Displaying publications 1 - 20 of 75 in total

Abstract:
Sort:
  1. Malini M, Kwan TK, Perumal R
    Biochem. Mol. Biol. Int., 1994 Feb;32(2):279-90.
    PMID: 8019433
    In vivo studies involved monitoring the effect of morphine administration on catecholamine biosynthesis by the brain while in vitro studies involved studying the effect of morphine on the uptake of tritiated tyrosine by synaptosomes and its subsequent incorporation into the catecholamines. The extremely low levels of these endogenous compounds required the use of High Performance Liquid Chromatography with electrochemical detection. Intra-peritoneal injection of morphine at a dosage of 10 mg/kg did not produce appreciable changes in the catecholamine levels but a dosage of 30 mg/kg morphine was found to elevate dihydroxy phenylacetic acid content. At a dosage of 60 mg/kg, dopamine levels were elevated while noradrenaline was depleted. Morphine, at a concentration of 1 x 10(-5)M increases the incorporation of tritiated tyrosine into dopamine and dihydroxy phenylacetic acid in synaptosomal preparations.
    Matched MeSH terms: Electrochemistry
  2. Navaratnam V, Mansor SM, Chin LK, Mordi MN, Asokan M, Nair NK
    J Chromatogr B Biomed Appl, 1995 Jul 21;669(2):289-94.
    PMID: 7581905
    A selective reproducible high-performance liquid chromatographic assay for the simultaneous quantitative determination of the antimalarial compound artemether (ARM), dihydroartemisinin (DQHS) and artemisinin (QHS), as internal standard, is described. After extraction from plasma, ARM and DQHS were analysed using a Lichrocart/Lichrosphere 100 CN stainless-steel column and a mobile phase of acetonitrile-0.05 M acetic acid (15:85, v/v) adjusted to pH 5.0, and electrochemical detection in the reductive mode. The mean recovery of ARM and DQHS over a concentration range of 30-120 ng/ml was 81.6% and 93.4%, respectively. The within-day coefficients of variation were 0.89-7.01% for ARM and 3.45-8.11% for DQHS. The day-to-day coefficients of variation were 2.06-8.43% and 3.22-6.33%, respectively. The minimum detectable concentration for ARM and DQHS in plasma was 2.5 and 1.25 ng/ml for both compounds. The method was found to be suitable for use in clinical pharmacological studies.
    Matched MeSH terms: Electrochemistry
  3. Chan KL, Yuen KH, Jinadasa S, Peh KK, Toh WT
    Planta Med, 1997 Feb;63(1):66-9.
    PMID: 9063097
    A high-performance liquid chromatography assay equipped with a glassy carbon electrode for electrochemical detection (HPLC-ECD) was developed at reductive mode for the analysis of artemisinin, the antimalarial drug from Artemisia annua (Asteraceae) in human plasma. This method was selective, sensitive, and produced satisfactory recovery, precision, and accuracy. Analysis of plasma samples from 8 male volunteers given 10 mg kg-1 of artemisinin orally as an aqueous suspension showed a mean peak plasma concentration (Cmax) of 580.89 ng ml-1 +/- 88.64 SD at 2.5 h +/- 0.5 SD after dosing, and the mean area under the plasma concentration-time curve (AUC0-infinity) was 2227.57 ng h ml-1 +/- 677.22 SD. In addition, the elimination rate constant (Ke), elimination half-life (t1/2), and apparent volume of distribution (Vd) were calculated to be 0.2971 h-1 +/- 0.0644 SD, 2.42 h +/- 0.46 SD, and 16.26 l kg-1 +/- 3.44 SD, respectively.
    Matched MeSH terms: Electrochemistry
  4. Hashim OH, Shuib AS, Chua CT
    Nephron, 2001 Dec;89(4):422-5.
    PMID: 11721160
    We have studied the interaction of the Gal-GalNAc-reactive champedak lectin-C with neuraminidase-treated and untreated IgA1 from IgA nephropathy patients. The binding ability of the lectin to untreated IgA1 from IgA nephropathy patients was significantly lower as compared to the untreated IgA1 from normal controls. This differential lectin-binding capacity was abrogated when the experiment was performed on neuraminidase-treated sera. Treatment of the serum IgA1 with neuraminidase also abrogated the differential charge distribution between the alpha-heavy chains of IgA nephropathy patients and normal controls.
    Matched MeSH terms: Electrochemistry
  5. Mohd Asri MT, Elias S, Iskandar SM, Abd Halim S, Jumiah H, Zaki AR, et al.
    Med J Malaysia, 2004 May;59 Suppl B:139-40.
    PMID: 15468857
    The aim of this work was to study radiation and the effects of temperature on conductivity properties of polyvinyl alcohol (PVA)-based potassium hydroxide (KOH) and propylene carbonate (PC), where the ionic conduction preferentially occurs in the amorphous phase by free radicals ions through gamma-irradiation. Alkaline composite polymer electrolyte (ACPE) consisting of PVA, KOH and PC of different concentration ratios were prepared by solvent-casting technique. The ACPE were irradiated with different doses from 5 kGy up to 200 kGy. The conductivity properties of the electrolyte films were measured at different frequencies in the range 20 Hz to 1 MHz using LCR meter. The results showed that the conductivity properties were dependent on the radiation dose, temperature and the concentration of the polymer blends.
    Matched MeSH terms: Electrochemistry
  6. Azila AA, Barbari T, Searson P
    Med J Malaysia, 2004 May;59 Suppl B:51-2.
    PMID: 15468814
    Considerable effort has been focused on the method of immobilizing glucose oxidase (GOD) for amperometric glucose biosensors since the technique employed may influence the available activity of the enzyme and thus affect the performance of the sensor. Narrow measuring range and low current response are still considered problems in this area. In this work, poly(vinyl alcohol)(PVA) was investigated as a potential matrix for GOD immobilization. GOD was entrapped in cross-linked PVA. The use of a PVA-GOD membrane as the enzymatic component of a glucose biosensor was found to be promising in both the magnitude of its signal and its relative stability over time. The optimum PVA-GOD membrane (cross-linking density of 0.06) was obtained through careful selection of the cross-linking density of the PVA matrix.
    Matched MeSH terms: Electrochemistry
  7. Bean LS, Heng LY, Yamin BM, Ahmad M
    Bioelectrochemistry, 2005 Feb;65(2):157-62.
    PMID: 15713567
    A single-step fabrication of a glucose biosensor with simultaneous immobilization of both ferrocene mediator and glucose oxidase in a photocurable methacrylic film consisting of poly(methyl methacrylate-co-2-hydroxylethyl methacrylate) was reported. The entrapped ferrocene showed reversible redox behaviour in the photocured film and no significant leaching of both entrapped ferrocene and enzyme glucose oxidase was observed because of the low water absorption properties of the co-polymer films. From electrochemical studies, ferrocene entrapped in the co-polymer film demonstrated slow diffusion properties. A linear glucose response range of 2-11 mM was obtained at low applied potential of +0.25 V. The glucose biosensor fabricated by this photocuring method yielded sensor reproducibility and repeatability with relative standard deviation of <10% and long-term stability of up to 14 days. The main advantage of the use of photocurable procedure is that biosensor membrane fabrication can be performed in a single step without any lengthy chemical immobilization of enzyme.
    Matched MeSH terms: Electrochemistry*
  8. Zainal Z, Lee CY, Hussein MZ, Kassim A, Yusof NA
    J Hazard Mater, 2005 Feb 14;118(1-3):197-203.
    PMID: 15721544
    Electrochemical-assisted photodegradation of methyl orange has been investigated using TiO2 thin films. The films were prepared by sol-gel dip-coating method. Several operational parameters to achieve optimum efficiency of this electrochemical-assisted photodegradation system have been tested. Photoelectrochemical degradation was studied using different light sources and light intensity. The light sources chosen ranged from ultraviolet to visible light. The effect of agitation of the solution at different speeds has also been studied. Slight improvement of photodegradation rate was observed by applying higher agitation speed. Investigation on the electrode after repeated usages show the electrode can be reused up to 20 times with percentage of deficiency less than 15%. The study on the effect of solution temperature indicated that the activation energy of the methyl orange degradation is 18.63 kJ mol(-1).
    Matched MeSH terms: Electrochemistry
  9. Saad B, Wai WT, Ali AS, Saleh MI
    Anal Sci, 2006 Jan;22(1):45-50.
    PMID: 16429771
    A flow injection analysis (FIA) method for the determination of four residual chlorine species, namely combined available chlorine (CAC), free available chlorine (FAC), total available chlorine (TAC) and chlorite (ClO2-) was developed using a flow-through triiodide-selective electrode as a detector. An important strategy of speciation studies utilized the kinetic discrimination of reactions between the CAC and FAC with Fe2+, which was applied to the speciation of FAC, CAC and TAC. The speciation of available chlorine species and chlorite (an oxychlorine species) was achieved by using the same set-up, but using flow streams of different pH. The effects of the pH of the carrier stream, the flow rate and the sample volume were studied. The method exhibited linearity from 2.8 x 10(-6) to 2.8 x 10(-4) M active chlorine (expressed as OCl-) with a detection limit of 1.4 x 10(-6) M. The selectivity of the method was studied by examining the minimum pH for the oxidation of iodide by other oxidants, and also by assessing the potentiometric selectivity coefficients. The proposed method was successfully applied to the determination of chlorine species in tap water, and disinfecting formulations where good agreement occurred between the proposed and standard methods were found.
    Matched MeSH terms: Electrochemistry/instrumentation; Electrochemistry/methods
  10. Yap CY, Mohamed N
    Chemosphere, 2007 Apr;67(8):1502-10.
    PMID: 17296217
    Traditional methods for the recovery of gold from electronic scrap by hydrometallurgy were cyanidation followed by adsorption on activated carbon or cementation onto zinc dust and by electrowinning. In our studies, a static batch electrochemical reactor operating in an electrogenerative mode was used in gold recovery from cyanide solutions. A spontaneous chemical reaction will take place in the reactor and generate an external flow of current. In this present work, a static batch cell with an improved design using three-dimensional cathodes namely porous graphite and reticulated vitreous carbon (RVC) and two-dimensional cathode materials, copper and stainless steel plates were coupled with a zinc anode. The electrogenerative system was demonstrated and the performance of the system using various cathode materials for gold recovery was evaluated. The system resulted in more than 90% gold being recovered within 3h of operation. Activated RVC serves as a superior cathode material having the highest recovery rate with more than 99% of gold being recovered in 1h of operation. The morphology of gold deposits on various cathode materials was also investigated.
    Matched MeSH terms: Electrochemistry/instrumentation; Electrochemistry/methods*
  11. Pang SC, Chin SF, Anderson MA
    J Colloid Interface Sci, 2007 Jul 1;311(1):94-101.
    PMID: 17395194
    The effect of pH and redox potential on the redox equilibria of iron oxides in aqueous-based magnetite dispersions was investigated. The ionic activities of each dissolved iron species in equilibrium with magnetite nanoparticles were determined and contoured within the Eh-pH framework of a composite stability diagram. Both standard redox potentials and equilibrium constants for all major iron oxide redox equilibria in magnetite dispersions were found to differ from values reported for noncolloidal systems. The "triple point" position of redox equilibrium among Fe(II) ions, magnetite, and hematite shifted to a higher standard redox potential and an equilibrium constant which was several orders of magnitude higher. The predominant area of magnetite stability was enlarged to cover a wider range of both pH and redox potentials as compared to that of a noncolloidal magnetite system.
    Matched MeSH terms: Electrochemistry
  12. Zainal Z, Lee CY, Hussein MZ, Kassim A, Yusof NA
    J Hazard Mater, 2007 Jul 19;146(1-2):73-80.
    PMID: 17196740
    Mixed dye consists of six commercial dyes and textile effluents from cotton dyeing process were treated by electrochemical-assisted photodegradation under halogen lamp illumination. Two types of effluents were collected which are samples before and after undergone pre-treatment at the factory wastewater treatment plant. The photodegradation process was studied by evaluating the changes in concentration employing UV-vis spectrophotometer (UV-vis) and total organic carbon (TOC) analysis. The photoelectrochemical degradation of mixed dye was found to follow the Langmuir Hinshelwood pseudo-first order kinetic while pseudo-second order kinetic model for effluents by using TOC analyses. The chemical oxygen demand (COD) and biochemical oxygen demand (BOD) values of mixed dye and raw effluents were reported. Photoelectrochemical characteristic of pollutants was studied using the cyclic voltammetry technique. Raw effluent was found to exhibit stronger reduction behaviour at cathodic bias potential but slightly less photoresponse at anodic bias than mixed dye.
    Matched MeSH terms: Electrochemistry
  13. Jalil AA, Panjang NF, Akhbar S, Sundang M, Tajuddin N, Triwahyono S
    J Hazard Mater, 2007 Sep 5;148(1-2):1-5.
    PMID: 17669589
    Electrochemical dechlorination of chlorobenzene in organic solutions was studied. Electrolysis of chlorobenzene in acetonitrile solution in a one-compartment cell fitted with a platinum cathode and a zinc anode at 60mA/cm(2) and 0 degrees C was found to be the optimum conditions, which gave complete dechlorination of chlorobenzene. However, similar result could not be achieved when applying these conditions to 1,3-dichlorobenzene and 1,2,4-trichlorobenzene. We found that the use of naphthalene which reacted as a mediator in the appropriate system could accelerate the reduction and gave complete dechlorination of those chlorobenzenes. Moreover, in the presence of naphthalene the reaction time could be shortened by half compared to dechlorination in the absence of naphthalene.
    Matched MeSH terms: Electrochemistry/methods*
  14. Yean CY, Kamarudin B, Ozkan DA, Yin LS, Lalitha P, Ismail A, et al.
    Anal Chem, 2008 Apr 15;80(8):2774-9.
    PMID: 18311943 DOI: 10.1021/ac702333x
    A general purpose enzyme-based amperometric electrochemical genosensor assay was developed wherein polymerase chain reaction (PCR) amplicons labeled with both biotin and fluorescein were detected with peroxidase-conjugated antifluorescein antibody on a screen-printed carbon electrode (SPCE). As a proof of principle, the response selectivity of the genosensor was evaluated using PCR amplicons derived from lolB gene of Vibrio cholerae. Factors affecting immobilization, hybridization, and nonspecific binding were optimized to maximize sensitivity and reduce assay time. On the basis of the background amperometry signals obtained from nonspecific organisms and positive signals obtained from known V. cholerae, a threshold point of 4.20 microA signal was determined as positive. Under the optimum conditions, the limit of detection (LOD) of the assay was 10 CFU/mL of V. cholerae. The overall precision of this assay was good, with the coefficient of variation (CV) being 3.7% using SPCE and intermittent pulse amperometry (IPA) as an electrochemical technique. The assay is sensitive, safe, and cost-effective when compared to conventional agarose gel electrophoresis, real-time PCR, and other enzyme-linked assays for the detection of PCR amplicons. Furthermore, the use of a hand-held portable reader makes it suitable for use in the field.
    Matched MeSH terms: Electrochemistry/methods*
  15. Ghafari S, Hasan M, Aroua MK
    Bioresour Technol, 2008 Jul;99(10):3965-74.
    PMID: 17600700
    Nitrates in different water and wastewater streams raised concerns due to severe impacts on human and animal health. Diverse methods are reported to remove nitrate from water streams which almost fail to entirely treat nitrate, except biological denitrification which is capable of reducing inorganic nitrate compounds to harmless nitrogen gas. Review of numerous studies in biological denitrification of nitrate containing water resources, aquaculture wastewaters and industrial wastewater confirmed the potential of this method and its flexibility towards the remediation of different concentrations of nitrate. The denitrifiers could be fed with organic and inorganic substrates which have different performances and subsequent advantages or disadvantages. Review of heterotrophic and autotrophic denitrifications with different food and energy sources concluded that autotrophic denitrifiers are more effective in denitrification. Autotrophs utilize carbon dioxide and hydrogen as the source of carbon substrate and electron donors, respectively. The application of this method in bio-electro reactors (BERs) has many advantages and is promising. However, this method is not so well established and documented. BERs provide proper environment for simultaneous hydrogen production on cathodes and appropriate consumption by immobilized autotrophs on these cathodes. This survey covers various designs and aspects of BERs and their performances.
    Matched MeSH terms: Electrochemistry/methods*
  16. Aroua MK, Leong SP, Teo LY, Yin CY, Daud WM
    Bioresour Technol, 2008 Sep;99(13):5786-92.
    PMID: 18023577
    In this study, the kinetics of adsorption of Pb(II) from aqueous solution onto palm shell-based activated carbon (PSAC) were investigated by employing ion selective electrode (ISE) for real-time Pb(II) and pH monitoring. Usage of ISE was very appropriate for real-time adsorption kinetics data collection as it facilitated recording of adsorption data at very specific and short time intervals as well as provided consistent kinetics data. Parameters studied were initial Pb(II) concentration and agitation speed. It was found that increases in initial Pb(II) concentration and agitation speed resulted in higher initial rate of adsorption. Pseudo first-order, pseudo second-order, Elovich, intraparticle diffusion and liquid film diffusion models were used to fit the adsorption kinetics data. It was suggested that chemisorption was the rate-controlling step for adsorption of Pb(II) onto PSAC since the adsorption kinetics data fitted both the pseudo second-order and Elovich models well.
    Matched MeSH terms: Electrochemistry/methods
  17. Yap CY, Mohamed N
    Chemosphere, 2008 Oct;73(5):685-91.
    PMID: 18718637 DOI: 10.1016/j.chemosphere.2008.07.014
    An electrogenerative flow-through reactor with an activated reticulated vitreous carbon cathode was developed. The influence of palladium-tin activation of the cathode towards gold deposition was studied by cyclic voltammetry. The reactor proved to be efficient in recovering more than 99% of gold within 4 h of operation. The performance of the reactor was evaluated with initial gold concentrations of 10, 100 and 500 mg L-1 and various electrolyte flow rates. Gold recovery was found to be strongly dependent on electrolyte flow rate and initial gold concentration in the cyanide solution under the experimental conditions used.
    Matched MeSH terms: Electrochemistry/instrumentation; Electrochemistry/methods*
  18. Kam TS, Lim KH
    Alkaloids Chem Biol, 2008;66:1-111.
    PMID: 19025097
    Matched MeSH terms: Electrochemistry/methods
  19. Lai CS, Nair NK, Muniandy A, Mansor SM, Olliaro PL, Navaratnam V
    J Chromatogr B Analyt Technol Biomed Life Sci, 2009 Feb 15;877(5-6):558-62.
    PMID: 19147417 DOI: 10.1016/j.jchromb.2008.12.037
    With the expanded use of the combination of artesunate (AS) and amodiaquine (AQ) for the treatment of falciparum malaria and the abundance of products on the market, comes the need for rapid and reliable bioanalytical methods for the determination of the parent compounds and their metabolites. While the existing methods were developed for the determination of either AS or AQ in biological fluids, the current validated method allows simultaneous extraction and determination of AS and AQ in human plasma. Extraction is carried out on Supelclean LC-18 extraction cartridges where AS, its metabolite dihydroartemisinin (DHA) and the internal standard artemisinin (QHS) are separated from AQ, its metabolite desethylamodiaquine (DeAQ) and the internal standard, an isobutyl analogue of desethylamodiaquine (IB-DeAQ). AS, DHA and QHS are then analysed using Hypersil C4 column with acetonitrile-acetic acid (0.05M adjusted to pH 5.2 with 1.00M NaOH) (42:58, v/v) as mobile phase at flow rate 1.50ml/min. The analytes are detected with an electrochemical detector operating in the reductive mode. Chromatography of AQ, DeAQ and IB-DeAQ is carried out on an Inertsil C4 column with acetonitrile-KH(2)PO(4) (pH 4.0, 0.05M) (11:89, v/v) as mobile phase at flow rate 1.00ml/min. The analytes are detected by an electrochemical detector operating in the oxidative mode. The recoveries of AS, DHA, AQ and DeAQ vary between 79.1% and 104.0% over the concentration range of 50-1400ng/ml plasma. The accuracies of the determination of all the analytes are 96.8-103.9%, while the variation for within-day and day-to-day analysis are <15%. The lower limit of quantification for all the analytes is 20ng/ml and limit of detection is 8ng/ml. The method is sensitive, selective, accurate, reproducible and suited particularly for pharmacokinetic study of AS-AQ drug combination and can also be used to compare the bioavailability of different formulations, including a fixed-dose AS-AQ co-formulation.
    Matched MeSH terms: Electrochemistry/methods*
  20. Hanifah SA, Heng LY, Ahmad M
    Anal Sci, 2009 Jun;25(6):779-84.
    PMID: 19531887
    Electrochemical biosensors for phenolic compound determination were developed by immobilization of tyrosinase enzyme in a series of methacrylic-acrylic based biosensor membranes deposited directly using a photocuring method. By modifying the hydrophilicity of the membranes using different proportions of 2-hydroxyethyl methacrylate (HEMA) and butyl acrylate (nBA), we developed biosensor membranes of different hydrophilic characters. The differences in hydrophilicity of these membranes led to changes in the sensitivity of the biosensors towards different phenolic compounds. In general biosensors constructed from the methacrylic-acrylic based membranes showed the poorest response to catechol relative to other phenolic compounds, which is in contrast to many other biosensors based on tyrosinase. The decrease in hydrophilicity of the membrane also allowed better selectivity towards chlorophenols. However, phenol biosensors constructed from the more hydrophilic membrane materials demonstrated better analytical performance towards phenol compared with those made from less hydrophilic ones. For the detection of phenols, these biosensors with different membranes gave detection limits of 0.13-0.25 microM and linear response range from 6.2-54.2 microM phenol. The phenol biosensors also showed good phenol recovery from landfill leachate samples (82-117%).
    Matched MeSH terms: Electrochemistry
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links