Displaying all 6 publications

Abstract:
Sort:
  1. Salehi Z, Yusoff AL
    Radiat Prot Dosimetry, 2013;154(3):396-9.
    PMID: 23012482 DOI: 10.1093/rpd/ncs239
    A femur phantom made of wax and a real human bone was used to study the dose during radiographical procedures. The depth dose inside the phantom was determined using DOSXYZnrc, a Monte Carlo simulation software. The results were verified with measurements using TLD-100H. It was found that for 2.5 mm aluminium filtered 84-kVp X-rays, the radiation dose in the bone reached 57 % higher than the surface dose, i.e. 3.23 mGy as opposed to 2.06 mGy at the surface. The use of real bone introduces variations in the bone density in the DOSXYZnrc model, resulting in a lower attenuation effect than expected from solid bone tissues.
    Matched MeSH terms: Femur/physiology*
  2. Oshkour AA, Abu Osman NA, Yau YH, Tarlochan F, Abas WA
    Proc Inst Mech Eng H, 2013 Jan;227(1):3-17.
    PMID: 23516951
    This study aimed to develop a three-dimensional finite element model of a functionally graded femoral prosthesis. The model consisted of a femoral prosthesis created from functionally graded materials (FGMs), cement, and femur. The hip prosthesis was composed of FGMs made of titanium alloy, chrome-cobalt, and hydroxyapatite at volume fraction gradient exponents of 0, 1, and 5, respectively. The stress was measured on the femoral prosthesis, cement, and femur. Stress on the neck of the femoral prosthesis was not sensitive to the properties of the constituent material. However, stress on the stem and cement decreased proportionally as the volume fraction gradient exponent of the FGM increased. Meanwhile, stress became uniform on the cement mantle layer. In addition, stress on the femur in the proximal part increased and a high surface area of the femoral part was involved in absorbing the stress. As such, the stress-shielding area decreased. The results obtained in this study are significant in the design and longevity of new prosthetic devices because FGMs offer the potential to achieve stress distribution that more closely resembles that of the natural bone in the femur.
    Matched MeSH terms: Femur/physiology*
  3. Merican AM, Amis AA
    J Biomech, 2009 Jul 22;42(10):1539-1546.
    PMID: 19481211 DOI: 10.1016/j.jbiomech.2009.03.041
    The iliotibial band (ITB) has an important role in knee mechanics and tightness can cause patellofemoral maltracking. This study investigated the effects of increasing ITB tension on knee kinematics. Nine fresh-frozen cadaveric knees had the components of the quadriceps loaded with 175 N. A Polaris optical tracking system was used to acquire joint kinematics during extension from 100 degrees to 0 degrees flexion. This was repeated after the following ITB loads: 30, 60 and 90 N. There was no change with 30 N load for patellar translation. On average, at 60 and 90 N, the patella translated laterally by 0.8 and 1.4mm in the mid flexion range compared to the ITB unloaded condition. The patella became more laterally tilted with increasing ITB loads by 0.7 degrees, 1.2 degrees and 1.5 degrees for 30, 60 and 90 N, respectively. There were comparable increases in patellar lateral rotation (distal patella moves laterally) towards the end of the flexion cycle. Increased external rotation of the tibia occurred from early flexion onwards and was maximal between 60 degrees and 75 degrees flexion. The increase was 5.2 degrees, 9.5 degrees and 13 degrees in this range for 30, 60 and 90 N, respectively. Increased tibial abduction with ITB loads was not observed. The combination of increased patellar lateral translation and tilt suggests increased lateral cartilage pressure. Additionally, the increased tibial external rotation would increase the Q angle. The clinical consequences and their relationship to lateral retinacular releases may be examined, now that the effects of a tight ITB are known.
    Matched MeSH terms: Femur/physiology
  4. Makinejad MD, Abu Osman NA, Abu Bakar Wan Abas W, Bayat M
    Clinics (Sao Paulo), 2013 Sep;68(9):1180-8.
    PMID: 24141832 DOI: 10.6061/clinics/2013(09)02
    This study provides an experimental and finite element analysis of knee-joint structure during extended-knee landing based on the extracted impact force, and it numerically identifies the contact pressure, stress distribution and possibility of bone-to-bone contact when a subject lands from a safe height.
    Matched MeSH terms: Femur/physiology
  5. Iranpour F, Merican AM, Teo SH, Cobb JP, Amis AA
    Knee, 2017 Jun;24(3):555-563.
    PMID: 28330756 DOI: 10.1016/j.knee.2017.01.011
    BACKGROUND: Patellofemoral instability is a major cause of anterior knee pain. The aim of this study was to examine how the medial and lateral stability of the patellofemoral joint in the normal knee changes with knee flexion and measure its relationship to differences in femoral trochlear geometry.

    METHODS: Twelve fresh-frozen cadaveric knees were used. Five components of the quadriceps and the iliotibial band were loaded physiologically with 175N and 30N, respectively. The force required to displace the patella 10mm laterally and medially at 0°, 20°, 30°, 60° and 90° knee flexion was measured. Patellofemoral contact points at these knee flexion angles were marked. The trochlea cartilage geometry at these flexion angles was visualized by Computed Tomography imaging of the femora in air with no overlying tissue. The sulcus, medial and lateral facet angles were measured. The facet angles were measured relative to the posterior condylar datum.

    RESULTS: The lateral facet slope decreased progressively with flexion from 23°±3° (mean±S.D.) at 0° to 17±5° at 90°. While the medial facet angle increased progressively from 8°±8° to 36°±9° between 0° and 90°. Patellar lateral stability varied from 96±22N at 0°, to 77±23N at 20°, then to 101±27N at 90° knee flexion. Medial stability varied from 74±20N at 0° to 170±21N at 90°. There were significant correlations between the sulcus angle and the medial facet angle with medial stability (r=0.78, p<0.0001).

    CONCLUSIONS: These results provide objective evidence relating the changes of femoral profile geometry with knee flexion to patellofemoral stability.

    Matched MeSH terms: Femur/physiology*
  6. Fatihhi SJ, Rabiatul AA, Harun MN, Kadir MR, Kamarul T, Syahrom A
    J Mech Behav Biomed Mater, 2016 Feb;54:21-32.
    PMID: 26410762 DOI: 10.1016/j.jmbbm.2015.09.006
    The present study reports the effects of combined torsional and compressive cyclic loading on trabecular bone in order to mimic true physiological conditions and thereby provides improved data that represents clinical and real life conditions. However, only compressive behaviour is evaluated in most previous studies of bone mechanics. From the monotonic evaluation, it is observed that lower stress is needed for the onset of microcrack in the sample under torsional loading, compared to the stress needed in compression. Trabecular bone samples were subjected to a combination of torsion and compression fatigue at different stress levels during which they were compared to compressive axial fatigue. The stress levels were determined by considering the monotonic strength at 25-50% for both compressive and shear stresses. Significant decrease in fatigue lifetime is observed in between samples of pure compression fatigue and those with superpositioned torsional loading (p<0.05). The reduction in fatigue lifetime became more evident at a high torsional stress level. In this case, the failure of the sample is said to be 'torsional dominant'. Fatigue behaviour of bovine trabecular bone begins with plastic deformation, followed by strain accumulation and modulus reduction. As the strain rate increases, more energy dissipates and the sample finally failed. Further, the analysis of fractograph revealed something on the trabeculae by bending in sample with superpositioned torsional loading. In conclusion, torsional loading decreases the quality of the trabecular properties in terms of stiffness, life and structural integrity. It is hoped that results from this study will improve the understanding of the behaviour of trabecular bone under combined fatigue and help to develop future assessments of trabecular failure.
    Matched MeSH terms: Femur/physiology*
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links