Displaying publications 1 - 20 of 597 in total

Abstract:
Sort:
  1. Kotresha D, Noordin R
    APMIS, 2010 Aug;118(8):529-42.
    PMID: 20666734 DOI: 10.1111/j.1600-0463.2010.02629.x
    Toxoplasma gondii is an important human pathogen with a worldwide distribution. It is primarily of medical importance for pregnant women and immunocompromised patients. Primary infection of the former is often associated with fetal infection, which can lead to abortion or severe neonatal malformation. Immunocompromised patients are at risk of contracting the severe form of the disease that may be fatal. Thus, detection of T. gondii infection with high sensitivity and specificity is crucial in the management of the disease. Toxoplasmosis is generally diagnosed by demonstrating specific immunoglobulin M (IgM) and IgG antibodies to toxoplasma antigens in the patient's serum sample. Most of the commercially available tests use T. gondii native antigens and display wide variations in test accuracy. Recombinant antigens have great potential as diagnostic reagents for use in assays to detect toxoplasmosis. Thus in this review, we address recent advances in the use of Toxoplasma recombinant proteins for serodiagnosis of toxoplasmosis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  2. Shafiee MN, Mongan N, Seedhouse C, Chapman C, Deen S, Abu J, et al.
    Acta Obstet Gynecol Scand, 2017 May;96(5):556-562.
    PMID: 28176325 DOI: 10.1111/aogs.13106
    INTRODUCTION: Women with polycystic ovary syndrome have a three-fold higher risk of endometrial cancer. Insulin resistance and hyperlipidemia may be pertinent factors in the pathogenesis of both conditions. The aim of this study was to investigate endometrial sterol regulatory element binding protein-1 gene expression in polycystic ovary syndrome and endometrial cancer endometrium, and to correlate endometrial sterol regulatory element binding protein-1 gene expression with serum lipid profiles.

    MATERIAL AND METHODS: A cross-sectional study was performed at Nottingham University Hospital, UK. A total of 102 women (polycystic ovary syndrome, endometrial cancer and controls; 34 participants in each group) were recruited. Clinical and biochemical assessments were performed before endometrial biopsies were obtained from all participants. Taqman real-time polymerase chain reaction for endometrial sterol regulatory element binding protein-1 gene and its systemic protein expression were analyzed.

    RESULTS: The body mass indices of women with polycystic ovary syndrome (29.28 ± 2.91 kg/m(2) ) and controls (28.58 ± 2.62 kg/m(2) ) were not significantly different. Women with endometrial cancer had a higher mean body mass index (32.22 ± 5.70 kg/m(2) ). Sterol regulatory element binding protein-1 gene expression was significantly increased in polycystic ovary syndrome and endometrial cancer endometrium compared with controls (p 

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  3. Tan CH, Tan NH, Sim SM, Fung SY, Gnanathasan CA
    Acta Trop, 2012 Jun;122(3):267-75.
    PMID: 22322247 DOI: 10.1016/j.actatropica.2012.01.016
    Envenomation by hump-nosed pit viper (Hypnale hypnale, Hh) in Sri Lanka has caused significant morbidity and mortality, attributed to 35% of total venomous snakebites. In Southwestern India (Kerala), H. hypnale was increasingly identified as a dangerous and common source of envenomation, second to the Russell's viper but ahead of the cobra bites. Unfortunately, there is still no specific antivenom to date. This study aims to investigate the immunological properties of the venom and to assess the feasibility of specific Hh antivenom production as well as the development of a diagnostic assay. Hh venom elicited satisfactory titers of anti-Hh IgG in rabbits after 3rd immunization. The anti-Hh IgG, isolated with caprylic acid precipitation method, was effective in neutralizing the venom lethality (potency=48 LD(50) per ml IgG) as well as its procoagulant, hemorrhagic and necrotic effects, indicating the possibility to produce the specific antivenom using the common immunization regime. Cross-reactivity studies using indirect ELISA showed that anti-Hh IgG cross-reacted extensively with several Asiatic crotalid venoms, particularly that of Calloselasma rhodostoma (73.6%), presumably due to the presence of venom antigens common to both snakes. Levels of immunological cross-reactivity were vastly reduced with double-sandwich ELISA. Further work demonstrated that the assay was able to distinguish and quantify venoms of H. hypnale, Daboia russelii and Echis carinatus sinhaleyus (three common local viperid) used to spike human sera at various concentrations. The assay hence may be a useful investigating tool for diagnosing biting species and studying the time course profile of venom concentrations in blood.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  4. Noordin R, Smith HV, Mohamad S, Maizels RM, Fong MY
    Acta Trop, 2005 Jan;93(1):57-62.
    PMID: 15589798
    Diagnosis of human toxocariasis, caused by Toxocara canis or Toxocara cati, normally relies on a combination of the presence of clinical signs and symptoms backed by positive serology. The use of Toxocara excretory-secretory antigen (TES) in ELISA assays increases the test specificity. However, in tropical countries where soil-transmitted helminths are endemic, cross-reactivity from antibodies to these intestinal parasites poses a significant limitation for Toxocara serodiagnosis. To increase the specificity of serodiagnosis, we compared the use of IgG-ELISA to the use of IgG4-ELISA using commercially manufactured TES-coated plates. The sensitivity of the IgG-ELISA was 97.1%, while that of the IgG4-ELISA was 45.7%; the specificities were 36.0 and 78.6%, respectively. The study shows that employing both assays can improve the serodiagnosis of toxocariasis. An IgG4 immunoassay would also be useful in the secondary screening of antigen clones in the effort to develop improved serological tests for toxocariasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  5. Leong PK, Fung SY, Tan CH, Sim SM, Tan NH
    Acta Trop, 2015 Sep;149:86-93.
    PMID: 26026717 DOI: 10.1016/j.actatropica.2015.05.020
    The low potency of cobra antivenom has been an area of concern in immunotherapy for cobra envenomation. This study sought to investigate factors limiting the neutralizing potency of cobra antivenom, using a murine model. We examined the immunological reactivity and neutralizing potency of a Thai polyvalent antivenom against the principal toxins of Naja sumatrana (Equatorial spitting cobra) venom and two related Asiatic cobra venom α-neurotoxins. The antivenom possesses moderate neutralizing potency against phospholipases A2 (P, potency of 0.98mg/mL) and moderately weak neutralizing potency against long-chain α-neurotoxins (0.26-0.42mg/mL) but was only weakly effective in neutralizing the short-chain α-neurotoxins and cardiotoxins (0.05-0.08mg/mL). The poor neutralizing potency of the antivenom on the low molecular mass short-chain neurotoxins and cardiotoxins is presumably the main limiting factor of the efficacy of the cobra antivenom. Our results also showed that phospholipase A2, which exhibited the highest ELISA reactivity and avidity, was most effectively neutralized, whereas N. sumatrana short-chain neurotoxin, which exhibited the lowest ELISA reactivity and avidity, was least effectively neutralized by the antivenom. These observations suggest that low immunoreactivity (low ELISA reactivity and avidity) is one of the reasons for poor neutralization of the cobra venom low molecular mass toxins. Nevertheless, the overall results show that there is a lack of congruence between the immunological reactivity of the toxins toward antivenom and the effectiveness of toxin neutralization by the antivenom, indicating that there are other factors that also contribute to the weak neutralization capacity of the antivenom. Several suggestions have been put forward to overcome the low efficacy of the cobra antivenom. The use of a 'proper-mix' formulation of cobra venoms as immunogen, whereby the immunogen mixture used for hyperimmunization contains a mix of various types of α-neurotoxins and cardiotoxins in sufficient amount, may also help to improve the efficacy and broaden the neutralization spectrum of the antivenom.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  6. Lim PK, Yamasaki H, Mak JW, Wong SF, Chong CW, Yap IK, et al.
    Acta Trop, 2015 Aug;148:32-7.
    PMID: 25910623 DOI: 10.1016/j.actatropica.2015.04.011
    Human toxocariasis which is caused mainly by the larvae of Toxocara canis and Toxocara cati, is a worldwide zoonotic disease that can be a potentially serious human infection. The enzyme-linked immunosorbent assay (ELISA) using T. canis excretory-secretory (TES) antigens harvested from T. canis larvae is currently the serological test for confirming toxocariasis. An alternative to producing large amounts of Toxocara TES and improved diagnosis for toxocariasis is through the development of highly specific recombinant antigens such as the T. canis second stage larva excretory-secretory 30 kDa protein (recTES-30). The aim of this study was to evaluate the sensitivity and specificity of a rapid diagnostic kit (RDT, named as iToxocara kit) in comparison to recTES-30 ELISA in Serendah Orang Asli village in Selangor, Malaysia. A total of 133 subjects were included in the study. The overall prevalence rates by ELISA and RDT were 29.3% and 33.1%, respectively, with more positive cases detected in males than females. However, no association was found between toxocariasis and gender or age. The percentage sensitivity, specificity, positive predictive value and negative predictive value of RDT were 85.7%, 90.1%, 80% and 93.2%, respectively. The prevalence for toxocariasis in this population using both ELISA and RDT was 27.1% (36/133) and the K-concordance test suggested good agreement of the two tests with a Cohen's kappa of 0.722, P<0.01. In addition, the followed-up Spearman rank correlation showed a moderately high correlation at R=0.704 and P<0.01. In conclusion, the RDT kit was faster and easier to use than an ELISA and is useful for the laboratory diagnosis of hospitalized cases of toxocariasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  7. Archibald CP, Mak JW, Mathias RG, Selvajothi S
    Acta Trop, 1990 Dec;48(2):149-57.
    PMID: 1980570
    Indirect fluorescent antibody (IFA) tests and enzyme-linked immunosorbent assays (ELISA) were used to measure antibodies to Plasmodium falciparum in an indigenous population in an area of Malaysia with high malaria prevalence. The results of three surveys were analyzed to examine the relation of these serologic measures with age, parasite rate, and spleen size. For children 0-4 years old, increasing spleen size was associated with an increasing likelihood of malaria parasitemia, while for 5-9 year olds the two variables were unrelated. Parasite rate declined with age and ELISA titre increased with age in all surveys; IFA titre was consistently high and did not vary with age. Neither antibody measure was significantly correlated with either the presence or the actual density of parasitemia. These antibody measures are most useful as adjuncts to the more traditional techniques of malaria assessment.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  8. Balachandra D, Rahumatullah A, Lim TS, Mustafa FH, Ahmad H, Anuar NS, et al.
    Acta Trop, 2021 Sep;221:105986.
    PMID: 34058161 DOI: 10.1016/j.actatropica.2021.105986
    Serodiagnosis is an essential component of the laboratory diagnosis of Strongyloides infection and is usually performed using an indirect IgG antibody test. A direct antigen detection method can complement the IgG assay, particularly for detecting early infection and post-treatment follow-up. In the present study, a recombinant scFv monoclonal antibody against NIE recombinant protein (rMAb23) that we had previously produced was used to develop a Strongyloides antigen detection ELISA (SsAg-ELISA). The assay is based on detecting immune complexes of circulating NIE antigens bound to Strongyloides-specific IgG antibodies. The optimized ELISA parameters were 10 µg/mL of rMAb23 coated on microtitre plate wells, 2% skim milk as blocking reagent, 1:100 serum dilution, and 1:1000 goat anti-human IgG F(ab')2 conjugated to horseradish peroxidase. Four groups of serum samples were used, i.e., Strongyloides-positive serum samples categorized into Groups IA and IB; the former were from probable chronic infections and the latter from probable early/acute infections. Strongyloides-negative samples comprising Groups II (healthy samples) and III (other infections); the latter were from eleven different types of other parasitic infections. The receiver operating characteristic (ROC) curve showed an area under the curve (AUC) of 1.00, cut-off optical density (OD405) of 0.5002, and 100% diagnostic sensitivity and specificity. The results of the commercial IgG-ELISA and SsAg-ELISA from Group IA were found to be moderately correlated (r = 0.416; p 
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  9. Wong WK, Foo PC, Olivos-Garcia A, Noordin R, Mohamed Z, Othman N, et al.
    Acta Trop, 2017 Aug;172:208-212.
    PMID: 28506795 DOI: 10.1016/j.actatropica.2017.05.017
    Crude soluble antigen (CSA) produced from Entamoeba histolytica trophozoite is conventionally used for serodiagnosis of invasive amoebiasis. However, high background seropositivities by CSA-assay in endemic areas complicate the interpretation of positive result in clinical settings. Instead, incorporating a second assay which indicates active or recent infection into the routine amoebic serology could possibly complement the limitations of CSA-assay. Hence, the present study aimed to evaluate the diagnostic efficacies of indirect ELISAs using CSA and excretory-secretory antigen (ESA) for serodiagnosis of amoebic liver abscess (ALA). Reference standard for diagnosis of ALA at Hospital Universiti Sains Malaysia is based on clinical presentation, radiological imaging and positive indirect haemagglutination assay (titer ≥256). Five groups of human serum samples collected from the hospital included Group I - ALA diagnosed by the reference standard and pus aspirate analysis using real-time PCR (n=10), Group II - ALA diagnosed by the reference standard only (n=41), Group III - healthy control (n=45), Group IV - other diseases control (n=51) and Group V - other infectious diseases control (n=31). For serodiagnosis of ALA serum samples (Group I and II), CSA-ELISA showed sensitivities of 100% for both groups, while ESA-ELISA showed sensitivities of 100% and 88%, respectively. For serodiagnosis of non-ALA serum samples (Group III, IV and V), CSA-ELISA showed specificities of 91%, 75% and 100%, respectively; while ESA-ELISA showed specificities of 96%, 98% and 100%, respectively. Indirect ELISAs using CSA and ESA have shown distinct strength for serodiagnosis of ALA, in terms of sensitivity and specificity, respectively. In conclusion, parallel analysis by both assays improved the overall efficacies of amoebic serology as compared to either single assay.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  10. Khanbabaie S, Riazi M, Chang CH, Yunus MH, Noordin R
    Acta Trop, 2019 Feb;190:171-176.
    PMID: 30458123 DOI: 10.1016/j.actatropica.2018.11.018
    Cystic echinococcosis (CE) is a neglected zoonotic disease with a worldwide distribution and is a major public health problem in some areas. Diagnosis of CE is mainly based on clinical symptoms, imaging and serological testing, however, improvement in serodiagnosis is still needed. This study was aimed at detecting circulating Echinococcus antigen in CE patients using a lateral flow dipstick (LFD) assay. Three types of hydatid antigens i.e. hydatid cyst fluid (HCF), native antigen B (nAgB) and recombinant antigen B (rAgB) were prepared and polyclonal rabbit antiserum was raised against each antigen. Purified IgG fractions were prepared and a portion was conjugated to gold nanoparticles. After a series of optimizations, a final antigen detection LFD assay was developed using a combination of anti-nAgB-IgG and gold-conjugated anti-HCF-IgG. Evaluation of the assay showed that 27 out of 35 (77%) serum samples from CE patients gave positive results. Meanwhile, the test showed a diagnostic specificity of 82% when tested with sera from 38 healthy individuals and 13 patients with other parasitic diseases. In conclusion, the antigen detection LFD assay seemed to be useful for diagnosis of CE and possibly for post-treatment follow-up, and merit further evaluation studies. We foresee that it may improve serodiagnosis of CE when used in tandem with an antibody detection test.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  11. Noordin R, Osman E, Kalantari N, Anuar NS, Gorgani-Firouzjaee T, Sithithaworn P, et al.
    Acta Trop, 2022 Feb;226:106251.
    PMID: 34808116 DOI: 10.1016/j.actatropica.2021.106251
    Strongyloides stercoralis is a parasite that causes strongyloidiasis worldwide. It may lead to a life-long infection in immunocompetent people and hyperinfection in immunosuppressed patients. A point-of-care (POC) rapid test is helpful for patient diagnosis in resource-limited settings and as a detection tool in elimination/control programs. Previously, we reported a rapid IgG4 dipstick test (Ss Rapid®) for Strongyloides suitable for a laboratory setting. A POC cassette format of the test, which is field-applicable, has since been developed. Here, we report on a laboratory-based evaluation of the Ss Rapid® cas sette test on 285 sera. We assessed the diagnostic sensitivity of the Ss Rapid® cas sette with 32 sera, comprising samples from larval and/or DNA positive individuals from three countries. Additionally, we also tested samples from 33 seropositive endemic areas residents. We evaluated the diagnostic specificity of the test using 220 samples, comprising sera from other infections (n = 101), allergy cases with high IgE antibodies (n = 4), and blood donors (n = 115). The test showed high diagnostic sensitivity (97%, 31/32), and all sera of the seropositive endemic residents were reactive. It also showed high diagnostic specificity (94.5%, 208/220), and all false-positive samples tested negative after sera adsorption using recombinant NIE-coated microsphere beads. Additionally, we showed that the test worked with spiked whole blood samples. The study results showed that the SsRapid® cas sette test merits further laboratory and field evaluations.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  12. Ch'ng WC, Saw WT, Yusoff K, Shafee N
    Acta Virol., 2011;55(3):227-33.
    PMID: 21978156
    Enterovirus 71 (EV71) is one of the viruses that cause hand, foot and mouth disease. Its viral capsid protein 1 (VP1), which contains many neutralization epitopes, is an ideal target for vaccine development. Recently, we reported the induction of a strong immune response in rabbits to a truncated VP1 fragment (Nt-VP1t) displayed on a recombinant Newcastle disease virus (NDV) capsid protein. Protective efficacy of this vaccine, however, can only be tested in mice, since all EV71 animal models thus far were developed in mouse systems. In this study, we evaluated the type of immune responses against the protein developed by adult BALB/c mice. Nt-VP1t protein induced high levels of VP1 IgG antibody production in mice. Purified VP1 antigen stimulated activation, proliferation and differentiation of splenocytes harvested from these mice. They also produced significant levels of IFN-γ, a Th1-related cytokine. Taken together, Nt-VP1t protein is a potent immunogen in adult mice and our findings provide the data needed for testing of its protective efficacy in mouse models of EV71 infections.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  13. Loh HS, Mohd-Azmi ML, Sheikh-Omar AR, Zamri-Saad M, Tam YJ
    Acta Virol., 2007;51(1):27-33.
    PMID: 17432941
    The present study described the kinetics of Rat cytomegalovirus (RCMV) infection in newborn rats by monitoring infectious virus and viral antigens in various organs, viral DNA in the blood (DNAemia) and antibody response. These parameters were evaluated quantitatively using double-antibody sandwich ELISA (DAS-ELISA), real-time PCR, indirect ELISA and virus infectivity assay. For the first time DAS-ELISA was used for detection of RCMV antigen directly from organ samples. The relationships between the presence of viral antigens in the infected organs and antibody levels were established by the Spearman's rank test. It was found that the virus was present in the blood, spleen, liver, lungs, and kidneys earlier than in the salivary glands. Furthermore, the early immunity of the newborn rats led to a delayed seroconversion. We suggested that the prolonged presence of the virus in salivary glands could augment the antibody response that conversely might be responsible for a reduction of viremia. This study expanded our understanding of RCMV pathogenesis leading to improved therapeutic and preventive treatment regimens particularly for the neonatal Human cytomegalovirus (HCMV) infections. Additionally, the detection procedures developed in this study such as DAS-ELISA and real-time PCR could serve as alternative techniques for rapid screening of large number of samples.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  14. Noordin R, Yunus MH, Tan Farrizam SN, Arifin N
    Adv Parasitol, 2020;109:131-152.
    PMID: 32381194 DOI: 10.1016/bs.apar.2020.01.003
    Toxocariasis is a human infection primarily caused by larvae of Toxocara canis from dogs, and also by T. cati from cats. Children have a more significant risk of acquiring the infection due to their closer contact with pets, and greater chances of ingesting soil. Diagnosis of toxocariasis is based on clinical, epidemiological, and serological data. Indirect IgG ELISA is a widely used serodiagnostic method for toxocariasis, with native T. canis TES most commonly used as the antigen. Western blots, using the same antigen, can be used to confirm positive ELISA findings to reduce false-positive results. Improvements in Toxocara serodiagnosis include the use of recombinant TES antigens, simpler and more rapid assay formats, and IgG4 subclass detection. Also, incorporation of recombinant T. cati TES protein increases the diagnostic sensitivity. Development of antigen detection tests using polyclonal and monoclonal antibodies, nanobodies, or aptamers can complement the antibody detection assays, and enhance the effectiveness of the serodiagnosis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  15. Hudu SA, Harmal NS, Saeed MI, Alshrari AS, Malik YA, Niazlin MT, et al.
    Afr Health Sci, 2016 Sep;16(3):677-683.
    PMID: 27917199
    BACKGROUND: Occult hepatitis B infections are becoming a major global threat, but the available data on its prevalence in various parts of the world are often divergent.

    OBJECTIVE: This study aimed to detect occult hepatitis B virus in hepatitis B surface antigen-negative serum using anti-HBc as a marker of previous infection.

    PATIENT AND METHODS: A total of 1000 randomly selected hepatitis B surface antigen-negative sera from blood donors were tested for hepatitis B core antibody and hepatitis B surface antibody using an ELISA and nested polymerase chain reaction was done using primers specific to the surface gene (S-gene).

    RESULTS: Of the 1000 samples 55 (5.5%) were found to be reactive, of which 87.3% (48/55) were positive for hepatitis B surface antibody, indicating immunity as a result of previous infection however, that does not exclude active infection with escaped mutant HBV. Nested PCR results showed the presence of hepatitis B viral DNA in all the 55 samples that were positive for core protein, which is in agreement with the hepatitis B surface antibody result.

    CONCLUSION: This study reveals the 5.5% prevalence of occult hepatitis B among Malaysian blood donors as well as the reliability of using hepatitis B core antibody in screening for occult hepatitis B infection in low endemic, low socioeconomic settings.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  16. Yeang HY, Ward MA, Zamri AS, Dennis MS, Light DR
    Allergy, 1998 May;53(5):513-9.
    PMID: 9636811
    Separate studies have reported spina bifida patients to be especially allergic to proteins of 27 and 23 kDa found in the serum of centrifuged natural rubber latex. An insoluble latex protein located on the surface of small rubber particles, Hev b 3, has similarly been found to be allergenic to spina bifida patients. In this study, internal amino acid sequences of Hev b 3 showed similarity to the published sequences for the 27- and 23-kDa latex proteins. The latter allergens are hence identified as Hev b 3. Determination of the molecular weight of Hev b 3 revealed various species of 22-23 kDa. The consistent gaps of about 266 Da observed between various forms of the intact protein suggest that the protein undergoes post-translational modification. To determine whether Hev b 3 also occurs in a soluble form in the latex serum, its presence in molecular-filtered serum was checked by ELISA and Western blot. The results showed Hev b 3 to be largely absent in the C-serum from fresh latex. The protein is therefore insoluble in its native state. However, a small amount of the solubilized protein was detected in ammonia-stabilized latex (commonly used in the manufacture of latex products).
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  17. Abdulamir AS, Hafidh RR, Abu Bakar F, Abbas K
    Am J Otolaryngol, 2010 Nov-Dec;31(6):410-7.
    PMID: 20015794 DOI: 10.1016/j.amjoto.2009.06.006
    PURPOSE: This study was designed to find a reliable Epstein-Barr virus (EBV) immunoglobulin (Ig) G-based diagnostic/screening test for nasopharyngeal carcinoma (NPC) able to demarcate between the NPC-related seropositivity of EBV IgG antibodies and that of other head and neck cancer (HNCA) and control groups. The NPC-associated immunosuppression affects EBV IgA much more than IgG, leading to inconsistent detection of NPC using EBV IgA antibodies.
    MATERIALS AND METHODS: One hundred twenty-two HNCA patients, 42 NPC, 66 laryngeal carcinoma, and 14 hypopharyngeal carcinoma and 3 groups of 100 control subjects were enrolled in this study. Enzyme-linked immunosorbent assay (ELISA) was used to find a specific cutoff value for the NPC-related seropositivity of EBV IgG antibodies.
    RESULTS: NPC group showed higher serum level of EBV IgG antibodies than control and other HNCA groups (P < .05). However, the traditional cutoff value, mean + 2 SDs of control subjects, failed to demarcate the seropositives of NPC patients from those of healthy population (P > .05). The new cutoff value, mean + 2 SDs of the seropositives group of control subjects who had already been grouped by the traditional cutoff value, proved successful. It succeeded to demarcate between the NPC-related EBV IgG seropositivity and that issued from the persistent, latent, or reactivated EBV infection in the population (P < .05). The sensitivity/specificity of NPC detection by the new cutoff-based ELISA kit, 76.19% and 86%, was close or higher than that of EBV IgA antibodies.
    CONCLUSION: EBV IgG-based ELISA could be used for the diagnosis of NPC using a new cutoff threshold that excludes the population baseline of EBV IgG seropositivity.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  18. Zhang R, Wang S, Huang X, Yang Y, Fan H, Yang F, et al.
    Anal Chim Acta, 2020 Jan 15;1094:142-150.
    PMID: 31761041 DOI: 10.1016/j.aca.2019.10.012
    α-synuclein is a predominantly expressing neuronal protein for understanding the neurodegenerative disorders. A diagnosing system with aggregated α-synuclein encoded by SNCA gene is necessary to make the precautionary treatment against Parkinson's disease (PD). Herein, gold-nanourchin conjugated anti-α-synuclein antibody was desired as the probe and seeded on single-walled carbon nanotube (SWCN) integrated interdigitated electrode (IDE). The surface morphology of SWCN-modified IDE and gold urchin-antibody conjugates were observed under FESEM, FETEM and AFM, the existing elements were confirmed. Voltammetry analysis revealed that the limit of fibril-formed α-synuclein detection was improved by 1000 folds (1 fM) with gold-nanourchin-antibody modified surface, compared to the surface with only antibody (1 pM). Validating the interaction of α-synuclein by Enzyme-linked Immunosorbent Assay was displayed the detection limit as 10 pM. IDE has a good reproducibility and a higher selectivity on α-synuclein as evidenced by the interactive analysis with the control proteins, PARK1 and DJ-1.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  19. Lee MJ, Ramanathan S, Mansor SM, Tan SC
    Anal Biochem, 2020 06 15;599:113733.
    PMID: 32302607 DOI: 10.1016/j.ab.2020.113733
    An enzyme-linked immunosorbent assay for detection of mitragynine, other closely related Kratom alkaloids and metabolites was developed using polyclonal antibodies. Mitragynine was conjugated to a carrier protein, cationized-bovine serum albumin using Mannich reaction. The synthesized antigen was injected into rabbits to elicit specific polyclonal antibodies against mitragynine. An enzyme conjugate was synthesized for evaluating its performance with the antibodies produced. The assay had an IC50 of 7.3 ng/mL with a limit of detection of 15 ng/mL for mitragynine. Antibody produced have high affinity for mitragynine (100%), other closely related Kratom alkaloids such as paynantheine (54%), speciociliatine (63%), 7α-hydroxy-7H-mitragynine (83%) and cross-reacted with metabolites 9-O-demethyl mitragynine (79%), 16-carboxy mitragynine (103%), 9-O-demethyl mitragynine sulfate (263%), 9-O-demethyl mitragynine glucuronide (60%), 16-carboxy mitragynine glucuronide (60%), 9-O-demethyl-16-carboxy mitragynine sulfate (270%) and 17-O-demethyl-16,17-dihydro mitragynine glucuronide (34%). It showed cross-reactivity less than 0.01% to reserpine, codeine, morphine, caffeine, methadone, amphetamine, and cocaine. Ten-fold dilution urine was used in the assay to reduce the matrix effects. The recovery ranged from 83% to 112% with variation coefficients in intraday and interday less than 8% and 6%, respectively. The ELISA turned out to be a convenient tool to diagnose mitragynine, other closely related Kratom alkaloids and metabolites in human urine samples.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  20. Heidari MH, Movafagh A, Abdollahifar MA, Abdi S, Barez MM, Azimi H, et al.
    Anat Cell Biol, 2017 Mar;50(1):69-72.
    PMID: 28417057 DOI: 10.5115/acb.2017.50.1.69
    Prostate cancer is the most common cancer type in men and is the second cause of death, due to cancer, in patients over 50, after lung cancer. Prostate specific antigen (PSA) is a widely used tumor marker for prostate cancer. Recently, PSA is discovered in non-prostatic cancer tissues in men and women raising doubts about its specificity for prostatic tissues. PSA exists in low serum level in healthy men and in higher levels in many prostate disorders, including prostatitis and prostate cancer. Thus, a supplementary tumor marker is needed to accurately diagnose the cancer and to observe the patient after treatment. Recently, soluble human leukocyte antigen-G (sHLA-G) has been introduced as a new tumor marker for different cancer types, including colorectal, breast, lung, and ovary. The present descriptive-experimental study was carried out including patients with malignant prostate tumor, patients with benign prostate tumor, and a group of health men as the control group, as judged by an oncologist as well as a pathologist. After sterile blood sampling, sHLA-G was measured by enzyme-linked immunosorbent assay in each group. The data was then analyzed using one-way ANOVA. P≤0.05 was considered as statistically significant. The results showed that the mean of sHLA-G level was high in patients. Also, it was found that there was a significant difference in sHLA serum level between the three groups. The data revealed that sHLA-G can be a novel supplementary tumor marker in addition to PSA to diagnose prostate cancer.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links