the mean load at fracture of In-Ceram and Procera AllCeram.

    CONCLUSION: Because Turkom-Cera demonstrated equal to or higher loads at fracture than currently accepted all-ceramic materials, it would seem to be acceptable for fabrication of anterior and posterior ceramic crowns.

    Matched MeSH terms: Dental Prosthesis Design
  16. Shankargouda SB, Sidhu P, Kardalkar S, Desai PM
    J Prosthodont, 2017 Feb;26(2):168-171.
    PMID: 26479878 DOI: 10.1111/jopr.12385
    Residual ridge resorption is a rapid, progressive, irreversible, and inevitable process of bone resorption. Long-standing teeth and implants have been shown to have maintained the bone around them without resorption. Thus, overdenture therapy has been proven to be beneficial in situations where few remaining teeth are present. In addition to the various advantages seen with tooth-supported telescopic overdentures, a few shortcomings can also be expected, including unseating of the overdenture, increased bulk of the prosthesis, secondary caries, etc. The precise transfer of the secondary telescopic copings to maintain the spatial relationship, without any micromovement, remains the most critical step in ensuring the success of the tooth-supported telescopic prosthesis. Thus, a simple and innovative technique of splinting the secondary copings was devised to prevent distortion and micromovement and maintain its spatial relationship.
    Matched MeSH terms: Dental Prosthesis Design*
  17. Farook TH, Barman A, Abdullah JY, Jamayet NB
    J Prosthodont, 2021 Jun;30(5):420-429.
    PMID: 33200429 DOI: 10.1111/jopr.13286
    PURPOSE: Mesh optimization reduces the texture quality of 3D models in order to reduce storage file size and computational load on a personal computer. This study aims to explore mesh optimization using open source (free) software in the context of prosthodontic application.

    MATERIALS AND METHODS: An auricular prosthesis, a complete denture, and anterior and posterior crowns were constructed using conventional methods and laser scanned to create computerized 3D meshes. The meshes were optimized independently by four computer-aided design software (Meshmixer, Meshlab, Blender, and SculptGL) to 100%, 90%, 75%, 50%, and 25% levels of original file size. Upon optimization, the following parameters were virtually evaluated and compared; mesh vertices, file size, mesh surface area (SA), mesh volume (V), interpoint discrepancies (geometric similarity based on virtual point overlapping), and spatial similarity (volumetric similarity based on shape overlapping). The influence of software and optimization on surface area and volume of each prosthesis was evaluated independently using multiple linear regression.

    RESULTS: There were clear observable differences in vertices, file size, surface area, and volume. The choice of software significantly influenced the overall virtual parameters of auricular prosthesis [SA: F(4,15) = 12.93, R2 = 0.67, p < 0.001. V: F(4,15) = 9.33, R2 = 0.64, p < 0.001] and complete denture [SA: F(4,15) = 10.81, R2 = 0.67, p < 0.001. V: F(4,15) = 3.50, R2 = 0.34, p = 0.030] across optimization levels. Interpoint discrepancies were however limited to <0.1mm and volumetric similarity was >97%.

    CONCLUSION: Open-source mesh optimization of smaller dental prostheses in this study produced minimal loss of geometric and volumetric details. SculptGL models were most influenced by the amount of optimization performed.

    Matched MeSH terms: Dental Prosthesis Design
  18. Rahman AM, Nizami MMUI, Jamayet NB, Husein A
    J Coll Physicians Surg Pak, 2017 May;27(5):319-320.
    PMID: 28599699 DOI: 2623
    Matched MeSH terms: Dental Prosthesis Design
  19. Sockalingam S
    J Indian Soc Pedod Prev Dent, 2011 Jan-Mar;29(1):53-6.
    PMID: 21521920 DOI: 10.4103/0970-4388.79938
    Amelogenesis imperfecta represents a group of dental developmental conditions that are genomic in origin. Hypoplastic AI, hypomineralised AI or both in combination were the most common types seen clinically. This paper describes oral rehabilitation of a 9-year-old Malay girl with inherited hypoplastic AI using transparent thermoforming templates. The defective surface areas were reconstructed to their original dimensions on stone cast models of the upper and lower arches using composite, and transparent thermoform templates were fabricated on the models. The templates were used as crown formers to reconstruct the defective teeth clinically using esthetically matching composite. The usage of the templates allowed direct light curing of the composite, accurate reproducibility of the anatomic contours of the defective teeth, reduced chair-side time and easy contouring and placement of homogenous thickness of composite in otherwise inaccessible sites of the affected teeth.
    Matched MeSH terms: Dental Prosthesis Design*
  20. Sadollah A, Bahreininejad A
    J Mech Behav Biomed Mater, 2011 Oct;4(7):1384-95.
    PMID: 21783149 DOI: 10.1016/j.jmbbm.2011.05.009
    Despite dental implantation being a great success, one of the key issues facing it is a mismatch of mechanical properties between engineered and native biomaterials, which makes osseointegration and bone remodeling problematical. Functionally graded material (FGM) has been proposed as a potential upgrade to some conventional implant materials such as titanium for selection in prosthetic dentistry. The idea of an FGM dental implant is that the property would vary in a certain pattern to match the biomechanical characteristics required at different regions in the hosting bone. However, matching the properties does not necessarily guarantee the best osseointegration and bone remodeling. Little existing research has been reported on developing an optimal design of an FGM dental implant for promoting long-term success. Based upon remodeling results, metaheuristic algorithms such as the genetic algorithms (GAs) and simulated annealing (SA) have been adopted to develop a multi-objective optimal design for FGM implantation design. The results are compared with those in literature.
    Matched MeSH terms: Dental Prosthesis Design/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links