Displaying publications 1 - 20 of 597 in total

Abstract:
Sort:
  1. Thiha A, Ibrahim F
    Sensors (Basel), 2015;15(5):11431-41.
    PMID: 25993517 DOI: 10.3390/s150511431
    The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/instrumentation*
  2. Ch'ng ACW, Ahmad A, Konthur Z, Lim TS
    Methods Mol Biol, 2019;1904:377-400.
    PMID: 30539481 DOI: 10.1007/978-1-4939-8958-4_18
    Panning is a common process used for antibody selection from phage antibody libraries. There are several methods developed for a similar purpose, namely streptavidin mass spectrometry immunoassay (MSIA™) Disposable Automation Research Tips, magnetic beads, polystyrene immunotubes, and microtiter plate. The advantage of using a magnetic particle processor system is the ability to carry out phage display panning against multiple target antigens simultaneously in parallel. The system carries out the panning procedure using magnetic nanoparticles in microtiter plates. The entire incubation, wash, and elution process is then automated in this setup. The system also allows customization for the introduction of different panning stringencies. The nature of the biopanning process coupled with the limitation of the system means that minimal human intervention is required for the infection and phage packaging stage. However, the process still allows for rapid and reproducible antibody generation to be carried out.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  3. Hosseini S, Azari P, Cardenas-Benitez B, Martínez-Guerra E, Aguirre-Tostado FS, Vázquez-Villegas P, et al.
    Mater Sci Eng C Mater Biol Appl, 2020 Apr;109:110629.
    PMID: 32228934 DOI: 10.1016/j.msec.2020.110629
    Based on the concept of LEGO toys, a fiber probe analytical platform (FPAP) was developed as a powerful diagnostic tool offering higher sensitivity in detection of infectious agents compared to established methods. Using the form and the function of LEGO toys, this protocol describes a fiber-based, 96-well plate, which suspends a new class of chemically-designed, electrospun fibers within the assay. This clamping strategy allows both sides of the developed fiber mats to interact with biomolecules within the assay thus benefiting from the tailored chemical and physical properties of these fiber-based bioreceptors in attracting the biomolecules to the surface. The fabrication method of FPAP involves one-step electrospinning of the chemically designed fibers, 3D printing of the LEGO-like probing segments, and assembly of the device followed by ELISA procedure. FPAP follows the same principles of operation as that of a conventional enzyme linked immunosorbent assay (ELISA), therefore, it can be run by lab technicians, expert in ELISA. FPAP was used for early diagnosis of Dengue fever and provided an 8-fold higher sensitivity while the limit of detection (LOD) was recorded to be in femto-gram per milliliter range which is significantly low when compared to other existing techniques or conventional assay. This platform allows different types of paper/fiber bio-receptive platforms to be incorporated within the design that promises simultaneous recognition of multiple infectious agents.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  4. Yunus MH, Tan Farrizam SN, Abdul Karim IZ, Noordin R
    Am J Trop Med Hyg, 2018 Jan;98(1):32-38.
    PMID: 29141740 DOI: 10.4269/ajtmh.17-0632
    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara-positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  5. Chua KB, Mustafa B, Abdul Wahab AH, Chem YK, Khairul AH, Kumarasamy V, et al.
    Malays J Pathol, 2011 Jun;33(1):13-20.
    PMID: 21874746
    A prospective study was carried out to evaluate the sensitivity of dengue NS1 antigen-capture ELISA in comparison with dengue virus isolation, conventional RT-PCR and real-time RT-PCR for laboratory confirmation of acute dengue based on single-acute serum samples. Four primary healthcare centres were involved to recruit patients with clinical diagnosis of dengue illness. Patient's demographic, epidemiological and clinical information were collected on a standardized data entry form and 5 ml of venous blood was collected upon consent. In the laboratory, six types of laboratory tests were performed on each of the collected acute serum sample. Of the 558 acute serum samples collected from 558 patients with clinical diagnosis of dengue from mid-August 2006 to March 2009, 174 serum samples were tested positive by the dengue NS1 antigen-capture ELISA, 77 by virus isolation, 92 by RT-PCR and 112 by real-time RT-PCR. A total of 190 serum samples were tested positive by either one or a combination of the four methods whereas, only 59 serum samples were tested positive by all four methods. Thus, based on single-acute serum samples, 190 of the 558 patients (34.1%) were laboratory-confirmed acute dengue. The overall test sensitivity was 91.6%, 40.5%, 48.4% and 58.9% for dengue NS1 antigen-capture ELISA, virus isolation, conventional RT-PCR and real-time RT-PCR respectively. Statistically, dengue NS1 antigen-capture ELISA was the most sensitive and virus isolation was the least sensitive test for the laboratory confirmation of acute dengue based on single-acute serum specimens. Real-time RT-PCR was significantly more sensitive than the conventional RT-PCR.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  6. Hassan MR, Mustapha NR, Zawawi FM, Earnest BS, Voralu K, Pani SP
    Singapore Med J, 2011 Feb;52(2):86-9.
    PMID: 21373733
    This study was conducted to compare the genotype and markers of disease severity of chronic hepatitis C (CHC), namely viral load, alanine transaminase (ALT) levels and histopathological findings on liver biopsy, in patients with and without end-stage renal disease (ESRD).
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  7. Siew QY, Tan SH, Pang EL, Loh HS, Tan MTT
    Analyst, 2021 Mar 21;146(6):2009-2018.
    PMID: 33523052 DOI: 10.1039/d0an02219e
    The envelope glycoprotein domain III (EDIII) of dengue virus (DENV) has been recognised as the antigenic region responsible for receptor binding. In the present work, we have proposed a novel immunosensor constructed on a graphene-coated screen-printed carbon electrode (SPCE) using plant-derived EDIII as the probe antigen to target DENV IgG antibodies. The developed immunosensor demonstrated high sensitivity towards DENV IgG within a wide linear working range (125-2000 ng mL-1) under the optimised sensing conditions. The limit of detection was determined to be 22.5 ng mL-1. The immunosensor also showed high specificity towards DENV IgG, capable of differentiating DENV IgG from the antibodies of other infectious diseases including the similarly structured Zika virus (ZIKV). The ability of the immunosensor to detect dengue antibodies in serum samples was also verified by conducting tests on mouse serum samples. The proposed immunosensor was able to provide a binary (positive/negative) response towards the serum samples comparable to the conventional enzyme-linked immunosorbent assay (ELISA), indicating promising potential for realistic applications.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  8. Mathew A, Cheng HM, Sam CK, Joab I, Prasad U, Cochet C
    Cancer Immunol Immunother, 1994 Jan;38(1):68-70.
    PMID: 8299121
    The BamHI Z EBV replication activator (ZEBRA) protein is involved in the switch from latency to productive cycle of Epstein-Barr virus. A recombinant ZEBRA protein was synthesized and assessed in enzyme-linked immunosorbent assay (ELISA) for serum IgG response in nasopharyngeal carcinoma (NPC) patients. In 100 NPC serum samples that were positive for IgA to the EBV viral capsid antigen (VCA), 75% had IgG anti-ZEBRA antibodies. In contrast, only 3/83 (3.6%) serum samples from healthy donors and 2/50 (4%) from other cancers were positive for IgG to ZEBRA. Interestingly, in a selected group of 100 NPC sera negative for IgA to VCA, 25% contained IgG anti-ZEBRA antibodies. This suggests that the ELISA for IgG anti-ZEBRA may also identify earlier cases of NPC not detected by the conventional immunofluorescence test for IgA to VCA.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  9. Vythilingam I, Nitiavathy K, Yi P, Bakotee B, Hugo B, Singh B, et al.
    PMID: 10928352
    Dried Anopheles farauti mosquitos caught in Solomon Islands in 1990 were examined for malaria sporozoites by ELISA and nested polymerase chain reaction (PCR). Only heads and thoraces were used. Plasmodium genus-specific nested PCR amplifications were carried out on all samples. Of the 402 pools of mosquitos that were processed, 30 were positive for malaria. Nest 1 products of positive samples were subjected to further PCR amplifications with species-specific primers for P. falciparum and P. vivax. Twenty pools were positive for P. vivax by PCR while only 7 were positive by ELISA. For P. falciparum 2 pools were positive by both ELISA and PCR, and one of these was a pool which was positive for P. vivax by PCR and ELISA. Thus the sensitivity of PCR for P. vivax was 100% while the specificity was 96.7%. For P. falciparum the sensitivity and specificity were 100%. The PCR technique is highly sensitive and can be used on dried mosquitos which makes it a valuable tool for determining sporozoite rates of mosquitos, even in remote areas.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  10. Bakar AF, Alitheen NB, Keong YS, Hamid M, Ali SA, Ali AM
    Hybridoma (Larchmt), 2009 Jun;28(3):199-203.
    PMID: 19519247 DOI: 10.1089/hyb.2007.0531
    Hybridoma clone C3A8, which is a fusion product between splenic lymphocytes of Balb/c mice immunized with MCF7 breast carcinoma cells and SP2/0 myelomas, was produced and characterized. A stable clone that secreted IgM monoclonal antibody (MAb) with kappa light chain was obtained through limiting dilutions. Cell-ELISA screening, flow cytometry analysis, and immunofluorescence staining revealed that the MAb C3A8 had bound specifically and strongly to MCF7 and HT29 but cross reacted weakly or not on HeLa cell line. The MAb C3A8 reacted positively with paraffin-embedded tissues of human breast and colon cancers but there were no positive reactions on normal tissues. Western blot analysis showed the MAb recognized a 55 kDa protein, which was present in the extract of MCF7 and HT29 cell lines. Our results demonstrated that MAb C3A8 could be used for basic and clinical research of breast and colon cancers.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  11. Balachandra D, Rahumatullah A, Lim TS, Mustafa FH, Ahmad H, Anuar NS, et al.
    Acta Trop, 2021 Sep;221:105986.
    PMID: 34058161 DOI: 10.1016/j.actatropica.2021.105986
    Serodiagnosis is an essential component of the laboratory diagnosis of Strongyloides infection and is usually performed using an indirect IgG antibody test. A direct antigen detection method can complement the IgG assay, particularly for detecting early infection and post-treatment follow-up. In the present study, a recombinant scFv monoclonal antibody against NIE recombinant protein (rMAb23) that we had previously produced was used to develop a Strongyloides antigen detection ELISA (SsAg-ELISA). The assay is based on detecting immune complexes of circulating NIE antigens bound to Strongyloides-specific IgG antibodies. The optimized ELISA parameters were 10 µg/mL of rMAb23 coated on microtitre plate wells, 2% skim milk as blocking reagent, 1:100 serum dilution, and 1:1000 goat anti-human IgG F(ab')2 conjugated to horseradish peroxidase. Four groups of serum samples were used, i.e., Strongyloides-positive serum samples categorized into Groups IA and IB; the former were from probable chronic infections and the latter from probable early/acute infections. Strongyloides-negative samples comprising Groups II (healthy samples) and III (other infections); the latter were from eleven different types of other parasitic infections. The receiver operating characteristic (ROC) curve showed an area under the curve (AUC) of 1.00, cut-off optical density (OD405) of 0.5002, and 100% diagnostic sensitivity and specificity. The results of the commercial IgG-ELISA and SsAg-ELISA from Group IA were found to be moderately correlated (r = 0.416; p 
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  12. Müller-Sienerth N, Shilts J, Kadir KA, Yman V, Homann MV, Asghar M, et al.
    Malar J, 2020 Jan 17;19(1):31.
    PMID: 31952523 DOI: 10.1186/s12936-020-3111-5
    BACKGROUND: Malaria remains a global health problem and accurate surveillance of Plasmodium parasites that are responsible for this disease is required to guide the most effective distribution of control measures. Serological surveillance will be particularly important in areas of low or periodic transmission because patient antibody responses can provide a measure of historical exposure. While methods for detecting host antibody responses to Plasmodium falciparum and Plasmodium vivax are well established, development of serological assays for Plasmodium knowlesi, Plasmodium ovale and Plasmodium malariae have been inhibited by a lack of immunodiagnostic candidates due to the limited availability of genomic information.

    METHODS: Using the recently completed genome sequences from P. malariae, P. ovale and P. knowlesi, a set of 33 candidate cell surface and secreted blood-stage antigens was selected and expressed in a recombinant form using a mammalian expression system. These proteins were added to an existing panel of antigens from P. falciparum and P. vivax and the immunoreactivity of IgG, IgM and IgA immunoglobulins from individuals diagnosed with infections to each of the five different Plasmodium species was evaluated by ELISA. Logistic regression modelling was used to quantify the ability of the responses to determine prior exposure to the different Plasmodium species.

    RESULTS: Using sera from European travellers with diagnosed Plasmodium infections, antigens showing species-specific immunoreactivity were identified to select a panel of 22 proteins from five Plasmodium species for serological profiling. The immunoreactivity to the antigens in the panel of sera taken from travellers and individuals living in malaria-endemic regions with diagnosed infections showed moderate power to predict infections by each species, including P. ovale, P. malariae and P. knowlesi. Using a larger set of patient samples and logistic regression modelling it was shown that exposure to P. knowlesi could be accurately detected (AUC = 91%) using an antigen panel consisting of the P. knowlesi orthologues of MSP10, P12 and P38.

    CONCLUSIONS: Using the recent availability of genome sequences to all human-infective Plasmodium spp. parasites and a method of expressing Plasmodium proteins in a secreted functional form, an antigen panel has been compiled that will be useful to determine exposure to these parasites.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  13. Tan WS, Tan GH, Yusoff K, Seow HF
    J Clin Virol, 2005 Sep;34(1):35-41.
    PMID: 16087122
    The surface antigen (HBsAg) of hepatitis B virus (HBV) is highly conformational and generally evokes protective humoral immune response in human. A disulfide constrained random heptapeptide library displayed on the coat protein III of filamentous bacteriophage M13 was employed to select specific ligands that interact with HBsAg subtype ad. Fusion phages carrying the amino acid sequence ETGAKPH and other related sequences were isolated. The binding site of peptide ETGAKPH was located on the immunodominant region of HBsAg. An equilibrium binding assay in solution showed that the phage binds tightly to HBsAg with a relative dissociation constant (KDrel) of 2.9+/-0.9 nM. The phage bearing this peptide has the potential to be used as a diagnostic reagent and two assays for detecting HBsAg in blood samples are described.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  14. Noordin R, Osman E, Kalantari N, Anuar NS, Gorgani-Firouzjaee T, Sithithaworn P, et al.
    Acta Trop, 2022 Feb;226:106251.
    PMID: 34808116 DOI: 10.1016/j.actatropica.2021.106251
    Strongyloides stercoralis is a parasite that causes strongyloidiasis worldwide. It may lead to a life-long infection in immunocompetent people and hyperinfection in immunosuppressed patients. A point-of-care (POC) rapid test is helpful for patient diagnosis in resource-limited settings and as a detection tool in elimination/control programs. Previously, we reported a rapid IgG4 dipstick test (Ss Rapid®) for Strongyloides suitable for a laboratory setting. A POC cassette format of the test, which is field-applicable, has since been developed. Here, we report on a laboratory-based evaluation of the Ss Rapid® cas sette test on 285 sera. We assessed the diagnostic sensitivity of the Ss Rapid® cas sette with 32 sera, comprising samples from larval and/or DNA positive individuals from three countries. Additionally, we also tested samples from 33 seropositive endemic areas residents. We evaluated the diagnostic specificity of the test using 220 samples, comprising sera from other infections (n = 101), allergy cases with high IgE antibodies (n = 4), and blood donors (n = 115). The test showed high diagnostic sensitivity (97%, 31/32), and all sera of the seropositive endemic residents were reactive. It also showed high diagnostic specificity (94.5%, 208/220), and all false-positive samples tested negative after sera adsorption using recombinant NIE-coated microsphere beads. Additionally, we showed that the test worked with spiked whole blood samples. The study results showed that the SsRapid® cas sette test merits further laboratory and field evaluations.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  15. Osman O, Fong MY, Devi S
    Jpn J Infect Dis, 2007 Jul;60(4):205-8.
    PMID: 17642533
    The purpose of this study was to examine the extent of dengue infection in Brunei and to determine the predominant serotype circulating in the country. The study generated useful epidemiological data on dengue infection in Brunei. A total of 271 samples from patients suspected of having dengue infections were selected and analyzed. All patients were seen in clinics and hospitals in Brunei. The samples were collected from April 2005 to April 2006 and transported to the WHO Collaborating Centre for Arbovirus Reference and Research, University of Malaya, Malaysia. The following tests were used to achieve the objectives: in-house IgM-capture enzyme-linked immunosorbent assay, virus isolation in mosquito albopictus cell line (C6/36), and viral RNA detection and serotyping by reverse transcriptase-polymerase chain reaction (RT-PCR). The results show that 45 people were positive for dengue-specific IgM (27 males and 18 females), while RT-PCR detected dengue viral RNA in 12 patients, 3 identified as DEN-1 and 9 as DEN-2. Dengue virus was isolated from 6 patients using the C6/36 cell line; 3 were DEN-2 isolates and 3 were DEN-1 isolates. These data show that dengue virus is circulating in Brunei and the predominant infecting serotype for that period was DEN-2 followed by DEN-1. This study is the first to report the detection and isolation of dengue virus from Brunei using RT-PCR and culture in the C6/36 albopictus mosquito cell line.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  16. Samsudin NI, Abdullah N
    Mycotoxin Res, 2013 May;29(2):89-96.
    PMID: 23242851 DOI: 10.1007/s12550-012-0154-7
    Red rice is a fermented product of Monascus spp. It is widely consumed by Malaysian Chinese who believe in its pharmacological properties. The traditional method of red rice preparation disregards safety regulation and renders red rice susceptible to fungal infestation and mycotoxin contamination. A preliminary study was undertaken aiming to determine the occurrence of mycotoxigenic fungi and mycotoxins contamination on red rice at consumer level in Selangor, Malaysia. Fifty red rice samples were obtained and subjected to fungal isolation, enumeration, and identification. Citrinin, aflatoxin, and ochratoxin-A were quantitated by ELISA based on the presence of predominant causal fungi. Fungal loads of 1.4 × 10(4) to 2.1 × 10(6) CFU/g exceeded Malaysian limits. Monascus spp. as starter fungi were present in 50 samples (100%), followed by Penicillium chrysogenum (62%), Aspergillus niger (54%), and Aspergillus flavus (44%). Citrinin was present in 100% samples (0.23-20.65 mg/kg), aflatoxin in 92% samples (0.61-77.33 μg/kg) and Ochratoxin-A in 100% samples (0.23-2.48 μg/kg); 100% citrinin and 76.09% aflatoxin exceeded Malaysian limits. The presence of mycotoxigenic fungi served as an indicator of mycotoxins contamination and might imply improper production, handling, transportation, and storage of red rice. Further confirmatory analysis (e.g., HPLC) is required to verify the mycotoxins level in red rice samples and to validate the safety status of red rice.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  17. Ho CW, Tan WS, Chong FC, Ling TC, Tey BT
    J Microbiol Biotechnol, 2009 Apr;19(4):416-23.
    PMID: 19421000
    Hepatitis B core antigen (HBcAg) is an important serological marker used in the diagnosis of hepatitis B virus (HBV) infections. In the current study, a fast and efficient preparative purification protocol for truncated HBcAg from Escherichia coli disruptate was developed. The recombinant HBcAg was first captured by anion exchange expanded bed adsorption chromatography integrated with a cell disruption process. This online capture process has shortened the process time and eliminated the "hold-up" period that may be detrimental to the quality of target protein. The eluted product from the expanded bed adsorption chromatography was subsequently purified using size-exclusion chromatography. The results showed that this novel purification protocol achieved a recovery yield of 45.1% with a product purity of 88.2%, which corresponds to a purification factor of 4.5. The recovered HBcAg is still biologically active as shown by ELISA test.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  18. Lee M, Harrison BA, Lewis GE
    Am J Trop Med Hyg, 1990 Apr;42(4):314-9.
    PMID: 2184690 DOI: 10.4269/ajtmh.1990.42.314
    A modified version of the standard 2-site sporozoite enzyme-linked immunosorbent assay (ELISA) using 3,3',5,5'-tetramethylbenzidine (TMB) as the substrate chromogen solution was adapted for rapid detection and identification of Plasmodium falciparum and P. vivax circumsporozoite (CS) proteins. The TMB-ELISA was evaluated using sporozoites from experimentally infected mosquitoes and laboratory colonized uninfected mosquitoes. Our data indicate comparable sensitivity levels between the TMB-ELISA and the standard ELISA, i.e., 50 P. falciparum or P. vivax sporozoites/50 microliters of test solution. Reactions inherent to the method were specific and background reactivity was minimal. The TMB-ELISA is rapid (1 hr), simple, uses a minimal amount of monoclonal antibodies, and is suitable for use in a wide range of laboratories.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay
  19. Muniandy S, Qvist R, Zaini A, Chinna K, Ismail IS
    PMID: 16295560
    The concentration of plasma sialic acid was estimated using the modified chemical method and the more sensitive enzymatic method in 20 subjects with impaired glucose tolerance and 20 control subjects. The mean sialic acid concentration values of the control subjects and subjects with impaired glucose tolerance using the enzymatic method were 1.747 +/- 0.047 and 2.583 +/- 0.070 mmole/l and 1.753 +/- 0.067 and 2.591 +/- 1.02 mmole/l for the chemical method. The intra-assay coefficient of variation for the control subjects and for the subjects with impaired glucose tolerance were 1.963% and 1.583%, respectively, for the enzymatic assay and 2.728% and 2.431%, respectively, for the chemical assay. The inter-assay coefficient of variation for the control subjects and for the subjects with impaired glucose tolerance were 2.686% and 2.723% for the enzymatic assay, and 3.819% and 3.95% for the chemical assay. Since the values do not differ significantly, the chemical assay is a cost effective method that can be used in large epidemiological studies.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  20. Rahmah N, Lim BH, Khairul Anuar A, Shenoy RK, Kumaraswami V, Lokman Hakim S, et al.
    Trans R Soc Trop Med Hyg, 2001 8 9;95(3):280-4.
    PMID: 11490997
    An IgG4 ELISA based on a novel recombinant antigen was evaluated for detection of Brugia malayi infection, using 2487 sera from various institutions: 2031 samples from Universiti Sains Malaysia, 276 blinded sera from 2 other institutions in Malaysia, 140 blinded sera from India and 40 blinded sera from Thailand. These sera were from various groups of individuals, i.e., microfilaraemics, chronic patients, endemic normals, non-endemic normals and individuals with other parasitic and bacterial infections. Based on a cut-off optical density reading of 0.300, the IgG4 ELISA demonstrated specificity rates of 95.6-100%, sensitivity rates of 96-100%, positive predictive values of 75-100% and negative predictive values of 98.9-100%. These evaluation studies demonstrated the high specificity and sensitivity of this test for the detection of active B. malayi infection. Thus, the IgG4 ELISA would be very useful as a tool in diagnosis and in elimination programmes for brugian filariasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*; Enzyme-Linked Immunosorbent Assay/standards
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links