Displaying publications 1 - 20 of 104 in total

Abstract:
Sort:
  1. MANOHARAN A
    Med J Malaya, 1961 Mar;15:102-12.
    PMID: 14469397
    Matched MeSH terms: Dust*
  2. Thomas V, Leng YP, Hay TB
    Med J Malaysia, 1976 Jun;30(4):331-3.
    PMID: 979741
    Matched MeSH terms: Dust*
  3. Thomas V, Bock Hay Am Tan, Rajapaksa AC
    Ann Allergy, 1978 Feb;40(2):114-6.
    PMID: 629426
    Three groups of people with different clinical histories and manifestations to house dust were skin tested with Dermatophagoides pteronyssinus extracts. The results showed close correlation between positive skin tests and clinical sensitivity to dust. The correlation was not, however, perfect and, although D. pteronyssinus is a major factor in house dust allergy, it does not appear to be the sole antigen involved.
    Matched MeSH terms: Dust*
  4. Zulkifli A, Ng WH, Chelvam P
    Family Practitioner, 1979;3(5):32-34.
    148 patients, 79 males and 60 females were seen in 1978 at Medical Unit Universiti Kebangsaan Kuala Lumpur. For majority of the patients the attacks of asthma begin at an early age. History of allergies were found in majority of the patients. Family history of asthma was noted in about 50%. Of the allergens that triggers of an attack of asthma, household dusts, rhinitis and pollen tops the list. Of the food the common allergens were shrimps, eggs and crabs. Most of the above allergens can be avoided or counteracted.
    Study site: Medical Unit, Hospital Kuala Lumpur (UKM unit), Malaysia
    Matched MeSH terms: Dust
  5. Wang CY, Yap BH, Delilkan AE
    Chest, 1993 Jun;103(6):1897-9.
    PMID: 8404124
    We present the case of a 24-year-old woman with acute septicemic melioidosis resulting from inhaled infective dust during a blast injury. With appropriate antibiotic treatment and supportive therapy in the ICU, the patient made an uneventful recovery.
    Matched MeSH terms: Dust
  6. Ho TM, Radha K, Shahnaz M, Singaram SP
    Med J Malaysia, 1993 Sep;48(3):308-12.
    PMID: 8183144
    An indirect enzyme linked immunosorbent assay (ELISA) was developed for the diagnosis of allergy to a house dust mite, Dermatophagoides farinae. The efficacy of the ELISA was then evaluated against a prick test using a commercial allergen. Eighty five suspected allergic rhinitis patients from the Otorhinolaryngology Department, Kuala Lumpur General Hospital, were tested with the ELISA and prick test. Prick test and ELISA results were positive in 84.7% and 80.0% of the patients respectively. The ELISA was found to have 87.5% sensitivity, 61.5% specificity, 92.6% positive predictive value, 47.1% negative predictive value, 7.4% false positive and 52.9% false negative. There was total agreement between the prick test and ELISA for prick test grades of 3+ and 4+. It is concluded that the ELISA is a useful assay for detection of individuals who are highly sensitive to D. farinae.
    Matched MeSH terms: Dust
  7. Ng TP, Tan WC
    Ann Acad Med Singap, 1994 Jan;23(1):83-8.
    PMID: 8185279
    We conducted a population-based study involving a stratified cluster disproportionate random sample of 2868 adults aged 20 to 74 years selected from five housing estates (Yishun, Toa Payoh, Jurong East, Geylang/Eunos and Bukit Merah). Chronic rhinitis was defined as the usual presence of symptoms of blocked or running nose, apart from colds or the flu, lasting for more than a year. Allergic rhinitis was considered to be present if these symptoms were associated with conjunctivitis or recognisable provocation by commonly known allergens, namely house dust, dogs, cats, birds, pollen, or medicines. The estimated general population prevalence of chronic rhinitis was 10.8% (95% confidence interval (CI) 8.8-12.7). Higher prevalences were noted in males, in younger adults, in Indians and Chinese, in those with higher socio-economic status, and in Toa Payoh, Jurong East and Geylang/Eunos. The prevalence of allergic rhinitis was 5.5% (95% CI 4.5-6.5). The most common 'allergenic' factor in allergic rhinitis was house dust (73%); provocation by birds, cats or dogs (5%), grass or tree pollens (5%), and medicine (5%) was less common but likely to have been under-recognised. Provocation by change in temperature (54%) and early in the morning (64%) was equally frequent in both 'allergic' and 'non-allergic' rhinitis; cigarette smoke, petrol and diesel fumes, food and work environment were less common (4-12%). Allergic rhinitis was highly significantly associated with asthma (13.9% in allergic rhinitis, 4.4% in non-allergic rhinitis, and 2.2% in non-rhinitic subjects).
    Matched MeSH terms: Dust
  8. Ho TM, Murad S, Kesavapillai R, Singaram SP
    Asian Pac J Allergy Immunol, 1995 Jun;13(1):11-6.
    PMID: 7488338
    This study was conducted to determine the seasonal prevalence of allergies to house dust, D. pteronyssinus, D. farinae, cat fur, dog hair, mixed moulds, mixed grass pollens and American cockroach. A total of 314 patients with clinically suspected allergic rhinitis was examined by prick test using commercial preparations of the above allergens. Total serum IgE of the patients was determined by a Sandwich ELISA. Ninety-six percent of the patients tested positive to more than one allergen. Most were positive to a combination of 4 allergens. More than 70% of the patients were positive to house dust, D. pteronyssinus, D. farinae and cat fur. Analysis indicates that for an individual who tests positive for house dust, there is a very high risk of the person being allergic to the dust mites and cat fur too. Most of the allergens had 2 peak period of high positive PT rates; mixed moulds and mixed grass pollens had 3 peaks. There was significant positive correlation between the monthly positive PT rates against mixed moulds and mixed grass pollens with maximum daily mean temperature and mean temperature at 14.00 hours.
    Matched MeSH terms: Dust
  9. Mariana A, Ho TM, Heah SK
    PMID: 9280009
    In the present study on the life-cycle of Blomia tropicalis, freshly laid eggs were observed until they developed into adults; the development periods between stages were recorded. The eggs took an average of 22.9 +/- 6.4 days to develop to adults. For longevity experiments, newly emerged adults were kept at 25 degrees C and observed until they died. There was no significant difference in longevities of the different sexes (p = 0.053). Production of eggs by mated females were monitored until egg production stopped and the female died. Mated females and males survived an average of 32.2 +/- 15.4 and 30.9 +/- 17.7 days respectively. The difference in longevity of the mated females, and males was not significant (p = 0.747). Longevity of the mated females was found to be significantly (p < 0.05) shorter than unmated females.
    Matched MeSH terms: Dust*
  10. Sam CK, Soon SC, Liam CK, Padmaja K, Cheng HM
    Asian Pac J Allergy Immunol, 1998 Mar;16(1):17-20.
    PMID: 9681124
    We investigated the aeroallergens affecting 200 asthmatics from the University Hospital in Kuala Lumpur, Malaysia and found 164 (82%) patients with skin prick test (SPT) reactivity to one or more of a panel of 14 allergens, which included indoor and outdoor animal and plant aeroallergens. Reactivity was most frequent to the indoor airborne allergens, with 159 (79.5%) reacting to either or both house dust mite (Dermatophagoides) species and 87 (43.5%) to cockroach. The SPT reactivity to house dust mites corresponded with the finding that patients found house dust to be the main precipitant of asthmatic attacks.
    Matched MeSH terms: Dust
  11. Noor H, Yap CL, Zolkepli O, Faridah M
    Med J Malaysia, 2000 Mar;55(1):51-7.
    PMID: 11072491 MyJurnal
    Exposure to Portland cement dust has long been associated with the prevalence of respiratory symptoms and varying degrees of airway obstruction in man. Apart from respiratory diseases, it was also found to be the cause of lung and laryngeal cancer, gastrointestinal tumours and also dermatitis. This study was done to investigate the effect of dust exposure on ventilatory lung function of Portland cement factory workers in Rawang, Selangor. Spirometry tests of 62 male workers (exposed to total dust concentration of 10,180 micrograms/m3 and PM10 of 8049 micrograms/m3) and 70 subjects from UPM (exposed to mean total dust of 192 micrograms/m3 and PM10 of 177 micrograms/m3--controls) revealed significant differences in spirometry values between the groups. The workers showed i) significantly lower FEV1% and FEF25-75%, and higher FMFT, ii) reduced FEV1% with increasing level of dust exposure and iii) higher prevalence of respiratory symptoms. Therefore, we suggest that exposure to dust in the cement factory leads to higher incidence of respiratory symptoms and impaired lung function.
    Matched MeSH terms: Dust*; Industry*
  12. Mariana A, Ho TM, Sofian-Azirun M, Wong AL
    PMID: 11414418
    Allergy to house dust mites (HDM) is an important cause of asthma and rhinitis in Malaysia. This study was carried out to evaluate the dust mite fauna in the Klang Valley. Dust samples were collected from 20 houses from March 1994 to February 1995. Thirty-three dust samples from mattresses were examined monthly for the occurrence of HDM. A total of 22 species in 9 families of HDM was identified. The most common and densely populated species was Blomia tropicalis with an average density of 8,934 mites/g of dust. Dermatophagoides pteronyssinus was the next in abundance, followed by Malayoglyphus intermedius. All houses surveyed were found to be infested with HDM and every house had at least 6 species of HDM. B. tropicalis and D. pteronyssinus were found in all mattresses. HDM in the Klang Valley were found to be highly prevalent and present in high densities. In this study, counts of D. pteronyssinus was found to exceed the proposed exposure threshold of 500 mites/g dust, for triggering acute asthma. Although counts of B. tropicalis exceeded D. pteronyssinus, no conclusion could be made because there is currently no exposure threshold for triggering acute asthma, for this species. Monthly distribution of B. tropicalis and D. pteronyssinus showed 2 peaks and 4 peaks, respectively. The major peak for D. pteronysinus was in January 1995 whereas for B. tropicalis, the major peak was more variable and occurred between November 1994 to January 1995. Both the species showed minor peak in April 1994.
    Matched MeSH terms: Dust/analysis*
  13. Razlan Musa, Lin Naing, Zulkifli Ahmad, Rusli Nordin
    MyJurnal
    The relationship between dust exposure and lung function were investigated in a cross-sectional study of 70 male quarry workers. The investigation included spirometric testing and detailed personal interviews using a structured questionnaire adapted from British Medical Research Council questionnaire on respiratory symptoms. Respiratory symptoms commonly reported by the male workers were shortness of breath (42.9%), chest tightness (37.1 %}, morning phlegm (20.0%) and morning cough (0.8%}. Prevalence of respiratory symptoms was greater in current smokers. Age and duration of employment also had significant relationship with chest tightness. Both FEV, and FVC of these workers were significantly reduced when compared to healthy population. Smoking status, age, and duration of employment were also associated with reduced pulmonary function (p<0.01).
    Key words: respiratory symptoms, lung function and quarry workers
    Matched MeSH terms: Dust
  14. Kamel AG, Faridah H, Yusof S, Norazah A, Nakisah MA
    Trop Biomed, 2004 Dec;21(2):135-8.
    PMID: 16493405 MyJurnal
    Acanthamoeba is an uncommon cause of keratitis but one of the most severe because of the prolonged and painful course of the disease and poor visual outcome. Although contact lens use is the principal risk factor, about 10% of cases occur following trauma and exposure to contaminated soil or water. Two cases of Acanthamoeba keratitis involving women contact lens wearers have previously been reported in Malaysia but this is the first time, a non contact lens related Acanthamoeba keratitis is reported. The case involved a 28 year old Indonesian male construction worker who had a trauma of the right eye during work. His eye was struck by sand and dust particles after which he quickly washed with water from an open tank at the construction site. He experienced pain, redness, glaring and blurring of vision of the right eye three days later. The diagnosis was missed at initial presentation but culture of the corneal scraping had proven Acanthamoeba as the aetiological agent. The history and clinical findings of this trauma related Acanthamoeba keratitis are briefly discussed.
    Matched MeSH terms: Dust
  15. Mimala Arasaratnam, Zailina Hashim, Shamsul Bahari Shamsudin
    MyJurnal
    A cross-sectional study was conducted on 83 female electronics factory workers. The respondents comprised 50 exposed workers who use lead alloy solder and 33 unexposed workers. The objective of this study was to assess the lead exposure of these workers. Breathing zone were sampled using air sampling pumps. Dust samples were collected by wipe method. Venous blood collected and blood pressure were measured. All lead analyses were carried out with Graphite Furnace Atomic Absorption Spectrophotometer. The mean air lead for exposed workers (57 0. ± 0.93 μg/m³) was significantly higher than the unexposed workers (0.0067 ± 0.0045μg/m³) (p
    Matched MeSH terms: Dust
  16. Nadchatram M
    Trop Biomed, 2005 Jun;22(1):23-37.
    PMID: 16880751
    House dust mites have lived in human contact from time immemorial. Human dander or dead skin constitutes the major organic component of the house dust ecosystem. Because the mites feed on dander, dust mites and human association will continue to co-exist as part of our environment. Efficient house-keeping practice is the best form of control to reduce infestation. However, special precautions are important when individuals are susceptible or sensitive to dust mites. House dust mites are responsible for causing asthma, rhinitis and contact dermatitis. The respiratory allergies are caused by the inhalation of dead or live mites, their faecal matter or other byproducts. Immune factors are of paramount importance in the development of dust related or mite induced respiratory diseases. House dust mites were found in some 1,000 samples of dust taken from approximately 330 dwellings in Peninsular Malaysia and Singapore. Mattresses, carpets, corners of a bedroom, and floor beneath the bed are favourable dust mite habitats. The incriminating species based on studies here and elsewhere, as well as many other species of dust mites of unknown etiological importance are widely distributed in Malaysian homes. Density of dust mites in Malaysia and Singapore is greater than in temperate countries. Prevention and control measures with reference to subjects sensitive to dust mite allergies, including chemical control described in studies conducted in Europe and America are discussed. However, a cost free and most practical way to remove mites, their faecal matter and other products is to resort to sunning the bedding and carpets to kill the living mites, and then beaten and brushed to remove the dust and other components.
    Matched MeSH terms: Dust*
  17. Mariana A, Santhana Raj AS, Tan SN, Ho TM
    Trop Biomed, 2007 Dec;24(2):29-37.
    PMID: 18209705
    Many finer taxonomic characters of Blomia tropicalis are not distinctly visible under conventional light microscopy. Scanning electron micrographs of this mite are therefore presented in this paper for better appreciation of the inconspicuous features of the morphology of the species. The differences in morphology of male and female B. tropicalis are also briefly discussed.
    Matched MeSH terms: Dust
  18. Omar M, Sulaiman I, Hassan A, Wood AK
    Radiat Prot Dosimetry, 2007;124(4):400-6.
    PMID: 17510205
    Measurements of external radiation level, radon/thoron daughters concentrations in air and uranium/thorium concentrations in airborne mineral dust at 16 amang plants in Malaysia were carried out for three consecutive months to assess radiation dose to workers. Estimated occupational dose was within the range of 1.7-10.9 mSv y(-1). The mean total dose at the amang plants was 4.1 mSv y(-1). Overall, it was found that the major dose contribution of 80% came from external radiation. Radon/thoron daughters and airborne mineral dust contributed to only 11 and 9% of the total dose, respectively.
    Matched MeSH terms: Dust/analysis
  19. Masitah Alias, Zaini Hamzah
    MyJurnal
    The growing concern over the workers safety and health has lead many factories and organizations do the air monitoring to ensure the airborne at their workplace is safe for the worker’s health and complying the Occupational Safety and Health Act 1994 (Act 514). In this study, the monitoring covers an indoor air quality and chemical exposure to the workers in one of the power plant repair shop. A few workers from different sections namely blasting, welding, grinding, fitting and maintenance area were chosen to assist in the personal monitoring for 8 hours measurement. PM10 were measured at a few sampling points to collect dusts for 24 hours duration. The samples were brought back to the laboratory for gravimetric and SEM-EDAX analysis. The results were certainly exceed the limit for air quality, and many elements were detected such as Fe, Ni, Al, Si, Ca, K, Ba, S, Cr, Zn and Cl. The present of these elements shows that exposure to these particulate matters is quite risky and some measure needs to be taken for remedial action.
    Matched MeSH terms: Dust
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links