Displaying publications 1 - 20 of 106 in total

Abstract:
Sort:
  1. Foong YT, Cheng HM, Sam CK, Dillner J, Hinderer W, Prasad U
    Int J Cancer, 1990 Jun 15;45(6):1061-4.
    PMID: 1693600
    The Epstein-Barr virus nuclear antigen I (EBNA I) is the only latent EBV antigen consistently expressed in malignant tissues of the nasopharynx. A 20-amino-acid synthetic peptide, p107 contains a major epitope of EBNA I. We tested sera from 210 patients with nasopharyngeal carcinoma (NPC) and from 128 normal individuals (NHS) for IgA antibodies to p107 using an enzyme-linked immunosorbent assay (ELISA). Whereas 191/210 (91%) of NPC patients had IgA antibodies to p107, only 17/128 (13.3%) of NHS had such antibodies and only 6/57 (10.5%) of sera from patients with malignancies other than NPC had IgA-p107 reactivity. Thirty-nine salivary samples from 46 NPC patients (84.8%) also contained IgA-p107 antibodies whereas only 3/42 (7.1%) of normal saliva samples were IgA-p107 positive. The results suggest that IgA antibodies to EBNA I may become a useful, easily measurable, marker for NPC.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  2. Hakim SL, Mak JW, Lam PL, Nazma S, Normaznah Y
    PMID: 1488706
    An enzyme-linked immunosorbent assay using excretory-secretory antigens of the second stage larvae maintained in vitro was used to determine the seroprevalence of Toxocara antibodies in Orang Asli (aborigines) of Peninsular Malaysia. The mean + 3 SD optical density of 30 healthy subjects was used as the cut-off point. Overall prevalence was found to be 31.9%. No significant relationship was found between positive rates with sex and age groups, though children between 0 to 9 years recorded the highest positive rates. Eosinophil counts were found to be closely related to the proportion of positivity to toxocaral infection and mean optical densities. There was some degree of cross-reaction with Trichuris trichuria positive sera.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  3. Goh KH, Goh ML, Thean ET, Khalid BA
    Med J Malaysia, 1992 Dec;47(4):248-60.
    PMID: 1303476
    A supersensitive ELISA was developed for measurement of thyroid-stimulating hormone (TSH) concentrations in serum using in-house rabbit polyclonal antisera and a commercial monoclonal antibody. The assay was optimised and validated by recovery, linearity and cross-reactivity experiments and further compared to other available assays and EQAS samples. Good precision was obtained with a working assay range of 0.2 to 100 mIU/L with < 10% coefficient of variation (CV) for both intra and interassay. The assay is highly sensitive and specific with a minimum detectable limit of 0.07 mIU/L and negligible cross-reactivities against LH, FSH, HCG and other pituitary peptides. Good correlations were obtained when compared to Abbott hTSH EIA (r = 0.993; p < 0.001; n = 85) and NETRIA IRMA (r + 0.995; p < 0.001; n = 76). The normal reference range established was 0.4 to 4.0 mIU/L (n = 76). TSH levels in serum of thyrotoxic patients (n = 83) were significantly lower (0.07 to 0.20 mIU/L, p < 0.0001) and completely distinct from normal values thereby obviating the requirement of a TRH-stimulation test. Stability studies showed that coated wells can be stored at 4 degrees C for at least 2 months. This highly sensitive in-house hTSH ELISA which is cheap, stable and readily available is useful for diagnosis and management of patients with various thyroid disorders.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  4. Mak JW, Khalid BA
    Med J Malaysia, 1992 Dec;47(4):235-7.
    PMID: 1303475
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  5. Lim PK, Mak JW, Yong HS
    PMID: 1298082
    Two monoclonal antibodies (MAbs), one produced against Plasmodium falciparum (PF-IG8) and the other against P. cynomolgi (PC-IE12) schizont antigens were used in a sandwich ELISA for the detection of circulating plasmodial antigens in sera of patients infected with either P. falciparum, P. vivax or P. malariae. The mean +/- SD optical density (OD) values for the normal control group using PF-108 and PC-1E12 were 0.351 +/- 0.036 and 0.205 +/- 0.044, respectively. Mean OD values for the three infected groups were found to be significantly higher than those of the normal control group for both MAbs. However, ELISA values for individual serum specimens did not correlate with the level of parasitemia in the infected blood. Using a cut-off point of mean OD +/- 3 SD of the normal control group as indicating a positive reading, the specificity of this assay with both MAbs was 100%. The sensitivity of the assay using PF-1G8 was 95% while that obtained with PC-1E12 was 98%.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  6. Cardosa MJ, Tio PH, Nimmannitya S, Nisalak A, Innis B
    PMID: 1298081
    The highly sensitive AFRIMS format IgM capture ELISA for the diagnosis of dengue virus infections requires the use of mouse brain derived hemagglutinins and consequently also the use of 20% acetone extracted normal human serum to eliminate high background. These reagents are not always easily available and we have thus compared the AFRIMS format with another published format which uses cell culture derived antigens (culture fluid, CF, format) in order to determine if it is reasonable to use cell culture derived antigens in situations where hemagglutinins and normal human serum are difficult to obtain. The study shows that using AFRIMS results as the reference point, the CF format described here has a sensitivity of 90% and a specificity of 96%.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  7. Mahnke C, Kashaiya P, Rössler J, Bannert H, Levin A, Blattner WA, et al.
    Arch Virol, 1992;123(3-4):243-53.
    PMID: 1314048
    Serum samples collected from patients with a wide variety of diseases from African and other countries were tested for antibodies to the human spumaretrovirus (HSRV). A spumaviral env-specific ELISA was employed as screening test. Out of 3020 human sera screened, 106 were found to be positive (3.2%). While the majority of patients' sera from Europe (1581) were negative, 26 were positive (1.6%). Sera from healthy adult blood donors (609), from patients with multiple sclerosis (48), Graves' disease (45), and chronic fatigue syndrome (41) were negative or showed a very low prevalence for spumaviral env antibodies. A higher percentage of seropositives (6.3%) were found among 1338 African patients from Tanzania, Kenya, and Gabon. Out of 1180 patients from Tanzania, 708 suffered from tumors, 75 from AIDS, and 128 had gynecological problems; 51 of the Tanzanian patients were HSRV seropositive (4.3%). A particularly high percentage of 16.6% seropositives were identified among nasopharyngeal carcinoma patients (NPC) from Kenya and Tanzania consistent with results reported 10 years ago. However, 20 nasopharyngeal carcinoma patients from Malaysia were HSRV-seronegative. In selected cases, sera from seropositive individuals were reacted with proteins from HSRV-infected cells in vitro. HSRV env- and gag-specific antibodies were specifically detected by these sera in Western blots. The results indicate spumavirus infections in human patients with various diseases at a relatively low prevalence worldwide; in African patients, however, the prevalence of spumavirus infections is markedly higher.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  8. Cheng HM, Foong YT, Mathew A, Sam CK, Dillner J, Prasad U
    J Virol Methods, 1993 Apr;42(1):45-51.
    PMID: 7686558
    An ELISA using the Epstein-Barr virus nuclear antigen 1 (EBNA 1) was found to detect selectively specific IgA in sera from patients with nasopharyngeal carcinoma (NPC). The antigen, p107, was a 20-amino acid synthetic peptide, representing a major epitope of EBNA 1.267/294 (90.8%) of NPC patients had IgA antibodies to p107 but in normal individuals, only 41/577 (7.1%) had IgA/p107. In sera from patients with other cancers, 11/77 (14.3%) had IgA/p107 reactivity. 124 IgA/VCA positive and 86 IgA/VCA negative NPC sera were also tested for IgA/p107 binding in ELISA. The majority of IgA/VCA positive sera (117) also contained IgA/p107 antibodies. Of interest was the detection of 74/86 IgA/p107 reactive sera in the IgA/VCA negative group. The results suggest that the IgA/p107 ELISA could become a useful, complementary screening assay to the IgA/VCA immunofluorescence test for detection of NPC.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  9. Lam SK
    Malays J Pathol, 1993 Jun;15(1):9-12.
    PMID: 8277797
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  10. Nazaimoon W, Ng ML, Bak K
    Malays J Pathol, 1993 Jun;15(1):75-83.
    PMID: 8277795
    A simple, non-isotopic in-house enzyme-linked immunoabsorbant assay (ELISA) for human growth hormone (GH) was developed. The assay involved using in-house polyclonal anti-GH adsorbed onto 96-well microtitre plates, commercially prepared mouse monoclonal anti-GH, and goat anti-mouse IgG horseradish peroxidase detection system. Results of recovery and parallelism studies ranged from 95%-106% and 98%-101% respectively, of the expected values. The detection limit of the assay was 0.008 mIU/well or the equivalent to 0.4 mIU/L of undiluted serum. Intra- and interassay coefficients of variations were 4.8%-7.9% and 6.5%-8.7% respectively. Serum GH levels measured in this assay correlated well with those measured in established in-house radioimmunoassays (r = 0.985, p < 0.001) and immunoradiometric assay from NETRIA (r = 0.984, p < 0.001).
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  11. Cardosa MJ, Hah FL, Choo BH, Padmanathan S
    PMID: 8160055
    A dot enzyme immunoassay for determination of antibodies to Japanese encephalitis virus was designed for use as a field technique for the surveillance of Japanese encephalitis virus activity among domestic pigs. The test was compared with the neutralization test and the hemagglutination inhibition test and found to be more sensitive than the hemagglutination inhibition test and comparable to the neutralization test in sensitivity but more simple to perform than either the neutralization or the hemagglutination inhibition tests. An IgM capture ELISA for the determination of JEV specific porcine IgM was also utilized to determine current infection rates in pigs. The tests which do not involve the determination of specific IgM are better used for testing sentinel animals for providing clues as to the rate of transmission of JEV among pigs. IgM tests determining acute infection are less likely to be useful unless animals are tested very frequently or if a great number of animals are tested at any one time.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  12. Rahmah N, Anuar AK, Karim R, Mehdi R, Sinniah B, Omar AW
    Biochem Biophys Res Commun, 1994 Nov 30;205(1):202-7.
    PMID: 7999024
    Sera from fifty subjects with different presentations of Brugian filariasis and from common soil-transmitted helminth infections were tested for specific anti-filarial IgG and its subclasses. Anti-filarial IgG, IgG1 and IgG3 showed cross-reactivities with soil-transmitted helminthic infections and no significant differences in optical densities among the various groups of filarial patients. In comparison with other groups of subjects, IgG4-ELISA of sera from microfilaraemic patients and some previously microfilaraemic patients showed a significant increase in optical density readings, while IgG2-ELISA showed elevated optical density readings in sera of patients with chronic elephantiasis. Therefore IgG2-ELISA is potentially useful in the diagnosis of brugian chronic elephantiasis while IgG4-ELISA may be beneficial for follow-up diagnosis of treated microfilaraemic patients.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  13. Vadivelu J, Puthucheary SD, Gendeh GS, Parasakthi N
    Singapore Med J, 1995 Jun;36(3):299-302.
    PMID: 8553097
    Current diagnosis of melioidosis is based on bacterial culture and/or serology which is becoming increasingly useful. An IgM-ELISA using heat-killed whole cells of Pseudomonas pseudomallei was developed and compared with an indirect haemagglutination technique (IHAT) and an indirect immunofluorescent technique(IFAT). The IgM-ELISA using a P:N ratio of > or = 2 had a sensitivity of 91% and a specificity of 96%. All 3 assays were further used in a seroepidemiological survey amongst different groups of patients and healthy individuals. It was found that the IFAT performed better than the IHAT, detecting antibodies to P. pseudomallei in 6% of diabetics, 5% of pyrexics, 8% of pregnant women and 3% of farmers. For the same groups the IgM-ELISA detected antibodies in 1% of pyrexics, 8% of pregnant women and a further 14% of farmers. The IgM-ELISA was found to be sensitive and useful for the serological diagnosis of acute melioidosis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  14. Eamsobhana P, Mak JW, Yong HS
    PMID: 9139382
    A specific monoclonal antibody (AW-3C2) as revealed by ELISA was produced against the adult worm antigens of Parastrongylus cantonensis and used in a sandwich ELISA for the detection of circulating antigens in the sera of parastrongyliasis patients and those with other parasitic diseases. A total of 60 sera was used in this study. Of these, 10 each were from patients with parastrongyliasis, cysticercosis, filariasis, gnathostomiasis, malaria and toxocariasis. The control group consisted of 53 serum samples from normal healthy Thais and Malaysians. The mean +/- optical density (OD) values for the normal Thai and Malaysian groups were 0.126 +/- 0.028 and 0.124 +/- 0.029, respectively. The mean OD values of the parastrongyliasis patient group differed significantly from that of the normal groups as well as those of other parasitic infections. Using a cut-off point of OD +/- 3SD of the control groups as indicating a positive reading, the specificity of the assay with this monoclonal antibody was 100% while the sensitivity was 50%.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  15. Cheong KB, Cheong SK, Boo NY, Jemilah M, Ton SH
    Malays J Pathol, 1995 Dec;17(2):91-6.
    PMID: 8935133
    An in-house enzyme-linked immunoabsorbant assay (ELISA) for SP-A was successfully developed using in-house polyclonal anti SP-A and a commercial polyclonal anti-rabbit immunoglobulin horseradish peroxidase conjugate system. The standard curve, generated by using 50 ng of SP-A to coat the plate and 1:500 dilution of polyclonal anti SP-A as a primary antibody, was linear for concentrations of SP-A ranging from 4 micrograms/l to 4000 micrograms/l and reproducible. Results of recovery study of SP-A from a known sample of tracheal aspirate ranged from 94%-114%. Intra- and inter-assay coefficients of variations were 2.7% and 5.6% respectively for a known sample of tracheal aspirate. Interference study showed that tracheal aspirate did not interfere with the assay. The assay developed was intended to be used for SP-A measurement in tracheal aspirates obtained from neonates with and without respiratory distress syndrome.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  16. Shah-Majid M
    Trop Anim Health Prod, 1996 May;28(2):181-2.
    PMID: 8809982
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  17. Eamsobhana P, Yong HS, Mak JW, Wattanakulpanich D
    PMID: 9561620
    A dot-blot ELISA was compared with a previously performed sandwich ELISA for the detection of Parastrongylus cantonensis antigens in sera from patients. Using the same monoclonal antibody and the same sera, 6 of 10 sera (60%) from parastronglyiasis patients were positive in dot-blot ELISA, whereas with sandwich ELISA, 5 of the same patient sera (50%) were positive. The specificity in both assays was 100% using 50 sera from patients with other parasitic diseases; of these, 10 each were from patients with cysticercosis, filariasis, gnathostomiasis, malaria and toxocariasis. The control group consisted of 53 sera from normal health Thais and Malaysians. The sensitivity of the assays was, however, slightly better with dot-blot ELISA and because it is simple, quick and cost-effective, it may be a test of choice for specific diagnosis of human parastrongyliasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  18. Kirnpal-Kaur BS, Yap KL, Tan SC
    Malays J Pathol, 1997 Dec;19(2):133-6.
    PMID: 10879254
    A blocking test was incorporated into the commercial IDEIA Adenovirus test (DAKO Diagnostics Ltd., Cambridgeshire, UK) to detect false positive results when faecal specimens were tested for adenovirus antigen. Immune rabbit serum raised against pooled adenovirus particles from human faecal specimens, together with the pre-immune serum, was used. Assessment of positive showed that false positives were produced under two different conditions: when results were based on visual determination instead of a cut-off value determined from photometric reading, and when absorbance values were not immediately read at the end of the test. Under the optimum condition for reading and assessment of test results (immediate reading and photometric determination), 11% of 65 adenovirus-positive samples were checked by the blocking ELISA as false positives. The rest of the specimens showed blocking of positive absorbance values by 70 to 98%. ELISA was found to be more sensitive than immune electron microscopy on samples with lower antigen concentration.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  19. Ambu S, Rain AN, Mak JW, Maslah D, Maidah S
    PMID: 9656366
    Three MAbs 1C4.2D8, 1C4.2C4 and 1C4.1F5 were produced using sonicated adult worm antigens of Angiostrongylus malaysiensis and they were found to be secreters of IgG1. The MAbs 1C4.2C4 and 1C4.2D8 were found to react with antigens of A. malaysiensis and cross-react with the closely related A. cantonensis but not with other helminths. A total of 108 human sera collected from Orang Asli (aborigenes) from Grik, in the State of Perak were tested for A. malaysiensis infection using the MAb-ELISA. MAb 1C4.1F5 and 25 (23%) were positive. Twenty of these positive samples were tested with the MAb 1C4.2D8 and none was found to be positive.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  20. Rahmah N, Anuar AK, Ariff RH, Zurainee MN, A'shikin AN, Fadzillah A, et al.
    Trop Med Int Health, 1998 Mar;3(3):184-8.
    PMID: 9593356
    OBJECTIVE: To evaluate the usefulness of antifilarial IgG4 antibody assay in detecting B. malayi infection in a filaria endemic area in Malaysia.

    METHODS: A sandwich ELISA using B. malayi soluble antigen was employed to detect antifilarial IgG4 antibodies in serum samples of 330 individuals who comprised 88 healthy individuals from nonendemic areas, 15 B. malayi microfilaraemic cases, 22 individuals with soil-transmitted helminthiases, 9 elephantiasis cases and 196 residents from a B. malayi-endemic area. An O.D. value of > 0.420 at serum dilution of 1:400 was used as the cut-off point. This cut-off point was obtained by taking the mean optical density (0.252 + 4 S.E.) of 36 negative sera which had O.D. values greater than 0.1 at serum dilution of 1:400.

    RESULTS: All 15 microfilaraemic persons were positive for antifilarial IgG4 antibody. Non-endemic normals, soil-transmitted helminth infected persons and chronic elephantiasis cases were negative for antifilarial IgG4 antibody. Of the 196 individuals from the filaria endemic area, 37 (18.8%) demonstrated presence of antifilarial IgG4 antibodies; and only eight individuals (4.1%) were positive for microfilariae. All eight microfilaraemic individuals were also positive for antifilarial IgG4 antibodies.

    CONCLUSION: Antifilarial IgG4-ELISA could detect 4.6 times more positive cases than the microfilaria detection method. With appropriate cut-off values that eliminate cross-reactivities, this serological tool is very useful for Brugia malayi prevalence surveys and diagnosis.

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links