Displaying publications 1 - 20 of 118 in total

Abstract:
Sort:
  1. Zakaria A, Shakaff AY, Masnan MJ, Ahmad MN, Adom AH, Jaafar MN, et al.
    Sensors (Basel), 2011;11(8):7799-822.
    PMID: 22164046 DOI: 10.3390/s110807799
    The major compounds in honey are carbohydrates such as monosaccharides and disaccharides. The same compounds are found in cane-sugar concentrates. Unfortunately when sugar concentrate is added to honey, laboratory assessments are found to be ineffective in detecting this adulteration. Unlike tracing heavy metals in honey, sugar adulterated honey is much trickier and harder to detect, and traditionally it has been very challenging to come up with a suitable method to prove the presence of adulterants in honey products. This paper proposes a combination of array sensing and multi-modality sensor fusion that can effectively discriminate the samples not only based on the compounds present in the sample but also mimic the way humans perceive flavours and aromas. Conversely, analytical instruments are based on chemical separations which may alter the properties of the volatiles or flavours of a particular honey. The present work is focused on classifying 18 samples of different honeys, sugar syrups and adulterated samples using data fusion of electronic nose (e-nose) and electronic tongue (e-tongue) measurements. Each group of samples was evaluated separately by the e-nose and e-tongue. Principal Component Analysis (PCA) and Linear Discriminant Analysis (LDA) were able to separately discriminate monofloral honey from sugar syrup, and polyfloral honey from sugar and adulterated samples using the e-nose and e-tongue. The e-nose was observed to give better separation compared to e-tongue assessment, particularly when LDA was applied. However, when all samples were combined in one classification analysis, neither PCA nor LDA were able to discriminate between honeys of different floral origins, sugar syrup and adulterated samples. By applying a sensor fusion technique, the classification for the 18 different samples was improved. Significant improvement was observed using PCA, while LDA not only improved the discrimination but also gave better classification. An improvement in performance was also observed using a Probabilistic Neural Network classifier when the e-nose and e-tongue data were fused.
    Matched MeSH terms: Electronics
  2. Khatir NM, Abdul-Malek Z, Banihashemian SM
    Sensors (Basel), 2014;14(10):19229-41.
    PMID: 25320908 DOI: 10.3390/s141019229
    The fabrication of Metal-DNA-Metal (MDM) structure-based high sensitivity sensors from DNA micro-and nanoarray strands is a key issue in their development. The tunable semiconducting response of DNA in the presence of external electromagnetic and thermal fields is a gift for molecular electronics. The impact of temperatures (25-55 °C) and magnetic fields (0-1200 mT) on the current-voltage (I-V) features of Au-DNA-Au (GDG) structures with an optimum gap of 10 μm is reported. The I-V characteristics acquired in the presence and absence of magnetic fields demonstrated the semiconducting diode nature of DNA in GDG structures with high temperature sensitivity. The saturation current in the absence of magnetic field was found to increase sharply with the increase of temperature up to 45 °C and decrease rapidly thereafter. This increase was attributed to the temperature-assisted conversion of double bonds into single bond in DNA structures. Furthermore, the potential barrier height and Richardson constant for all the structures increased steadily with the increase of external magnetic field irrespective of temperature variations. Our observation on magnetic field and temperature sensitivity of I-V response in GDG sandwiches may contribute towards the development of DNA-based magnetic sensors.
    Matched MeSH terms: Electronics
  3. Bhuiyan MS, Choudhury IA, Dahari M
    Biol Cybern, 2015 Apr;109(2):141-62.
    PMID: 25491411 DOI: 10.1007/s00422-014-0635-1
    Development of an advanced control system for prostheses (artificial limbs) is necessary to provide functionality, effectiveness, and preferably the feeling of a sound living limb. The development of the control system has introduced varieties of control strategies depending on the application. This paper reviews some control systems used for prosthetics, orthotics, and exoskeletons. The advantages and limitations of different control systems for particular applications have been discussed and presented in a comparative manner to help in deciding the appropriate method for pertinent application.
    Matched MeSH terms: Electronics, Medical
  4. Yung LC, Fei CC, Mandeep J, Binti Abdullah H, Wee LK
    PLoS One, 2014;9(5):e97484.
    PMID: 24830317 DOI: 10.1371/journal.pone.0097484
    The success of printing technology in the electronics industry primarily depends on the availability of metal printing ink. Various types of commercially available metal ink are widely used in different industries such as the solar cell, radio frequency identification (RFID) and light emitting diode (LED) industries, with limited usage in semiconductor packaging. The use of printed ink in semiconductor IC packaging is limited by several factors such as poor electrical performance and mechanical strength. Poor adhesion of the printed metal track to the epoxy molding compound is another critical factor that has caused a decline in interest in the application of printing technology to the semiconductor industry. In this study, two different groups of adhesion promoters, based on metal and polymer groups, were used to promote adhesion between the printed ink and the epoxy molding substrate. The experimental data show that silver ink with a metal oxide adhesion promoter adheres better than silver ink with a polymer adhesion promoter. This result can be explained by the hydroxyl bonding between the metal oxide promoter and the silane grouping agent on the epoxy substrate, which contributes a greater adhesion strength compared to the polymer adhesion promoter. Hypotheses of the physical and chemical functions of both adhesion promoters are described in detail.
    Matched MeSH terms: Electronics
  5. Ahamed NU, Sundaraj K, Poo TS
    Proc Inst Mech Eng H, 2013 Mar;227(3):262-74.
    PMID: 23662342
    This article describes the design of a robust, inexpensive, easy-to-use, small, and portable online electromyography acquisition system for monitoring electromyography signals during rehabilitation. This single-channel (one-muscle) system was connected via the universal serial bus port to a programmable Windows operating system handheld tablet personal computer for storage and analysis of the data by the end user. The raw electromyography signals were amplified in order to convert them to an observable scale. The inherent noise of 50 Hz (Malaysia) from power lines electromagnetic interference was then eliminated using a single-hybrid IC notch filter. These signals were sampled by a signal processing module and converted into 24-bit digital data. An algorithm was developed and programmed to transmit the digital data to the computer, where it was reassembled and displayed in the computer using software. Finally, the following device was furnished with the graphical user interface to display the online muscle strength streaming signal in a handheld tablet personal computer. This battery-operated system was tested on the biceps brachii muscles of 20 healthy subjects, and the results were compared to those obtained with a commercial single-channel (one-muscle) electromyography acquisition system. The results obtained using the developed device when compared to those obtained from a commercially available physiological signal monitoring system for activities involving muscle contractions were found to be comparable (the comparison of various statistical parameters) between male and female subjects. In addition, the key advantage of this developed system over the conventional desktop personal computer-based acquisition systems is its portability due to the use of a tablet personal computer in which the results are accessible graphically as well as stored in text (comma-separated value) form.
    Matched MeSH terms: Electronics, Medical
  6. Chee HL, Rashidah S, Shamsuddin K, Sharifah Zainiyah SY
    Med J Malaysia, 2003 Aug;58(3):320-9.
    PMID: 14750370
    A total of 486 Malaysian women electronics workers participated in a study of reproductive health knowledge and cancer screening. The practice of Breast Self Examination (BSE) was found to be related to educational attainment; while ever having had a Pap smear was found to be related to being older than 30 years old, being ever married, living with family or relatives, and not staying in hostels. Knowledge on reproductive health was found to be higher for older women, married women, living with family or relatives, not staying in hostels, ever having done BSE and ever having had a Pap smear.
    Matched MeSH terms: Electronics
  7. Tran L, Radwan I, Minh LHN, Low SK, Hashan MR, Gomaa MD, et al.
    Acta Trop, 2021 Jan 06.
    PMID: 33421421 DOI: 10.1016/j.actatropica.2021.105823
    BACKGROUND AND OBJECTIVES: Modulation of the immune reaction is essential in the development of various diseases, including dengue's "Cytokine Tsunami", an increase in vascular permeability with concomitant severe vascular leakage. We aim to identify the role of T-helper (Th) cells, Th2 and Th7, with their related cytokines in dengue pathogenesis.

    MATERIAL AND METHODS: Nine electronic databases and manual search were applied to detect available publications. A meta-analysis using a fixed- or random-effect model was performed to measure standardized mean difference (SMD) with 95% confidence interval (CI). The National Institute of Health (NIH) tools for observational cohort, cross-sectional, and case-control studies were used to examine the risk of bias. The protocol was recorded in PROSPERO with CRD42017060230.

    RESULTS: A total of 38 articles were found including 19 case-control, 11 cross-sectional and 8 prospective cohort studies. We indicated that Th2 cytokines (IL-4, IL-6, IL-8) and Th17 cytokine (IL-17) in dengue patients were notably higher than in a healthy control group in acute phase (SMD = 1.59, 95% CI [0.68, 2.51], p = 0.001; SMD = 1.24, 95% CI [0.41, 2.06], p = 0.003; SMD = 1.13, 95% CI [0.61, 1.66], p<0.0001; SMD = 1.74, 95% CI [0.87, 2.61], p<0.0001), respectively.

    CONCLUSIONS: This study provides evidence of the significant roles of IL-4, IL-6, IL-8, IL-10 and IL-17 in the pathogenesis of developing a severe reaction in dengue fever. However, to fully determine the association of Th cytokines with dengue, it is necessary to perform further studies to assess kinetic levels during the duration of the illness.

    Matched MeSH terms: Electronics
  8. Nurjuliana M, Che Man YB, Mat Hashim D, Mohamed AK
    Meat Sci, 2011 Aug;88(4):638-44.
    PMID: 21420795 DOI: 10.1016/j.meatsci.2011.02.022
    The volatile compounds of pork, other meats and meat products were studied using an electronic nose and gas chromatography mass spectrometer with headspace analyzer (GCMS-HS) for halal verification. The zNose™ was successfully employed for identification and differentiation of pork and pork sausages from beef, mutton and chicken meats and sausages which were achieved using a visual odor pattern called VaporPrint™, derived from the frequency of the surface acoustic wave (SAW) detector of the electronic nose. GCMS-HS was employed to separate and analyze the headspace gasses from samples into peaks corresponding to individual compounds for the purpose of identification. Principal component analysis (PCA) was applied for data interpretation. Analysis by PCA was able to cluster and discriminate pork from other types of meats and sausages. It was shown that PCA could provide a good separation of the samples with 67% of the total variance accounted by PC1.
    Matched MeSH terms: Electronics
  9. May Honey Ohn
    MyJurnal
    This systematic review was aimed to evaluate the effectiveness of technology-enhanced learning (TEL) used in medical teaching for undergraduate medical students. The objectives are to (a) identify various teaching modalities which are used to enhance TEL; (b) evaluate whether TEL is more effective than traditional learning (TL) in cognitive and affective learning domain outcome. The empirical studies were searched in the following databases: Google Scholar, MEDLINE, ERIC, ProQuest, Cochrane Library and Scopus. All papers published from 2008 to 2018 were included. From eligible studies, the study design, study field, study population, intervention methods, type of assessment and learning achievement were abstracted and summarized the information. The search results were independently reviewed by two authors. From a pool of 1384 articles, 43 eligible articles were identified, enrolling 7292 undergraduate medical students examining comparative study between TEL and traditional learning. The results showed that there was a high degree of heterogeneity seen amongst the included studies in terms of TEL modalities used. The majority of intervention studies favoured online resources, while the rest used various offline multimedia electronic devices, virtual simulations and blended modes. Overall findings showed promising data that TEL is better than TL with regards to knowledge gain and skill acquisition, as well as providing higher student satisfaction. In all, the findings present blended learning in a positive and promising light in time, particularly where systematic reviews on technology-enhanced learning in the field of the undergraduate medical programme have produced mixed result.REVIEW ARTICLEA Systematic Literature Review on Technology-Enhanced Learning in Medical EducationMay Honey Ohn1*, Bareth Ravindran2, Chan Zhi Wei3, Khin Maung Ohn4, Ng Pey Luen5Borneo Journal of Medical Sciences 14 (1) January, 2020: 3 – 171 Emergency Department, Sandwell & West Birmingham NHS Trust, United Kingdom2 Surgical Department, Hospital Tuanku Ja’afar Seremban, Kuala Lumpur, Malaysia3 Orthopaedics Department, Hospital Sungai Buloh, Kuala Lumpur, Malaysia4 Department of Surgery, Faculty of Medicine and Health Sciences, Universiti Malaysia Sabah, Kota Kinabalu, Sabah, Malaysia5 Radiology Department, Hospital Queen Elizabeth II, Sabah, Malaysia* Corresponding author’s email: mayhoney.ohn@gmail.com Received: 14 July 2019 Accepted: 5 November 2019Borneo Journal of Medical SciencesBJMSKeywords: blended learning, technology-enhanced learning, medical education, hybrid learning, undergraduate medical students
    Matched MeSH terms: Electronics
  10. Sun C, Zhang X, Lee WG, Tu Y, Li H, Cai X, et al.
    J Orthop Surg Res, 2020 Aug 05;15(1):297.
    PMID: 32758250 DOI: 10.1186/s13018-020-01823-2
    BACKGROUND: The infrapatellar fat pad (IPFP) or Hoffa's fat pad is often resected during total knee arthroplasty in order to improve visibility. However, the management of the IPFP during total knee arthroplasty (TKA) is the subject of an ongoing debate that has no clear consensus. The purpose of this review was to appraise if resection of the IPFP affects clinical outcomes.

    METHODS: We conducted a meta-analysis to identify relevant randomized controlled trials involving infrapatellar fat pad resection and infrapatellar fat pad preservation during total knee arthroplasty in electronic databases, including Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database, up to March 2020.

    RESULTS: Nine randomized controlled trials, involving 783 TKAs (722 patients), were included in the systematic review. Outcome measures included patellar tendon length (PTL), Insall-Salvati ratio (ISR), rate of anterior knee pain, Knee Society Scores (KSS), and knee range of motion. The meta-analysis identified a trend toward the shortening of the patellar tendon with IPFP resection at 6 months (P = 0.0001) and 1 year (P = 0.001). We found no statistical difference in ISR (P = 0.87), rate of anterior knee pain within 6 months (p = 0.45) and 1 year (p = 0.38), KSS at 1 year (p = 0.77), and knee range of motion within 6 months (p = 0.61) and 1 year (0.46).

    CONCLUSION: Based on the available level I evidence, we were unable to conclude that one surgical technique of IPFP can definitively be considered superior over the other. More adequately powered and better-designed randomized controlled trial (RCT) studies with long-term follow-up are required to produce evidence-based guidelines regarding IPFP resection.

    Matched MeSH terms: Electronics
  11. Irekeola AA, Shueb RH, E A R ENS, Wada Y, Abdul Rahman Z, Ahmad S, et al.
    Cancers (Basel), 2021 Apr 14;13(8).
    PMID: 33919987 DOI: 10.3390/cancers13081886
    For more than 50 years, nasopharyngeal carcinoma (NPC) has been associated with dermatomyositis (DM), a rare idiopathic inflammatory disorder that mainly affects the skin and muscles. Although the association between these rare diseases is well-documented, the actual prevalence of NPC in DM patients remains unknown. Here, a systematic review and meta-analysis of published data was conducted in accordance with the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). Electronic databases including PubMed, Scopus, ScienceDirect, and Google Scholar were searched without year or language restrictions for studies reporting the occurrence of NPC in DM patients. The study protocol was lodged with PROSPERO (CRD42021225335). A total of 95 studies covering 303 cases of NPC among 16,010 DM patients was included. Summary estimates were calculated using the random-effects model. The pooled prevalence of NPC in DM was 3.3% (95% CI, 2.5-4.3). When stratified according to study location, higher prevalence estimates were obtained for Hong Kong (36.5%), Malaysia (27.7%), and Singapore (11.9%). There was a predominance of cases among male DM patients compared with females, and most patients were aged 40 and above. Many of the NPC cases were found to be diagnosed after the diagnosis of DM. It is therefore pertinent to screen for NPC in DM patients, especially among older DM patients in the Asian region.
    Matched MeSH terms: Electronics
  12. Lim XY, Tan TYC, Muhd Rosli SH, Sa'at MNF, Sirdar Ali S, Syed Mohamed AF
    PLoS One, 2021;16(1):e0245471.
    PMID: 33465140 DOI: 10.1371/journal.pone.0245471
    INTRODUCTION: Hemp (Cannabis sativa subsp. sativa), commonly used for industrial purposes, is now being consumed by the public for various health promoting effects. As popularity of hemp research and claims of beneficial effects rises, a systematic collection of current scientific evidence on hemp's health effects and pharmacological properties is needed to guide future research, clinical, and policy decision making.

    OBJECTIVE: To provide an overview and identify the present landscape of hemp research topics, trends, and gaps.

    METHODS: A systematic search and analysis strategy according to the preferred reporting items for systematic review and meta-analysis-ScR (PRISMA-ScR) checklist on electronic databases including MEDLINE, OVID (OVFT, APC Journal Club, EBM Reviews), Cochrane Library Central and Clinicaltrials.gov was conducted to include and analyse hemp research articles from 2009 to 2019.

    RESULTS: 65 primary articles (18 clinical, 47 pre-clinical) were reviewed. Several randomised controlled trials showed hempseed pills (in Traditional Chinese Medicine formulation MaZiRenWan) improving spontaneous bowel movement in functional constipation. There was also evidence suggesting benefits in cannabis dependence, epilepsy, and anxiety disorders. Pre-clinically, hemp derivatives showed potential anti-oxidative, anti-hypertensive, anti-inflammatory, anti-diabetic, anti-neuroinflammatory, anti-arthritic, anti-acne, and anti-microbial activities. Renal protective effects and estrogenic properties were also exhibited in vitro.

    CONCLUSION: Current evidence on hemp-specific interventions are still preliminary, with limited high quality clinical evidence for any specific therapeutic indication. This is mainly due to the wide variation in test item formulation, as the multiple variants of this plant differ in their phytochemical and bioactive compounds. Future empirical research should focus on standardising the hemp plant for pharmaceutical use, and uniformity in experimental designs to strengthen the premise of using hemp in medicine.

    Matched MeSH terms: Electronics
  13. Mendel B, Christianto, Setiawan M, Prakoso R, Siagian SN
    Curr Cardiol Rev, 2021 Jun 03.
    PMID: 34082685 DOI: 10.2174/1573403X17666210603113430
    BACKGROUND: Junctional ectopic tachycardia (JET) is an arrhythmia originating from the AV junction, which may occur following congenital heart surgery, especially when the intervention is near the atrioventricular junction.

    OBJECTIVE: The aim of this systematic review and meta-analysis is to compare the effectiveness of amiodarone, dexmedetomidine and magnesium in preventing JET following congenital heart surgery.

    METHODS: This meta-analysis was conducted according to the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) statement, where 11 electronic databases were searched from date of inception to August 2020. The incidence of JET was calculated with the relative risk of 95% confidence interval (CI). Quality assessment of the included studies was assessed using the Consolidated Standards of Reporting Trials (CONSORT) 2010 statement.

    RESULTS: Eleven studies met the predetermined inclusion criteria and were included in this meta-analysis. Amiodarone, dexmedetomidine and magnesium significantly reduced the incidence of postoperative JET [Amiodarone: risk ratio 0.34; I2= 0%; Z=3.66 (P=0.0002); 95% CI 0.19-0.60. Dexmedetomidine: risk ratio 0.34; I2= 0%; Z=4.77 (P<0.00001); 95% CI 0.21-0.52. Magnesium: risk ratio 0.50; I2= 24%; Z=5.08 (P<0.00001); 95% CI 0.39-0.66].

    CONCLUSION: All three drugs show promise in reducing the incidence of JET. Our systematic review found that dexmedetomidine is better in reducing the length of ICU stays as well as mortality. In addition, dexmedetomidine also has the least pronounced side effects among the three. However, it should be noted that this conclusion was derived from studies with small sample sizes. Therefore, dexmedetomidine may be considered as the drug of choice for preventing JET.

    Matched MeSH terms: Electronics
  14. Shchelkanov MY, Tabakaeva Moskvina TV, Kim EM, Derunov DA, Galkina IV
    Trop Biomed, 2020 Sep 01;37(3):778-782.
    PMID: 33612790 DOI: 10.47665/tb.37.3.778
    Canine demodicosis is a common skin disorder with multiple risk factors, including age and breed predisposition. There is relatively limited information about the risk factors for canine demodicosis in large canine populations. This retrospective case-control study was conducted by searching the electronic records of dogs with skin lesions for the presence of Demodex mites in skin scrapings. Diagnosis of demodicosis was based on the presence of skin lesions and mites in skin scrapings. Multivariate analysis was conducted using logistic regression analysis to estimate the relative risk and odds ratio of variables hypothesized to influence the risk of canine demodicosis, such as age, sex, breed, season, and parasitic infection. The results of multivariate logistic regression analysis showed a positive correlation between the dogs' age and demodicosis. Dogs older than three years, as well as puppies, had a high risk of demodicosis (P0.05). Breeds with the greatest association (odds ratio) with demodicosis included the American Staffordshire Terrier (OR=0.9) and Moscow Watchdog (OR=0.2). The presence of intestinal parasites, such as Diphyllobothrium latum, was significantly associated with demodicosis.
    Matched MeSH terms: Electronics
  15. Junaid M, Md Khir MH, Witjaksono G, Ullah Z, Tansu N, Saheed MSM, et al.
    Molecules, 2020 Sep 14;25(18).
    PMID: 32937975 DOI: 10.3390/molecules25184217
    In recent years, the field of nanophotonics has progressively developed. However, constant demand for the development of new light source still exists at the nanometric scale. Light emissions from graphene-based active materials can provide a leading platform for the development of two dimensional (2-D), flexible, thin, and robust light-emitting sources. The exceptional structure of Dirac's electrons in graphene, massless fermions, and the linear dispersion relationship with ultra-wideband plasmon and tunable surface polarities allows numerous applications in optoelectronics and plasmonics. In this article, we present a comprehensive review of recent developments in graphene-based light-emitting devices. Light emissions from graphene-based devices have been evaluated with different aspects, such as thermal emission, electroluminescence, and plasmons assisted emission. Theoretical investigations, along with experimental demonstration in the development of graphene-based light-emitting devices, have also been reviewed and discussed. Moreover, the graphene-based light-emitting devices are also addressed from the perspective of future applications, such as optical modulators, optical interconnects, and optical sensing. Finally, this review provides a comprehensive discussion on current technological issues and challenges related to the potential applications of emerging graphene-based light-emitting devices.
    Matched MeSH terms: Electronics
  16. Hwei-Mian Lim, Heng-Leng Chee, Mirnalini Kandiah, Sharifah Zainiyah Syed Yahya, Rashidah Shuib
    Asia Pac J Public Health, 2002;14(2):75-84.
    PMID: 12862411
    The objective of this study was to identify sociodemographic, work, living arrangement and lifestyle factors associated with morbidity of electronics women workers in selected factories in Selangor, Malaysia. The research design was a cross-sectional questionnaire-based survey. Most of the 401 respondents were young single Malay women. Morbidity was high as 85.5% of the women reported experiencing at least one chronic health problem, and 25.7% said that an illness or injury prevented them from carrying out normal activities within the last two weeks. Major acute illness symptoms were the common cold, backache, and diarrhoea while chronic health problems such as persistent headache, eye problems, menstrual problems, and persistent backache were also reported. After logistic regression, chronic health problems was significantly associated with room sharing; while illness that prevented normal activities within the last two weeks was significantly associated with overtime work and exercise. Further research is recommended to understand the complex inter-relationship between morbidity and working and living conditions.
    Matched MeSH terms: Electronics/manpower*
  17. LaDou J, Rohm T
    Int J Occup Environ Health, 1998 Jan-Mar;4(1):1-18.
    PMID: 10026464
    High-technology microelectronics has a major presence in countries such as China, India, Indonesia, and Malaysia, now the third-largest manufacturer of semiconductor chips. The migration of European, Japanese, and American companies accommodates regional markets. Low wage rates and limited enforcement of environmental regulations in developing countries also serve as incentives for the dramatic global migration of this industry. The manufacture of microelectonics products is accompanied by a high incidence of occupational illnesses, which may reflect the widespread use of toxic materials. Metals, photoactive chemicals, solvents, acids, and toxic gases are used in a wide variety of combinations and workplace settings. The industry also presents problems of radiation exposure and various occupational stressors, including some unresolved ergonomic issues. The fast-paced changes of the technology underlying this industry, as well as the stringent security precautions, have added to the difficulty of instituting proper health and safety measures. Epidemiologic studies reveal an alarming increase in spontaneous abortions among cleanroom manufacturing workers; no definitive study has yet identified its cause. Other health issues, including occupational cancer, are yet to be studied. The microelectronics industry is a good example of an industry that is exported to many areas of the world before health and safety problems are properly addressed and resolved.
    Matched MeSH terms: Electronics/organization & administration*
  18. Kim HP, Vasilopoulou M, Ullah H, Bibi S, Ximim Gavim AE, Macedo AG, et al.
    Nanoscale, 2020 Apr 14;12(14):7641-7650.
    PMID: 32207472 DOI: 10.1039/c9nr10745b
    Organo-metal halide perovskite field-effect transistors present serious challenges in terms of device stability and hysteresis in the current-voltage characteristics. Migration of ions located at grain boundaries and surface defects in the perovskite film are the main reasons for instability and hysteresis issues. Here, we introduce a perovskite grain molecular cross-linking approach combined with amine-based surface passivation to address these issues. Molecular cross-linking was achieved through hydrogen bond interactions between perovskite halogens and dangling bonds present at grain boundaries and a hydrophobic cross-linker, namely diethyl-(12-phosphonododecyl)phosphonate, added to the precursor solution. With our approach, we obtained smooth and compact perovskite layers composed of tightly bound grains hence significantly suppressing the generation and migration of ions. Moreover, we achieved efficient surface passivation of the perovskite films upon surface treatment with an amine-bearing polymer, namely polyethylenimine ethoxylated. With our synergistic grain and surface passivation approach, we were able to demonstrate the first perovskite transistor with a complete lack of hysteresis and unprecedented stability upon continuous operation under ambient conditions. Added to the merits are its ambipolar transport of opposite carriers with balanced hole and electron mobilities of 4.02 and 3.35 cm2 V-1 s-1, respectively, its high Ion/Ioff ratio >104 and the lowest sub-threshold swing of 267 mV dec-1 reported to date for any perovskite transistor. These remarkable achievements obtained through a cost-effective molecular cross-linking of grains combined with amine-based surface passivation of the perovskite films open a new era and pave the way for the practical application of perovskite transistors in low-cost electronic circuits.
    Matched MeSH terms: Electronics
  19. Low Qin Jian, Teo Kuo Zhau, Mohd Nadzri Misni, Cheo Seng Wee
    MyJurnal
    Computed tomography pulmonary angiogram (CTPA) is widely used in the investigation of suspected pulmonary embolism. CTPA is not without adverse effects as it involves intravenous contrast injection and radiation exposure. The annual incidence of pulmonary embolism is 60 – 70 per 100,000 populations and CTPA remains the commonest imaging modality1. This study aims to audit all CTPA performed at Hospital Sultanah Nora Ismail, Batu Pahat, Johor for the entire year of 2018 to illustrate the demographic data, symptoms, risk factors, clinical scoring system applied and patients’ outcome. A retrospective study was conducted to audit all CTPA performed between 1st January to 31st December 2018 via the radiology department electronic records and patients’ records. There were a total of 60 CTPA performed in the entire year of 2018 with 16 positive and 44 negative scans. Among the 16 positive scans, 7 (44%) had a Wells score above 6, 6 (38%) had a Wells score between 2 – 6 and 3 (18%) had a Wells score less than 2. Out of the 16 positive scans, 4 (25%) were known malignancy and 1 was a known case of anti-phospholipid syndrome. All 60 patients had electrographs and arterial blood gases performed prior to CTPA. D dimer was performed in 15 cases (5%). Among the 16 positive scan patients, 4 (25%) passed away during the same admission directly or indirectly related to pulmonary embolism. This annual computed tomography audit report will assist clinicians in making better diagnostic decision when dealing with patients with suspected pulmonary embolism.
    Matched MeSH terms: Electronics
  20. Muhammad Zubir Yusof, Nik Ahmad Kamal Nik Mahmod, Nor Azlina A. Rahman, Ailin Razali, Niza Samsuddin, Nik Mohamed Nizan Nik Mohamed, et al.
    MyJurnal
    Occupational diseases are one of the major health problems related to workplace hazards.
    However, the epidemiological data for this problem is scarce especially among Small and
    Medium Industry (SMI) workers. These workers are vulnerable to occupational health problem
    due to lack of knowledge and implementation of health and safety in the workplace. In Malaysia,
    most of the SMI workers have limited coverage for basic occupational health services which
    may worsen their health. Thus, this article aims to provide a review on the burden of
    occupational health problems among them. The electronic and library searches were used to
    extract the information from both published and unpublished articles that were not limited to any
    year of publication until 2017. One hundred and ninety-six published articles and 198
    unpublished articles were retrieved from the database. Only 19 published articles and 25
    unpublished articles met the eligibility criteria. Prevalence data of occupational
    diseases/poisoning, including overall and body specific (musculoskeletal disorders) was
    extracted in raw data from the eligible studies. Prevalent statistics on occupational
    musculoskeletal diseases (1.3% - 97.6%), noise-induced hearing loss (29.4% - 73.3%),
    occupational skin diseases (10.5% - 84.3%), respiratory (1.9% - 92.2%) and occupational
    poisoning (14.9% - 17.7%) among the working population is different within published papers
    compared to unpublished ones. In Malaysia, there are no specific statistic that give a true picture
    of the burden of occupational diseases in the SMI. However, this review concludes that
    musculoskeletal diseases are significant occupational problems among SMI workers.
    Matched MeSH terms: Electronics
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links