Displaying publications 1 - 20 of 106 in total

Abstract:
Sort:
  1. Wongphutorn P, Noordin R, Anuar NS, Worasith C, Kopolrat KY, Homwong C, et al.
    Am J Trop Med Hyg, 2024 Feb 07;110(2):254-262.
    PMID: 38190756 DOI: 10.4269/ajtmh.23-0518
    Strongyloidiasis, caused by Strongyloides stercoralis, is a neglected tropical disease with a global distribution. The infection can be fatal in immunocompromised individuals, and accurate diagnosis leading to timely treatment can save lives. Serodiagnosis is a sensitive method for diagnosis and is recommended for screening high-risk individuals. A point-of-care rapid test will facilitate the screening activities, especially in low-resource settings. This study aims to apply a new IgG4 immunochromatographic test using S. stercoralis recombinant antigen (SsRapid® cassette test) and to compare it with in-house IgG and IgG4 enzyme-linked immunosorbent assays (IgG- and IgG4-ELISAs) using native Strongyloides ratti antigen to investigate the epidemiology of strongyloidiasis in northeast Thailand. A total of 300 people participated, with 136 males and 164 females of a similar mean age. The reference tests were fecal examinations using the formalin-ethyl acetate concentration technique and an agar plate culture technique. The prevalence of S. stercoralis determined by SsRapid (81.7%) was significantly higher than that by fecal examinations (43.3%) or by antibody detection by IgG-ELISA (53.0%) or IgG4-ELISA (44.0%). The diagnostic sensitivities of SsRapid, IgG-ELISA, and IgG4-ELISA were found to be 93.9%, 77.7%, and 63.1%, respectively. The rate of positive tests by the SsRapid was significantly correlated to the levels of Strongyloides-specific IgG4 and IgG antibodies. By all diagnostic methods, male participants had a significantly higher prevalence of strongyloidiasis than females. Age was significantly associated with the concentration of specific serum IgG but not with the SsRapid grading score. In conclusion, SsRapid was shown to be a sensitive and valuable diagnostic test for the epidemiology study of strongyloidiasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  2. Mohd Ali MR, Sum JS, Aminuddin Baki NN, Choong YS, Nor Amdan NA, Amran F, et al.
    Int J Biol Macromol, 2021 Jan 31;168:289-300.
    PMID: 33310091 DOI: 10.1016/j.ijbiomac.2020.12.062
    Leptospirosis is a potentially fatal zoonosis that is caused by spirochete Leptospira. The signs and symptoms of leptospirosis are usually varied, allowing it to be mistaken for other causes of acute febrile syndromes. Thus, early diagnosis and identification of a specific agent in clinical samples is crucial for effective treatment. This study was aimed to develop specific monoclonal antibodies against LipL21 antigen for future use in leptospirosis rapid and accurate immunoassay. A recombinant LipL21 (rLipL21) antigen was optimized for expression and evaluated for immunogenicity. Then, a naïve phage antibody library was utilized to identify single chain fragment variable (scFv) clones against the rLipL21 antigen. A total of 47 clones were analysed through monoclonal phage ELISA. However, after taking into consideration the background OD405 values, only 4 clones were sent for sequencing to determine human germline sequences. The sequence analysis showed that all 4 clones are identical. The in silico analysis of scFv-lip-1 complex indicated that the charged residues of scFv CDRs are responsible for the recognition with rLipL21 epitopes. The generated monoclonal antibody against rLipL21 will be evaluated as a detection reagent for the diagnosis of human leptospirosis in a future study.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  3. Lee MJ, Ramanathan S, Mansor SM, Tan SC
    Anal Biochem, 2020 06 15;599:113733.
    PMID: 32302607 DOI: 10.1016/j.ab.2020.113733
    An enzyme-linked immunosorbent assay for detection of mitragynine, other closely related Kratom alkaloids and metabolites was developed using polyclonal antibodies. Mitragynine was conjugated to a carrier protein, cationized-bovine serum albumin using Mannich reaction. The synthesized antigen was injected into rabbits to elicit specific polyclonal antibodies against mitragynine. An enzyme conjugate was synthesized for evaluating its performance with the antibodies produced. The assay had an IC50 of 7.3 ng/mL with a limit of detection of 15 ng/mL for mitragynine. Antibody produced have high affinity for mitragynine (100%), other closely related Kratom alkaloids such as paynantheine (54%), speciociliatine (63%), 7α-hydroxy-7H-mitragynine (83%) and cross-reacted with metabolites 9-O-demethyl mitragynine (79%), 16-carboxy mitragynine (103%), 9-O-demethyl mitragynine sulfate (263%), 9-O-demethyl mitragynine glucuronide (60%), 16-carboxy mitragynine glucuronide (60%), 9-O-demethyl-16-carboxy mitragynine sulfate (270%) and 17-O-demethyl-16,17-dihydro mitragynine glucuronide (34%). It showed cross-reactivity less than 0.01% to reserpine, codeine, morphine, caffeine, methadone, amphetamine, and cocaine. Ten-fold dilution urine was used in the assay to reduce the matrix effects. The recovery ranged from 83% to 112% with variation coefficients in intraday and interday less than 8% and 6%, respectively. The ELISA turned out to be a convenient tool to diagnose mitragynine, other closely related Kratom alkaloids and metabolites in human urine samples.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  4. Noordin R, Yunus MH, Tan Farrizam SN, Arifin N
    Adv Parasitol, 2020;109:131-152.
    PMID: 32381194 DOI: 10.1016/bs.apar.2020.01.003
    Toxocariasis is a human infection primarily caused by larvae of Toxocara canis from dogs, and also by T. cati from cats. Children have a more significant risk of acquiring the infection due to their closer contact with pets, and greater chances of ingesting soil. Diagnosis of toxocariasis is based on clinical, epidemiological, and serological data. Indirect IgG ELISA is a widely used serodiagnostic method for toxocariasis, with native T. canis TES most commonly used as the antigen. Western blots, using the same antigen, can be used to confirm positive ELISA findings to reduce false-positive results. Improvements in Toxocara serodiagnosis include the use of recombinant TES antigens, simpler and more rapid assay formats, and IgG4 subclass detection. Also, incorporation of recombinant T. cati TES protein increases the diagnostic sensitivity. Development of antigen detection tests using polyclonal and monoclonal antibodies, nanobodies, or aptamers can complement the antibody detection assays, and enhance the effectiveness of the serodiagnosis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  5. Ch'ng ACW, Konthur Z, Lim TS
    Methods Enzymol, 2020;630:159-178.
    PMID: 31931984 DOI: 10.1016/bs.mie.2019.10.023
    Directed evolution is a proven approach to fine tune or modify biomolecules for various applications ranging from research to industry. The process of evolution requires methods that are capable of not only generating genetic diversity but also to distinguish the variants of desired characteristics. One method that is synonymous with directed evolution of proteins is phage display. Here, we present a protocol describing the application of magnetic nanoparticles coupled with a processor to carry out the identification of monoclonal antibodies (mAbs) from a diverse antibody library via phage display. Target antigens are coupled to magnetic nanoparticles as the solid phase for the isolation of the binding mAbs via affinity. A gradual enrichment in clones would result in increasing ELISA readouts with increasing rounds of panning. During monoclonal level analysis, positivity can be deduced with comparison to background and controls. The biopanning process can also be adopted for the directed evolution of enzymes, scaffold proteins or even peptides.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  6. Ambily R, Mini M, Siju J, Vamshikrishna S, Abhinay G, Gleeja VL, et al.
    Trop Biomed, 2019 Sep 01;36(3):654-663.
    PMID: 33597487
    A study was undertaken to evaluate the relevance of detecting IgM and IgG antibodies in diagnosis of canine leptospirosis in Kerala, a southern state of India, which is endemic for the disease. A total of 205 blood (35 from healthy vaccinated, 30 from healthy unvaccinated and 140 from diseased dogs) and 151 urine samples (11 from healthy vaccinated and 140 from diseased dogs) were collected from three districts of Kerala, Thrissur, Palakkad and Kozhikode with high incidence of leptospirosis. Recombinant LipL41 protein was used as antigen and IgG and IgM based ELISAs were standardized. The results were compared with the gold standard test, microscopic agglutination test (MAT). The MAT positive samples (146 samples) were divided into those having titre >1:800 and those between 1:100 and 1:400 in view that the former constituted the acute cases. It was found that IgM ELISA was more specific and sensitive in detecting acute cases (MAT >1:800) whereas IgG ELISA was less specific. In case of seroprevalence studies (MAT titre 1:100 to 1: 400), IgG ELISA was found to be more sensitive and specific than IgM ELISA. Receiver operating characteristic curves when plotted, revealed the accuracy of IgM ELISA in acute leptospirosis. Many samples were positive for both IgG and IgM antibodies. Polymerase Chain Reaction (PCR) targeting lipl41 gene was standardized and urine and blood samples from the same dogs were tested. PCR was found to be the specific test for the early detection of leptospires in blood even before seroconversion. However, PCR analysis of the urine samples was found to be insensitive. Hence, it can be concluded that the diagnostic strategies should be modified, and a combination of serological and molecular tests is recommended in endemic areas rather than simple detection of IgM or IgG antibodies, for the early detection of acute clinical cases of leptospirosis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  7. Rahumatullah A, Lim TS, Yunus MH, Noordin R
    Am J Trop Med Hyg, 2019 08;101(2):436-440.
    PMID: 31162018 DOI: 10.4269/ajtmh.19-0034
    Lymphatic filariasis is a mosquito-borne parasitic disease responsible for morbidity and disability that affects 1.2 billion people worldwide, mainly the poor communities. Currently, filarial antigen testing is the method of choice for the detection of bancroftian filariasis, and to date, there are two commonly used tests. In the present study, a recently reported recombinant monoclonal antibody (5B) specific to BmSXP filarial antigen was used in developing an ELISA for the detection of circulating filarial antigen in sera of patients with bancroftian filariasis. The performance of the ELISA was evaluated using 124 serum samples. The ELISA was positive with all sera from microfilaremic bancroftian filariasis patients (n = 34). It also showed 100% diagnostic specificity when tested with sera from 50 healthy individuals and 40 patients with other parasitic diseases. The developed assay using the novel 5B recombinant monoclonal antibody could potentially be a promising alternative antigen detection test for bancroftian filariasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  8. Lim PY, Cardosa MJ
    J Virol Methods, 2019 08;270:113-119.
    PMID: 31100287 DOI: 10.1016/j.jviromet.2019.05.005
    The goal of this paper was to develop a sandwich ELISA that can detect intact human enterovirus A71 (EV-A71) virus-like particles (VLPs) in vaccines. This assay specifically detected EV-A71 viruses from different sub-genogroups as well as EV-A71 VLPs, and treatment of VLPs with high heat and low pH reduced or completely abolished detection of the VLPs suggesting that the ELISA detected assembled particles. Using a purified VLP as a reference standard, a quantitative sandwich ELISA (Q-ELISA) was established which was used to monitor the yield and purity of the VLPs during manufacturing. Coupled with immunogenicity studies, the Q-ELISA was used to evaluate the performance of the VLPs and formalin-inactivated EV-A71 vaccine. This assay has the potential to play an important role in the development of an efficient process to produce and purify the VLPs and in examining the quality of EV-A71 vaccines.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  9. Tengku-Idris TIN, Fong MY, Lau YL
    Trop Med Int Health, 2018 12;23(12):1374-1383.
    PMID: 30286271 DOI: 10.1111/tmi.13160
    OBJECTIVE: To investigate the seroprevalence of Sarcocystosis in the local communities of Pangkor and Tioman islands, Malaysia, by using antigenic recombinant surface antigens 2 and 3 from Sarcocystis falcatula (rSfSAG2 and rSfSAG3) as the target proteins via Western blot and ELISA assays.

    METHODS: SfSAG2 and SfSAG3 genes were isolated from S. falcatula and expressed in Escherichia coli expression system. A total of 348 serum samples [volunteers from both islands (n = 100), non-Sarcocystis parasitic infections patients (n = 50) and healthy donors (n = 100)] were collected and tested with purified SfSAGs in Western blot and ELISA assays to measure the seroprevalence of human sarcocystosis.

    RESULTS: None of the sera in this study reacted with rSfSAG2 by Western blot and ELISA. For rSfSAG3, relatively high prevalence of sarcocystosis was observed in Tioman Island (75.5%) than in Pangkor Island (34%) by Western blot. In ELISA, the different prevalence rate was observed between Tioman Island (43.8%) and Pangkor Island (37%). The prevalence rate in other parasitic infections (amoebiasis, cysticercosis, filariasis, malaria, toxocariasis and toxoplasmosis) was 30% by Western blot and 26% by ELISA. Only 8% (by Western blot) and 10% (by ELISA) of healthy donors showed reactivity towards rSfSAG3.

    CONCLUSION: This is the first study reporting a seroprevalence of sarcocystosis in Pangkor and Tioman Islands, Malaysia. The combination of Western blot and ELISA is suitable to be used for serodiagnosis of sarcocystosis. With further evaluations, SfSAG3 can potentially be used to confirm infection, asymptomatic screening, surveillance and epidemiological studies.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  10. Lai JY, Loh Q, Choong YS, Lim TS
    Biotechniques, 2018 11;65(5):269-274.
    PMID: 30394125 DOI: 10.2144/btn-2018-0031
    Gene assembly methods are an integral part of molecular cloning experiments. The majority of existing vector assembly methods stipulate a need for exonucleases, endonucleases and/or the use of single-stranded DNA as starting materials. Here, we introduced a vector assembly method that employs conventional PCR to amplify stable double-stranded DNA fragments and assembles them into functional vectors specifically for antibody chain shuffling. We successfully formed vectors using cassettes amplified from different templates and assembled an array of single chain fragment variable clones of fixed variable heavy chain, with different variable light chains - a chain shuffling process for antibody maturation. The method provides an easy alternative to the conventional cloning process.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  11. Low GKK, Gan SC, Zainal N, Naidu KD, Amin-Nordin S, Khoo CS, et al.
    Pathog Glob Health, 2018 09;112(6):334-341.
    PMID: 30246621 DOI: 10.1080/20477724.2018.1516417
    This study aimed to evaluate vascular endothelial growth factor (VEGF) and pentraxin 3 (PTX-3) as predictive and diagnostic markers in differentiating severe dengue from non-severe dengue. The study was conducted in Ampang Health Clinic, Ampang Hospital and Serdang Hospital. The plasma levels of VEGF and PTX-3 were compared between severe dengue and non-severe dengue by ELISA from the day of presentation until discharged. Multiple logistic regression was used to develop predictive and diagnostic models by incorporating other clinical parameters. The receiver operating characteristics (ROC) analysis was used to assess the accuracy of the biomarkers and the developed models. Eighty-two patients were recruited, 29 with severe dengue and four died. The Area Under the Curve (AUC) was statistically significant in VEGF as diagnostic marker at Day 2 and 3 of illness with sensitivity of 80.00%-100.00% and specificity of 76.47%-80.00%. The predictive model with AUC of 0.84 (p 
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  12. Herman LS, Fornace K, Phelan J, Grigg MJ, Anstey NM, William T, et al.
    PLoS Negl Trop Dis, 2018 Jun;12(6):e0006457.
    PMID: 29902183 DOI: 10.1371/journal.pntd.0006457
    BACKGROUND: Plasmodium knowlesi is the most common cause of malaria in Malaysian Borneo, with reporting limited to clinical cases presenting to health facilities and scarce data on the true extent of transmission. Serological estimations of transmission have been used with other malaria species to garner information about epidemiological patterns. However, there are a distinct lack of suitable serosurveillance tools for this neglected disease.

    METHODOLOGY/PRINCIPAL FINDINGS: Using in silico tools, we designed and expressed four novel P. knowlesi protein products to address the distinct lack of suitable serosurveillance tools: PkSERA3 antigens 1 and 2, PkSSP2/TRAP and PkTSERA2 antigen 1. Antibody prevalence to these antigens was determined by ELISA for three time-points post-treatment from a hospital-based clinical treatment trial in Sabah, East Malaysia (n = 97 individuals; 241 total samples for all time points). Higher responses were observed for the PkSERA3 antigen 2 (67%, 65/97) across all time-points (day 0: 36.9% 34/92; day 7: 63.8% 46/72; day 28: 58.4% 45/77) with significant differences between the clinical cases and controls (n = 55, mean plus 3 SD) (day 0 p<0.0001; day 7 p<0.0001; day 28 p<0.0001). Using boosted regression trees, we developed models to classify P. knowlesi exposure (cross-validated AUC 88.9%; IQR 86.1-91.3%) and identified the most predictive antibody responses.

    CONCLUSIONS/SIGNIFICANCE: The PkSERA3 antigen 2 had the highest relative variable importance in all models. Further validation of these antigens is underway to determine the specificity of these tools in the context of multi-species infections at the population level.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  13. Yunus MH, Tan Farrizam SN, Abdul Karim IZ, Noordin R
    Am J Trop Med Hyg, 2018 Jan;98(1):32-38.
    PMID: 29141740 DOI: 10.4269/ajtmh.17-0632
    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara-positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  14. Ch'ng ACW, Hamidon NHB, Konthur Z, Lim TS
    Methods Mol Biol, 2018;1701:301-319.
    PMID: 29116512 DOI: 10.1007/978-1-4939-7447-4_16
    The application of recombinant human antibodies is growing rapidly mainly in the field of diagnostics and therapeutics. To identify antibodies against a specific antigen, panning selection is carried out using different display technologies. Phage display technology remains the preferred platform due to its robustness and efficiency in biopanning experiments. There are both manual and semi-automated panning selections using polystyrene plastic, magnetic beads, and nitrocellulose as the immobilizing solid surface. Magnetic nanoparticles allow for improved antigen binding due to their large surface area. The Kingfisher Flex magnetic particle processing system was originally designed to aid in RNA, DNA, and protein extraction using magnetic beads. However, the system can be programmed for antibody phage display panning. The automation allows for a reduction in human error and improves reproducibility in between selections with the preprogrammed movements. The system requires minimum human intervention to operate; however, human intervention is needed for post-panning steps like phage rescue. In addition, polyclonal and monoclonal ELISA can be performed using the semi-automated platform to evaluate the selected antibody clones. This chapter will summarize the suggested protocol from the panning stage till the monoclonal ELISA evaluation. Other than this, important notes on the possible optimization and troubleshooting are also included at the end of this chapter.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  15. Hajissa K, Zakaria R, Suppian R, Mohamed Z
    BMC Infect Dis, 2017 12 29;17(1):807.
    PMID: 29284420 DOI: 10.1186/s12879-017-2920-9
    BACKGROUND: The inefficiency of the current tachyzoite antigen-based serological assays for the serodiagnosis of Toxoplasma gondii infection mandates the need for acquirement of reliable and standard diagnostic reagents. Recently, epitope-based antigens have emerged as an alternative diagnostic marker for the achievement of highly sensitive and specific capture antigens. In this study, the diagnostic utility of a recombinant multiepitope antigen (USM.TOXO1) for the serodiagnosis of human toxoplasmosis was evaluated.

    METHODS: An indirect enzyme-linked immunosorbent assay (ELISA) was developed to evaluate the usefulness of USM.TOXO1 antigen for the detection of IgG antibodies against Toxoplasma gondii in human sera. Whereas the reactivity of the developed antigen against IgM antibody was evaluated by western blot and Dot enzyme immunoassay (dot-EIA) analysis.

    RESULTS: The diagnostic performance of the new antigens in IgG ELISA was achieved at the maximum values of 85.43% and 81.25% for diagnostic sensitivity and specificity respectively. The USM.TOXO1 was also proven to be reactive with anti- T. gondii IgM antibody.

    CONCLUSIONS: This finding makes the USM.TOXO1 antigen an attractive candidate for improving the toxoplasmosis serodiagnosis and demonstrates that multiepitope antigens could be a potential and promising diagnostic marker for the development of high sensitive and accurate assays.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  16. Lakshmipriya T, Gopinath SCB, Hashim U, Murugaiyah V
    Int J Biol Macromol, 2017 Dec;105(Pt 1):796-800.
    PMID: 28732727 DOI: 10.1016/j.ijbiomac.2017.07.115
    Enzyme Linked Immunosorbent Assay (ELISA) is a standard assay that has been used widely to validate the presence of analyte in the solution. With the advancement of ELISA, different strategies have shown and became a suitable immunoassay for a wide range of analytes. Herein, we attempted to provide additional evidence with ELISA, to show its suitability for multi-analyte detection. To demonstrate, three clinically relevant targets have been chosen, which include 16kDa protein from Mycobacterium tuberculosis, human blood clotting Factor IXa and a tumour marker Squamous Cell Carcinoma antigen. Indeed, we adapted the routine steps from the conventional ELISA to validate the occurrence of analytes both in homogeneous and heterogeneous solutions. With the homogeneous and heterogeneous solutions, we could attain the sensitivity of 2, 8 and 1nM for the targets 16kDa protein, FIXa and SSC antigen, respectively. Further, the specific multi-analyte validations were evidenced with the similar sensitivities in the presence of human serum. ELISA assay in this study has proven its applicability for the genuine multiple target validation in the heterogeneous solution, can be followed for other target validations.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  17. Hii SYF, Ali NA, Ahmad N, Amran F
    J Med Microbiol, 2017 Nov;66(11):1623-1627.
    PMID: 29048275 DOI: 10.1099/jmm.0.000611
    Melioidosis is an endemic infectious disease in Southeast Asia and northern Australia, caused by Burkholderia pseudomallei. However, the incidence rate in Malaysia is not well documented. The high mortality rate and broad range of clinical presentations require rapid and accurate diagnosis for appropriate treatment. This study compared the efficacy of in-house IgM and IgG ELISA methods using a local B. pseudomallei strain. The diagnostic accuracy of the in-house IgG ELISA was better than that of the IgM ELISA: sensitivity (IgG: 84.71 %, IgM: 76.14 %) and specificity (IgG: 93.64 %, IgM: 90.17 %); positive predictive value (IgG: 86.75 %, IgM: 79.76 %) and negative predictive value (IgG: 92.57 %, IgM: 89.66 %); likelihood ratio (LR) [IgG: 13.32, IgM: 7.75 (LR+); IgG: 0.16, IgM: 0.26 (LR-)], and was supported by the observation of the absorbance value in comparisons between culture and serology sampling. In-house IgG ELISA was shown to be useful as an early diagnostic tool for melioidosis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  18. Syahidatulamali CS, Wan Syamimee WG, Azwany YN, Wong KK, Che Maraina CH
    J Postgrad Med, 2017 9 2;63(4):257-261.
    PMID: 28862243 DOI: 10.4103/jpgm.JPGM_499_16
    BACKGROUND: Systemic lupus erythematosus (SLE) is a systemic autoimmune disease characterized by numerous autoantibodies. In this study, we investigated the presence of anti-chloride intracellular channel 2 (anti-CLIC2) and anti-high mobility group box 1 (anti-HMGB1) autoantibodies in SLE patients (n = 43) versus healthy controls ([HCs] n = 43), and their association with serological parameters (antinuclear antibody [ANA], anti-double-stranded DNA [anti-dsDNA], and C-reactive protein [CRP]) and disease activity using Systemic Lupus Erythematosus Disease Activity Index (SLEDAI) score (active or inactive).

    SETTINGS AND DESIGN: Case-control study at Rheumatology Clinic of Universiti Sains Malaysia Hospital.

    SUBJECTS AND METHODS: The sera of SLE patients and HCs were tested for the presence of anti-CLIC2 and anti-HMGB1 autoantibodies using human recombinant proteins and ELISA methodologies. Other serological parameters were evaluated according to routine procedures, and patients' demographic and clinical data were obtained.

    STATISTICAL ANALYSIS: Mann-Whitney U-test, Chi-square test, Fisher's exact test, and receiver operating characteristic analysis.

    RESULTS: Anti-CLIC2 autoantibody levels were significantly higher in SLE patients compared to HCs (P = 0.0035), whereas anti-HMGB1 autoantibody levels were not significantly elevated (P = 0.7702). Anti-CLIC2 and anti-HMGB1 autoantibody levels were not associated with ANA pattern, anti-dsDNA, and CRP. Interestingly, SLEDAI score (≥6) was associated with anti-CLIC2 (P = 0.0046) and with anti-HMGB1 (P = 0.0091) autoantibody levels.

    CONCLUSION: Our findings support the potential of using anti-CLIC2 autoantibodies as a novel biomarker for SLE patients. Both anti-CLIC2 and anti-HMGB1 autoantibody levels demonstrated potential in monitoring SLE disease activity.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  19. Wong WK, Foo PC, Olivos-Garcia A, Noordin R, Mohamed Z, Othman N, et al.
    Acta Trop, 2017 Aug;172:208-212.
    PMID: 28506795 DOI: 10.1016/j.actatropica.2017.05.017
    Crude soluble antigen (CSA) produced from Entamoeba histolytica trophozoite is conventionally used for serodiagnosis of invasive amoebiasis. However, high background seropositivities by CSA-assay in endemic areas complicate the interpretation of positive result in clinical settings. Instead, incorporating a second assay which indicates active or recent infection into the routine amoebic serology could possibly complement the limitations of CSA-assay. Hence, the present study aimed to evaluate the diagnostic efficacies of indirect ELISAs using CSA and excretory-secretory antigen (ESA) for serodiagnosis of amoebic liver abscess (ALA). Reference standard for diagnosis of ALA at Hospital Universiti Sains Malaysia is based on clinical presentation, radiological imaging and positive indirect haemagglutination assay (titer ≥256). Five groups of human serum samples collected from the hospital included Group I - ALA diagnosed by the reference standard and pus aspirate analysis using real-time PCR (n=10), Group II - ALA diagnosed by the reference standard only (n=41), Group III - healthy control (n=45), Group IV - other diseases control (n=51) and Group V - other infectious diseases control (n=31). For serodiagnosis of ALA serum samples (Group I and II), CSA-ELISA showed sensitivities of 100% for both groups, while ESA-ELISA showed sensitivities of 100% and 88%, respectively. For serodiagnosis of non-ALA serum samples (Group III, IV and V), CSA-ELISA showed specificities of 91%, 75% and 100%, respectively; while ESA-ELISA showed specificities of 96%, 98% and 100%, respectively. Indirect ELISAs using CSA and ESA have shown distinct strength for serodiagnosis of ALA, in terms of sensitivity and specificity, respectively. In conclusion, parallel analysis by both assays improved the overall efficacies of amoebic serology as compared to either single assay.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  20. Mirzadeh A, Saadatnia G, Golkar M, Babaie J, Noordin R
    Protein Expr. Purif., 2017 05;133:66-74.
    PMID: 28263855 DOI: 10.1016/j.pep.2017.03.001
    SAG1-related sequence 3 (SRS3) is one of the major Toxoplasma gondii tachyzoite surface antigens and has been shown to be potentially useful for the detection of toxoplasmosis. This protein is highly conformational due to the presence of six disulfide bonds. To achieve solubility and antigenicity, SRS3 depends on proper disulfide bond formation. The aim of this study was to over-express the SRS3 protein with correct folding for use in serodiagnosis of the disease. To achieve this, a truncated SRS3 fusion protein (rtSRS3) was produced, containing six histidyl residues at both terminals and purified by immobilized metal affinity chromatography. The refolding process was performed through three methods, namely dialysis in the presence of chemical additives along with reduced/oxidized glutathione and drop-wise dilution methods with reduced/oxidized glutathione or reduced DTT/oxidized glutathione. Ellman's assay and ELISA showed that the protein folding obtained by the dialysis method was the most favorable, probably due to the correct folding. Subsequently, serum samples from individuals with chronic infection (n = 76), probable acute infection (n = 14), and healthy controls (n = 81) were used to determine the usefulness of the refolded rtSRS3 for Toxoplasma serodiagnosis. The results of the developed IgG-ELISA showed a diagnostic specificity of 91% and a sensitivity of 82.89% and 100% for chronic and acute serum samples, respectively. In conclusion, correctly folded rtSRS3 has the potential to be used as a soluble antigen for the detection of human toxoplasmosis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods