METHODS: Thermomechanical damage-maximum bone temperature, osteonecrosis diameter, osteonecrosis depth, maximum thrust force, and torque-were calculated using the finite element method under various margin heights (0.05-0.25 mm) and widths (0.02-0.26 mm). The simulation results were validated with experimental tests and previous research data.
RESULTS: The effect of margin height in increasing the maximum bone temperature, osteonecrosis diameter, and depth were at least 19.1%, 41.9%, and 59.6%, respectively. The thrust force and torque are highly sensitive to margin height. A higher margin height (0.21-0.25 mm) reduced the thrust force by 54.0% but increased drilling torque by 142.2%. The bone temperature, osteonecrosis diameter, and depth were 16.5%, 56.5%, and 81.4% lower, respectively, with increasing margin width. The minimum thrust force (11.1 N) and torque (41.9 Nmm) were produced with the highest margin width (0.26 mm). The margin height of 0.05-0.13 mm and a margin width of 0.22-0.26 produced the highest sum of weightage.
CONCLUSIONS: A surgical drill bit with a margin height of 0.05-0.13 mm and a margin width of 0.22-0.26 mm can produce minimum thermomechanical damage in cortical bone drilling. The insights regarding the suitable ranges for margin height and width from this study could be adopted in future research devoted to optimizing the margin of the existing surgical drill bit.
Objectives: The main aim of this fundamental investigation is to examine the influence of a two-phase hybrid nanofluid approach on mixed convection characteristics including the consequences of varying Richardson number, number of oscillations, nanoparticle volume fraction, and dimensionless length and dimensionless position of the solid obstacle.
Methods: The migration of composite hybrid nanoparticles due to the nano-scale forces of the Brownian motion and thermophoresis was taken into account. There is an inner block near the middle of the enclosure, which contributes toward the flow, heat, and mass transfer. The top lid cover wall of the enclosure is allowed to move which induces a mixed convection flow. The impact of the migration of hybrid nanoparticles with regard to heat transfer is also conveyed in the conservation of energy. The governing equations are molded into the non-dimensional pattern and then explained using the finite element technique. The effect of various non-dimensional parameters such as the volume fraction of nanoparticles, the wave number of walls, and the Richardson number on the heat transfer and the concentration distribution of nanoparticles are examined. Various case studies for Al2O3-Cu/water hybrid nanofluids are performed.
Results: The results reveal that the temperature gradient could induce a notable concentration variation in the enclosure.
Conclusion: The location of the solid block and undulation of surfaces are valuable in the control of the heat transfer and the concentration distribution of the composite nanoparticles.
MATERIALS AND METHODS: Three-dimensional solid models of the maxilla, mucosa, and denture of a selected edentulous patient were created using Mimics and CATIA software. The FEA model was created and duplicated in ANSYS 16.0 to perform two simulations for the IOD and the CD models. The values of maximum stress and strain and total deformation were obtained and compared to the outcomes of premaxilla resorption from a parallel clinical study.
RESULTS: The maximum principal stress in the premaxilla in the IOD model ranged from 0.019 to 0.336 MPa, while it ranged from 0.011 to 0.193 MPa in the CD model. The maximum principal strain in the IOD model was 1.75 times greater than that in the CD model. Total deformation was 1.8 times higher in the IOD model. Greater bone resorption was observed in regions of higher stress, which were on the occlusal and buccal sides of the premaxilla residual ridge.
CONCLUSION: Stress, strain, and total deformation values present in the premaxilla area beneath a CD were approximately two times greater in a comparison between an opposing mandibular two-IOD and an opposing mandibular CD. The results were consistent with a parallel clinical study in which the rate of premaxilla bone resorption was almost three times greater in the IOD group.