METHODS: We prospectively analyzed the use of FloSeal with a hemostatic delivery system in transnasal endoscopic and microscopic skull base procedures performed at the authors' institution from January 1, 2015, to June 30, 2015. In all cases the number of aliquots was noted for the entire operation, and the total number of FloSeal ampules of 5 mL was also recorded.
RESULTS: Our device allowed controlled application of small amounts (0.5-1 mL) of FloSeal to the site of bleeding. This controlled application resulted not only in increased visibility during its application, but it also reduced the amount of FloSeal required during the procedure. We were able to use 5-10 applications per 5-mL ampule of FloSeal within an individual procedure. No procedure required more than one 5-mL ampule of FloSeal. Therefore, the use of our device results in a reduction of costs. Prior to the use of our device, we were often only able to use 1 vial of 5 ml of material for 1 or 2 applications, especially in transnasal endoscopic procedures when working along a deep corridor.
CONCLUSIONS: Our results indicate that our delivery device of FlowSeal can effectively control hemostasis by applying small amounts of FlowSeal to the site of bleeding. This results in increased visibility during hemostasis and a reduction of cost.
METHODS: This is a prospective observational study of 201 patients who underwent endoscopic nasojejunal wire-guided feeding tube insertions for obstruction of either the esophagus or the stomach including both benign and malignant pathologies between January 2015 to June 2018 in Hospital Sungai Buloh and Hospital Sultanah Aminah, Malaysia. The indications for tube insertion, insertion technique, and tube-related problems were described.
RESULTS: The nasojejunal tube was used to establish enteral feeding in patients with obstructing tumors of the distal esophagus in 65 patients (32.3%) and gastric outlet obstruction in 72 patients (35.8%). There were 54 patients (26.9%) who required reinsertion. The most common reason for reinsertion was unintentional dislodgement, where 32 patients (15.9%) followed by tube blockage 20 patients (10.0%). Using our method of advancement under direct vision, we had only 2 cases of malposition due to severely deformed anatomy. We had no incidence of aspiration in this group of patients and overall, the patients tolerated the tube well.
CONCLUSIONS: The novel nasojejunal feeding tube with gastric decompression function is a safe and effective method of delivery of enteral nutrition in patients with upper gastrointestinal obstruction. These tubes if inserted properly are well tolerated with almost no risk of malposition and are tolerated well even for prolonged periods of time until definitive surgery could be performed.
MATERIALS AND METHODS: Sixty patients who underwent IBCT were allocated to Group I (n = 30; microscopic IBCT) and Group II (n = 30; endoscopic IBCT) by the dates of their visits. Anatomical success was defined as an intact, repaired tympanic membrane; functional success was defined as a significant decrease in the air-bone gap. Postoperative discomfort was analyzed using a visual analog scale (VAS). Thirteen trainees completed structured questionnaires exploring anatomical identification and the surgical steps.
RESULTS: The surgical success rates were 96.7% in Group I and 100% in Group II. We found no between-group differences in the mean decrease in the air-bone gap or the extent of postoperative discomfort. Significant postoperative hearing improvements were evident in both groups. The mean operative time was shorter when the microscopic approach was chosen (17.7±4.53 vs. 26.13±9.94 min). The two approaches significantly differed in terms of the identification of external and middle ear anatomical features by the trainees, and their understanding of the surgical steps.
CONCLUSION: Both endoscopic and microscopic IBCT were associated with good success rates. The endoscopic approach facilitates visualization, and a better understanding of the middle ear anatomy and the required surgical steps and thus is of greater educational utility.
CASE REPORT: A 34-year-old woman with intractable epigastric pain was referred to have repeated endoscopy with biopsy. She was found to multiple gastric erosions and nodules that were diagnosed as inflammatory lesions both endoscopically and histologically. Meanwhile, she developed an acute onset of severe back pain associated with a pathologic compression fracture in the T3 thoracic vertebral body. Imaging studies disclosed a disseminated systemic disease involving abdominopelvic lymph nodes and cervical and thoracic vertebral bodies. The needle biopsy of the pelvic lymph node disclosed diffuse proliferation of monomorphic small round cells that were diffusely positive for CD30 and ALK. A diagnosis of ALK+ ALCL with a monomorphic SC pattern was rendered.
DISCUSSION: A retrospective review of the gastric biopsies with the aid of immunohistochemistry enabled us to recognise the presence of lymphomatous infiltrates with a mixed LH and SC pattern in every piece of gastric biopsies that were repeatedly misdiagnosed as inflammatory lesions. This case illustrates a significant diagnostic pitfall of the LH- and SC-patterns in ALK+ ALCL, in which the tumour cells featuring lymphoid, plasmacytoid or histiocytoid appearance can be masqueraded as inflammatory cells.