Displaying publications 1 - 20 of 106 in total

Abstract:
Sort:
  1. Zeehaida M, Wan Nor Amilah WA, Amry AR, Hassan S, Sarimah A, Rahmah N
    Trop Biomed, 2008 Dec;25(3):209-16.
    PMID: 19287359
    Amoebic serodiagnosis at Hospital Universiti Sains Malaysia (HUSM), Kelantan employs an indirect haemagglutination assay (IHA) which detects anti-Entamoeba histolytica antibodies in patients' serum samples. In an amoebiasis endemic area such as Kelantan, interpretation of a positive IHA result can be problematic due to the high background antibody levels. The TechLab E. histolytica II ELISA is a commercial kit for detection of specific Gal/GalNAc lectin antigen in stool samples, and has been reported to be able to detect the antigen in serum samples from patients with amoebic liver abscess (ALA). Thus in this study we investigated the usefulness of TechLab E. histolytica II ELISA for diagnosis of ALA by comparing it with IHA. This is a cross sectional study involving 58 suspected ALA patients who were admitted to the surgical ward, HUSM, Kelantan. The diagnosis of ALA was established based on clinical symptoms and signs, ultrasound and/or CT scan results. The serum specimens obtained from the patients were tested with IHA (Dade Behring Diagnostics, Marburg, Germany) and TechLab E. histolytica II ELISA (Techlab, Blacksburg, Virginia, USA) according to the manufacturers' instructions. Of the 58 patients, 72.4% (42) were positive by IHA and only 8.6% (5) were positive by the TechLab E. histolytica II ELISA. Agreement between the IHA and ELISA was poor (kappa value 0.019, p=0.691). There was also no correlation between ELISA results and IHA antibody titers. The TechLab E. histolytica II ELISA was not sensitive in detecting amoebic antigen in samples from ALA patients. In addition the results of the test did not correlate with the IHA anti-E. histolytica antibody titres. Therefore, the TechLab E. histolytica II ELISA was found not to be useful for serological diagnosis of ALA at HUSM.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  2. Zainah S, Wahab AH, Mariam M, Fauziah MK, Khairul AH, Roslina I, et al.
    J Virol Methods, 2009 Feb;155(2):157-60.
    PMID: 19022293 DOI: 10.1016/j.jviromet.2008.10.016
    The performance of a commercial immunochromatography test for rapid detection of dengue NS1 antigen present in serum or plasma of patients was evaluated against a commercial dengue NS1 antigen-capture ELISA. The rapid immunochromatography test gave an overall sensitivity of 90.4% with a specificity of 99.5%. The sensitivity was highest for serum samples from which virus was isolated (96.3%) and lowest for those from which virus was not isolated and RT-PCR was negative (76.4%). The sensitivity was significantly higher for serum samples from patients with acute primary dengue (92.3%) than those from patients with acute secondary dengue (79.1%). The positive predictive value and negative predictive value of this commercial immunochromatography test were 99.6% and 87.9% respectively.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  3. Yunus MH, Tan Farrizam SN, Abdul Karim IZ, Noordin R
    Am J Trop Med Hyg, 2018 Jan;98(1):32-38.
    PMID: 29141740 DOI: 10.4269/ajtmh.17-0632
    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara-positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  4. Wongphutorn P, Noordin R, Anuar NS, Worasith C, Kopolrat KY, Homwong C, et al.
    Am J Trop Med Hyg, 2024 Feb 07;110(2):254-262.
    PMID: 38190756 DOI: 10.4269/ajtmh.23-0518
    Strongyloidiasis, caused by Strongyloides stercoralis, is a neglected tropical disease with a global distribution. The infection can be fatal in immunocompromised individuals, and accurate diagnosis leading to timely treatment can save lives. Serodiagnosis is a sensitive method for diagnosis and is recommended for screening high-risk individuals. A point-of-care rapid test will facilitate the screening activities, especially in low-resource settings. This study aims to apply a new IgG4 immunochromatographic test using S. stercoralis recombinant antigen (SsRapid® cassette test) and to compare it with in-house IgG and IgG4 enzyme-linked immunosorbent assays (IgG- and IgG4-ELISAs) using native Strongyloides ratti antigen to investigate the epidemiology of strongyloidiasis in northeast Thailand. A total of 300 people participated, with 136 males and 164 females of a similar mean age. The reference tests were fecal examinations using the formalin-ethyl acetate concentration technique and an agar plate culture technique. The prevalence of S. stercoralis determined by SsRapid (81.7%) was significantly higher than that by fecal examinations (43.3%) or by antibody detection by IgG-ELISA (53.0%) or IgG4-ELISA (44.0%). The diagnostic sensitivities of SsRapid, IgG-ELISA, and IgG4-ELISA were found to be 93.9%, 77.7%, and 63.1%, respectively. The rate of positive tests by the SsRapid was significantly correlated to the levels of Strongyloides-specific IgG4 and IgG antibodies. By all diagnostic methods, male participants had a significantly higher prevalence of strongyloidiasis than females. Age was significantly associated with the concentration of specific serum IgG but not with the SsRapid grading score. In conclusion, SsRapid was shown to be a sensitive and valuable diagnostic test for the epidemiology study of strongyloidiasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  5. Wong WK, Foo PC, Olivos-Garcia A, Noordin R, Mohamed Z, Othman N, et al.
    Acta Trop, 2017 Aug;172:208-212.
    PMID: 28506795 DOI: 10.1016/j.actatropica.2017.05.017
    Crude soluble antigen (CSA) produced from Entamoeba histolytica trophozoite is conventionally used for serodiagnosis of invasive amoebiasis. However, high background seropositivities by CSA-assay in endemic areas complicate the interpretation of positive result in clinical settings. Instead, incorporating a second assay which indicates active or recent infection into the routine amoebic serology could possibly complement the limitations of CSA-assay. Hence, the present study aimed to evaluate the diagnostic efficacies of indirect ELISAs using CSA and excretory-secretory antigen (ESA) for serodiagnosis of amoebic liver abscess (ALA). Reference standard for diagnosis of ALA at Hospital Universiti Sains Malaysia is based on clinical presentation, radiological imaging and positive indirect haemagglutination assay (titer ≥256). Five groups of human serum samples collected from the hospital included Group I - ALA diagnosed by the reference standard and pus aspirate analysis using real-time PCR (n=10), Group II - ALA diagnosed by the reference standard only (n=41), Group III - healthy control (n=45), Group IV - other diseases control (n=51) and Group V - other infectious diseases control (n=31). For serodiagnosis of ALA serum samples (Group I and II), CSA-ELISA showed sensitivities of 100% for both groups, while ESA-ELISA showed sensitivities of 100% and 88%, respectively. For serodiagnosis of non-ALA serum samples (Group III, IV and V), CSA-ELISA showed specificities of 91%, 75% and 100%, respectively; while ESA-ELISA showed specificities of 96%, 98% and 100%, respectively. Indirect ELISAs using CSA and ESA have shown distinct strength for serodiagnosis of ALA, in terms of sensitivity and specificity, respectively. In conclusion, parallel analysis by both assays improved the overall efficacies of amoebic serology as compared to either single assay.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  6. Wong CL, Sieo CC, Tan WS
    J Virol Methods, 2013 Nov;193(2):611-9.
    PMID: 23933075 DOI: 10.1016/j.jviromet.2013.07.053
    Foot-and-mouth disease (FMD) is a highly contagious epidemic disease threatening the cattle industry since the sixteenth century. In recent years, the development of diagnostic assays for FMD has benefited considerably from the advances of recombinant DNA technology. In this study, the immunodominant region of the capsid protein VP1 of the foot-and-mouth disease virus (FMDV) was fused to the T7 bacteriophage and expressed on the surface of the bacteriophage capsid protein. The recombinant protein of about 42 kDa was detected by the anti-T7 tag monoclonal antibody in Western blot analysis. Phage ELISA showed that both the vaccinated and positive infected bovine sera reacted significantly with the recombinant T7 particle. This study demonstrated the potential of the T7 phage displaying the VP1 epitope as a diagnostic reagent.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  7. Wang SM, Sekaran SD
    J Clin Microbiol, 2010 Aug;48(8):2793-7.
    PMID: 20573879 DOI: 10.1128/JCM.02142-09
    Early definitive diagnosis of dengue virus infection may help in the timely management of dengue virus infection. We evaluated the Standard Diagnostics (SD, South Korea) dengue virus nonstructural protein NS1 antigen enzyme-linked immunosorbent assay (SD dengue NS1 Ag ELISA) for the detection of dengue virus NS1 antigen in patients' sera, using a total of 399 serum samples in a comparison with real-time reverse transcription (RT)-PCR, an in-house IgM capture (MAC)-ELISA, and a hemagglutination inhibition (HI) assay. Of the 320 dengue sera, 205 (64%) tested positive for NS1 antigen compared to 300 (93.75%) by either MAC-ELISA or RT-PCR, 161 (50.31%) by RT-PCR, and 226 (70.36%) by MAC-ELISA only. The assay was able to detect NS1 antigen in convalescent-phase sera until day 14 of infection. The NS1 detection rate is inversely proportional while the IgM detection rate is directly proportional to the presence of IgG antibodies. The overall sensitivity and specificity of the SD dengue NS1 Ag ELISA in the detection of "confirmed dengue virus" sera are 76.76% and 98.31%, respectively. This suggests that the SD kit is highly specific and sensitive for the detection of NS1 antigen. However, caution is needed when the kit is used as a single assay, as detection in samples that contained the virus was only about 81.97%. Combining this assay with an IgM and/or IgG assay will increase the sensitivity of detection, especially in areas with a higher prevalence of secondary dengue virus infections.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  8. Vadivelu J, Puthucheary SD, Gendeh GS, Parasakthi N
    Singapore Med J, 1995 Jun;36(3):299-302.
    PMID: 8553097
    Current diagnosis of melioidosis is based on bacterial culture and/or serology which is becoming increasingly useful. An IgM-ELISA using heat-killed whole cells of Pseudomonas pseudomallei was developed and compared with an indirect haemagglutination technique (IHAT) and an indirect immunofluorescent technique(IFAT). The IgM-ELISA using a P:N ratio of > or = 2 had a sensitivity of 91% and a specificity of 96%. All 3 assays were further used in a seroepidemiological survey amongst different groups of patients and healthy individuals. It was found that the IFAT performed better than the IHAT, detecting antibodies to P. pseudomallei in 6% of diabetics, 5% of pyrexics, 8% of pregnant women and 3% of farmers. For the same groups the IgM-ELISA detected antibodies in 1% of pyrexics, 8% of pregnant women and a further 14% of farmers. The IgM-ELISA was found to be sensitive and useful for the serological diagnosis of acute melioidosis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  9. Thayan R, Huat TL, See LL, Tan CP, Khairullah NS, Yusof R, et al.
    Trans R Soc Trop Med Hyg, 2009 Apr;103(4):413-9.
    PMID: 19203772 DOI: 10.1016/j.trstmh.2008.12.018
    Dengue infection is a major public health problem affecting millions of people living in tropical countries. With no suitable vaccines and specific antiviral drugs, treatment for dengue is usually symptomatic and supportive. Early diagnosis and recognition of severe disease is therefore crucial for better management of the patient. Two-dimension electrophoresis was used to identify disease-associated proteins that can be used for diagnosis and as drug targets for treatment. Two markers, identified by mass spectrometry analysis as alpha1-antitrypsin and NS1 proteins were found to be upregulated in dengue fever (DF; n=10) and dengue haemorrhagic fever (DHF; n=10) patients compared with healthy individuals (n=8). Both alpha1-antitrypsin and NS1 proteins were overexpressed two-fold in DHF patients compared with DF patients. Our study suggests that alpha1-antitrypsin and NS1 protein could be used as biomarkers as early indicators of DHF risk among patients with suspected dengue infection.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  10. Teoh BT, Sam SS, Tan KK, Johari J, Abd-Jamil J, Hooi PS, et al.
    Sci Rep, 2016 06 09;6:27663.
    PMID: 27278716 DOI: 10.1038/srep27663
    Timely and accurate dengue diagnosis is important for differential diagnosis and immediate implementation of appropriate disease control measures. In this study, we compared the usefulness and applicability of NS1 RDT (NS1 Ag Strip) and qRT-PCR tests in complementing the IgM ELISA for dengue diagnosis on single serum specimen (n = 375). The NS1 Ag Strip and qRT-PCR showed a fair concordance (κ = 0.207, p = 0.001). While the NS1 Ag Strip showed higher positivity than qRT-PCR for acute (97.8% vs. 84.8%) and post-acute samples (94.8% vs. 71.8%) of primary infection, qRT-PCR showed higher positivity for acute (58.1% vs. 48.4%) and post-acute (50.0% vs.41.4%) samples in secondary infection. IgM ELISA showed higher positivity in samples from secondary dengue (74.2-94.8%) than in those from primary dengue (21.7-64.1%). More primary dengue samples showed positive with combined NS1 Ag Strip/IgM ELISA (99.0% vs. 92.8%) whereas more secondary samples showed positive with combined qRT-PCR/IgM ELISA (99.4% vs. 96.2%). Combined NS1 Ag Strip/IgM ELISA is a suitable combination tests for timely and accurate dengue diagnosis on single serum specimen. If complemented with qRT-PCR, combined NS1 Ag Strip/IgM ELISA would improve detection of secondary dengue samples.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  11. Tengku-Idris TIN, Fong MY, Lau YL
    Trop Med Int Health, 2018 12;23(12):1374-1383.
    PMID: 30286271 DOI: 10.1111/tmi.13160
    OBJECTIVE: To investigate the seroprevalence of Sarcocystosis in the local communities of Pangkor and Tioman islands, Malaysia, by using antigenic recombinant surface antigens 2 and 3 from Sarcocystis falcatula (rSfSAG2 and rSfSAG3) as the target proteins via Western blot and ELISA assays.

    METHODS: SfSAG2 and SfSAG3 genes were isolated from S. falcatula and expressed in Escherichia coli expression system. A total of 348 serum samples [volunteers from both islands (n = 100), non-Sarcocystis parasitic infections patients (n = 50) and healthy donors (n = 100)] were collected and tested with purified SfSAGs in Western blot and ELISA assays to measure the seroprevalence of human sarcocystosis.

    RESULTS: None of the sera in this study reacted with rSfSAG2 by Western blot and ELISA. For rSfSAG3, relatively high prevalence of sarcocystosis was observed in Tioman Island (75.5%) than in Pangkor Island (34%) by Western blot. In ELISA, the different prevalence rate was observed between Tioman Island (43.8%) and Pangkor Island (37%). The prevalence rate in other parasitic infections (amoebiasis, cysticercosis, filariasis, malaria, toxocariasis and toxoplasmosis) was 30% by Western blot and 26% by ELISA. Only 8% (by Western blot) and 10% (by ELISA) of healthy donors showed reactivity towards rSfSAG3.

    CONCLUSION: This is the first study reporting a seroprevalence of sarcocystosis in Pangkor and Tioman Islands, Malaysia. The combination of Western blot and ELISA is suitable to be used for serodiagnosis of sarcocystosis. With further evaluations, SfSAG3 can potentially be used to confirm infection, asymptomatic screening, surveillance and epidemiological studies.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  12. Tay ST, Rohani MY, Ho TM, Devi S
    Diagn Microbiol Infect Dis, 2002 Oct;44(2):137-42.
    PMID: 12458119
    In this study, recombinant proteins that encompassed the AD I-AD III regions of 56 kDa immunodominant gene of 2 Orientia tsutsugamushi (OT) serotypes; Gilliam and TA763 were expressed in Escherichia coli. Both recombinant proteins exhibited serologic cross-reactivity with the rabbit antisera against various OT serotypes, as evaluated by enzyme-linked immunosorbent assay (ELISA), but not against other rickettsial species, including Rickettsia typhi, R. prowazekii and TT118 SFG rickettsiae. The feasibility of using the recombinant proteins as a diagnostic reagent was further evaluated by ELISA using sera from blood donors and scrub typhus patients. The results suggested a higher affinity of the antihuman IgM than IgG with both recombinant proteins. The IgM ELISA findings were agreeable with the results of indirect immunoperoxidase (IIP) assay especially with sera of high antibody (1:1600). However, more than one antigen are probably needed for development of an effective assay for serodiagnosis of scrub typhus in endemic areas.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  13. Tay SP, Cheong SK
    Malays J Pathol, 2002 Jun;24(1):45-51.
    PMID: 16329555
    Tissue Factor (TF) is a low molecular weight transmembrane glycoprotein that initiates the clotting protease cascade. It is considered to be the principal regulator of the extrinsic coagulation pathway, hemostasis and thrombosis, as well as inflammation and cellular immune response. An in-house two-step direct sandwich ELISA (enzyme-linked immunosorbent assay) for immunological quantification of plasma TF was successfully developed. The assay employed a monoclonal antibody against human TF (1:400 dilution; 1250 ng/ml) and peroxidase-conjugated anti-TF IgG (1:1000 dilution; 2000 ng/ml) as capture and detecting antibodies respectively, whilst tetramethylbenzidine/H2O2 were utilized as substrates. Titration curves of recombinant TF were linear within 10 to 4000 pg/ml, with a detection limit of 36.31 pg/ml. It demonstrated low intra- (2.50 - 9.23 CV%) and inter-assays (5.65 - 13.57 CV%) variability, as well as satisfactory analytical recovery (91.55 - 103.95%) and good parallelism. The assay developed was intended to be applied for measurement of plasma TF levels in patients with thrombotic disorders.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  14. Tan ZN, Wong WK, Noordin R, Zeehaida M, Olivos GA, Lim BH
    Trop Biomed, 2013 Jun;30(2):250-6.
    PMID: 23959490 MyJurnal
    Entamoeba histolytica causes amoebic diarrhoea, colitis and liver abscess (ALA). Diagnosis of ALA is difficult, as most patients do not have simultaneous intestinal amoebic infection. At Hospital Universiti Sains Malaysia (HUSM), diagnosis of ALA relies on a combination of clinical findings, ultrasound examination of the liver and serodiagnosis using a commercial kit. In this study, two in-house indirect ELISAs were developed and evaluated. One of the in-house assays utilises E. histolytica crude soluble antigen (CSA) to detect serum IgG specific to the parasite whereas the other uses E. histolytica ether extract antigen (EEA). Preparation of CSA requires a sonicator to lyse the amoeba whereas EEA was prepared by chemically solubilizing the trophozoites. Based on the cut-off value of mean optical density + 3SD, CSA-ELISA showed 100% (24/24) sensitivity and 93.33% (210/225) specificity; while EEA-ELISA showed 91.67% (22/24) sensitivity and 95.11% (214/225) specificity. In conclusion, both the in-house indirect ELISAs were found to be efficacious for diagnosis of ALA; and the EEA is easier to prepare than the commonly used CSA.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  15. Tamin A, Rota PA
    Dev Biol (Basel), 2013;135:139-45.
    PMID: 23689891 DOI: 10.1159/000189236
    Hendra virus (HeV) and Nipah virus (NiV) are the causative agents of emerging transboundary animal disease in pigs and horses. They also cause fatal disease in humans. NiV has a case fatality rate of 40 - 100%. In the initial NiV outbreak in Malaysia in 1999, about 1.1 million pigs had to be culled. The economic impact was estimated to be approximately US$450 million. Worldwide, HeV has caused more than 60 deaths in horses with 7 human cases and 4 deaths. Since the initial outbreak, HeV spillovers from Pteropus bats to horses and humans continue. This article presents a brief review on the currently available diagnostic methods for henipavirus infections, including advances achieved since the initial outbreak, and a gap analysis of areas needing improvement.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  16. Syahidatulamali CS, Wan Syamimee WG, Azwany YN, Wong KK, Che Maraina CH
    J Postgrad Med, 2017 9 2;63(4):257-261.
    PMID: 28862243 DOI: 10.4103/jpgm.JPGM_499_16
    BACKGROUND: Systemic lupus erythematosus (SLE) is a systemic autoimmune disease characterized by numerous autoantibodies. In this study, we investigated the presence of anti-chloride intracellular channel 2 (anti-CLIC2) and anti-high mobility group box 1 (anti-HMGB1) autoantibodies in SLE patients (n = 43) versus healthy controls ([HCs] n = 43), and their association with serological parameters (antinuclear antibody [ANA], anti-double-stranded DNA [anti-dsDNA], and C-reactive protein [CRP]) and disease activity using Systemic Lupus Erythematosus Disease Activity Index (SLEDAI) score (active or inactive).

    SETTINGS AND DESIGN: Case-control study at Rheumatology Clinic of Universiti Sains Malaysia Hospital.

    SUBJECTS AND METHODS: The sera of SLE patients and HCs were tested for the presence of anti-CLIC2 and anti-HMGB1 autoantibodies using human recombinant proteins and ELISA methodologies. Other serological parameters were evaluated according to routine procedures, and patients' demographic and clinical data were obtained.

    STATISTICAL ANALYSIS: Mann-Whitney U-test, Chi-square test, Fisher's exact test, and receiver operating characteristic analysis.

    RESULTS: Anti-CLIC2 autoantibody levels were significantly higher in SLE patients compared to HCs (P = 0.0035), whereas anti-HMGB1 autoantibody levels were not significantly elevated (P = 0.7702). Anti-CLIC2 and anti-HMGB1 autoantibody levels were not associated with ANA pattern, anti-dsDNA, and CRP. Interestingly, SLEDAI score (≥6) was associated with anti-CLIC2 (P = 0.0046) and with anti-HMGB1 (P = 0.0091) autoantibody levels.

    CONCLUSION: Our findings support the potential of using anti-CLIC2 autoantibodies as a novel biomarker for SLE patients. Both anti-CLIC2 and anti-HMGB1 autoantibody levels demonstrated potential in monitoring SLE disease activity.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  17. Suriya R, Hassan L, Omar AR, Aini I, Tan CG, Lim YS, et al.
    Zoonoses Public Health, 2008 Sep;55(7):342-51.
    PMID: 18667027 DOI: 10.1111/j.1863-2378.2008.01138.x
    Following a series of H5N1 cases in chickens and birds in a few states in Malaysia, there was much interest in the influenza A viruses subtypes that circulate among the local pig populations. Pigs may act as a mixing vessel for avian and mammal influenza viruses, resulting in new reassorted viruses. This study investigated the presence of antibodies against influenza H1N1 and H3N2 viruses in pigs from Peninsular Malaysia using Herdcheck Swine Influenza H1N1 and H3N2 Antibody Test Kits. At the same time, the presence of influenza virus was examined from the nasal swabs of seropositive pigs by virus isolation and real time RT-PCR. The list of pig farms was obtained from the headquarters of the Department of Veterinary Services, Malaysia, and pig herds were selected randomly from six of 11 states in Peninsular Malaysia. A total of 727 serum and nasal swab samples were collected from 4- to 6-month-old pigs between May and August 2005. By ELISA, the seroprevalences of swine influenza H1N1 and H3N2 among pigs were 12.2% and 12.1% respectively. Seropositivity for either of the virus subtypes was detected in less than half of the 41 sampled farms (41.4%). Combination of both subtypes was detected in 4% of all pigs and in 22% of sampled farms. However, no virus or viral nucleic acid was detected from nasal samples. This study identified that the seropositivity of pigs to H1N1 and H3N2 based on ELISA was significantly associated with factors such as size of farm, importation or purchase of pigs, proximity of farm to other pig farms and the presence of mammalian pets within the farm.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  18. Sulaiman S, Chong PP, Mokhtarudin R, Lye MS, Wan Hassan WH
    Trop Biomed, 2014 Mar;31(1):36-45.
    PMID: 24862043 MyJurnal
    Identification of pregnant women infected with Chlamydia trachomatis is essential to allow early antibiotic treatment in order to prevent adverse pregnancy outcomes. In this study, two nucleic acid amplification tests (NAAT) namely nested PCR (BioSewoom, Korea) and Amplicor CT/NG (Roche Diagnostic, USA) were evaluated in terms of sensitivity and specificity for the detection of C. trachomatis DNA in pregnant women with preterm complications. A cross-sectional study was carried out in two public hospitals in Southern Selangor, Malaysia. Endocervical swabs obtained were subjected to DNA amplification using nested PCR (BioSewoom, Korea) and Amplicor CT/NG (Roche Diagnostic, USA). A total of 83 endocervical swabs obtained from pregnant women of less than 37 weeks gestation and presented with preterm complications were subjected to chlamydial DNA detection using both assays. The study shows that Amplicor CT/NG assay is more effective in the detection of C. trachomatis DNA from endocervical swabs compared to Biosewoom nested PCR kit. Agreement between the two assays were poor (kappa=0.094) with nested PCR showing a low sensitivity of 10.81% and a 97.83% specificity when compared to Amplicor CT/NG. The results obtained indicated that BioSewoom nested PCR was less sensitive than Amplicor CT/ NG for detecting C. trachomatis in endocervical specimens and that another more reliable test is required for confirmatory result.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  19. Sue MJ, Yeap SK, Omar AR, Tan SW
    Biomed Res Int, 2014;2014:653014.
    PMID: 24971343 DOI: 10.1155/2014/653014
    Polymerase chain reaction-enzyme linked immunosorbent assay (PCR-ELISA) is an immunodetection method that can quantify PCR product directly after immobilization of biotinylated DNA on a microplate. This method, which detects nucleic acid instead of protein, is a much more sensitive method compared to conventional PCR method, with shorter analytical time and lower detection limit. Its high specificity and sensitivity, together with its semiquantitative ability, give it a huge potential to serve as a powerful detection tool in various industries such as medical, veterinary, and agricultural industries. With the recent advances in PCR-ELISA, it is envisaged that the assay is more widely recognized for its fast and sensitive detection limit which could improve overall diagnostic time and quality.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links