Displaying publications 1 - 20 of 399 in total

Abstract:
Sort:
  1. Ng SF, Rouse JJ, Sanderson FD, Meidan V, Eccleston GM
    AAPS PharmSciTech, 2010 Sep;11(3):1432-41.
    PMID: 20842539 DOI: 10.1208/s12249-010-9522-9
    Over the years, in vitro Franz diffusion experiments have evolved into one of the most important methods for researching transdermal drug administration. Unfortunately, this type of testing often yields permeation data that suffer from poor reproducibility. Moreover, this feature frequently occurs when synthetic membranes are used as barriers, in which case biological tissue-associated variability has been removed as an artefact of total variation. The objective of the current study was to evaluate the influence of a full-validation protocol on the performance of a tailor-made array of Franz diffusion cells (GlaxoSmithKline, Harlow, UK) available in our laboratory. To this end, ibuprofen was used as a model hydrophobic drug while synthetic membranes were used as barriers. The parameters investigated included Franz cell dimensions, stirring conditions, membrane type, membrane treatment, temperature regulation and sampling frequency. It was determined that validation dramatically reduced derived data variability as the coefficient of variation for steady-state ibuprofen permeation from a gel formulation was reduced from 25.7% to 5.3% (n = 6). Thus, validation and refinement of the protocol combined with improved operator training can greatly enhance reproducibility in Franz cell experimentation.
    Matched MeSH terms: Equipment Design
  2. Chan BQ, Low ZW, Heng SJ, Chan SY, Owh C, Loh XJ
    ACS Appl Mater Interfaces, 2016 04 27;8(16):10070-87.
    PMID: 27018814 DOI: 10.1021/acsami.6b01295
    Shape memory polymers (SMPs) are smart and adaptive materials able to recover their shape through an external stimulus. This functionality, combined with the good biocompatibility of polymers, has garnered much interest for biomedical applications. In this review, we discuss the design considerations critical to the successful integration of SMPs for use in vivo. We also highlight recent work on three classes of SMPs: shape memory polymers and blends, shape memory polymer composites, and shape memory hydrogels. These developments open the possibility of incorporating SMPs into device design, which can lead to vast technological improvements in the biomedical field.
    Matched MeSH terms: Equipment Design*
  3. Soltani M, Moghaddam TB, Karim MR, Sulong NH
    Accid Anal Prev, 2013 Oct;59:240-52.
    PMID: 23820073 DOI: 10.1016/j.aap.2013.05.029
    Road safety barriers protect vehicles from roadside hazards by redirecting errant vehicles in a safe manner as well as providing high levels of safety during and after impact. This paper focused on transition safety barrier systems which were located at the point of attachment between a bridge and roadside barriers. The aim of this study was to provide an overview of the behavior of transition systems located at upstream bridge rail with different designs and performance levels. Design factors such as occupant risk and vehicle trajectory for different systems were collected and compared. To achieve this aim a comprehensive database was developed using previous studies. The comparison showed that Test 3-21, which is conducted by impacting a pickup truck with speed of 100 km/h and angle of 25° to transition system, was the most severe test. Occupant impact velocity and ridedown acceleration for heavy vehicles were lower than the amounts for passenger cars and pickup trucks, and in most cases higher occupant lateral impact ridedown acceleration was observed on vehicles subjected to higher levels of damage. The best transition system was selected to give optimum performance which reduced occupant risk factors using the similar crashes in accordance with Test 3-21.
    Matched MeSH terms: Equipment Design/standards*
  4. Hema CR, Paulraj MP, Yaacob S, Adom AH, Nagarajan R
    Adv Exp Med Biol, 2011;696:565-72.
    PMID: 21431597 DOI: 10.1007/978-1-4419-7046-6_57
    A brain machine interface (BMI) design for controlling the navigation of a power wheelchair is proposed. Real-time experiments with four able bodied subjects are carried out using the BMI-controlled wheelchair. The BMI is based on only two electrodes and operated by motor imagery of four states. A recurrent neural classifier is proposed for the classification of the four mental states. The real-time experiment results of four subjects are reported and problems emerging from asynchronous control are discussed.
    Matched MeSH terms: Equipment Design
  5. Dzulkarnain AAA, Abdullah SA, Ruzai MAM, Ibrahim SHMN, Anuar NFA, Rahim 'EA
    Am J Audiol, 2018 Sep 12;27(3):294-305.
    PMID: 30054628 DOI: 10.1044/2018_AJA-17-0087
    Purpose: The purpose of this study was to investigate the influence of 2 different electrode montages (ipsilateral and vertical) on the auditory brainstem response (ABR) findings elicited from narrow band (NB) level-specific (LS) CE-Chirp and tone-burst in subjects with normal hearing at several intensity levels and frequency combinations.

    Method: Quasi-experimental and repeated-measures study designs were used in this study. Twenty-six adults with normal hearing (17 females, 9 males) participated. ABRs were acquired from the study participants at 3 intensity levels (80, 60, and 40 dB nHL), 3 frequencies (500, 1000, and 2000 Hz), 2 electrode montages (ipsilateral and vertical), and 2 stimuli (NB LS CE-Chirp and tone-burst) using 2 stopping criteria (fixed averages at 4,000 sweeps and F test at multiple points = 3.1).

    Results: Wave V amplitudes were only 19%-26% larger for the vertical recordings than the ipsilateral recordings in both the ABRs obtained from the NB LS CE-Chirp and tone-burst stimuli. The mean differences in the F test at multiple points values and the residual noise levels between the ABRs obtained from the vertical and ipsilateral montages were statistically not significant. In addition, the ABR elicited from the NB LS CE-Chirp was significantly larger (up to 69%) than those from the tone-burst, except at the lower intensity level.

    Conclusion: Both the ipsilateral and vertical montages can be used to record ABR to the NB LS CE-Chirp because of the small enhancement in the wave V amplitude provided by the vertical montage.

    Matched MeSH terms: Equipment Design
  6. Chiu CL, Murugasu J, Chan L
    Anaesth Intensive Care, 2003 Apr;31(2):187-92.
    PMID: 12712784
    We have compared the use of the laryngeal mask airway with the new modified laryngeal tube in a prospective randomized controlled study. Sixty ASA 1 or 2 patients, aged 18 to 65 years, scheduled for elective surgery and breathing spontaneously under general anaesthesia, were studied. After preoxygenation, anaesthesia was induced with fentanyl and propofol. The patients were randomized to receive either a laryngeal mask airway or a laryngeal tube. Anaesthesia was maintained with nitrous oxide, oxygen and isoflurane. We recorded the speed and the ease of insertion, the number of attempts needed to successfully secure the airway and intraoperative complications, such as partial airway obstruction needing airway manipulation. The airway devices were removed with the patients fully awake at the end of surgery. Systolic arterial blood pressure, heart rate and end-tidal CO2 were recorded at various time intervals. Postoperative complications were recorded. We found that the incidence of partial airway obstruction needing intraoperative airway manipulation was higher with the laryngeal tube than with the laryngeal mask airway. We conclude that during spontaneous ventilation the modified laryngeal tube is not as reliable in providing a satisfactory airway and we consider it is not a suitable alternative to the laryngeal mask airway.
    Matched MeSH terms: Equipment Design
  7. Chiu CL, Wang CY
    Anaesth Intensive Care, 2004 Feb;32(1):77-80.
    PMID: 15058125
    This is a preliminary report on the use of the modified Airway Management Device in 50 spontaneously breathing patients undergoing elective day care surgery. We were successful in establishing a clear airway in all 50 patients, 46 of these patients had a patient airway on the first attempt. All patients were successfully managed with the Airway Management Device throughout the surgery. Partial airway obstruction during maintenance of anaesthesia occurred in three cases requiring only minor manipulations. Our result showed that the Airway Management Device may be used as an alternative airway management in anaesthesia.
    Matched MeSH terms: Equipment Design
  8. Kumar Sinasamy T, Nazaruddin Wan Hassan WM, Hardy Mohamad Zaini R, Seevaunnamtum P, Ab Mukmin L
    Anaesthesiol Intensive Ther, 2020;52(5):383-388.
    PMID: 33327696 DOI: 10.5114/ait.2020.101407
    INTRODUCTION: The Baska mask and i-gel are two new types of second-generation supraglottic airway devices. The aim of this study was to compare these two devices in terms of quality of insertion, quality of ventilation and post-insertion complications.

    MATERIAL AND METHODS: A total of 80 adult patients who were scheduled for elective surgery under general anaesthesia were randomised to two groups: Group BM: Baska mask (n = 40) and Group IG: i-gel (n = 40). The assessment focused on ease of insertion, number of attempts, insertion time, number of corrective manoeuvres, oropharyngeal leak pressure, tidal volume, peak airway pressure (PAP) and post-insertion complications.

    RESULTS: Group IG showed a significantly shorter median insertion time (13.3 [interquartile range, IQR 7.8] vs. 17.0 [IQR 9.6] s; P < 0.001), a higher percentage in the 'very easy' ease of insertion category (62.5% vs. 10.0%; P < 0.001), a higher percentage in the no corrective manoeuvre category (92.5% vs. 72.5%; P = 0.003) and a higher percentage in the no post-operative throat pain category (67.5% vs. 32.5%; P = 0.011) than Group BM. However, Group BM showed a significantly higher generated PAP than Group IG (12.7 [1.8] and 11.5 [2.2] cm H2O, respectively; P = 0.010). There were no significant differences in other parameters.

    CONCLUSIONS: The i-gel was better than the Baska mask in terms of ease of insertion, speed of insertion, fewer corrective manoeuvres and less post-operative throat pain. However, the Baska mask had a better cuff seal, as shown by a higher generated PAP.

    Matched MeSH terms: Equipment Design
  9. Karuppiah K, Salit MS, Ismail MY, Ismail N, Tamrin SB
    An Acad Bras Cienc, 2012 Dec;84(4):1169-88.
    PMID: 23207711
    The primary aim of this study is to examine the effects of a backrest: using a prototype of a lumbar support presented in author's earlier study on the discomfort rating of the body parts of motorcyclist.
    Matched MeSH terms: Equipment Design
  10. Al-Qaim FF, Mussa ZH, Yuzir A
    Anal Bioanal Chem, 2018 Aug;410(20):4829-4846.
    PMID: 29806068 DOI: 10.1007/s00216-018-1120-9
    The scarcity of data about the occurrence of pharmaceuticals in water bodies in Malaysia prompted us to develop a suitable analytical method to address this issue. We therefore developed a method based on solid-phase extraction combined with liquid chromatography-time of flight/mass spectrometry (SPE-LC-TOF/MS) for the analysis of sixteen prescribed and two nonprescribed pharmaceuticals that are potentially present in water samples. The levels of these pharmaceuticals, which were among the top 50 pharmaceuticals consumed in Malaysia during the period 2011-2014, in influent and effluent of five sewage treatment plants (STPs) in Bangi, Malaysia, were then analyzed using the developed method. All of the pharmaceuticals were separated chromatographically using a 5 μm, 2.1 mm × 250 mm C18 column at a flow rate of 0.3 mL/min. Limits of quantification (LOQs) were 0.3-8.2 ng/L, 6.5-89 ng/L, and 11.1-93.8 ng/L in deionized water (DIW), STP effluent, and STP influent, respectively, for most of the pharmaceuticals. Recoveries were 51-108%, 52-118%, and 80-107% from the STP influent, STP effluent, and DIW, respectively, for most of the pharmaceuticals. The matrix effect was also evaluated. The signals from carbamazepine, diclofenac sodium, and mefenamic acid were found to be completely suppressed in the STP influent. The signals from other compounds were found to be influenced by matrix effects more strongly in STP influent (enhancement or suppression of signal ≤180%) than in effluent (≤94%). The signal from prednisolone was greatly enhanced in the STP influent, indicating a matrix effect of -134%. Twelve pharmaceuticals were frequently detected in all five STPs, and caffeine, prazosin, and theophylline presented the highest concentrations among all the pharmaceuticals monitored: up to 7611, 550, and 319 ng/L in the STP influent, respectively. To the best of our knowledge, this is the first time that prazosin has been detected in a water matrix in Malaysia. Graphical abstract ᅟ.
    Matched MeSH terms: Equipment Design
  11. Tu Y, Ahmad N, Briscoe J, Zhang DW, Krause S
    Anal Chem, 2018 07 17;90(14):8708-8715.
    PMID: 29932632 DOI: 10.1021/acs.analchem.8b02244
    Light-addressable potentiometric sensors (LAPS) are of great interest in bioimaging applications such as the monitoring of concentrations in microfluidic channels or the investigation of metabolic and signaling events in living cells. By measuring the photocurrents at electrolyte-insulator-semiconductor (EIS) and electrolyte-semiconductor structures, LAPS can produce spatiotemporal images of chemical or biological analytes, electrical potentials and impedance. However, its commercial applications are often restricted by their limited AC photocurrents and resolution of LAPS images. Herein, for the first time, the use of 1D semiconducting oxides in the form of ZnO nanorods for LAPS imaging is explored to solve this issue. A significantly increased AC photocurrent with enhanced image resolution has been achieved based on ZnO nanorods, with a photocurrent of 45.7 ± 0.1 nA at a light intensity of 0.05 mW, a lateral resolution as low as 3.0 μm as demonstrated by images of a PMMA dot on ZnO nanorods and a pH sensitivity of 53 mV/pH. The suitability of the device for bioanalysis and bioimaging was demonstrated by monitoring the degradation of a thin poly(ester amide) film with the enzyme α-chymotrypsin using LAPS. This simple and robust route to fabricate LAPS substrates with excellent performance would provide tremendous opportunities for bioimaging.
    Matched MeSH terms: Equipment Design
  12. Akhbar MFA, Sulong AW
    Ann Biomed Eng, 2021 Jan;49(1):29-56.
    PMID: 32860111 DOI: 10.1007/s10439-020-02600-2
    As drilling generates substantial bone thermomechanical damage due to inappropriate cutting tool selection, researchers have proposed various approaches to mitigate this problem. Among these, improving the drill bit design is one of the most feasible and economical solutions. The theory and applications in drill design have been progressing, and research has been published in various fields. However, pieces of information on drill design are dispersed, and no comprehensive review paper focusing on this topic. Systemizing this information is crucial and, therefore, the impetus of this review. Here, we review not only the state-of-the-art in drill bit designs-advances in surgical drill bit design-but also the influences of each drill bit geometries on bone damage. Also, this work provides future directions for this topic and guidelines for designing an improved surgical drill bit. The information in this paper would be useful as a one-stop document for clinicians, engineers, and researchers who require information related to the tool design in bone drilling surgery.
    Matched MeSH terms: Equipment Design
  13. Goh KL
    Ann Acad Med Singap, 2015 Jan;44(1):34-9.
    PMID: 25703498
    Gastrointestinal (GI) endoscopy has evolved tremendously from the early days when candlelight was used to illuminate scopes to the extent that it has now become an integral part of the practice of modern gastroenterology. The first gastroscope was a rigid scope first introduced by Adolf Kussmaul in 1868. However this scope suffered from the 2 drawbacks of poor illumination and high risk of instrumental perforation. Rudolf Schindler improved on this by inventing the semiflexible gastroscope in 1932. But it was Basil Hirschowitz, using the principle of light conduction in fibreoptics, who allowed us to "see well" for the first time when he invented the flexible gastroscopy in 1958. With amazing speed and innovation, instrument companies, chiefly Japanese, had improved on the Hirschowitz gastroscope and invented a flexible colonoscope. Walter McCune introduced the technique of endoscopic retrograde cholangiopancreatography (ERCP) in 1968 which has now evolved into a sophisticated procedure. The advent of the digital age in the 1980s saw the invention of the videoendoscope. Videoendoscopes have allowed us to start seeing the gastrointestinal tract (GIT) "better" with high magnification and resolution and optical/digital enhancements. Fusing confocal and light microscopy with endoscopy has allowed us to perform an "optical biopsy" of the GI mucosa. Development of endoscopic ultrasonography has allowed us to see "beyond" the GIT lumen. Seeing better has allowed us to do better. Endoscopists have ventured into newer procedures such as the resection of mucosal and submucosal tumours and the field of therapeutic GI endoscopy sees no end in sight.
    Matched MeSH terms: Equipment Design
  14. Gendeh HS, Husain S
    Ann R Coll Surg Engl, 2021 Jul;103(7):536-537.
    PMID: 33913780 DOI: 10.1308/rcsann.2021.0009
    Matched MeSH terms: Equipment Design
  15. Wong KI, Ho MM
    PMID: 19162703 DOI: 10.1109/IEMBS.2008.4649200
    Extended patient monitoring has become increasingly important for detection of cardiac conditions, such as irregularities in the rhythms of the heart, while patient is practicing normal daily activity. This paper presents a design of a single lead wireless cardiac rhythm interpretive instrument that capable of capture the electrocardiogram (ECG) in digital format and transmitted to a remote base-station (i.e. PC) for storage and further interpretation. The design has achieved high quality of ECG and free of interference in the presence of motion.
    Matched MeSH terms: Equipment Design
  16. Ahmad Fadzil MH, Ihtatho D, Affandi AM, Hussein SH
    PMID: 19163606 DOI: 10.1109/IEMBS.2008.4650103
    Skin colour is vital information in dermatological diagnosis. It reflects pathological condition beneath the skin and commonly being used to indicate the extent of a disease. Psoriasis is a skin disease which is indicated by the appearance of red plaques. Although there is no cure for psoriasis, there are many treatment modalities to help control the disease. To evaluate treatment efficacy, PASI (Psoriasis Area and Severity Index) which is the current gold standard method is used to determine severity of psoriasis lesion. Erythema (redness) is one parameter in PASI. Commonly, the erythema is assessed visually, thus leading to subjective and inconsistent result. In this work, we proposed an objective assessment of psoriasis erythema for PASI scoring. The colour of psoriasis lesion is analyzed by DeltaL, Deltahue, and Deltachroma of CIELAB colour space. References of lesion with different scores are obtained from the selected lesions by two dermatologists. Results based on 38 lesions from 22 patients with various level of skin pigmentation show that PASI erythema score can be determined objectively and consistent with dermatology scoring.
    Matched MeSH terms: Equipment Design
  17. Khalid HM
    Appl Ergon, 2006 Jul;37(4):409-18.
    PMID: 16764817
    To develop product portfolios and affective design we need to understand the diversity in user needs. The challenge is how to predict what users want and how they will behave. One approach is to understand user emotions and affective needs, and predict successful product design that can match the needs. This paper discusses affect and its link to cognition. To provide a context, several theories are presented. A framework is described that incorporates characteristics of users, tasks, products, and use environment. The goal is to highlight the importance of emotions in enhancing the value of products. This research field, which we call Hedonomics, is new. There are many challenges in developing valid and reliable measurements of affect, which can influence human factors research as well as design.
    Matched MeSH terms: Equipment Design/psychology*
  18. Sen RN, Yeow PH
    Appl Ergon, 2003 Sep;34(5):453-63.
    PMID: 12963331
    A case study to illustrate the cost effectiveness of ergonomic redesign of electronic motherboard was presented. The factory was running at a loss due to the high costs of rejects and poor quality and productivity. Subjective assessments and direct observations were made on the factory. Investigation revealed that due to motherboard design errors, the machine had difficulty in placing integrated circuits onto the pads, the operators had much difficulty in manual soldering certain components and much unproductive manual cleaning (MC) was required. Consequently, there were high rejects and occupational health and safety (OHS) problems, such as, boredom and work discomfort. Also, much labour and machine costs were spent on repairs. The motherboard was redesigned to correct the design errors, to allow more components to be machine soldered and to reduce MC. This eliminated rejects, reduced repairs, saved US dollars 581495/year and improved operators' OHS. The customer also saved US dollars 142105/year on loss of business.
    Matched MeSH terms: Equipment Design
  19. Zen DI, Saidin N, Damanhuri SS, Harun SW, Ahmad H, Ismail MA, et al.
    Appl Opt, 2013 Feb 20;52(6):1226-9.
    PMID: 23434993 DOI: 10.1364/AO.52.001226
    We demonstrate mode locking of a thulium-bismuth codoped fiber laser (TBFL) operating at 1901.6 nm, using a graphene-based saturable absorber (SA). In this work, a single layer graphene is mechanically exfoliated using the scotch tape method and directly transferred onto the surface of a fiber pigtail to fabricate the SA. The obtained Raman spectrum characteristic indicates that the graphene on the core surface has a single layer. At 1552 nm pump power of 869 mW, the mode-locked TBFL self starts to generate an optical pulse train with a repetition rate of 16.7 MHz and pulse width of 0.37 ps. This is a simple, low-cost, stable, and convenient laser oscillator for applications where eye-safe and low-photon-energy light sources are required, such as sensing and biomedical diagnostics.
    Matched MeSH terms: Equipment Design
  20. Hashim S, Ibrahim SA, Che Omar SS, Alajerami YS, Saripan MI, Noor NM, et al.
    Appl Radiat Isot, 2014 Aug;90:258-60.
    PMID: 24858954 DOI: 10.1016/j.apradiso.2014.04.016
    Radiation effects of photon irradiation in pure Photonic Crystal Fibres (PCF) and Flat fibres (FF) are still much less investigated in thermoluminescense dosimetry (TLD). We have reported the TL response of PCF and FF subjected to 6 MV photon irradiation. The proposed dosimeter shows good linearity at doses ranging from 1 to 4 Gy. The small size of these detectors points to its use as a dosimeter at megavoltage energies, where better tissue-equivalence and the Bragg-Gray cavity theory prevails.
    Matched MeSH terms: Equipment Design
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links