Displaying publications 1 - 20 of 470 in total

Abstract:
Sort:
  1. Nasrulhaq-Boyce A, Mohamed MAH
    New Phytol, 1987 Jan;105(1):81-88.
    PMID: 33874033 DOI: 10.1111/j.1469-8137.1987.tb00112.x
    A comparative study of four Malayan ferns, Christensenia aesculifolia (Bl.) Maxon, Tectaria singaporeana (Wall.) Ching, Abacopteris multilineata (Wall.) Ching and Hymenophyllum polyanthos Sw. from shady habitats and another four, Dicranopteris linearis (Burm.) Und., Lygodium scandens (L.) Sw., Blechnum orientate Linn, and Stenochlaena palustris (Burm.) Bedd. from sunlit habitats showed that the total chlorophyll content expressed on a gram fresh weight basis was greater in the shade ferns. There was little difference in the chlorophyll content between the sun and shade ferns when it was expressed on a per unit leaf area basis. The protein and protohaem content was greater in the sun ferns. Measurements of the in vitro photochemical activities of the photosystems I and II in isolated chloroplasts by means of an oxygen electrode showed higher rates in the sun ferns. As determined by spectrophotometric analysis, the photosynthetic cytochrome content from isolated chloroplasts was greater in the sun ferns. The results indicate that the sun ferns have physiological characteristics favouring greater capacity for photosynthesis. Mitochondria isolated from the sun ferns showed faster rates of electron transport using exogenous NADH as substrate.
    Matched MeSH terms: Electrodes
  2. Tan WT, Tan GS, Nather Khan IS
    Environ Pollut, 1988;52(3):221-35.
    PMID: 15092608
    Chemical forms of copper and lead in river water of the Linggi River Basin have been fractionated into ASV labile, moderately labile, slowly labile, and inert metal species, based on a previously proposed scheme. Free (hydrated) metal ions were identified by a potentiometric method using an ion selective electrode. Speciation results showed that the soluble copper and lead species occurred mainly in the moderately labile and slowly labile fractions. The speciation results are primarily interpreted in terms of organic interaction due to agricultural based and light industries, and urban discharges. The measured metal complexing capacity (MCC) of the samples reveals consistency of the results with the nature of the discharge. MCC correlates reasonably well with the value from the permanganate test on the river water. In general, the speciation pattern was found to be consistent with the findings of other workers.
    Matched MeSH terms: Ion-Selective Electrodes
  3. Saad B, Kanapathy K, Ahmad MN, Hussin AH, Ismail Z
    Talanta, 1991 Dec;38(12):1399-402.
    PMID: 18965315
    Three main types of PVC solvent polymeric membrane ion-selective electrodes for chloroquine are described. They are based on three ion-pairing agents namely dipicrylamine (DPA), tetraphenylborate (TPB) or tetrakis(4-chlorophenyl)borate (TCPB) with either dioctylphenyl phosphonate (DOPP) or trioctyl phosphate (TOP) solvent mediator. All electrodes exhibit Nernstian responses, fast dynamic response times and a wide useful pH range. The best all-round electrode is based on TPB and TOP plasticizing solvent mediators with a limit of detection of 7.1 x 10(-6)M and was utilized for the assay of chloroquine in tablets. Direct potentiometric determinations with either the analyte addition method or the normal calibration method gave results comparable to the official method.
    Matched MeSH terms: Ion-Selective Electrodes
  4. Anuar K, Hamdan S
    Talanta, 1992 Dec;39(12):1653-6.
    PMID: 18965586
    A new lead(II) electrode has been constructed with poly(hydroxamic acid) (PHXA) as the active material and silicone rubber as the supporting material. The electrode gave near Nerstian response over the concentration range 4 x 10(-5)-1 x 10(-2)M lead(II). The detection limit of the electrode is approximately 4 x 10(-6)M and the electrode works well in the pH range 4.5-6.0. The response time was 50-120 sec over the whole concentration range and the electrode has a working life of at least 4 weeks. Iron(III) severely poisoned the electrode membrane. Nickel(II) and mercury(II) gave very strong interference compared to copper(II), silver(I), cobalt(II), sodium(I), potassium(I), zinc(II) and cadmium(II) which gave some or little interference. Values determined with atomic absorption (AAS) and a commercial lead(II) electrode were in good agreement with those measured with the lead(II) electrode reported here.
    Matched MeSH terms: Electrodes
  5. Chan KL, Yuen KH, Jinadasa S, Peh KK, Toh WT
    Planta Med, 1997 Feb;63(1):66-9.
    PMID: 9063097
    A high-performance liquid chromatography assay equipped with a glassy carbon electrode for electrochemical detection (HPLC-ECD) was developed at reductive mode for the analysis of artemisinin, the antimalarial drug from Artemisia annua (Asteraceae) in human plasma. This method was selective, sensitive, and produced satisfactory recovery, precision, and accuracy. Analysis of plasma samples from 8 male volunteers given 10 mg kg-1 of artemisinin orally as an aqueous suspension showed a mean peak plasma concentration (Cmax) of 580.89 ng ml-1 +/- 88.64 SD at 2.5 h +/- 0.5 SD after dosing, and the mean area under the plasma concentration-time curve (AUC0-infinity) was 2227.57 ng h ml-1 +/- 677.22 SD. In addition, the elimination rate constant (Ke), elimination half-life (t1/2), and apparent volume of distribution (Vd) were calculated to be 0.2971 h-1 +/- 0.0644 SD, 2.42 h +/- 0.46 SD, and 16.26 l kg-1 +/- 3.44 SD, respectively.
    Matched MeSH terms: Electrodes
  6. Ling, Booi Cie
    Ann Dent, 1997;4(1):-.
    MyJurnal
    The construction of an electrical pain stimulator was described.
    The parameters of pulse width and frequency on the quality of
    pain stimulation was determined. The best design and construction
    of the electrode for the stimulator was produced.
    Matched MeSH terms: Electrodes
  7. Muda NE, Abu Bakar MA, Majlis BY
    Malays J Med Sci, 1999 Jul;6(2):12-6.
    PMID: 22589683 MyJurnal
    The development of antibody-based biosensor has grown steadily during recent years, and their use as a routine instrument in clinical application is not far from reality. This study has demonstrated the capability of conductometric sensor to quantitate human Follicle Stimulating Hormone (hFSH) from urine samples. The principles are adopted from Enzyme Linked Immunosorbent Assay (ELISA) technique. Self fabricated gold coated electrode was dipped in the microtiter well containing antibody-antigen complex. Substrate was added to the system to initiate a secondary reaction, which produced electroactive species and change the conductivity of the solution. The changes were proportional with the concentration of the hormone present. The results obtained correlate well with the conventional ELISA technique. Inter and intra assay variation (%CV) were under 6% and the lowest detection limit is 0.75 mIU/ml which was well under the physiological range of the hormone. This system offered advantages such as simplicity, reliability, minimal addition of reagents, freedom from turbidity and color problem, probability of miniaturizing the electrode thus minimizing the sample volume and the ability of on line data analysis. This study proved that Antigen-Antibody reaction via EIA could be detected electronically and it has a potential to be used as one of the measuring mode in clinical analysis.
    Matched MeSH terms: Electrodes
  8. Harba MI, Teng LY
    Front Med Biol Eng, 1999;9(1):31-47.
    PMID: 10354908
    Cross-correlating two surface EMG signals detected at two different locations along the path of flow of action potential enables the measurement of the muscle fiber average conduction velocity in those active motor units monitored by the electrodes. The position of the peak of the cross-correlation function is the time delay between the two signals and hence the velocity may be deduced. The estimated velocity using this technique has been observed previously to depend on the location of the electrodes on the muscle surface. Different locations produced different estimates. In this paper we present a measurement system, analyze its inherent inaccuracies and use it for the purpose of investigating the reliability of measurement of conduction velocity from surface EMG. This system utilizes EMG signals detected at a number of locations on the biceps brachii, when under light tension, to look for any pattern of variations of velocity as a function of location and time. It consists of a multi-electrode unit and a set of eight parallel on-line correlators. The electrode unit and the parallel correlators ensure that these measurements are carried out under the same physical and physiological conditions of the muscle. Further, the same detected signals are used in different measurement configurations to try to understand the reasons behind the observed variations in the estimated velocity. The results obtained seem to suggest that there will always be an unpredictable random component superimposed on the estimated velocity, giving rise to differences between estimates at different locations and differences in estimates with time at the same location. Many factors contribute to this random component, such as the non-homogeneous medium between the muscle fibers and the electrodes, the non-parallel geometry and non-uniform conduction velocity of the fibers, and the physical and physiological conditions of the muscle. While it is not possible to remove this random component completely from the measurement, the user must be aware of its presence and how to reduce its effects.
    Matched MeSH terms: Electrodes
  9. Saad B, Bee-Leng Y, Saleh MI, Rahman IA, Mansor SM
    J AOAC Int, 2001 8 15;84(4):1151-7.
    PMID: 11501917
    Potentiometric response characteristics were evaluated for quinine selective sensors based on a lipophilic ion-exchanger potassium tetrakis[3,5-bis(trifluoromethylphenyl)]borate (PTFB) immobilized together with plasticizing solvents in polyvinyl chloride membranes. The use of dioctyl phthalate (DOP), 2-nitrophenyl phenyl ether (NPPE), and bis(2-ethylhexyl)adipate (BEHA) plasticizers produced good quality quinine sensors that were sensitive and fast responding, and exhibited near Nernstian responses when used as batch-sensors. These membranes were further tested in a wall-jet flow-through potentiometric flow injection analysis (FIA) detector. Quinine sensors containing BEHA were the most suitable membrane, with no noticeable differences in sensitivity even after 5 h of continuous exposure to solutions. Interference by foreign species such as alkali, alkaline earth metal ions, sugars, and sodium benzoate was minimal in either the batch-mode (log selectivity coefficients
    Matched MeSH terms: Electrodes
  10. Ahmed AM, Sulaiman WN
    Environ Manage, 2001 Nov;28(5):655-63.
    PMID: 11568845
    Landfills are sources of groundwater and soil pollution due to the production of leachate and its migration through refuse. This study was conducted in order to determine the extent of groundwater and soil pollution within and around the landfill of Seri Petaling located in the State of Selangor, Malaysia. The condition of nearby surface water was also determined. An electrical resistivity imaging survey was used to investigate the leachate production within the landfill. Groundwater geochemistry was carried out and chemical analysis of water samples was conducted upstream and downstream of the landfill. Surface water was also analyzed in order to determine its quality. Soil chemical analysis was performed on soil samples taken from different locations within and around the landfill in the vadose zone (unsaturated zone) and below the water table (in the soil saturated zone). The resistivity image along line L-L1 indicated the presence of large zones of decomposed waste bodies saturated with highly conducting leachate. Analysis of trace elements indicated their presence in very low concentrations and did not reflect any sign of heavy metal pollution of ground and surface water or of soil. Major ions represented by Na, K, and Cl were found in anomalous concentrations in the groundwater of the downstream bore hole, where they are 99.1%, 99.2%, and 99.4%, respectively, higher compared to the upstream bore hole. Electrical conductivity (EC) was also found in anomalous concentration downstream. Ca and Mg ions represent the water hardness (which is comparatively high downstream). There is a general trend of pollution towards the downstream area. Sulfates (SO4) and nitrates (NO3) are found in the area in low concentrations, even below the WHO standards for drinking water, but are significantly higher in the surface water compared to the groundwater. Phosphate (PO4) and nitrite (NO2), although present in low levels, are significantly higher at the downstream. There is no significant difference in the amount of fluoride (F) in the different locations. In the soil vadose zone, heavy metals were found to be in their typical normal ranges and within the background concentrations. Soil exchangeable bases were significantly higher in the soil saturated zone compared to the vadose zone, and no significant difference was obtained in the levels of inorganic pollutants. With the exception of Cd, the concentration ranges of all trace elements (Cu, Zn, Cr, Pb, and Ni) of Seri Petaling landfill soils were below the upper limits of baseline concentrations published from different sources.
    Matched MeSH terms: Electrodes
  11. Lim CP, Quek SS, Peh KK
    J Pharm Biomed Anal, 2003 Feb 05;31(1):159-68.
    PMID: 12560060
    This paper investigates the use of a neural-network-based intelligent learning system for the prediction of drug release profiles. An experimental study in transdermal iontophoresis (TI) is employed to evaluate the applicability of a particular neural network (NN) model, i.e. the Gaussian mixture model (GMM), in modeling and predicting drug release profiles. A number of tests are systematically designed using the face-centered central composite design (CCD) approach to examine the effects of various process variables simultaneously during the iontophoresis process. The GMM is then applied to model and predict the drug release profiles based on the data samples collected from the experiments. The GMM results are compared with those from multiple regression models. In addition, the bootstrap method is used to assess the reliability of the network predictions by estimating confidence intervals associated with the results. The results demonstrate that the combination of the face-centered CCD and GMM can be employed as a useful intelligent tool for the prediction of time-series profiles in pharmaceutical and biomedical experiments.
    Matched MeSH terms: Electrodes
  12. Bean LS, Heng LY, Yamin BM, Ahmad M
    Bioelectrochemistry, 2005 Feb;65(2):157-62.
    PMID: 15713567
    A single-step fabrication of a glucose biosensor with simultaneous immobilization of both ferrocene mediator and glucose oxidase in a photocurable methacrylic film consisting of poly(methyl methacrylate-co-2-hydroxylethyl methacrylate) was reported. The entrapped ferrocene showed reversible redox behaviour in the photocured film and no significant leaching of both entrapped ferrocene and enzyme glucose oxidase was observed because of the low water absorption properties of the co-polymer films. From electrochemical studies, ferrocene entrapped in the co-polymer film demonstrated slow diffusion properties. A linear glucose response range of 2-11 mM was obtained at low applied potential of +0.25 V. The glucose biosensor fabricated by this photocuring method yielded sensor reproducibility and repeatability with relative standard deviation of <10% and long-term stability of up to 14 days. The main advantage of the use of photocurable procedure is that biosensor membrane fabrication can be performed in a single step without any lengthy chemical immobilization of enzyme.
    Matched MeSH terms: Electrodes
  13. Saad B, Zin ZM, Jab MS, Rahman IA, Saleh MI, Mahsufi S
    Anal Sci, 2005 May;21(5):521-4.
    PMID: 15913140
    Poly (vinyl chloride) membrane electrodes that responded selectively towards the antimalarial drug chloroquine are described. The electrodes were based on the use of the lipophilic potassium tetrakis(4-chlorophenyl)borate as ion-exchanger and bis(2-ethylhexyl)adipate (BEHA), or trioctylphosphate (TOP) or dioctylphenylphosphonate (DOPP) as plasticizing solvent mediator. All electrodes produced good quality characteristics such as Nernstian- and rapid responses, and are minimally interfered with by the alkali and alkaline earth metal ions tested. The membranes were next applied to a flow-through device, enabling it to function as flow-injection analysis (FIA) detector. The performance of the sensor after undergoing the FIA optimization was further evaluated for its selectivity characteristics and lifetime. Results for the determination of chloroquine in synthetic samples that contained common tablet excipients such as glucose, starch, and cellulose, and other foreign species such as cations, citric acid or lactic acid were generally satisfactory. The sensor was also successfully used for the determination of the active ingredients in mock tablets, synthetic fluids and biological fluids. The sensor was applied for the determination of active ingredients and the dissolution profile of commercial tablets was also established.
    Matched MeSH terms: Electrodes
  14. Saad B, Wai WT, Ali AS, Saleh MI
    Anal Sci, 2006 Jan;22(1):45-50.
    PMID: 16429771
    A flow injection analysis (FIA) method for the determination of four residual chlorine species, namely combined available chlorine (CAC), free available chlorine (FAC), total available chlorine (TAC) and chlorite (ClO2-) was developed using a flow-through triiodide-selective electrode as a detector. An important strategy of speciation studies utilized the kinetic discrimination of reactions between the CAC and FAC with Fe2+, which was applied to the speciation of FAC, CAC and TAC. The speciation of available chlorine species and chlorite (an oxychlorine species) was achieved by using the same set-up, but using flow streams of different pH. The effects of the pH of the carrier stream, the flow rate and the sample volume were studied. The method exhibited linearity from 2.8 x 10(-6) to 2.8 x 10(-4) M active chlorine (expressed as OCl-) with a detection limit of 1.4 x 10(-6) M. The selectivity of the method was studied by examining the minimum pH for the oxidation of iodide by other oxidants, and also by assessing the potentiometric selectivity coefficients. The proposed method was successfully applied to the determination of chlorine species in tap water, and disinfecting formulations where good agreement occurred between the proposed and standard methods were found.
    Matched MeSH terms: Electrodes
  15. Winie T, Arof AK
    Spectrochim Acta A Mol Biomol Spectrosc, 2006 Mar 1;63(3):677-84.
    PMID: 16157506
    Fourier transform infrared (FT-IR) spectroscopic studies have been undertaken to investigate the interactions among components in a system of hexanoyl chitosan-lithium trifluoromethanesulfonate (LiCF(3)SO(3))-diethyl carbonate (DEC)/ethylene carbonate (EC). LiCF(3)SO(3) interacts with the hexanoyl chitosan to form a hexanoyl chitosan-salt complex that results in the shifting of the N(COR)(2), CONHR and OCOR bands to lower wavenumbers. Interactions between EC and DEC with LiCF(3)SO(3) has been noted and discussed. Evidence of interaction between EC and DEC has been obtained experimentally. Studies on polymer-plasticizer spectra suggested that there is no interaction between the polymer host and plasticizers. Competition between plasticizer and polymer on associating with Li(+) ions was observed from the spectral data for gel polymer electrolytes. The obtained spectroscopic data has been correlated with the conductivity performance of hexanoyl chitosan-based polymer electrolytes.
    Matched MeSH terms: Electrodes*
  16. Ariffin Z, Ngo H, McIntyre J
    Aust Dent J, 2006 Dec;51(4):328-32.
    PMID: 17256308
    BACKGROUND: This study investigated the extent to which a coating of 10% silver fluoride (AgF) on discs of glass jonomer cements (GIGs) would enhance the release of fluoride ion into eluting solutions at varying pH.

    MATERIALS AND METHODS: Forty discs each of Fuji LX, Fuji VII and of Vitrebond were prepared in a plastic mould. Twenty discs of each material were coated for 30 seconds with a 10% solution of AgF. Five discs each of coated and uncoated material were placed individually in 4m1 of differing eluant solutions. The eluant solutions comprised deionized distilled water (DDW) and three separate acetate buffered solutions at pH 7, pH 5 and pH 3. After 30 minutes the discs were removed and placed in five vials containing 4m1 of the various solutions for a further 30 minutes. This was repeated for further intervals of time up to 216 hours, and all eluant solutions were stored. Fluoride concentrations in the eluant solutions were estimated using a fluoride specific electrode, with TISAB IV as a metal ion complexing and ionic concentration adjustment agent. Cumulative fluoride release patterns were determined from the incremental data.

    RESULTS: The coating of AgF greatly enhanced the level of fluoride ion release from all materials tested. Of the uncoated samples, Vitrehond released the greater concentrations of fluoride ion, followed by Fuji VII. However, cumulative levels of fluoride released from coated samples of the GICs almost matched those from coated Vitrebond.

    CONCLUSIONS: It was concluded that a coating of 10% AgF on GICs and a resin modified GIC greatly enhanced the concentration of fluoride released from these materials. This finding might be applied to improving protection against recurrent caries, particularly in high caries risk patients, and in the atraumatic restorative technique (ART) of restoration placement.

    Matched MeSH terms: Ion-Selective Electrodes
  17. Md Fuad Bahari, Abdul Rahman Omar1, Darius Gnanaraj Solomon, Nor Hayati Saad, Isa Halim
    Scientific Research Journal, 2006;3(2):31-44.
    MyJurnal
    Occupational health is considered as a crucial element in almost every Small
    and Medium Industries (SMIs) and it is believed to be one of vital challenges
    that can influence productivity and competitiveness. It has been known that
    the metal stamping industry involved a lot of materials handling tasks such as
    carrying stamped parts from machine to packaging section, transferring moulds
    from tools store to machines, sorting the finished products and others.
    Appropriate materials handling equipments are not often provided in SMIs
    because of the limitation of capital and lack of ergonomics awareness. The
    workers have to handle the materials and goods manually. These practices
    may lead to occupational injuries particularly back pain and musculoskeletal
    injuries. The objectives of the research are to assess and analyze the muscles
    activity of workers in metal stamping industry. Three male workers who
    performed metal stamping process using manual technique were participated
    in the research. Ergonomic assessment associated with Surface
    Electromyography (SEMG) was used to capture and interpret the data related
    to muscles activity at before and after the ergonomic intervention. For the
    purpose of muscle activity assessment, SEMG electrodes were attached to eight
    critical muscles: deltoid muscle-medial part (left), deltoid muscle-medial part
    (right), trapezius muscle (left), trapezius muscle (right), erector spinae muscle
    (left), erector spinae muscle (right), gastrocnemius muscle (left) and
    Matched MeSH terms: Electrodes
  18. Abdullah, A., Shaharudin, M.H., Amin, M., Marhaban, J.A., Awang, M.A., Zulfiqar, M.A., et al.
    Medicine & Health, 2006;1(1):61-66.
    MyJurnal
    Evidence of ossification was previously considered a relative contraindication to cochlear implantation. It was considered difficult or impossible to achieve safe electrode insertion because of bony obstruction. Either the electrodes or the inner ear structures could be damaged. Moreover, obstructed scala tympani could limit the number of electrodes that can be inserted. The efficacy of the electrical stimulation was also questioned, as a higher current would be needed on an ossified cochlea. Finally, the neural survival in ossified cochlea is unknown. This may complicate the surgical procedure and affect the long-term outcome. However, depending on the experience of the surgeon, cochlear implantation has been attempted even in grossly ossified cochlea. Here we illustrate that cochlear implantation is safe in labyrinthitis ossificans.
    Matched MeSH terms: Electrodes, Implanted
  19. Muhamad Daud, Sarimah Mahat, Mohd Sharif Sattar
    MyJurnal
    Surface free energies have been evaluated from Young’s moduli and lattice parameter data of five aluminium alloys with varying amounts of stanum to determine the inter-correlation with anode capacity of the alloys. The composition containing ~1.47%Sn exhibits a minimum in the surface free energy which accounts for the decrease in the tendency of the alloy to undergo passivation thus resulting in a higher anode capacity of 2478Ah/kg at ≈ 0.08mA/cm 2 , current density. The results showed that aluminium alloy containing certain amount of stanum has lowered surface free energy, leading to reduction in passive film thickness and reduces metal/oxide bond strength. These factors in turn result in a better cathodic protection property of aluminium alloy containing stanum.
    Matched MeSH terms: Electrodes
  20. Isa IM, Ab Ghani S
    Talanta, 2007 Jan 15;71(1):452-5.
    PMID: 19071326 DOI: 10.1016/j.talanta.2006.04.034
    This paper describes the preparation of and experimentation undertaken by heterogeneous chitosan membrane as ion selective electrode for glutamate ion. The linearity response was obtained in the range of 1.0x10(-5) to 1.0x10(-1)M with a detection limit of 1.0x10(-6)M. The performance of the electrode was found in the pH range of 4.0-8.0 at temperature 25+/-3 degrees C. The response time was at 5-35s and was useful for a period of more than 4 months. The selectivity values towards some anions indicates good selectivity over a number of interfering anions. No significant improvement of membrane performance over additional of plasticizers such as 2-NPOE, BEHA and DOPP. The electrodes gave sufficient Nernstian responses with the exception of membrane with 2-NPOE.
    Matched MeSH terms: Ion-Selective Electrodes
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links