Displaying publications 1 - 20 of 49 in total

Abstract:
Sort:
  1. Abdul Aziz SA, Mazlan SA, Ubaidillah U, Shabdin MK, Yunus NA, Nordin NA, et al.
    Materials (Basel), 2019 Oct 28;12(21).
    PMID: 31661837 DOI: 10.3390/ma12213531
    Carbon-based particles, such as graphite and graphene, have been widely used as a filler in magnetorheological elastomer (MRE) fabrication in order to obtain electrical properties of the material. However, these kinds of fillers normally require a very high concentration of particles to enhance the conductivity property. Therefore, in this study, the nanosized Ni-Mg cobalt ferrite is introduced as a filler to soften MRE and, at the same time, improve magnetic, rheological, and conductivity properties. Three types of MRE samples without and with different compositions of Mg, namely Co0.5Ni0.2Mg0.3Fe2O4 (A1) and Co0.5Ni0.1Mg0.4Fe2O4 (A2), are fabricated. The characterization related to the micrograph, magnetic, and rheological properties of the MRE samples are analyzed using scanning electron microscopy (SEM), vibrating sample magnetometer (VSM), and the rheometer. Meanwhile, the effect of the nanosized Ni-Mg cobalt ferrites on the electrical resistance property is investigated and compared with the different Mg compositions. It is shown that the storage modulus of the MRE sample with the nanosized Ni-Mg cobalt ferrites is 43% higher than that of the MRE sample without the nanomaterials. In addition, it is demonstrated that MREs with the nanosized Ni-Mg cobalt ferrites exhibit relatively low electrical resistance at the on-state as compared to the off-state condition, because MRE with a higher Mg composition shows lower electrical resistance when higher current flow occurs through the materials. This salient property of the proposed MRE can be effectively and potentially used as an actuator to control the viscoelastic property of the magnetic field or sensors to measure the strain of the flexible structures by the electrical resistance signal.
    Matched MeSH terms: Elastomers
  2. Abu Bakar MF, Kamerkar U, Abdul Rahman SN, Muhd Sakaff MKL, Othman AS
    Data Brief, 2020 Oct;32:106188.
    PMID: 32904357 DOI: 10.1016/j.dib.2020.106188
    Hevea brasiliensis is exploited for its latex production, and it is the only viable source of natural rubber worldwide. The demand for natural rubber remains high due its high-quality properties, which synthetic rubber cannot compete with. In this paper, we present transcriptomic data and analysis of three H. brasiliensis clones using tissue from latex and bark tissues collected from 10-year-old plant. The combined, assembled transcripts were mapped onto an H. brasiliensis draft genome. Gene ontology analysis showed that the most abundant transcripts related to molecular functions, followed by biological processes and cellular components. Simple sequence repeats (SSR) and single nucleotide polymorphisms (SNP) were also identified, and these can be useful for selection of parental and new clones in a breeding program. Data generated by RNA sequencing were deposited in the NCBI public repository under accession number PRJNA629890.
    Matched MeSH terms: Elastomers
  3. Al-Saleh MA, Yussuf AA, Al-Enezi S, Kazemi R, Wahit MU, Al-Shammari T, et al.
    Materials (Basel), 2019 Nov 27;12(23).
    PMID: 31783544 DOI: 10.3390/ma12233924
    In this research work, graphene nanoplatelets (GNP) were selected as alternative reinforcing nanofillers to enhance the properties of polypropylene (PP) using different compatibilizers called polypropylene grafted maleic anhydride (PP-g-MA) and ethylene-octene elastomer grafted maleic anhydride (POE-g-MA). A twin screw extruder was used to compound PP, GNP, and either the PP-g-MA or POE-g-MA compatibilizer. The effect of GNP loading on mechanical and thermal properties of neat PP was investigated. Furthermore, the influence and performance of different compatibilizers on the final properties, such as mechanical and thermal, were discussed and reported. Tensile, flexural, impact, melting temperature, crystallization temperature, and thermal stability were evaluated by using a universal testing system, differential scanning calorimetry (DSC), and thermogravimetric analysis (TGA). For mechanical properties, it was found that increasing GNP content from 1 wt.% to 5 wt.% increased tensile strength of the neat PP up to 4 MPa. The influence of compatibilizers on the mechanical properties had been discussed and reported. For instance, the addition of PP-g-MA compatibilizer improved tensile strength of neat PP with GNP loading. However, the addition of compatibilizer POE-g-MA slightly decreased the tensile strength of neat PP. A similar trend of behavior was observed for flexural strength. For thermal properties, it was found that both GNP loading and compatibilizers have no significant influence on both crystallization and melting temperature of neat PP. For thermal stability, however, it was found that increasing the GNP loading had a significant influence on improving the thermal behavior of neat PP. Furthermore, the addition of compatibilizers into the PP/GNP nanocomposite had slightly improved the thermal stability of neat PP.
    Matched MeSH terms: Silicone Elastomers; Elastomers
  4. Anuar K, Hamdan S
    Talanta, 1992 Dec;39(12):1653-6.
    PMID: 18965586
    A new lead(II) electrode has been constructed with poly(hydroxamic acid) (PHXA) as the active material and silicone rubber as the supporting material. The electrode gave near Nerstian response over the concentration range 4 x 10(-5)-1 x 10(-2)M lead(II). The detection limit of the electrode is approximately 4 x 10(-6)M and the electrode works well in the pH range 4.5-6.0. The response time was 50-120 sec over the whole concentration range and the electrode has a working life of at least 4 weeks. Iron(III) severely poisoned the electrode membrane. Nickel(II) and mercury(II) gave very strong interference compared to copper(II), silver(I), cobalt(II), sodium(I), potassium(I), zinc(II) and cadmium(II) which gave some or little interference. Values determined with atomic absorption (AAS) and a commercial lead(II) electrode were in good agreement with those measured with the lead(II) electrode reported here.
    Matched MeSH terms: Silicone Elastomers
  5. Ataollahi F, Pramanik S, Moradi A, Dalilottojari A, Pingguan-Murphy B, Wan Abas WA, et al.
    J Biomed Mater Res A, 2015 Jul;103(7):2203-13.
    PMID: 24733741 DOI: 10.1002/jbm.a.35186
    Extracellular environments can regulate cell behavior because cells can actively sense their mechanical environments. This study evaluated the adhesion, proliferation and morphology of endothelial cells on polydimethylsiloxane (PDMS)/alumina (Al2 O3 ) composites and pure PDMS. The substrates were prepared from pure PDMS and its composites with 2.5, 5, 7.5, and 10 wt % Al2 O3 at a curing temperature of 50°C for 4 h. The substrates were then characterized by mechanical, structural, and morphological analyses. The cell adhesion, proliferation, and morphology of cultured bovine aortic endothelial (BAEC) cells on substrate materials were evaluated by using resazurin assay and 1,1'-dioctadecyl-1,3,3,3',3'-tetramethylindocarbocyanine perchlorate-acetylated LDL (Dil-Ac-LDL) cell staining, respectively. The composites (PDMS/2.5, 5, 7.5, and 10 wt % Al2 O3 ) exhibited higher stiffness than the pure PDMS substrate. The results also revealed that stiffer substrates promoted endothelial cell adhesion and proliferation and also induced spread morphology in the endothelial cells compared with lesser stiff substrates. Statistical analysis showed that the effect of time on cell proliferation depended on stiffness. Therefore, this study concludes that the addition of different Al2 O3 percentages to PDMS elevated substrate stiffness which in turn increased endothelial cell adhesion and proliferation significantly and induced spindle shape morphology in endothelial cells.
    Matched MeSH terms: Elastomers/chemistry*
  6. Atikah Ismail, Azman Hassan, Aznizam Abu Bakar, Jawaid M
    Sains Malaysiana, 2013;42:429-434.
    The effects of ammonium polyphosphate (APP) as flame retardant and kenaf as fillers on flammability, thermal and mechanical properties of polypropylene (PP) composites were determined. Test specimens were prepared by using a corotating twin screw extruder for the compounding process followed by injection molding. The flame retardancy of the composites was determined by using limiting oxygen index (LOI) test. Addition of flame retardant into kenaf-PP composites significantly increased the LOI values that indicated the improvement of flame retardancy. Thermogravimetric analysis was done to examine the thermal stability of the composites. The addition of kenaf fiber in PP composites decreased the thermal stability significantly but the influence of APP on thermal properties of the kenaf-filled PP composites was not significant. The flexural strength and modulus of the composites increased with the addition of APP into kenaf filled
    PP composite. The addition of APP into kenaf filled PP causes increase in the impact strength while increasing the APP content in the kenaf filled PP composite show decrease in impact strength.
    Matched MeSH terms: Silicone Elastomers
  7. Aziz SAA, Mazlan SA, Ubaidillah U, Mohamad N, Choi SB, Che Aziz MA, et al.
    Int J Mol Sci, 2020 Nov 27;21(23).
    PMID: 33260840 DOI: 10.3390/ijms21239007
    Engineering rubber composites have been widely used as main components in many fields including vehicle engineering and biomedical applications. However, when a rubber composite surface area is exposed to heat or sunlight and over a long-term accelerated exposure and lifecycle of test, the rubber becomes hard, thus influencing the mechanical and rheological behavior of the materials. Therefore, in this study, the deterioration of rheological characteristics particularly the phase shift angle (δ) of silicone rubber (SR) based magnetorheological elastomer (MRE) is investigated under the effect of thermal aging. SR-MRE with 60 wt% of CIPs is fabricated and subjected to a continuous temperature of 100 °C for 72 h. The characterization of SR-MRE before and after thermal aging related to hardness, micrograph, and rheological properties are characterized using low vacuum scanning electron microscopy (LV-SEM) and a rheometer, respectively. The results demonstrated that the morphological analysis has a rough surface and more voids occurred after the thermal aging. The hardness and the weight of the SR-MRE before and after thermal aging were slightly different. Nonetheless, the thermo-rheological results showed that the stress-strain behavior have changed the phase-shift angle (δ) of SR-MRE particularly at a high strain. Moreover, the complex mechanism of SR-MRE before and after thermal aging can be observed through the changes of the 'in-rubber structure' under rheological properties. Finally, the relationship between the phase-shift angle (δ) and the in-rubber structure due to thermal aging are discussed thoroughly which led to a better understanding of the thermo-rheological behavior of SR-MRE.
    Matched MeSH terms: Silicone Elastomers/chemistry*
  8. Balaji AB, Ratnam CT, Khalid M, Walvekar R
    J Biomater Appl, 2018 03;32(8):1049-1062.
    PMID: 29298552 DOI: 10.1177/0885328217750476
    The effect of electron beam radiation on ethylene-propylene diene terpolymer/polypropylene blends is studied as an attempt to develop radiation sterilizable polypropylene/ethylene-propylene diene terpolymer blends suitable for medical devices. The polypropylene/ethylene-propylene diene terpolymer blends with mixing ratios of 80/20, 50/50, 20/80 were prepared in an internal mixer at 165°C and a rotor speed of 50 rpm/min followed by compression molding. The blends and the individual components were radiated using 3.0 MeV electron beam accelerator at doses ranging from 0 to 100 kGy in air and room temperature. All the samples were tested for tensile strength, elongation at break, hardness, impact strength, and morphological properties. After exposing to 25 and 100 kGy radiation doses, 50% PP blend was selected for in vivo studies. Results revealed that radiation-induced crosslinking is dominating in EPDM dominant blends, while radiation-induced degradation is prevailing in PP dominant blends. The 20% PP blend was found to be most compatible for 20-60 kGy radiation sterilization. The retention in impact strength with enhanced tensile strength of 20% PP blend at 20-60 kGy believed to be associated with increased compatibility between PP and EPDM along with the radiation-induced crosslinking. The scanning electron micrographs of the fracture surfaces of the PP/EPDM blends showed evidences consistent with the above contentation. The in vivo studies provide an instinct that the radiated blends are safe to be used for healthcare devices.
    Matched MeSH terms: Elastomers/administration & dosage; Elastomers/chemistry*
  9. Budi Aslinie Md Sabri, Nur Hidayah Mohd Radzi, Fatimatuz Zahira Abdul Hadi, Ikmal HishamIsmai
    MyJurnal
    Objective: To evaluate feasibility of hand gloves as a rubber dam isolation alternative, in respect of physical properties. Materials and Methods: A randomized controlled trial study design was used. Three types of gloves were tested with two types of a rubber dam used as the control group. Cut-out pattern of dumb-bell shapes were made from 35 samples for each type of groups and tensile strength were tested using Universal Testing Machine and the Trapezium X software. All tests for physical requirements were performed in accord-ance with American Society for Testing and Materials D412, Standard Test Methods for Vulcanized Rubber and Thermoplastic Rubbers and Thermoplastic Elastomers-Tension. Findings were analyzed by analysis of vari-ance (ANOVA) and differences were compared using a Tukey-Kramer interval calculated at the 0.05 signifi-cance level. Results: Heavy gauge rubber dam has the highest Mean (calculated at the 0.05 significance level) except for maximum stress calculated at entire area. Medium-gauge rubber dam has significantly higher tensile strength (44.5075 N/mm2) when compared to heavy-gauge rubber dam (35.7787 N/mm2) although it was 0.09mm thinner. Discovery 2020 Powder Free Latex Examination Gloves with tensile strength value of 28.5922 N/mm2 (±3.27366) is more than the minimum requirement specified by American Federal Specification ZZ-R90B Rubber Dam (Dental, 1985) (4000 pounds per square inch or 27.6 N/mm2). For all variable tested, all groups are significantly different from each other. The mean square between the groups was quite large. Conclusion: This study shows that there are significant differences between the physical strength of latex gloves when com-pared to rubber dam. However, the comparison between thickness and tensile strength among various rubber dam, did not correspond proportionately. Only one type of rubber gloves met the minimum requirement but that is just one aspect. In view of these mixed results, more research is needed before we can conclude that it is feasable that we use hand gloves to replace rubber dam.
    Matched MeSH terms: Elastomers
  10. Burhannuddin NL, Nordin NA, Mazlan SA, Aziz SAA, Kuwano N, Jamari SKM, et al.
    Sci Rep, 2021 Jan 13;11(1):868.
    PMID: 33441824 DOI: 10.1038/s41598-020-80539-z
    Carbonyl iron particles (CIPs) is one of the key components in magnetic rubber, known as magnetorheological elastomer (MRE). Apart from the influence of their sizes and concentrations, the role of the particle' shape is pronounced worthy of the attention for the MRE performance. However, the usage of CIPs in MRE during long-term applications may lead to corrosion effects on the embedded CIPs, which significantly affects the performance of devices or systems utilizing MRE. Hence, the distinctions between the two types of MRE embedded in different shapes of spherical and plate-like CIPs, at both conditions of non-corroded and corroded CIPs were investigated in terms of the field-dependent rheological properties of MRE. The plate-like shape was produced from spherical CIPs through a milling process using a rotary ball mill. Then, both shapes of CIPs individually subjected to an accelerated corrosion test in diluted hydrochloric (HCl) at different concentrations, particularly at 0.5, 1.0, and 1.5 vol.% for 30 min of immersion time. Eight samples of CIPs, including non-corroded for both CIPs shapes, were characterized in terms of a morphological study by field emission scanning electron microscope (FESEM) and magnetic properties via vibrating sample magnetometer (VSM). The field-dependent rheological properties of MREs were analyzed the change in the dynamic modulus behavior of MREs via rheometer. From the application perspective, this finding may be useful for the system to be considered that provide an idea to prolong the performance MRE by utilizing the different shapes of CIPs even when the material is fading.
    Matched MeSH terms: Elastomers
  11. Ch'ng SY, Andriyana A, Tee YL, Verron E
    Materials (Basel), 2015 Mar 02;8(3):884-898.
    PMID: 28787977 DOI: 10.3390/ma8030884
    The effect of carbon black on the mechanical properties of elastomers is of great interest, because the filler is one of principal ingredients for the manufacturing of rubber products. While fillers can be used to enhance the properties of elastomers, including stress-free swelling resistance in solvent, it is widely known that the introduction of fillers yields significant inelastic responses of elastomers under cyclic mechanical loading, such as stress-softening, hysteresis and permanent set. When a filled elastomer is under mechanical deformation, the filler acts as a strain amplifier in the rubber matrix. Since the matrix local strain has a profound effect on the material's ability to absorb solvent, the study of the effect of carbon black content on the swelling characteristics of elastomeric components exposed to solvent in the presence of mechanical deformation is a prerequisite for durability analysis. The aim of this study is to investigate the effect of carbon black content on the swelling of elastomers in solvent in the presence of static mechanical strains: simple extension and simple torsion. Three different types of elastomers are considered: unfilled, filled with 33 phr (parts per hundred) and 66 phr of carbon black. The peculiar role of carbon black on the swelling characteristics of elastomers in solvent in the presence of mechanical strain is explored.
    Matched MeSH terms: Elastomers
  12. Chieh, C.W., Asmawi Sanuddin, Reza Afshar, Aidy Ali
    MyJurnal
    The paper presents a simulation work conducted on the elastomer subjected to cyclic loads. A 3D finite element model of elastomer specimen, in accordance to ASTM D412, was developed using CATIA and ANSYS commercial finite element (FEM) packages. Fatigue life predicted from the simulation was compared with well-documented published data and it showed an acceptable agreement. Meanwhile, the simulated strain-life results are slightly lower than the experimental data. Several factors which potentially influenced the variations of the results were noted. Finally, some recommendations are offered at the end of this study to further improve the simulation
    Matched MeSH terms: Elastomers
  13. Gautam Sarkhel, Sanjay Manjhi
    Sains Malaysiana, 2013;42:495-501.
    Industrial pollution issue and dark colour of carbon black, clay based non black filler are getting more importance for reinforcing elastomer. EPDM-Kaolin composites with various maleated EPDM concentration have been prepared by mixing on a two roll mill. The rheometry data showed the optimum cure time increases with increasing compatibilizer concentration without decreasing torque value indicating that acidic functional groups comes from compatibilizer could retard cure rate and increase the optimum cure time rather than change in the ultimate cure state. As the filler
    concentration increases, the edge to edge and face to edge interaction between filler and EPDM increases and the free volume between EPDM molecules is reduced, the storage modulus increases. Moreover, the dynamic mechanical analysis also showed the increase in glass transition temperature with increase in filler concentration due to the inter-tubular diffusion of EPDM inside the clay. It was also observed that with increasing filler concentration, the resistivity and dielectric strength decreases and moreover with increasing compatibilizer concentration the resistivity decreases due to better dispersion of filler helps to build conduction path. The morphological study also revealed that homogeneity of filler dispersion increases with increase in compatibilizer concentration.
    Matched MeSH terms: Elastomers
  14. Ghani, S.H.A.
    Ann Dent, 1996;3(1):-.
    MyJurnal
    Fixed-removable appliance is frequently used to extrude a tooth but the idea of incorporating an acrylic capping or stop has not been documented in the literature. This article reports on a case treated with this new approach and describes the technique used.
    Matched MeSH terms: Silicone Elastomers
  15. Goh TH, Puvan IS, Wong WP, Sivanesaratnam V, Sinnathuray TA
    Int. J. Fertil., 1981;26(2):116-9.
    PMID: 6114062
    The menstrual patterns of 281 women undergoing laparoscopic sterilization with silastic rings were studied prospectively. A significant increase in dysmenorrhea and irregular periods was seen soon after sterilization but this was transient, returning to presterilization levels by 12 months. Menorrhagia was not observed and the amount of menstrual blood loss showed a trend towards normal following sterilization. No permanent adverse effects on menstrual patterns were seen in the 1st year after sterilization. It is suggested that factors other than the sterilization procedure may be responsible for the high prevalence of menstrual dysfunction that has been reported following sterilization.
    Matched MeSH terms: Silicone Elastomers*
  16. Huong KH, Azuraini MJ, Aziz NA, Amirul AA
    J Biosci Bioeng, 2017 Jul;124(1):76-83.
    PMID: 28457658 DOI: 10.1016/j.jbiosc.2017.02.003
    Poly(3-hydroxybutyrate-co-4-hydroxybutyrate) [(P(3HB-co-4HB)] copolymer receives attention as next generation biomaterial in medical application. However, the exploitation of the copolymer is still constrained since such copolymer has not yet successfully been performed in industrial scale production. In this work, we intended to establish pilot production system of the copolymer retaining the copolymer quality which has recently discovered to have novel characteristic from lab scale fermentation. An increase of agitation speed has significantly improved the copolymer accumulation efficiency by minimizing the utilization of substrates towards cell growth components. This is evidenced by a drastic increase of PHA content from 28 wt% to 63 wt% and PHA concentration from 3.1 g/L to 6.5 g/L but accompanied by the reduction of residual biomass from 8.0 g/L to 3.8 g/L. Besides, fermentations at lower agitation and aeration have resulted in reduced molecular weight and mechanical strength of the copolymer, suggesting the role of sufficient oxygen supply efficiency in improving the properties of the resulting copolymers. The KLa-based scale-up fermentation was performed successfully in maintaining the yield and the quality of the copolymers produced without a drastic fluctuation. This suggests that the scale-up based on the KLa values supported the fermentation system of P(3HB-co-4HB) copolymer production in single-stage using mixed-substrate cultivation strategy.
    Matched MeSH terms: Elastomers/metabolism*; Elastomers/chemistry*
  17. Huong KH, Teh CH, Amirul AA
    Int J Biol Macromol, 2017 Aug;101:983-995.
    PMID: 28373050 DOI: 10.1016/j.ijbiomac.2017.03.179
    This study reports the production of P(3HB-co-4HB) [Poly(3-hydroxybutyrate-co-4-hydroxybutyrate)] in possession of high molecular weight and elastomeric properties by Cupriavidus sp. USMAA1020 in single-stage mixed-substrate cultivation system. 1,4-butanediol and 1,6-hexanediol are found to be efficient substrate mixture that has resulted in high copolymer yield, occupying a maximum of 70wt% of the total biomass and producing higher 4HB monomer composition ranging from 31mol% to 41mol%. In substrate mixtures involving 1,6-hexanediol, cleavage of the 6-hydroxyhexanoyl-CoA produces Acetyl-CoA and 4-hydroxybutyryl-CoA. Acetyl-CoA is instrumental in initiating the cell growth in the single-stage fermentation system, preventing 4-hydroxybutyryl-CoA from being utilized via β-oxidation and retained the 4HB monomer at higher ratios. Macroscopic kinetic models of the bioprocesses have revealed that the P(3HB-co-4HB) formation appears to be in the nature of mixed-growth associated with higher formation rate during exponential growth phase; evidenced by higher growth associated constants, α, from 0.0690g/g to 0.4615g/g compared to non-growth associated constants, β, from 0.0092g/g/h to 0.0459g/g/h. The P(3HB-co-31mol% 4HB) produced from the substrate mixture exhibited high weight-average molecular weight, Mwof 927kDa approaching a million Dalton, and possessed elongation at break of 1637% upon cultivation at 0.56wt% C. This is the first report on such properties for the P(3HB-co-4HB) copolymer. The copolymer is highly resistant to polymer deformation after being stretched.
    Matched MeSH terms: Elastomers/metabolism*; Elastomers/chemistry
  18. Ishak Ahmad, Mohd Khairil Saat, Ibrahim Abdullah, Azizah Baharum
    Blends of fibre-reinforced rubber based on natural rubber-thermoplastic (NR/LLDPE) reinforced by aramid fibre have been done using melt blending process. Two different processing methods were used; internal mixer and extrusion compounding in twin screw extruder. Twaron loading in the system was varied from 0 to 30%. It was found that increasing the amount of aramid fibre led to an increase in the tensile strength, tensile modulus and hardness of the composites while the strain decreased rapidly. The results showed that the optimum composition of filler loading in NR/LLDPE blend is 20%. The ,echanical behaviour was caused by the strong Twaron-matrices interaction in the composites and effective stress concentrating function of Twaron. Composites prepared using the twin-screw extruder have a higher tensile strength and tensile using the twin-screw extruder have a higher tensile stength and tensile modulus but lower impact strength compared to those prepared using internal mixer. Study of the fracture surface by scanning electron microscopy showed that the composite prepared using the internal mixer produced random fiber orientation while the twin-screw extruder produced the fibers aligned to the longitudinal direction. The results indicate that the mechanical properties of the composite were significantly influenced by the processing technique.
    Penyediaan komposit getah asli termoplastik daripada NR/LLDPE yang diperkuat gentian Twaron telah dijalankan melalui proses adunan leburan. Dua kaedah penyediaan yang berbeza digunakan iaitu menggunakan mesin pencampur dalaman manakala kaedah kedua menggunakan pengekstrud skru kembar. Kandungan Twaron di dalam komposit telah diubah daripada 0 hingga 30%. Keputusan menunjukkan bahawa penambahan Twaron telah meningkatkan nilai tegasan maksima, modulus Young dan kekuatan hentaman komposit tetapi menurunkan nilai terikan maksima. Kandungan Twaron yang optimum adalah 20%. Kehadiran Twaron telah membentuk satu jaringan saling tindak gentian-matriks menyebabkan kekuatan regangan komposit meningkat. Twaron juga berfungsi sebagai penyerap hentaman yang berkesan. Penyediaan komposit menggunakan pengekstrud skru berkembar telah menghasilkan nilai kekuatan regangan yang lebih tinggi berbanding penggunaan pencampur dalaman sebaliknya kekuatan hentaman yang lebih rendah. Kajian morfologi menggunakan mikroskop imbasan elektron mendapati komposit yang disediakan menggunakan pencampur dalaman menghasilkan gentian dengan orientasi rawak manakala pengekstrud skru kembar menghasilkan orientasi gentian yang selari. Keputusan ini menunjukkan bahawa sifat mekanik komposit NR/LLDPE yang diperkuat Twaron sangat dipengaruhi oleh teknik pemprosesan.
    Matched MeSH terms: Silicone Elastomers
  19. Ismail R
    Data Brief, 2019 Aug;25:104166.
    PMID: 31516921 DOI: 10.1016/j.dib.2019.104166
    Generally, a base isolator is made up of alternate layers of steel and rubber. The idea of adopting magnetoreological elastomers (MREs) in base isolator systems was introduced in the past few years in order to improve the efficiency of base isolator systems. The article provides information on the mechanical corresponding to different carbon black loading loadings of 20 parts per hundred rubber (pphr), 40 pphr and 60 pphr in natural rubber compound. The mechanical dataset described the data from tensile, hardness and rebound test.
    Matched MeSH terms: Elastomers
  20. Johari MAF, Mazlan SA, Nasef MM, Ubaidillah U, Nordin NA, Aziz SAA, et al.
    Sci Rep, 2021 May 25;11(1):10936.
    PMID: 34035434 DOI: 10.1038/s41598-021-90484-0
    The widespread use of magnetorheological elastomer (MRE) materials in various applications has yet to be limited due to the fact that there are substantial deficiencies in current experimental and theoretical research on its microstructural durability behavior. In this study, MRE composed of silicon rubber (SR) and 70 wt% of micron-sized carbonyl iron particles (CIP) was prepared and subjected to stress relaxation evaluation by torsional shear load. The microstructure and particle distribution of the obtained MRE was evaluated by a field emission scanning electron microscopy (FESEM). The influence of constant low strain at 0.01% is the continuing concern within the linear viscoelastic (LVE) region of MRE. Stress relaxation plays a significant role in the life cycle of MRE and revealed that storage modulus was reduced by 8.7%, normal force has weakened by 27%, and stress performance was reduced by 6.88% along approximately 84,000 s test duration time. This time scale was the longest ever reported being undertaken in the MRE stress relaxation study. Novel micro-mechanisms that responsible for the depleted performance of MRE was obtained by microstructurally observation using FESEM and in-phase mode of atomic force microscope (AFM). Attempts have been made to correlate strain localization produced by stress relaxation, with molecular deformation in MRE amorphous matrix. Exceptional attention was focused on the development of molecular slippage, disentanglement, microplasticity, microphase separation, and shear bands. The relation between these microstructural phenomena and the viscoelastic properties of MRE was diffusely defined and discussed. The presented MRE is homogeneous with uniform distribution of CIP. The most significant recent developments of systematic correlation between the effects of microstructural deformation and durability performance of MRE under stress relaxation has been observed and evaluated.
    Matched MeSH terms: Elastomers
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links