Displaying publications 1 - 20 of 140 in total

Abstract:
Sort:
  1. Azlan AM, Mohammad AR, Ariffin AK
    Med J Malaysia, 2005 Jul;60 Suppl C:30-4.
    PMID: 16381280 MyJurnal
    This finite element analysis is aimed at comparing relative stiffness of three different posterior instrumentation constructs: the Hospital Universiti Kebangsaan Malaysia Spinal Instrumentation System (HUKM-SIS), the Cotrell-Dubousset Instrumentation (CDI) and Harrington Instrumentation System (HIS), used in the treatment of adolescent idiopathic scoliosis (AIS). The constructs were tested under various loads using MSC Patran 2001 r2a. Under increasing flexion loads, there was a linearly corresponding increase in deflection magnitudes for all constructs on the load-deflection curve. The CDI was the stiffest construct under axial, forward flexion and extension loads, followed by the HUKM-SIS and HIS. Under lateral bending loads, the HUKM-SIS construct was the stiffest followed by CDI and HIS. The HUKM-SIS construct was stiffer than HIS under torsional loads. We conclude that multiple pedicle screws increase the stiffness of posterior instrumentation constructs under all loads and inter-segmental spinous processes wiring increase the stiffness against lateral bending.
    Matched MeSH terms: Finite Element Analysis
  2. Banabilh SM, Rajion ZA, Samsudin R, Singh GD
    Aust Orthod J, 2006 Nov;22(2):99-103.
    PMID: 17203572
    To quantify and localise differences in Class I and Class II dental arches in Malay schoolchildren.
    Matched MeSH terms: Finite Element Analysis
  3. Banabilh SM, Rajion ZA, Samsudin AR, Singh GD
    Int J Orthod Milwaukee, 2006;17(4):17-20.
    PMID: 17256439
    Facial soft tissues are a major determinant of treatment choice. When Class I and Class II malocclusions were compared using finite-element analysis, morphologic differences were localized and quantified. This study highlights the importance of determining the timing, magnitude and direction offacial growth prior to treatment to achieve stable results.
    Matched MeSH terms: Finite Element Analysis*
  4. Lee HW, Arunasalam P, Laratta WP, Seetharamu KN, Azid IA
    J Biomech Eng, 2007 Aug;129(4):540-7.
    PMID: 17655475
    In this study, a hybridized neuro-genetic optimization methodology realized by embedding finite element analysis (FEA) trained artificial neural networks (ANN) into genetic algorithms (GA), is used to optimize temperature control in a ceramic based continuous flow polymerase chain reaction (CPCR) device. The CPCR device requires three thermally isolated reaction zones of 94 degrees C, 65 degrees C, and 72 degrees C for the denaturing, annealing, and extension processes, respectively, to complete a cycle of polymerase chain reaction. The most important aspect of temperature control in the CPCR is to maintain temperature distribution at each reaction zone with a precision of +/-1 degree C or better, irrespective of changing ambient conditions. Results obtained from the FEA simulation shows good comparison with published experimental work for the temperature control in each reaction zone of the microfluidic channels. The simulation data are then used to train the ANN to predict the temperature distribution of the microfluidic channel for various heater input power and fluid flow rate. Once trained, the ANN analysis is able to predict the temperature distribution in the microchannel in less than 20 min, whereas the FEA simulation takes approximately 7 h to do so. The final optimization of temperature control in the CPCR device is achieved by embedding the trained ANN results as a fitness function into GA. Finally, the GA optimized results are used to build a new FEA model for numerical simulation analysis. The simulation results for the neuro-genetic optimized CPCR model and the initial CPCR model are then compared. The neuro-genetic optimized model shows a significant improvement from the initial model, establishing the optimization method's superiority.
    Matched MeSH terms: Finite Element Analysis*
  5. Banabilh SM, Suzina AH, Dinsuhaimi S, Singh GD
    Aust Orthod J, 2007 Nov;23(2):89-95.
    PMID: 18200785
    Obstructive sleep apnoea (OSA) has been described as a public health problem comparable to smoking in its impacts upon society.
    Matched MeSH terms: Finite Element Analysis
  6. Seow LL, Toh CG, Fok AS, Wilson NH
    Am J Dent, 2008 Oct;21(5):331-6.
    PMID: 19024261
    PURPOSE: To investigate the level and distribution of stresses in endodontically treated maxillary premolar teeth restored using various cavity designs of bonded all-ceramic restorations. The hypothesis tested was that the various all-ceramic approaches, including incorporating a pulp chamber extension in the restoration, had no influence on the stresses in the restored tooth unit.
    METHODS: Finite element packages Patran and Abaqus were used for the stress analysis. The cavity designs investigated include: (1) inlay (I); (2) inlay with palatal cusp coverage (IPC); (3) onlay (O); (4) inlay with pulp chamber extension (IPE); (5) inlay with palatal cusp coverage and pulp chamber extension (IPCPE); and (6) onlay with pulp chamber extension (OPE).
    RESULTS: In each case, tensile stresses were found to be concentrated subjacent to the occlusal fossa. Peak tensile stress and peak shear stress values along the tooth/restoration interface for IPC, O IPCPE and OPE cavity designs were found to be associated with the axiogingival line angle. Overall, the order of the various forms of restoration investigated in terms of the maximum principal stress (from greatest to lowest) was as follows: IPE > IPCPE > OPE > I > IPC > O.
    Matched MeSH terms: Finite Element Analysis
  7. Banabilh SM, Suzina AH, Dinsuhaimi S, Samsudin AR, Singh GD
    J Oral Rehabil, 2009 Mar;36(3):184-92.
    PMID: 19207445 DOI: 10.1111/j.1365-2842.2008.01915.x
    The association between dental arch morphology and the aetiology of obstructive sleep apnoea (OSA) is not clear. To compare dental arch morphology in 108 Asian adults with and without ''OSA, overnight'' hospital polysomnography was performed, and sleep reports were obtained for all subjects. Standardized digital photographs were also taken of the subjects' upper and lower study models. Using 25 homologous landmarks, mean OSA and control dental arch configurations were computed, and subjected to finite-element morphometry (FEM), t-tests and principal components analysis (PCA). Mean upper and lower OSA dental arch morphologies were statistically different from respective Control upper and lower arch morphologies (P < 0.05). FEM of the upper arch indicated that the mean OSA configuration was 7-11% narrower in the transverse plane in the incisor and canine regions when compared with the control configuration, and inter-landmark analysis (ILA) confirmed this finding. FEM for the lower arch indicated that the mean OSA configuration was 10-11% narrower in the antero-posterior plane in the pre-molar and molar regions, and confirmed by ILA. Using PCA, significant differences were also found between the two groups in the lower arch using the first two eigenvalues, which accounted for 90% of the total shape change (P < 0.001). Supporting their role as aetiological factors, size and shape differences in dental arch morphology are found in patients with OSA.
    Matched MeSH terms: Finite Element Analysis
  8. Moo EK, Osman NA, Pingguan-Murphy B, Abas WA, Spence WD, Solomonidis SE
    Acta Bioeng Biomech, 2009;11(4):37-43.
    PMID: 20405814
    Conventionally, patellar tendon-bearing (PTB) sockets, which need high dexterity of prosthetist, are widely used. Lack of chartered and experienced prosthetist has often led to painful experience of wearing prosthesis and this will in turn deter the patients to wear the prosthesis, which will further aggravate stump shrinkage. Thus, the hydrostatic socket which demands relatively lower level of fabricating skill is proposed to replace the PTB socket in order to produce the equivalent, if not better, quality of support to the amputee patients. Both sockets' pressure profiles are studied and compared using finite element analysis (FEA) software. Three-dimensional models of both sockets were developed using MIMICS software. The analysis results showed that hydrostatic socket did exhibit more uniform pressure profiles than that of PTB socket. PTB socket showed pressure concentration near the proximal brim of the socket and also at the distal fibula. It was also found that the pressure magnitude in hydrostatic socket is relatively lower than that of PTB socket.
    Matched MeSH terms: Finite Element Analysis
  9. Ahmad, M.H., Norzaie, J., Al Qbadi, F., Daniel, B.D.
    ASM Science Journal, 2009;3(1):17-26.
    MyJurnal
    The functions of dams are for water supply, flood control and hydroelectric power generation. A concrete faced rockfill dam (CFRD) is preferred by dam consultants due to its many advantages. It is designed to withstand all applied loads, namely gravity load due to its massive weight and hydrostatic load due to water thrust from the reservoir. The structural response of the Bakun CFRD which is the second highest dam in the world after the Shuibuya Dam, was analyzed using finite element method. A two-dimensional plane strain finite element analysis of the non-linear Duncan-Chang hyperbolic model was used in the study of the dam in respect to the deformation and stresses of the main dam of Bakun CFRD project. The Dead-Birth-Ghost element technique was used to simulate sequences of the construction of the dam. The comparison of rigid and flexible foundation on the behaviour of the dam is discussed in this study. In the finite element modeling, the concrete slab on the upstream was represented through a six-noded element, while the interface characteristic between the dam body and the concrete slab was modeled using an interface element. The maximum settlement and stresses of the cross-section were found and their distribution was discussed and tabulated in the form of contours. The effect of reservoir filling loading had a gradual effect on the dam response behaviour. Comparisons with no water impoundment in the dam were also discussed.
    Matched MeSH terms: Finite Element Analysis
  10. Jaafar, M.S., Wong, N.J., Noorzaei, J., Thanoon, W.A.
    MyJurnal
    This study presents an efficient finite element analysis technique which shows great versatility in
    modelling of precast composite flooring system subjected to static loadings. The method incorporates sliding and opening in the analysis of composite structures using the interface element which was specifically designed to simulate the actual behaviour at the interfaces between contacting materials. A three-dimensional finite element model of the precast composite slab which exhibits discontinuous behaviour was performed to demonstrate the potential and applicability of the proposed method of analysis. The results of the analysis demonstrate that the overall response of a discontinuous system to external loading is significantly affected by the bonding condition at the interfaces between the contacting materials.
    Matched MeSH terms: Finite Element Analysis
  11. Kadir MR, Syahrom A, Ochsner A
    Med Biol Eng Comput, 2010 May;48(5):497-505.
    PMID: 20224954 DOI: 10.1007/s11517-010-0593-2
    Human bones can be categorised into one of two types--the compact cortical and the porous cancellous. Whilst the cortical is a solid structure macroscopically, the structure of cancellous bone is highly complex with plate-like and strut-like structures of various sizes and shapes depending on the anatomical site. Reconstructing the actual structure of cancellous bone for defect filling is highly unfeasible. However, the complex structure can be simplified into an idealised structure with similar properties. In this study, two idealised architectures were developed based on morphological indices of cancellous bone: the tetrakaidecahedral and the prismatic. The two architectures were further subdivided into two types of microstructure, the first consists of struts only and the second consists of a combination of plates and struts. The microstructures were transformed into finite element models and displacement boundary condition was applied to all four idealised cancellous models with periodic boundary conditions. Eight unit cells extracted from the actual cancellous bone obtained from micro-computed tomography were also analysed with the same boundary conditions. Young's modulus values were calculated and comparison was made between the idealised and real cancellous structures. Results showed that all models with a combination of plates and struts have higher rigidity compared to the one with struts only. Values of Young's modulus from eight unit cells of cancellous bone varied from 42 to 479 MPa with an average of 234 MPa. The prismatic architecture with plates and rods closely resemble the average stiffness of a unit cell of cancellous bone.
    Matched MeSH terms: Finite Element Analysis
  12. Chuah HG, Abd Rahim I, Yusof MI
    Comput Methods Biomech Biomed Engin, 2010 Jun;13(3):319-26.
    PMID: 19927241 DOI: 10.1080/10255840903208189
    The stress shielding effect is an event in which the replacement implant limits the load transferred to bone and the ineffective stress in the vertebrae causes bony growth to cease. In the present study, a 3D finite element L4-L5 model was developed and subjected to a 1200 N compression preload. Five groups of muscle forces were applied on L4 under flexion-extension, lateral bending and axial rotation. Topology optimisation was employed for reducing the stress shielding effect by removing the ineffective material from the design domain. The optimised design was designed with polyaryletheretherketone (PEEK) titanium and cortical materials to encounter the shielding response. The stress responses show that the new design increased the stress magnitude by at least 17.10, 18.11 and 18.43% in 4 Nm of flexion-extension, lateral bending and axial rotation, respectively. In conclusion, the material factor did not significantly alter the stress magnitude, but volume was the key factor in reducing the stress shielding effect.
    Matched MeSH terms: Finite Element Analysis
  13. Banabilh SM, Suzina AH, Mohamad H, Dinsuhaimi S, Samsudin AR, Singh GD
    Clin Oral Investig, 2010 Oct;14(5):491-8.
    PMID: 19806371 DOI: 10.1007/s00784-009-0342-9
    The aim of the present study is to investigate nasal airway morphology in Asian adults with and without obstructive sleep apnea (OSA) using acoustic rhinometry (AR), principal components analysis (PCA), and 3-D finite-element analysis (FEA). One hundred eight adult Malays aged 18-65 years (mean ± SD, 33.2 ± 13.31) underwent clinical examination and limited channel polysomnography, providing 54 patients with OSA and 54 non-OSA controls. The mean minimal cross section area 1 (MCA1) and the mean minimal cross sectional area 2 (MCA2) were obtained from AR for all subjects and subjected to t tests. The OSA and control nasal airways were reconstructed in 3-D and subjected to PCA and FEA. The mean MCA1 and MCA2 using AR were found to be significantly smaller in the OSA group than in the control group (p < 0.001). Comparing the 3-D OSA and control nasal airways using PCA, the first two eigenvalues accounted for 94% of the total shape change, and statistical differences were found (p < 0.05). Similarly, comparing the nasal airways using FEA, the 3-D mean OSA nasal airway was significantly narrower in the OSA group compared to the control group. Specifically, decreases in size of approx. 10-22% were found in the nasal valve/head of inferior turbinate area. In conclusion, differences in nasal airway morphology are present when comparing patients with OSA to controls. These differences need to be recognized as they can improve our understanding of the etiological basis of obstructive sleep apnea and facilitate its subsequent management.
    Matched MeSH terms: Finite Element Analysis
  14. Gasmelseed A
    Comput Methods Biomech Biomed Engin, 2011 Jul;14(7):665-71.
    PMID: 21480080 DOI: 10.1080/10255842.2011.563738
    In electromagnetic dosimetry, anatomical human models are commonly obtained by segmentation of magnetic resonance imaging or computed tomography scans. In this paper, a human head model extracted from thermal infrared images is examined in terms of its applicability to specific absorption rate (SAR) calculations. Since thermal scans are two-dimensional (2D) representation of surface temperature, this allows researchers to overcome the extensive computational demand associated with 3D simulation. The numerical calculations are performed using the finite-difference time-domain method with mesh sizes of 2 mm at 900 MHz plane wave irradiation. The power density of the incident plane wave is assumed to be 10 W/m(2). Computations were compared with a realistic anatomical head model. The results show that although there were marked differences in the local SAR distribution in the various tissues in the two models, the 1 g peak SAR values are approximately similar in the two models.
    Matched MeSH terms: Finite Element Analysis
  15. Yusoff N, Abu Osman NA, Pingguan-Murphy B
    Med Eng Phys, 2011 Jul;33(6):782-8.
    PMID: 21356602 DOI: 10.1016/j.medengphy.2011.01.013
    A mechanical-conditioning bioreactor has been developed to provide bi-axial loading to three-dimensional (3D) tissue constructs within a highly controlled environment. The computer-controlled bioreactor is capable of applying axial compressive and shear deformations, individually or simultaneously at various regimes of strain and frequency. The reliability and reproducibility of the system were verified through validation of the spatial and temporal accuracy of platen movement, which was maintained over the operating length of the system. In the presence of actual specimens, the system was verified to be able to deliver precise bi-axial load to the specimens, in which the deformation of every specimen was observed to be relatively homogeneous. The primary use of the bioreactor is in the culture of chondrocytes seeded within an agarose hydrogel while subjected to physiological compressive and shear deformation. The system has been designed specifically to permit the repeatable quantification and characterisation of the biosynthetic activity of cells in response to a wide range of short and long term multi-dimensional loading regimes.
    Matched MeSH terms: Finite Element Analysis
  16. Syahrom A, Abdul Kadir MR, Abdullah J, Öchsner A
    Med Biol Eng Comput, 2011 Dec;49(12):1393-403.
    PMID: 21947767 DOI: 10.1007/s11517-011-0833-0
    The relationship between microarchitecture to the failure mechanism and mechanical properties can be assessed through experimental and computational methods. In this study, both methods were utilised using bovine cadavers. Twenty four samples of cancellous bone were extracted from fresh bovine and the samples were cleaned from excessive marrow. Uniaxial compression testing was performed with displacement control. After mechanical testing, each specimen was ashed in a furnace. Four of the samples were exemplarily scanned using micro-computed tomography (μCT) and three dimensional models of the cancellous bones were reconstructed for finite element simulation. The mechanical properties and the failure modes obtained from numerical simulations were then compared to the experiments. Correlations between microarchitectural parameters to the mechanical properties and failure modes were then made. The Young's modulus correlates well with the bone volume fraction with R² = 0.615 and P value 0.013. Three different types of failure modes of cancellous bone were observed: oblique fracture (21.7%), perpendicular global fracture (47.8%), and scattered localised fracture (30.4%). However, no correlations were found between the failure modes to the morphological parameters. The percentage of error between computer predictions and the actual experimental test was from 6 to 12%. These mechanical properties and information on failure modes can be used for the development of synthetic cancellous bone.
    Matched MeSH terms: Finite Element Analysis
  17. Alsultaney, Hazem K., Mohd Khairol Anuar Mohd Ariffin, B.T. Hang Tuah Baharudin, Aidy Ali, Faizal Mustapha
    MyJurnal
    This work was carried out with the aim to optimise the tool path by simulating the removal of material in a finite element environment which is controlled by a genetic algorithm (GA). To simulate the physical removal of material during machining, a finite element model was designed to represent a thin walled workpiece. The target was to develop models which mimic the actual cutting process using the finite element method (FEM), to validate the developed tool path strategy algorithm with the actual machining process and to programme the developed algorithm into the software. The workpiece was to be modelled using the CAD (ABAQUS CAE) software to create a basic geometry co-ordinate system which could then be used to create the finite element method and necessary requirement by ABAQUS, such as the boundary condition, the material type, and the element type.
    Matched MeSH terms: Finite Element Analysis
  18. Saidin S, Abdul Kadir MR, Sulaiman E, Abu Kasim NH
    J Dent, 2012 Jun;40(6):467-74.
    PMID: 22366313 DOI: 10.1016/j.jdent.2012.02.009
    The aim of this study was to analyse micromotion and stress distribution at the connections of implants and four types of abutments: internal hexagonal, internal octagonal, internal conical and trilobe.
    Matched MeSH terms: Finite Element Analysis
  19. Raja Izaham RM, Abdul Kadir MR, Abdul Rashid AH, Hossain MG, Kamarul T
    Injury, 2012 Jun;43(6):898-902.
    PMID: 22204773 DOI: 10.1016/j.injury.2011.12.006
    The use of open wedge high tibial osteotomy (HTO) to correct varus deformity of the knee is well established. However, the stability of the various implants used in this procedure has not been previously demonstrated. In this study, the two most common types of plates were analysed (1) the Puddu plates that use the dynamic compression plate (DCP) concept, and (2) the Tomofix plate that uses the locking compression plate (LCP) concept. Three dimensional model of the tibia was reconstructed from computed tomography images obtained from the Medical Implant Technology Group datasets. Osteotomy and fixation models were simulated through computational processing. Simulated loading was applied at 60:40 ratios on the medial:lateral aspect during single limb stance. The model was fixed distally in all degrees of freedom. Simulated data generated from the micromotions, displacement and, implant stress were captured. At the prescribed loads, a higher displacement of 3.25 mm was observed for the Puddu plate model (p<0.001). Coincidentally the amount of stresses subjected to this plate, 24.7 MPa, was also significantly lower (p<0.001). There was significant negative correlation (p<0.001) between implant stresses to that of the amount of fracture displacement which signifies a less stable fixation using Puddu plates. In conclusion, this study demonstrates that the Tomofix plate produces superior stability for bony fixation in HTO procedures.
    Matched MeSH terms: Finite Element Analysis*
  20. Ishak MI, Abdul Kadir MR, Sulaiman E, Abu Kasim NH
    Int J Oral Maxillofac Surg, 2012 Sep;41(9):1077-89.
    PMID: 22575179 DOI: 10.1016/j.ijom.2012.04.010
    The aim of this study was to compare two different types of surgical approaches, intrasinus and extramaxillary, for the placement of zygomatic implants to treat atrophic maxillae. A computational finite element simulation was used to analyze the strength of implant anchorage for both approaches in various occlusal loading locations. Three-dimensional models of the craniofacial structures surrounding a region of interest, soft tissue and framework were developed using computed tomography image datasets. The implants were modelled using computer-aided design software. The bone was assumed to be linear isotropic with a stiffness of 13.4 GPa, and the implants were assumed to be made of titanium with a stiffness of 110 GPa. Masseter forces of 300 N were applied at the zygomatic arch, and occlusal loads of 150 N were applied vertically onto the framework surface at different locations. The intrasinus approach demonstrated more satisfactory results and could be a viable treatment option. The extramaxillary approach could also be recommended as a reasonable treatment option, provided some improvements are made to address the cantilever effects seen with that approach.
    Matched MeSH terms: Finite Element Analysis