Displaying publications 1 - 20 of 46 in total

Abstract:
Sort:
  1. Tan LP, Foong KK, Yvonne Ai LL
    Med J Malaysia, 2018 10;73(5):334-335.
    PMID: 30350818 MyJurnal
    Amebiasis is one of the major causes of diarrhea in the developing countries and it can present with a wide range of gastrointestinal symptoms depending on the phase of infection. We described a case of 50 year-old male patient who presented with abdominal pain, diarrhea and vomiting. After right hemicolectomy for appendicular abscess with tumour over the ileum, histopathological examinations revealed numerous trophozoites of Entamoeba histolytica in a background of inflammations (Figure 1). Following resection of the ameboma, he received intravenous metronidazole treatment for total of two weeks duration.
    Matched MeSH terms: Entamoeba histolytica
  2. Zeehaida M, Wan Nor Amilah WA, Amry AR, Hassan S, Sarimah A, Rahmah N
    Trop Biomed, 2008 Dec;25(3):209-16.
    PMID: 19287359
    Amoebic serodiagnosis at Hospital Universiti Sains Malaysia (HUSM), Kelantan employs an indirect haemagglutination assay (IHA) which detects anti-Entamoeba histolytica antibodies in patients' serum samples. In an amoebiasis endemic area such as Kelantan, interpretation of a positive IHA result can be problematic due to the high background antibody levels. The TechLab E. histolytica II ELISA is a commercial kit for detection of specific Gal/GalNAc lectin antigen in stool samples, and has been reported to be able to detect the antigen in serum samples from patients with amoebic liver abscess (ALA). Thus in this study we investigated the usefulness of TechLab E. histolytica II ELISA for diagnosis of ALA by comparing it with IHA. This is a cross sectional study involving 58 suspected ALA patients who were admitted to the surgical ward, HUSM, Kelantan. The diagnosis of ALA was established based on clinical symptoms and signs, ultrasound and/or CT scan results. The serum specimens obtained from the patients were tested with IHA (Dade Behring Diagnostics, Marburg, Germany) and TechLab E. histolytica II ELISA (Techlab, Blacksburg, Virginia, USA) according to the manufacturers' instructions. Of the 58 patients, 72.4% (42) were positive by IHA and only 8.6% (5) were positive by the TechLab E. histolytica II ELISA. Agreement between the IHA and ELISA was poor (kappa value 0.019, p=0.691). There was also no correlation between ELISA results and IHA antibody titers. The TechLab E. histolytica II ELISA was not sensitive in detecting amoebic antigen in samples from ALA patients. In addition the results of the test did not correlate with the IHA anti-E. histolytica antibody titres. Therefore, the TechLab E. histolytica II ELISA was found not to be useful for serological diagnosis of ALA at HUSM.
    Matched MeSH terms: Entamoeba histolytica/immunology*
  3. Ray S, Khanra D, Saha M, Talukdar A
    Med J Malaysia, 2012 Oct;67(5):524-5.
    PMID: 23770872
    Amebic liver abscess is the most common extraintestinal manifestation of infection with Entamoeba histolytica. It is a common disease, especially in endemic areas, but it is a rare cause of inferior vena cava (IVC) obstruction, with only a few cases appearing in the literature. The authors describe a case of amebic liver abscess in a patient who developed a rare vascular complication of inferior vena cava thrombosis. The case responded to conservative treatment and radiological intervention.
    Matched MeSH terms: Entamoeba histolytica
  4. McClatchie S, Sambhi JS
    Ann Trop Med Parasitol, 1971 Jun;65(2):207-10.
    PMID: 4326239
    Matched MeSH terms: Entamoeba histolytica/isolation & purification
  5. Mansharan Kaur Chaincel Singh
    MyJurnal
    Amoebiasis is a parasitic infection caused by the
    intestinal protozoan Entamoeba histolytica, most
    prevalent in developing countries. It results in 40,000 to
    100,000 deaths each year from amoebic colitis and extra
    intestinal infections. Amoebic liver abscess (ALA)
    is the most common extra intestinal site of infection
    with an incidence of between 3% and 9% of all cases of
    amoebiasis. Ultrasound which has a sensitivity of more
    than 90% for detecting ALA is highly recommended
    as an initial investigation followed by serological
    demonstration of circulating antibodies specific to
    Entamoeba histolytica.
    Matched MeSH terms: Entamoeba histolytica
  6. Ujang J, Sani AAA, Lim BH, Noordin R, Othman N
    Proteomics, 2018 12;18(23):e1700397.
    PMID: 30284757 DOI: 10.1002/pmic.201700397
    Entamoeba histolytica membrane proteins are important players toward the pathogenesis of amoebiasis, but the roles of most of the proteins are not fully understood. Since efficient protein extraction method is crucial for a successful MS analysis, three extractions methods are evaluated for the use in studying the membrane proteome of E. histolytica: Two commercial kits (ProteoExtract from Calbiochem and ProteoPrep from Sigma), and a conventional laboratory method. The results show that ProteoExtract and the conventional method gave higher protein yields compared to ProteoPrep. LC-ESI-MS/MS identifies 456, 482, and 551 membrane fraction proteins extracted using ProteoExtract, ProteoPrep, and a conventional method, respectively. In silico analysis predicts 108 (21%), 235 (45%), and 177 (34%) membrane proteins from the extracts of ProteoExtract, ProteoPrep, and the conventional method, respectively. Furthermore, analysis of the cytosolic and membrane fractions shows the highest selectivity of the membrane proteins using the ProteoPrep extraction kit. Overall, this study reports 828 E. histolytica membrane fraction proteins that include 249 predicted membrane proteins. The data are available via ProteomeXchange with identifier PXD010171.
    Matched MeSH terms: Entamoeba histolytica
  7. Wong WK, Tan ZN, Othman N, Lim BH, Mohamed Z, Olivos Garcia A, et al.
    Clin Vaccine Immunol, 2011 Nov;18(11):1913-7.
    PMID: 21918120 DOI: 10.1128/CVI.05356-11
    Serodiagnosis of amoebiasis remains the preferred method for diagnosis of amoebic liver abscess (ALA). However, the commercially available kits are problematic in areas of endemicity due to the persistently high background antibody titers. Human serum samples (n = 38) from patients with ALA who live in areas of endemicity were collected from Hospital Universiti Sains Malaysia during the period of 2008 to 2010. Western blots using excretory-secretory antigen (ESA) collected from axenically grown Entamoeba histolytica were probed with the above serum samples. Seven antigenic proteins of ESA with various reactivities were identified, i.e., 152 kDa, 131 kDa, 123 kDa, 110 kDa, 100 kDa, 82 kDa, and 76 kDa. However, only the 152-kDa and 110-kDa proteins showed sensitivities above 80% in the Western blot analysis. All the antigenic proteins showed undetectable cross-reactivity when probed with healthy human serum samples (n = 30) and serum samples from other infections (n = 33). From the matrix-assisted laser desorption ionization-two-stage time of flight (MALDI-TOF/TOF) analysis, the proteins were identified as heavy subunits of E. histolytica lectin and E. histolytica pyruvate phosphate dikinase, respectively. Use of the E. histolytica lectin for diagnosis of ALA has been well reported by researchers and is being used in commercialized kits. However, this is the first report on the potential use of pyruvate phosphate dikinase for diagnosis of ALA; thus, this molecule merits further evaluation on its diagnostic value using a larger panel of serum samples.
    Matched MeSH terms: Entamoeba histolytica/immunology*; Entamoeba histolytica/chemistry*
  8. Kumarasamy G, Abdus Sani AA, Olivos-García A, Noordin R, Othman N
    Pathog Glob Health, 2020 09;114(6):333-342.
    PMID: 32536281 DOI: 10.1080/20477724.2020.1780402
    Amoebiasis, caused by Entamoeba histolytica, is one of the leading parasitic infections in the world. This study was aimed at profiling antigenic membrane proteins of a virulent variant of E. histolytica HM-1:IMSS. The membrane proteins were extracted using ProteoExtract® kit (Merck, Darmstadt, Germany) or conventional method, separated using OFFGEL 3100 fractionator (Agilent Technologies, Santa Clara, California), followed by SDS-PAGE and Western blot analysis. Selected antigenic membrane proteins were identified using LC-ESI-MS/MS. Subsequently, the proteins were classified according to their biological processes and predictions were made on membrane and membrane-associated proteins. When the proteins were probed with pooled sera from amoebic liver abscess (ALA) patients, 10 and 15 antigenic proteins with molecular weights 25 to 200 kDa were identified using the ProteoExtract® kit and conventional method, respectively. LC-ESI-MS/MS identified 13 antigenic proteins, and both extraction methods predicted six of them as membrane and membrane-associated proteins. The topmost biological processes which comprised of six proteins were involved in cellular processes.. These antigenic membrane proteins merit further investigations as potential candidates for vaccine studies.
    Matched MeSH terms: Entamoeba histolytica*
  9. Othman N, Mohamed Z, Verweij JJ, Huat LB, Olivos-García A, Yeng C, et al.
    Foodborne Pathog Dis, 2010 Jun;7(6):637-41.
    PMID: 20132028 DOI: 10.1089/fpd.2009.0427
    Entamoeba histolytica is the second major cause of liver abscess disease in humans, particularly in developing countries. Recently, DNA molecular-based methods have been employed to enhance the detection of E. histolytica in either pus or stool specimens. In this study, the results of real-time polymerase chain reaction (PCR) to detect E. histolytica DNA in pus from liver abscess cases were compared with those of indirect hemagglutination assay on the corresponding serum samples. Bacterial cultures were also performed on the pus samples for the diagnosis of pyogenic liver abscess. The real-time PCR detected E. histolytica DNA in 23 of 30 (76.7%) pus samples, when compared with 14 of 30 (46.7%) serum samples in which anti-Entamoeba antibodies were detected by indirect hemagglutination assay and 4 of 30 (13.3%) pus samples that showed bacterial infection by culture. The use of real-time PCR is a promising detection method for diagnosis and epidemiology assessment of amoebic liver abscess.
    Matched MeSH terms: Entamoeba histolytica/classification; Entamoeba histolytica/genetics; Entamoeba histolytica/immunology; Entamoeba histolytica/isolation & purification*
  10. Wong WK, Tan ZN, Lim BH, Mohamed Z, Olivos-Garcia A, Noordin R
    Parasitol Res, 2011 Feb;108(2):425-30.
    PMID: 20922423 DOI: 10.1007/s00436-010-2083-8
    Entamoeba histolytica is the etiologic agent for amoebiasis. The excretory-secretory (ES) products of the trophozoites contain virulence factors and antigens useful for diagnostic applications. Contaminants from serum supplements and dead trophozoites impede analysis of ES. Therefore, a protein-free medium that can sustain maximum viability of E. histolytica trophozoites for the longest time duration will enable collection of contaminant-free and higher yield of ES products. In the present study, we compared the efficacy of four types of media in maintaining ≥ 95% trophozoite viability namely Roswell Memorial Park Institute (RPMI-1640), Dulbecco's Modified Eagle Medium (DMEM), phosphate-buffered saline for amoeba (PBS-A), and Hank's balanced salt solution (HBSS). Concurrently, the effect of adding L: -cysteine and ascorbic acid (C&A) to each medium on the parasite viability was also compared. DMEM and RPMI 1640 showed higher viabilities as compared to PBS-A and HBSS. Only RPMI 1640 showed no statistical difference with the control medium for the first 4 h, however the ≥ 95% viability was only maintained for the first 2 h. The other protein-free media showed differences from the serum- and vitamin-free TYI-S-33 control media even after 1 h of incubation. When supplemented with C&A, all media were found to sustain higher trophozoite viabilities than those without the supplements. HBSS-C&A, DMEM-C&A, and RPMI 1640-C&A demonstrated no difference (P>0.05) in parasite viabilities when compared with the control medium throughout the 8-h incubation period. DMEM-C&A showed an eightfold increment in time duration of sustaining ≥ 95% parasite viability, i.e. 8 h, as compared to DMEM alone. Both RPMI 1640-C&A and HBSS-C&A revealed fourfold and threefold increments (i.e., 8 and 6 h, respectively), whereas PBS-A-C&A showed only one fold improvement (i.e., 2 h) as compared to the respective media without C&A. Thus, C&A-supplemented DMEM or RPMI are recommended for collection of ES products.
    Matched MeSH terms: Entamoeba histolytica/cytology; Entamoeba histolytica/drug effects*; Entamoeba histolytica/physiology
  11. Mohd Shah NA, Wan Abdul Wahab WN, Mohd Nawi SF, Mohd-Zain Z, Latif B, Suhaimi R
    Malays J Pathol, 2015 Dec;37(3):271-4.
    PMID: 26712674 MyJurnal
    Entamoeba histolytica, the causative agent for human amoebiasis, is among the most deadly parasites, accounting for the second highest mortality rate among parasitic diseases. Because this parasite dwells in low oxygen tension, for its cultivation, microaerophilic conditions are required to mimick the human gut environment. Several methods developed for optimal growth environment are commercially available and some are conventionally modified in-house which include the Anaerocult A and oil blocking preparation methods. This study was undertaken to compare the reliability of the Anaerocult A and the oil blocking methods in generating anaerobic environment for cultivation of E. histolytica. The trophozoites of E. histolytica HM1: IMSS strains were axenically cultivated in TYI-S-33 medium in culture incubated anaerobically by using Anaerocult A (Merck) and mineral oil blocking method. The outcomes of both methods were determined by the minimum inhibitory concentration (MIC) of metronidazole against E. histolytica by giving a score to the growth pattern of the trophozoites. The reliability of both methods was assessed based on susceptibility testing of E. histolytica to metronidazole. The MIC obtained by both anaerobic condition methods was 6.25 ug/ ml, thus showing that oil-blocking method is comparable to the Anaerocult A method and therefore, considered as a reliable method for generating an anaerobic environment for the cultivation of E. histolytica.
    Matched MeSH terms: Entamoeba histolytica*
  12. Ning TZ, Kin WW, Mustafa S, Ahmed A, Noordin R, Cheong TG, et al.
    Asian Pac J Trop Biomed, 2012 Jan;2(1):61-5.
    PMID: 23569836 DOI: 10.1016/S2221-1691(11)60191-3
    To compare the efficacy of three different tissue stains, namely haematoxylin and eosin (H&E), periodic-acid Schiff (PAS) and immunohistochemical (IHC) stains for detection of Entamoeba histolytica (E. histolytica) trophozoites in abscessed liver tissues of hamster.
    Matched MeSH terms: Entamoeba histolytica/cytology; Entamoeba histolytica/isolation & purification*
  13. Angal L, Mahmud R, Samin S, Yap NJ, Ngui R, Amir A, et al.
    BMC Infect Dis, 2015 Oct 29;15:467.
    PMID: 26511347 DOI: 10.1186/s12879-015-1178-3
    BACKGROUND: The prison management in Malaysia is proactively seeking to improve the health status of the prison inmates. Intestinal parasitic infections (IPIs) are widely distributed throughout the world and are still gaining great concern due to their significant morbidity and mortality among infected humans. In Malaysia, there is a paucity of information on IPIs among prison inmates. In order to further enhance the current health strategies employed, the present study aims to establish firm data on the prevalence and diversity of IPIs among HIV-infected and non-HIV-infected individuals in a prison, an area in which informed knowledge is still very limited.

    METHODS: Samples were subjected to microscopy examination and serological test (only for Strongyloides). Speciation for parasites on microscopy-positive samples and seropositive samples for Strongyloides were further determined via polymerase chain reaction. SPSS was used for statistical analysis.

    RESULTS: A total of 294 stool and blood samples each were successfully collected, involving 131 HIV positive and 163 HIV negative adult male inmates whose age ranged from 21 to 69-years-old. Overall prevalence showed 26.5% was positive for various IPIs. The IPIs detected included Blastocystis sp., Strongyloides stercoralis, Entamoeba spp., Cryptosporidium spp., Giardia spp., and Trichuris trichiura. Comparatively, the rate of IPIs was slightly higher among the HIV positive inmates (27.5%) than HIV negative inmates (25.8%). Interestingly, seropositivity for S. stercoralis was more predominant in HIV negative inmates (10.4%) compared to HIV-infected inmates (6.9%), however these findings were not statistically significant. Polymerase chain reaction (PCR) confirmed the presence of Blastocystis, Strongyloides, Entamoeba histolytica and E. dispar.

    CONCLUSIONS: These data will enable the health care providers and prison management staff to understand the trend and epidemiological situations in HIV/parasitic co-infections in a prison. This information will further assist in providing evidence-based guidance to improve prevention, control and management strategies of IPIs co-infections among both HIV positive and HIV negative inmates in a prison environment.

    Matched MeSH terms: Entamoeba histolytica/isolation & purification; Entamoeba histolytica/pathogenicity
  14. Saidin S, Yunus MH, Othman N, Lim YA, Mohamed Z, Zakaria NZ, et al.
    Pathog Glob Health, 2017 May;111(3):128-136.
    PMID: 28335696 DOI: 10.1080/20477724.2017.1300421
    Entamoeba histolytica infection remains a public health concern in developing countries. Early diagnosis of amoebiasis can avoid disease complications, thus this study was aimed at developing a test that can rapidly detect the parasite antigens in stool samples. Rabbits were individually immunized with recombinant pyruvate phosphate dikinase (rPPDK) and E. histolytica excretory-secretory antigens to produce polyclonal antibodies. A rapid dipstick test was produced using anti-rPPDK PAb lined on the dipstick as capture reagent and anti-EhESA PAb conjugated to colloidal gold as the detector reagent. Using E. histolytica-spiked in stool sample of a healthy individual, the detection limit of the dipstick test was found to be 1000 cells ml-1. Meanwhile when rPPDK was spiked in the stool sample, the minimum concentration detected by the dipstick test was 0.1 μg ml-1. The performances of the dipstick, commercial Techlab E. histolytica II enzyme-linked immunosorbent assays (ELISA) and real-time PCR were compared using 70 stool samples from patients infected with Entamoeba species (n = 45) and other intestinal pathogens (n = 25). When compared to real-time PCR, the diagnostic sensitivity of the dipstick for detection of E. histolytica was 65.4% (n = 17/26); while the diagnostic specificity when tested with stool samples containing other intestinal pathogens was 92% (23/25). In contrast, Techlab E. histolytica II ELISA detected 19.2% (5/26) of the E. histolytica-positive samples as compared to real-time PCR. The lateral flow dipstick test produced in this study enabled rapid detection of E. histolytica, thus it showed good potential to be further developed into a diagnostic tool for intestinal amoebiasis.
    Matched MeSH terms: Entamoeba histolytica/enzymology; Entamoeba histolytica/immunology*; Entamoeba histolytica/isolation & purification
  15. Foo PC, Chan YY, Mohamed M, Wong WK, Nurul Najian AB, Lim BH
    Anal Chim Acta, 2017 May 08;966:71-80.
    PMID: 28372729 DOI: 10.1016/j.aca.2017.02.019
    This study highlighted the development of a four target nitrocellulose-based nucleic acid lateral flow immunoassay biosensor in a dry-reagent strip format for interpretation of double-labelled double-stranded amplicons from thermostabilised triplex loop-mediated isothermal amplification assay. The DNA biosensor contained two test lines which captured biotin and texas red labelled amplicons; a LAMP internal amplification control line that captured digoxigenin labelled amplicon; and a chromatography control line that validated the functionality of the conjugated gold nanoparticles and membrane. The red lines on detection pad were generated when the gold nanoparticles conjugated antibody bound to the fluorescein labelled amplicons, and the capture agents bound to their specific hapten on the other 5' end of the double-stranded amplicon. The applicability of this DNA biosensor was demonstrated using amoebiasis-causing Entamoeba histolytica simultaneously with the non-pathogenic but morphologically identical Entamoeba dispar and Entamoeba moshkovskii. The biosensor detection limit was 10 E. histolytica trophozoites, and revealed 100% specificity when it was evaluated against 3 medically important Entamoeba species and 75 other pathogenic microorganisms. Heat stability test showed that the biosensor was stable for at least 181 days at ambient temperature. This ready-to-use and cold-chain-free biosensor facilitated the post-LAMP analysis based on visualisation of lines on strip instead of observation of amplicon patterns in agarose gel.
    Matched MeSH terms: Entamoeba histolytica/isolation & purification*
  16. Foo PC, Chan YY, See Too WC, Tan ZN, Wong WK, Lalitha P, et al.
    J Med Microbiol, 2012 Sep;61(Pt 9):1219-1225.
    PMID: 22556327 DOI: 10.1099/jmm.0.044552-0
    Entamoeba histolytica is the only Entamoeba species that causes amoebiasis in humans. Approximately 50 million people are infected, with 100, 000 deaths annually in endemic countries. Molecular diagnosis of Entamoeba histolytica is important to differentiate it from the morphologically identical Entamoeba dispar to avoid unnecessary medication. Conventional molecular diagnostic tests require trained personnel, cold-chain transportation and/or are storage-dependent, which make them user-unfriendly. The aim of this study was to develop a thermostabilized, one-step, nested, tetraplex PCR assay for the detection of Entamoeba histolytica, Entamoeba dispar and Entamoeba species in cold-chain-free and ready-to-use form. The PCR test was designed based on the Entamoeba small subunit rRNA (SSU-rRNA) gene, which detects the presence of any Entamoeba species, and simultaneously can be used to differentiate Entamoeba histolytica from Entamoeba dispar. In addition, a pair of primers was designed to serve as an internal amplification control to help identify inhibitors in the samples. All PCR reagents together with the designed primers were thermostabilized by lyophilization and were stable at 24 °C for at least 6 months. The limit of detection of the tetraplex PCR was found to be 39 pg DNA or 1000 cells for Entamoeba histolytica and 78 pg DNA or 1000 cells for Entamoeba dispar, and the specificity was 100 %. In conclusion, this cold-chain-free, thermostabilized, one-step, nested, multiplex PCR assay was found to be efficacious in differentiating Entamoeba histolytica from other non-pathogenic Entamoeba species.
    Matched MeSH terms: Entamoeba histolytica/classification*; Entamoeba histolytica/genetics*; Entamoeba histolytica/isolation & purification
  17. Tan ZN, Wong WK, Noordin R, Zeehaida M, Olivos GA, Lim BH
    Trop Biomed, 2013 Jun;30(2):250-6.
    PMID: 23959490 MyJurnal
    Entamoeba histolytica causes amoebic diarrhoea, colitis and liver abscess (ALA). Diagnosis of ALA is difficult, as most patients do not have simultaneous intestinal amoebic infection. At Hospital Universiti Sains Malaysia (HUSM), diagnosis of ALA relies on a combination of clinical findings, ultrasound examination of the liver and serodiagnosis using a commercial kit. In this study, two in-house indirect ELISAs were developed and evaluated. One of the in-house assays utilises E. histolytica crude soluble antigen (CSA) to detect serum IgG specific to the parasite whereas the other uses E. histolytica ether extract antigen (EEA). Preparation of CSA requires a sonicator to lyse the amoeba whereas EEA was prepared by chemically solubilizing the trophozoites. Based on the cut-off value of mean optical density + 3SD, CSA-ELISA showed 100% (24/24) sensitivity and 93.33% (210/225) specificity; while EEA-ELISA showed 91.67% (22/24) sensitivity and 95.11% (214/225) specificity. In conclusion, both the in-house indirect ELISAs were found to be efficacious for diagnosis of ALA; and the EEA is easier to prepare than the commonly used CSA.
    Matched MeSH terms: Entamoeba histolytica/immunology*
  18. Othman NH, Ismail AN
    Eur J Obstet Gynecol Reprod Biol, 1993 Dec 15;52(2):135-7.
    PMID: 8157142
    A case of endometrial infection by Entamoeba histolytica is described in an elderly lady who presented with profuse vaginal discharge and was clinically misdiagnosed as endometrial carcinoma.
    Matched MeSH terms: Entamoeba histolytica*
  19. Othman N, Mohamed Z, Yahya MM, Leow VM, Lim BH, Noordin R
    Exp Parasitol, 2013 Aug;134(4):504-10.
    PMID: 23680184 DOI: 10.1016/j.exppara.2013.05.001
    Entamoeba histolytica is a causative agent of amoebic liver abscess (ALA) and is endemic in many underdeveloped countries. We investigated antigenic E. histolytica proteins in liver abscess aspirates using proteomics approach. Pus samples were first tested by real-time PCR to confirm the presence of E. histolytica DNA and the corresponding serum samples tested for E. histolytica-specific IgG by a commercial ELISA. Proteins were extracted from three and one pool(s) of pus samples from ALA and PLA (pyogenic liver abscess) patients respectively, followed by analysis using isoelectric focussing, SDS-PAGE and Western blot. Unpurified pooled serum samples from infected hamsters and pooled human amoebic-specific IgG were used as primary antibodies. The antigenic protein band was excised from the gel, digested and analysed by MALDI-TOF/TOF and LC-MS/MS. The results using both primary antibodies showed an antigenic protein band of ∼14kDa. Based on the mass spectrum analysis, putative tyrosine kinase is the most probable identification of the antigenic band.
    Matched MeSH terms: Entamoeba histolytica/genetics; Entamoeba histolytica/immunology*
  20. Azmi N, Othman N
    Membranes (Basel), 2021 May 21;11(6).
    PMID: 34063994 DOI: 10.3390/membranes11060376
    Amoebiasis is caused by Entamoeba histolytica and ranked second for parasitic diseases causing death after malaria. E. histolytica membrane and cytosolic proteins play important roles in the pathogenesis. Our previous study had shown several cytosolic proteins were found in the membrane fraction. Therefore, this study aimed to quantify the differential abundance of membrane and cytosolic proteins in membrane versus cytosolic fractions and analyze their predicted functions and interaction. Previous LC-ESI-MS/MS data were analyzed by PERSEUS software for the differentially abundant proteins, then they were classified into their functional annotations and the protein networks were summarized using PantherDB and STRiNG, respectively. The results showed 24 (44.4%) out of the 54 proteins that increased in abundance were membrane proteins and 30 were cytosolic proteins. Meanwhile, 45 cytosolic proteins were found to decrease in abundance. Functional analysis showed differential abundance proteins involved in the molecular function, biological process, and cellular component with 18.88%, 33.04% and, 48.07%, respectively. The STRiNG server predicted that the decreased abundance proteins had more protein-protein network interactions compared to increased abundance proteins. Overall, this study has confirmed the presence of the differentially abundant membrane and cytosolic proteins and provided the predictive functions and interactions between them.
    Matched MeSH terms: Entamoeba histolytica
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links